| 1 | Taking down carefullyCopper/ aluminium point wiringlight, Fan, socket orpower completeincluding fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of wall and ceiling etc all asspecified and directed . |
| 2 | Taking down carefully unserviceable sub main wiring/PVC cable including conduit/casing patti etcall as specified and directed. |
| 3 | Taking down unserviceable DBs any type / size carefully disconnecting and making good disturbed surfaces complete all as all asspecified and directed. |
| 4 | Taking down unserviceable MCB SP/SPN/Isolator/MCCB/RCCBsofany rating & size all as directed and specified. |
| 5 | M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through and including PVC casing & capping fixed on surface wall/ceiling and including modular cover plates and modular flush boxes for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulted unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacess all asspecified and directed.(a)One light point controlled by one 5 Amps one way switch. |
| 6 | (b)One light point controlled by two way switch |
| 7 | (c)One ceiling Fan, Exhaust Fan point controlled by one 5 Amps switch. |
| 8 | (d ) One bell/buzzer point controlled by one bell push button on independent board. |
| 9 | (e)One 3 Pin 6 Amps socket point on the independent board. |
| 10 | (f)One 3 pin 6 Amp socket point on the same board with other switch. |
| 11 | All as perabove item No-5.00but with 2.5 Sqmm cable for 15 Amp switch socket out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all asspecified and directed. |
| 12 | Cutting chases ,pinning in making good to facing where required and pointing in cement motar 1:3 to end or edges of landings,steps, cills,sunshades ,shelves, lintels, etc.and cutting hases for concealed water tubing or concealed water tubing or concealed conduit wiring,etc.and making good cutting exceeding 10cm girth all as specified and directed. |
| 13 | M &L for Point wiring complete with 1.5 Sqmm single core unsheathed PVC insulated 1100 V, FRLS grade with multistranded copper conductor ISI marked drawn through PVC Conduit recess/surface fixed modular cover plates and modular flush boxes for mounting of switches, sockets regulators etc including 1.5 Sqmm PVC insulted unsheathed cable multistranded with copper conductor and connecting to earth dolly for light, fan, plug and bell and making goodthe distributed surfacess completely matched and finished with existing surfacess all as directed and specified by Engr-in-charge.(a)One light point controlled by one 6 Amps one way switch |
| 14 | (b)One ceiling Fan, Exhaust Fan point controlled by one 6 Amps switch. |
| 15 | (c ) One bell/buzzer point controlled by one bell push button on independent. |
| 16 | (d)One light point controlled by 2 Nos,6 amps Two way switch. |
| 17 | (e)One 3 pin socket out let 6 Amp point on independent board |
| 18 | (f)One 3 Pin socket out let 6 Amp point on the same board with other switch. |
| 19 | All as per above item No-8.00but with 2.5 Sqmm cable for 16 Amps switch sockets out let point on independent board including 2.5 Sqmm PVC insulated unsheathed cable multistranded with copper conductor earthing continuity conductor all asspecified and directed. . |
| 20 | Supply and fixing switch piano flushtype , single pole one way 5 Amps all asspecified and directed. |
| 21 | Supply and fixing switch piano flush type , single pole two way 5 Amps all asspecified and directed. |
| 22 | Supply and fixing Bell push flush type SP 5 Amps all asspecified and directed. . |
| 23 | Supply and fixing switch socketcombination out let 5 pin 6 Amps flush type all asspecified and directed. . |
| 24 | Supply and fixing switch socket combination 2 in 1, 5 and 16 Amps flush type all asspecified and directed.. |
| 25 | Supply and fixing modularswitch 6 Amps all asspecified and directed. . |
| 26 | Supply and fixing modularswitch 6 Amps 2 way all asspecified and directed. |
| 27 | Supply and fixing modularswitch 16 Ampsall asspecified and directed. |
| 28 | Supply and fixing Bell pushmodular type SP 6 Amps all asspecified and directed. . |
| 29 | Supply and fixing socketcombination out let 2/3 pin 6 Amps modular type all asspecified and directed. . |
