Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | NOTE (Applicable for all items) :- The bidders/contractorsare advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.SCHEDULE \"A\" PART-I (INTERNAL ELECTRIFICATION) |
| 2 | Taking down carefully copper/aluminum point wiring (Light fan socket or power)complete including fixture and fittings such as switches, ceiling roses, pendants, regulators socket, light fittings etc removing materials for taking creditand making good disturbed surfaces of wall, floor, etc. |
| 3 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan controlled by one 5/6 amps, one way switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 4 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps switch socket combination on independent board including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 5 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick of size not less than 200 mm x 300 mm and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 6 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 2.5 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 7 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium grade) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 8 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (heavy duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 9 | M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 4 Sqmm (phase & neutral) and one run of 2.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (heavy duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 6/16 amps socket outlet on independent board controlled with one, 16 amps one way switch including all necessarywall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete allas directed and specified. |
| 10 | All as per Sl Item No. 1.02 here-in-before butdrawn inthrough existing concealed conduit. |
| 11 | All as per Sl Item No. 1.03 here-in-before butdrawn inthrough existing concealed conduit. |
| 12 | All as per Sl Item No. 1.04 here-in-before butdrawn inthrough existing concealed conduit. |
| 13 | All as per Sl Item No. 1.05 here-in-before butdrawn inthrough existing concealed conduit. |
| 14 | S & FIncluding connection of switch piano, flush button, type single pole one way 5 Amps, |
| 15 | S & FIncluding connection of switch socket combination 5 Amps 2 in 1 flush type, |
| 16 | S & FIncluding connection of switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type |
| 17 | S & Fceiling rose, polycarbonate three terminals. |
| 18 | S & F Electronic fan regulator, stepped type 120/280V complete all as directed by Engineer-in-Charge. |
| 19 | Supply and fixing including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 20 | Supply and fixing including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 21 | Supply and fixing modular Bell push 6A 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 22 | Supply & fixing including connection modular Switch socket combination 2 in 1,5 pin 5 amps 3 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 23 | Supply & fixing including connection modular Switch socket combination 2 in 1,6 pin 16 amps 3 modulescomplete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 24 | Supply & fixing including connection modularsocket outlet2 /3 pin 6 Amps 2 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 25 | Supply & fixing including connection modularsocket outlet2 /3 pin 6/16 Amps 2 modules complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 26 | Supply and fixing of Modular Fanregulator, 120 watts (Make : .Crabtree/Cona/Havells) |
| 27 | Supply and fixing white modular cover plate with frame 1 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 28 | Supply and fixing white modular cover plate with frame 2 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 29 | Supply and fixing white modular cover plate with frame 3 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 30 | Supply and fixing white modular cover plate with frame 4 Module complete all as specified and directed.(Make : .Crabtree/Cona/Havells) |
| 31 | Supply and fixing white modular cover plate with frame 6 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 32 | Supply and fixing white modular cover plate with frame 8 Module complete all as specified and directed. (Make : .Crabtree/Cona/Havells) |
| 33 | Supply and fixing modular metal flush box 1/2 Module complete all as specified and directed. |
| 34 | Supply and fixing modular metal flush box 3 Module complete all as specified and directed. |
| 35 | Supply and fixing modular metal flush box 4 Module complete all as specified and directed. |
| 36 | Supply and fixing modular metal flush box 6 Module complete all as specified and directed. |
| 37 | Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed by Engineer-in-Charge. |
| 38 | M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmmto be drawn in and including PVC conduit 25 mm dia (medium grade).Note:Three runs of 4 Sqmm copper wire and one run of PVC conduit shall be measured as one unit. |
| 39 | M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmmto be drawn in and including PVC conduit 25 mm dia (medium grade).Note:Three runs of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one unit. |
| 40 | M&L Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 2.50 Sqmmto be drawn in and including PVC conduit 20 mm dia (medium grade).Note:Three runs of 2.50 Sqmm copper wire and one run of PVC conduit shall be measured as one unit. |
| 41 | M&L Submain wiring using six runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmmto be drawn in and including PVC conduit 25 mm dia (medium grade).Note:Six runs of 6 Sqmm copper wire and one run of PVC conduit shall be measured as one unit. |
| 42 | Supply and fixin repair vertical TPN MCBDB 8 waywith 200 Amps rated busbar, double door type including provision for fixingMCCB 4 pole100 Amps, 25 KA complete includingtaking down old DB and making disturbed surafce good to match the existing surface Make Make : L&T cat part No. DBVTLOO8DD or equivalent in Havells/ Legrand |
| 43 | S & F in repairMCB DB made of sheet steel phosphatised powder coated with bus bar, neutral link, earth bar and din rail, double door type, TPN 4 way 240v, fixed in wall including making good disturbedsurfaces including taking down old unserviceable , complete all as directed by Engineer-in-Charge. Make :L&T cat part No. DBVTLOO4DD or equivalent in Havells/ Legrand |
| 44 | All as per Sl Item No 1.42 here-in-before but of SPN 8 way,240Volts double door as in repair. Make - L&T cat part No. DBSPNOO8DD or equivalent in Havells/ Legrand |
| 45 | All as per Sl Item No 1.42 here-in-before but of SPN 12 way,240Volts double door as in repair. Make - L&T cat part No. DBSPNO12DD or equivalent in Havells/ Legrand |
| 46 | S & F in repair MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 36 kA, 415 Volts, 100 Amps including taking down old unserviceable one. Make : Make - L&T cat part No. CM97919OOK2OG or equivalent in Havells/ Legrand |
| 47 | All as per Sl Item No 1.45 above but of capacity 63 Amps, 4 Pole, 18 KA. Make - L&T cat part No. CM90518OOJO or equivalent in Havells/ Legrand |
| 48 | S & F in repair MCB, SPN. 6-32 Amps rating 240, volt, \"C\" series, 10 kA,Make : Havells/Legrand/L&T |
| 49 | S & F in repair , MCB, TPN, 240V, 50Hz, 10kA, \"C\" series, 63 Amps series. Make : Havells/Legrand/L&T |
| 50 | S & F in repair , MCB, TP, 240V, 50Hz, 10kA, \"C\" series, 6 to32 Amps series. Make : Havells/Legrand/L&T |
| 51 | S & F in repair MCB, SP, 6 to 32 Amps, 240 volt, \"B\" Series, 10 kA, as in repairs.Make :Havells/Legrand/L&T |
| 52 | Supply and fix in repair LED battern pre wired suitable to use with LED tube, complete with powder coated decorative LED batten box typecomplete,including withPVC insulated flexible copper wire of size .5 sqmm 2 core from ceiling rose to fitting complete incl taking down old fitting all as specified and directed Make : SURYA Batten Cat part No SUB 118 T8 LED 1 X18 WATT or equivalent model of make list as given in Appdix \"A\". |
| 53 | All as per item as above here-in-before butenviroment friendly energy saving, T8 LED tub with aluminium extrucsion heat sink for optimum performance with high luminous efficacy and easy . Make : SURYA 18 PAL EXT or equivalent model of make list as given in Appdix \"A\". |
| 54 | Suplly and fix in repair recessed/surface mounted LED luminaire suitable for armstron/grid ceiling with its super bright LED 20 Watt is a delight in modern office environment this panel gives a soft soothing light additional mounting frame required for gypsum/pop ceiling installation deemed at this rate 1\"x1\", 20 W all as spd and directed by engrs in charge. Make : SURYA Celesta Cat Part No SLE DS 20 11S 20 Watt or equivalent model of make list as given in Appdix \"A\". |
| 55 | Suplly and fix in repair recessed/surface mounted LED luminaire suitable for armstron/grid ceiling with its super bright LED 36 Watt is a delight in modern office environment this panel gives a soft soothing light additional mounting frame required for gypsum/pop ceiling installation deemed at this rate2\"x2\", 36 W all as spd and directed by engrs in chargeMake SURYA Celesta Cat part No. SLE DS 36 22R or equivalent model of make list as given in Appdix \"A\". |
| 56 | Supply and fix in repair LED T8 40 wattBatten for multipurpose application made from extruded aluminium housing and polycorbonate diffuser40 watt with aluminiu housingcomplete all as specifiedincluding cutting and making space of suitable size on existing ceiling of any type complete all asdirected Make : SURY MapleCat Part No. SLE BTN T8 40 or equivalent model of make list as given in Appdix \"A\". |
| 57 | S & F in repair Sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP of 20 Amps . Make : L&T/Schnieder/Siemens |
| 58 | M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate),50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note :GI strip upto 7.5 m length shall be deemed to include in the cost of above item. |
| 59 | S & F in repair Earthing conductor with GI strip of size (25 x 4) mm complete all as directed by Engineer-in-Charge. |
| 60 | Fixing onlyin repair Earthing conductor with GI strip of size (25 x 4) mm mounted on insulator fixed with wall and surfacecomplete all as directed by Engineer-in-Charge.(Note :- Rate of Insulator fastners dirlling deemed at this rate) |