| 30 | Supply and fixing switch socket out let 2 / 3 pin 6 and 16 Amps 2 modular type all asspecified and directed. . |
| 31 | S & Fixfan regulator electronic type volts AC 50 HZ ,4 step, 100 v complete all asspecified and directed . |
| 32 | Supply and fixing ceiling rose ,3 phase ,PVC polycarbonate ,insulated body all asspecified and directed. . |
| 33 | Supply and fix fan regulator electronic 2 modular type volts AC 50 HZ ,100 Watts,4 step complete all asspecified and directed. |
| 34 | Supply and fix call bell (Ding Dong) 240 V, 50 Hz all asspecified and directed. |
| 35 | M&L for lamp holder pendant/angle type insulated body with back plate all asspecified and directed. |
| 36 | Supply and fixing in replacement of existing unserviceable T/L fitting 36/40 W on existing wall withNew LED Batten for LED tube light 18/20 wattswith necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed .Make-Bajaj Cat No BLRB-DB 118 or eqvt make of Havells/PHILIPS/WIPRO/CG |
| 37 | Supply and fixingLED Rod tube light 18/20 wattswith necessary fixing arrangement etc complete all as specifed and directed .Make-Bajaj Cat No BLRB-18W CW LED or eqvt make of Havells/ PHILIPS/WIPRO/CG |
| 38 | Supply and fixing in replacement of existing unserviceable T/L fitting 20 W/Lamp holder on existing wall with LED light fitting 10 watts with LED tube rod, ready to use pack with necessary braket,clamps ,incl. bolts, nuts & washers for fixing arrangement etc complete all as specifed and directed.Make-Bajaj Cat No BCLSB 10 WH or eqvt make of PHILIPS/WIPRO/CG |
| 39 | Supply & fixing of surface mounting round downlight LED 12 watt luminarie complete fittingwith all fixing arrangementall as specifiedand directed . Make-Bajaj Cat No BGSLO SLEEK SURFACE12WWH RDor eqvt make of PHILIPS/WIPRO/CG |
| 40 | Supply & fixing of 30 Watt LED security light fitting with pressure dia cast housing, prismatic, polycarbonate diffuser and IP65 protection with 0.6 mtr long 20/25 mm (as per manufacturer standard)dia GI Pipe in 45 degree bend shape and necessary clamping devices required at site complete all as specifiedand directed . Make-Bajaj Cat No ENXTP 30 L WH CR PC SD or eqvt make of PHILIPS/WIPRO/CG |
| 41 | Supply & fixing of recess mounting 2x2 LEDluminarie, 36 W deep drawn CRCA housing with high power LED premium white powder coated frame blends seamlessly with ceiling layout, suitable for 600x600 mm modular ceiling grid and also can be suspended with provided kit, complete fittingwith all fixing arrangementall as specifiedand directed . Make-Bajaj Cat No BZRSQL GZ1 36W CW or eqvt make of PHILIPS/WIPRO/CG |
| 42 | Supply and fix modular White cover plate with frame, 1 module Make : MK/ CRABTREE / L & T /LEGRAND/roma |
| 43 | supply and fix modular white cover plate with framebut 2 moduleMake : MK/ CRABTREE / L & T /LEGRAND/roma |
| 44 | supply and fix modular white cover plate with framebut 3 module Make : MK/ CRABTREE / L & T /LEGRAND/roma |
| 45 | supply and fix modular white cover plate with framebut 4 module Make : MK/ CRABTREE / L & T /LEGRAND/roma |
| 46 | supply and fix modular white cover plate with framebut 6 moduleMake : MK/ CRABTREE / L & T /LEGRAND/roma |
| 47 | supply and fix modular white cover plate with framebut 8 moduleMake : MK/ CRABTREE / L & T /LEGRAND/roma |
| 48 | M&L for submain wiring alongwith earth wire with the following sizes of FRLSPVC insulatedcopper conductor single core cable , multistrandedon the surface recess through and including suitable size ofPVC casing and capping/PVC conduitwith its accessories all as specified and directedfor the following(a) 2x1.5 sq mm and 1x1.5 sq mm as earth wire |
| 49 | (b) 2x2.5 sq mm and 1x2.5 sq mm as earth wire |
| 50 | (c) 2x4.0 sq mm and 1x4 sq mm as earth wire |
| 51 | (d) 2x6.0 sq mm and 1x6 sq mm as earth wire |
| 52 | (e) 4x6.0 sq mm and 2x4.0 sq mm as earth wire |
| 53 | Supply & fix MCCB DB VTPN 4 ways,with metal double door ,IP -54 protection suitable for MCCB as incommer and MCB as out going, 415 volt 3 phase complete with appropriate size copper bus bar and neutral link confirming to cat part no-5077 50 of legrand complete including cutting chases to wall for fixing of DB and making good distrubed wall/surface all as required at site i.e all asspecified and directed. .Make :Legrand Or eqvt make of /L&T/Siemens. |
| 54 | S & F sheet metal enclosuresDB\"s 2 waySPNsingledoor suitable for 240 Vcompletefixed flush in wall including chases in wall for fixing DB and making good distributed wall surfaces to match with existing specification all asspecified and directed..Make :Legrand Or eqvt make of /L&T/Siemens. |
| 55 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all asspecified and directed. .Make : Legrand Or eqvt make of /L&T/Siemens. |
| 56 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all asspecified and directed. .Make : Legrand Or eqvt make of /L&T/Siemens. |
| 57 | Supply & fix sheet metal enclosure MCB distribution board. Single pole & neutral (SPN) 240 volts 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification all asspecified and directed..Make : Legrand Or eqvt make of /L&T/Siemens. |
| 58 | S & F MCB single pole (SP) 240 volt 06-40 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. Make: Legrand Or eqvt make of /L&T/Siemens. |
| 59 | S & F MCB single pole and neutral (SPN) 240 volt 06-40 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified. Make:Legrand Or eqvt make of /L&T/Siemens. |
| 60 | S & F MCB Tripplepole (TP) 240 volt 40-63 amp for inductive loadconnected through cable lugs of suitable size complete all as directed and specified.Make: Legrand Or eqvt make of /L&T/Siemens. |
| 61 | S & FixMCB Triple pole and Neutral 415 volts, 63Amps, all as specified and as directed. |
| 62 | Supply and fixingSingle pole and nuetral enclouser with two pin and earthplug and socket complete with one single pole MCB with 240 V 20 AMPs.Make:Legrand Or eqvt make of /L&T/Siemens. |
| 63 | M & L for galvanised steel earthing complete with 60 cm x 60 cm x 6 mm thick galvanised steel earth electrode and 04 mmdia galvanised earth lead wire burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to earth lead 4.0 mm dia GI wire protected by 15 mm bore light grade galvanised iron pipe and other and connected to test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron wire mesh, charcoal and common salt in alternater of 15 cm complete thickness all around the GI plate electrode complete with earth pit PCC 1:3:6 type CI and RCC 1:2:4 type B1as in cover 50 mm twice with & including reinforcement with 8mm dia TMT bar at 75 mm spacing both ways andnecesary excavation and earth work in hard/dense soil and disposal of spoilto a distance not exc 50 mtr and necessary testing complete all as shown in electorical plate No 03 connected to earthing test point including taking out old U/S earthing material . |
| 64 | S&FixLED wall mountingLight fitting,14 watt, 230 volts, complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. all as specified & directed.Make :- HavellsCat Part No.LHFOECE1TZ1O014or equivalent model of WIPRO / Philips / Bajaj and Jaquar |
| 65 | Supply & fix LED 9W Tulip LED Bollard for 360 degree light with a modern look using new generation technology in LED to direct light,diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity and as per site requirement of pcc 1:2:4 foundation to installed Bolladd light fitting in the garden all as directed and specified.Make: BajajModel No: BGBOM 650 9W LED WW or equivalentin Wipro /Havells. |
| 66 | Taking down carefully after disconnecting electrical/water supply connections and transporting to the work shop for carry out the servicing / over hauling of the storage type electric water heaters (Geysers) of storage capacity 25 / 50 litres of any make / type by cleaing the inner surface of the tank / heating element with chemical to remove the scaling / rust & reassembling the same after replacing burnt out parts and refixing on its original position including testing complete all as specifed and directed . |
| 67 | Supply & fix replacement heating element of the following ratings as required at site including rubber washer/packing.Make : \"RACOLD/THEETAor equivalent ISI marked. (a) 1.5/2 KW |
| 68 | Supply &fix replacementthermostat stem type suitable for geysers 25 / 50 litres.ISI marked. |
| 69 | Supply &fix replacement 15 mm Heavy duty connecting pipe with two brass adaptors 18 \" long &fixing in position fir cold & Hot water/inlet connection. |
| 70 | Supply & fix in replacement Gun metal Non-Return valve 15mm dia complete all as specified. |
| 71 | Supply &fix replacement indicator lamp rectangular / round type suitable for 25 / 50 litres geysers. |
| 72 | Supply and fix in repair pressure release valve 15mm dia complete all as specified. |
| 73 | Material & labour for painting of storage type water heater any capacity (25/50 litres) after preparation of surface and applying two coats of synthetic enamel paint, white externally complete all as specified. |
| 74 | Taking down the defective ceiling fan of any sweep andmake after disconnecting electrically & mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:-(a)Servicing/overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing. |
| 75 | (b)Re-winding the burnt/short circuited winding with same guage supper enameled copper wire to maintain speed at load. |
| 76 | ( c)Painting of ceiling fan by applying one coats of synthetic enamel paint after preparation of surface complete. |
| 77 | Taking down the repairable exhaust fan of 300 MM / 380 MM sweep, any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically and transporting to the work shop dismantling, examine & carry out the repairs as required and brought back to site, re-fixing, testing in all respect for smooth running and comprising of the following:-(a) Servicing/overhauling the exhuast fan by thoroughly clelaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the resistance value. |
| 78 | (b) Re-winding the burnt/shourt circuited winding with same cauge supper enameled copper wire to maintain speed at load. |
| 79 | (c)Painting of Exhaust fan by applying one coat of synthetic enamel paint after preparation of surface complete. |
| 80 | Supply & replace ball bearings for exhaust/ceiling fan of any sweep. Make : SKF/NBC/FAG |
| 81 | Supply & replace GUN METAL BUSH for exhaust / ceiling fan of any sweep. |
| 82 | Supply and fix in repairs fan condenser of following sizes :-(a) 2.5 mfd |
| 83 | (b) 4 to 6 mfd |
| 84 | Supply anf fix in repair rubber reel, nut bolts, washer, split pin complete set by dismantling existing u/s are as specified. |
| 85 | Supply & Fixin replacementceiling fan down rod of MS pipe 15mm bore 1/1.2 Mtr length including cutting/threading making tide for fixing providing check nuts wachers etc complete. |
| 86 | S & Fix PVC Body Exhaust fan AC single phase 220 to 240 volts 900 RPM of size 200 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 87 | S & Fix PVC Body Exhaust fan AC single phase 220 to 240 volts 900 RPM of size 250 mm sweep with fixed on wall/ventilator andfixing arrangement complete all as specified & directed. |
| 88 | S&F Ceiling fancomplete with all accessories 230 Volts,1200 mmcomplete includingall fixing arrangement all as specified & directed.makeHavells or eqvt in USHA. |
| 89 | Supply & Fix Bulk Head 10 Watt Make Bajaj An ideal energy efficint solution for upgrading conventional GLS bulkhead luminaires to LED bulkhead IP 65 luminaires all as specified & directed. |
| 90 | S & Fix LED RUBY (clear) 25 W LED Post top fitting, IP - 65 new genration, post top,energy saving, environmental friendly, long life aesthetically designed with symmentrical light distribution spun aluminium landscape luminaire with high powder LEDs as light source compartable for all gate piller and including GI pipe required to sizes to fixed at site by growting in wall/roof /piller/boundary wall andPCC foundation as persite requirement. Make :- Havells cat part no - RUBYPT25WLED757PSYMTOPC or eqvt in Bajaj/crompton /wipro |
| 91 | Supply and fix LED bulb /lamp 9w all asspecified and directed |
| 92 | Supply & fix 3 core 1.5 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point all asspecified and directed. |
| 93 | Supply & fix 3 core 4 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point all asspecified and directed. |
| 94 | Supply & fix 3 core 2.5 sqmm PVC insulated Sheathed multicore copper flexible cable connected with existing point all asspecified and directed. |
| 95 | Supply & fix LED step light with die -cast aluminium hosing designed for rugged outdoor usage & IP 65 Protection.Make Bajaj cat part no- BGSBL 9w LED WW or eqvt havells |
| 96 | Supply and fix bottom assemly of geyser any size all asspecified and directed. |
| 97 | Supply only Fix PVC Box of size 4.5\" x 3\" suitable for 15 amp switch-socket |
| 98 | Supply and fix 3 mm thick laminated sheet ISI mark cover fixed with brass screws and cup washers for mounting of plate mounting forhousing the switches, socket outlets, fan regulators etc all asspecified and directed |
| 99 | Supply and fix Double pole 30 mA RCCBs 25A for earth leakage protection all asspecified and directed. |
| 100 | Supply and fix Double pole 30 mA RCCBs 40A for earth leakage protection all asspecified and directed. |
| 101 | To attend any brake down of the summer appliances i.e. split type AC, window type AC , cassete type AC, water coolerand aquaguard of any capacity or make/model/ year if manufacture, installed at DIAT complex as and when required during working /non working hours all as directed by the Engineer-in-charge.Note:- (i) Spares will be measured and paid separately under relevant item (ii)Complaint if not attended with in 24 hours after receiving complaint, penalty will be recovered at double the rate quoted by the contractor |
| 102 | Taking out carefully existing defective sealed compressor of window type AC 1.5/2 ton capacity by dismantling the same, supply and fixing new sealed compressor as per existing model and make including bracing, leak testing, vacuuming charging the oil, refrigerant as required to maintain design grill temperature, testing and commissioning in all respect all as specified and directed by Engineer-in-Charge. |
| 103 | All as per item No 83above but for split type AC 1.5 / 2 ton capacity. |
| 104 | All as per item No 83 above but for storage type water cooler of 40 liters capacity. |
| 105 | All as per item No 83above but for storage type water cooler of 60/150 liters capacity.Note for item No 83 to 86 :- (i)Contractor has to submit certificate issued by dealer for guarantee up to one year including performance of cooling efficiency for new compressor.(ii) Rate quoted deemed to include the cost of compressor oil for topping up and refrigerant.(iii) Spares will be measured and paid separately under relevant items. |
| 106 | M&L for taking down the existing defective fan/ blower motor and transporting to the work shop and dismantled burnt motor, removing the burnt winding & rewinding with super enameled copper wire of suitable size and gauge & replacement of unserviceable bearing of motor of following :-(a) Fan motor (two speed i.e low & high) for window typeAC 1/5 HP. |
| 107 | (b) Condenser fan motor for water cooler 1/6 HP capacity |
| 108 | (c) Condenser fan motor for split type AC unit condensing unit /out door unit) |
| 109 | (d) Blower fan motorfor split type AC unit (indoor/cooling unit)Make :-USHA/ASIAN/TESLA/KELTRON/NEIL |
| 110 | Supply in repairs capacitors of following capacity:-(a) Capacitors 80-100/120 Mfd |
| 111 | (b) Capacitor 36 Mfd |
| 112 | (c) Capacitor 45-65 Mfd |
| 113 | (d) Capacitors 10-25 MfdMake :-USHA/ASIAN/TESLA/KELTRON/EPCOS |
| 114 | Disconnecting and taking out the defective split type AC 1.5/2.0 ton capacity remote circuit complete and supplying and fixing new remote circuit (PCB) as per existing make/model complete all as specified and directed by Engineer-in-Charge. |
| 115 | Removing the damaged PUF insulation of suction pipe and supplying and fixing new thermal sleeve insulation for suction line including providing hard plastic tape over the thermal insulation for split type AC 1.5/2.0 ton capacity etc complete all as directed by Engineer-in-Charge. |
| 116 | Supply and fix in replacement overload protectors relays for the following:-(a) Water cooler |
| 117 | (b)Window type AC |
| 118 | ( c) Split type AC |
| 119 | Taking out defective fan blade and supplying and fixing new blades for water cooler of 40/80/100 liters capacity complete all as directed by Engineer-in-Charge |
| 120 | Taking out defective push cock and supplying and fixing new push cock chromium plated brass, 15 mm bore of approved make for water cooler complete all as directed by Engineer-in-charge. |
| 121 | Taking out old PVC conduit condensation water pipe20mmdia from indoor unit to ground floor by using new PVC conduit ISI mark condensation water pipe 20mm dia, fixing/laying on wall by using clamps and insert into wall by making hole and grouting with cement mortar complete all as specified and as directed by Engineer-in-Charge. |
| 122 | Taking down old metallic socket neutral enclosures single pole with 2 pin and supply and fixing, new single pole and neutral enclosure with 2 pin and earth plug socket complete with one SP MCB-240 volts, 32 amps fixed on sheet metal encloser complete all as specified and directed by Engr-in-Charge. |
| 123 | Taking down window type AC of any capacity / make/ model from existing position and carry out the servicing by cleaning the unit with water, tightening the terminal connections to avoid loose connections, applying the oiling/greasing to fan motor, bearings all as specified for smooth running including cleaning the air filter/check the thermometer setting for 1.5 - 2.0 ton etc. and directed by Engineer in charge. |
| 124 | Taking down from existing position storage type water cooler of any capacity and make and servicing the same by cleaning of water tank, cleaning condensing unit by hand blower and including supply and replacement of damaged aluminium hinges, wiring with PVC insulated copper wire of same gauge, PVC drainpipe 25 mm dia, 1.5 m length, servicing/oiling/greasing of condenser motor with supply and replacement of mounting rubber bushes, tightening of all loose parts, contacts, wiring, nuts, bolts,complete including re-fixing in original position, testing and commissioning to the entire satisfaction of Engineer-in-Charge. |
| 125 | Supply and fix in replacement of relay suitable for water cooler. |
| 126 | Supply and fix in replacement of relay suitable for split type AC of any capacity.Make :- USHA/SHRIRAM/ ANNAPURNA |
| 127 | Supply and fix in replacement of air filter pad for window type |
| 128 | Supply and fix in replacement of outer casing for window AC 1.5 TR. |
| 129 | Supply and fix in replacement of front grill for window AC ofsuitable size/ shape / modelas required at site. Make :-VOLTAS / LG |
| 130 | Supply and fix in replacement of auto cut thermostat for window type AC / split type AC. |
| 131 | Supply and fix in replacement of auto cut thermostat for water cooler. |
| 132 | Supply and charging / topping up refrigerant R-404,R-134Ato window type / split type AC as directed by Engineer-in-charge. |
| 133 | Supply and charging / topping up oil to window type / split type AC and Water cooler compressorsas directed by Engineer-in-charge. |
| 134 | Detecting of gas/refrigerant leakage in the system by pressure testing withnitrogen gas and rectifying the same by brazing if required replace the copper tube as required and vacuumising, recharging of refrigerant F-22 /F-12/Refron/Mafron as recommended by manufacture to maintain the design grill temperature by testing & commissioning including changing of compressor oil (CAPILA-D) for window type AC 1.5/2 TR capacity complete all as specified and directed by Engineer-in-Charge. |
| 135 | All as per item No 107 here in before but for split type A/C 1.5/2/3 TR capacity. |
| 136 | All as per item No 107 here in before but for water cooler any type/capacity. |
| 137 | Supply and charging / topping up refrigerant R-134 to water cooler as directed by Engineer in charge. |
| 138 | M&L for painting out door unit of 1.5/2.0/3.0 Ton capacity split type A/C by one coat of spary painting using super enamel paint over one coat of anticorrosive primer including preparation old surfaces by scraping etc complete all as specified and directed by Engineer-in-Charge |
| 139 | Taking down the defective voltage stabilizer 5/4 KVA, carry out the repair by replacing the unserviceable parts & refixing the same including testing.(a)Volt meter (As per sample) |
| 140 | (b) Indication lamp |
| 141 | (c)PCB |
| 142 | (d) Transformer rewinding |