| 61 | Disconnecting electrically and dismantling of ceiling fans of any make capacity and type, washing thoroughly of bearing /bush, fan blades and body of fan by kerosene /petrol etc andgreasing for smooth functioning. Replacement of worn out/defective unserviceable parts (where ever necessary), reassembling the same including provision of three core flexible copper wire as per requirement (minimum 1.5m long), including one coat ofsynthetic enamel paint (first quality) with super glossy finish to fan body and blades refixing the same to its original position including testing complete all as directed by Engineer-in-Charge. (NOTE : Replacement of worn out/ defective/unserviceable parts and rewinding shall be measured and paid separately under relevant items of these schedule). |
| 62 | All as per Sl Item No 1.60 here-in-before but for Exhaust fans of any size and make. |
| 63 | All as per Sl Item No 1.60 here-in-before but for air circulator fans/wall mounting fans of any size and make. |
| 64 | M&L Rewinding the motor of AC ceiling fan of any make and size (1200/1400mm) with super enamelledcopper wire of adequate size/gauge including all insulation materials, varnishingetc complete all as directed by Engineer-in-Charge. |
| 65 | All as per Sl Item No 1.63 here-in-before but for exhaust fans of300/380mm sweep of any make. |
| 66 | All as per Sl Item No 1.63here-in-before but for air circulators/wall mounting fans of any make and size. |
| 67 | Supply only Ball bearing of suitable size for any type/make of ceiling fan, Make : TATA/NBC/SKF. |
| 68 | All as per Sl Item No 1.66 here-in-before but for Exhaust fans of any type/size/make. |
| 69 | All as per Sl Item No 1.66 here-in-before but for air circulators/ wall mounting fans of any type/size/make. |
| 70 | Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan, Make : SARADA/ TIBCON/ UNIVERSAL. |
| 71 | Supply only capacitor 220 volts,4 mfd suitable for ceiling fan, Make : SARADA/ TIBCON/ UNIVERSAL. |
| 72 | S & F in repairHanging clamp for ceiling fan of adequate size including rubber reel, nuts, bolts and washers etc complete including taking down old unserviceable one, all as directed by Engineer-in-Charge. |
| 73 | S&F in repairLEDBldg security light fitting 25 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housingepoxy powder coated in dark graphite greycolour suitable for mounting bracket of 40mm bore GI pipe light gradecomplete with all accessoriesincludingtaking down old fitting as directed. Make - SURYA Lexon Cat Part No SLE UL 25W IP66 (LXN) or or equivalent model of make list as given in Appdix \"A\". |
| 74 | Taking down geysers of capacity 25 liters and carrying to workshop for repairing, servicing, cleaningetc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location as directed.(Note:- Heating element, thermostat indicator lamp & thermal cutout etc shall be measured and paid separately as supply only) |
| 75 | Taking down geysers of capacity 50 liters and carrying to workshop for repairing, servicing, cleaningetc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location as directed.(Note:- Heating element, thermostat indicator lamp & thermal cutout etc shall be measured and paid separately as supply only) |
| 76 | Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete |
| 77 | Supply only thermostat ISI marked complete suitable for 25/50 liters capacity geyser |
| 78 | Supply only Indicating lamp (red/green/yellow) complete suitable for 25/50/100 liters capacity geyser |
| 79 | Supply and fixing for LT ACB of capacity 800 Amps 1000 Volts by all connected works including require at site for proper and smooth functing of air circuit breaker all as specified and as directed.Make : SIEMENS Cat PartWLI 800 N, No 491240204107 or equivalent model of make list given in Appendix A. |
| 80 | SCHEDULE \"A\" PART-II (SUMMER APPLIANCES AND VOLTAGE STABLIZERS) |
| 81 | Taking out unserviceable Receprocating type compressor of the Window /Split Type AC 1.5 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/ Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost. |
| 82 | Taking out unserviceable Receprocating type compressor of the Window /Split Type AC 2 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/ Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost. |
| 83 | Taking out unserviceable Rotary type compressor of Window/ Split Type AC 1.5 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost. |
| 84 | Taking out unserviceable Rotary type compressor of Window/ Split Type AC 2 Ton capacity, from site and replacement of compressor withnew oneto match with existing make/Model (R Compressor) and fixingof new compressor sealed unit in position, charging required quantity of refrigerant gas R-22/R-134a/R-410 as per existing design of AC, brazing of discharge andsuction line including leak testing complete as directed by the Engineer-in-charge Make :- Kirlosker / Hitachi / Hillie / Copeland / Danfoss. Note: Cost of copper capilary of any sizes, rubber pad bushing, modification work for fixing new compressor etc required for completing the repair is deemed to be included in the cost. |
| 85 | M/L for Gas charging with R-22 refrigerant gasforSplit / Windows ACs of any make, model and capacity, Refrigerator and Water coolersof any make, Modelof any capacity in positionor by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging. |
| 86 | M/L for Gas charging with R-410/R-134A refrigerant gasforSplit / Windows ACs of any make, model and capacity, Refrigerator and Water coolersof any make, Modelof any capacity in positionor by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging. |
| 87 | Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and outdoor unit ofSplit AC 2.0 TR Capacityusing suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all asspecified anddirected by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as \"Supplied only\" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge. |
| 88 | Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit ofSplit AC 1.5 TR Capacityusing suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all asspecified anddirected by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as \"Supplied only\" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge. |
| 89 | Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. unit of Window type AC 1/1.5/2 TR Capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all asspecified anddirected by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as \"Supplied only\" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge. |
| 90 | All as per Sl Item No. 2.07 above but for water cooler of any type, any size and any capacity. The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge. |
| 91 | All as per Sl Item No. 2.07 above but for Refrigerator / Deep freezer of any capacity, make and model . The inner tank of refrigrator / deep freezer should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed by Engineer-in-Charge. |
| 92 | Supplyonly thermostat for water cooler / refrigerator / deep freezer of any capacity and make. |
| 93 | Supply only relay for any type of water cooler /refrigerator/deep freezer of any capacity & make. |
| 94 | Supply only PCB suitable for split type A/C 1.5 TR capacityof any make/ model |
| 95 | Supplyonly PCB suitable for split type A/C 2 TR of any make. |
| 96 | Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR of any make and model. |
| 97 | Supply only Airsensorsuitable for split / window type A/C 1.5/2.0 TR of any make/ model |
| 98 | SupplyonlyCoil sensorsuitable for window / split type A/C1.5/ 2 TR of any make/ model |
| 99 | SupplyonlyRunning capacitor 45+5mfd for Window / Splittype Air conditionerof of any capacity. |
| 100 | Supply onlyRunning Capacitor capacitor 50+5 mfd for Air conditioner 2 Ton Capacity |
| 101 | SupplyonlyCapacitor of 2.50 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model . |
| 102 | Supplyonlycapacitor of 4.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model . |
| 103 | Supplyonlycapacitorof 6.0 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model. |
| 104 | Supplyonlyauto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions. |
| 105 | SupplyonlyBrass angle valveof size 5/8 inch for split AC 1.5/2TR capacity. |
| 106 | Supplyonly Brass angle valve 1/4 inch for split AC 1.5/2TR capacity. |
| 107 | Supply onlyNitrile Foam Insulation for copper tube of size 5/8 inch suitable for split AC including provision of requisite PVC fasteners. |
| 108 | Supply onlyNitrile Foam Insulation for copper tube of size 3/8 inch suitable for split AC including provision of requisite PVC fasteners.. |
| 109 | SupplyonlyNitrile Foam Insulation for copper tube of size 1/2 inch suitable for split AC including provision of requisite PVC fasteners.. |
| 110 | SupplyonlyPVC ball valves / float valve for water cooler of any capacity & make |
| 111 | Supplyonly Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions. |
| 112 | Supplyonlyrelayof model suitable for Window type ACof any capacity and to match with existing design conditions.. |
| 113 | Supplyonly Remote Universal type suitable for all type of split / window AC of any make and model or any capacity and to match with existing design conditions.. |
| 114 | SupplyonlyPVC Drain pipe of size1/2\" size suitable for Split type AC of any capacity. |
| 115 | Supplyonly , mainDrain pipe of indoor unitof size 3/4 \", PVC Flexible type suitable for Split type ACof any capacity. |
| 116 | SupplyonlyRubber Bush for Fan Motor of out door unit of split type AC and Window type AC of any capacityandany make and model . |
| 117 | Supplyonly Flairing Nuts of Size 5/8 inch for out door unit of Split type AC of Any make and model. |
| 118 | Supplyonly Flairing Nuts of Size 1/2 inch for out door unit of Split type AC of Any make and model. |
| 119 | Supplyonly Flairing Nuts of Size 1/4 inch for out door unit of Split type AC of Any make and model. |
| 120 | Taking down unserviceable Fan Motorof Window / Split type AC1.5/2.0 TR capacity and of any make and model, removing burnt winding, insulation material, cleaning the surfaces,rewindingthe motor with super enameled copper winding wire of same gauge and size including insulation material and varnishingand re-fixing at site all as directed by Eng-in-Charge. |
| 121 | Taking down unserviceable Condenser fanmotor of water cooler/refrigerator/deep freezer of any capacity, make and model, removing burnt winding, insulation material, cleaning the surfaces,rewindingthe motor with super enameled copper winding wire of same gauge and size including insulation material and varnishingand re-fixing at site all as directed by Eng-in-Charge. |
| 122 | Supply and fixing in repair,Out door Bracket suitable for fixingout door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed. |
| 123 | Taking down existing split type AC indoor and outdoor units complete of any make / capacity after disconnecting all accessoriesand Refixing at a different location including making necessary fixing arrangements, after carrying out necessary maintenance / servicing including testing on load at site completeall as specified and directed by Engineer - in- charge . Note:-vacuuming / Gas Charging / spares parts etc if required will be measured and paid seperately under revelent Items of schedule of works . |
| 124 | Supply and fixing in repairCondenser Fan motor ISI markedof window/split Ac of 1.5 TR / 2 TR capacity of any make and model all as directed. |
| 125 | Supplyand fixing in repair Blower Fan motor assembly of indoor unit of split AC 1.5/2TR of any make and model and all as directed. |
| 126 | M/L for carrying out spray painting completeunit of window type AC of anymake, modeland capacity after dismantling, and paintingon sheet metal enclosers interanally andexternally with twocoats of syntheticenamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed. |
| 127 | All as per Sl Item No. 2.46 above but for outdoor unit of split AC of any capacity make and model. |
| 128 | Supply and fixing in repair Copper Condenser CoilISI marked suitable for Window type AC of 1.5/2TRcapacityof any make and model to match with existing design conditions. |
| 129 | Supply and fixing in repair Copper Condesser CoilISI marked suitable for Split type AC of1.5 /2.0TRcapacityof any make and model to match with existing design conditions. |
| 130 | Supply and fixing in repair Cooling Coilsuitable ISI markedfor Windowtype AC of1.5 TRcapacityof any make and model to match with existing design conditions. |
| 131 | Supply andfixing in repair 3 Core 2.5 Sqmm multistrand copper conductor PVC insulated sheathed flexible cable suitable for AC / water cooler / Refrigerator / AC / Voltage stabilizer. |
| 132 | Supply and fixing in repair Electronic Circuit Board Suitable for Out door unit ofSplit type AC 1.5/2.0 TR(Voltas/Lloyd Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge |
| 133 | Supply and fixing in repair Electronic Circuit Board Suitable for Indoor unit ofSplit type AC 1.5/2.0 TR(Voltas/Lloyd Inverter model ) and all as per Existing make and model , All as specified and directed by Engr - in - Charge |
| 134 | Supply and replacement of compressorfor water cooler40/80 Ltr capacity and assembling and testing the compressor unit completeincluding taking down all as directed and specified.(Make : DANFOS/ LG/ Kirloskar |
| 135 | Supply and replacement ofhermetically sealedreciprocating type compressorfor Refrigerator/Deep Freeze170 to 300 Ltr capacity including taking down.(Make : DANFOS/INDFOS/ LG ) |
| 136 | Repair ofvoltage stabilizerof any capacity ( 1 to 5 KVA) andmake, opening up forinspection/checking serviceability of voltage regulatingtransformer relays, circuitboard, voltmeters,incoming/outgoingconnections etcand reassembling the same with dismantledcomponentafterreplacement of burntspare parts andinternalwiringcompleteall as directed and specified by Engineer-in-Charge.Note.Replacement of spare parts shall be measured and paid separately under items below :- |
| 137 | Supply only transformer of any capacity between 1to 5 KVA including taking down. |
| 138 | Supply only square/ round type voltmeter of size 2\" x 2\" for various voltage stabilizers including taking down. |
| 139 | Supply only circuit board for various capacity of stabilizer including taking down. |
| 140 | Supply only 3 way connector for voltage stabilizer including traking down |
| 141 | M &L forSub main wiring inPVC conduit of required size 2 runof6 sqmm PVC insulated copper conductor cable wih onerun of 6 sqmm PVC insulated copper conductor cable as continuity earth wire, including taking down existing old unsv point wiring ,all as speified and directed . |
| 142 | Servicing of Water purifierincluding replacement of pre Filter and unserviceable components such as PCB and relay , all Filters and membrane, Solenoid-valveand other minor spare parts with connection pipe completeall as directed and specified. (Note : items Such asPCB and relay , all Filters and membrane, Solenoid-valve replaced measured and paid separately. (Make of existing water purifier : Kent, Usha, Aquagard) |
| 143 | Supply only PCB and relay as per existing and all as directed |
| 144 | Supply only all Filters and membrane as per existing and all as directed |
| 145 | Supply only Solenoid valve as per existing and all as directed |
| 146 | Supply only Motor as per existing and all as directed |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy