Annual Rate Contract For Extraction, Loading, Unloading And Lowering Of Submersible Pumpset, Vt Pumpset, Pumpset Of Dug Wells With Allied Works- 1 Disconnecting Of Power Connections From Starter Panel, Disengaging From Delivery Bend And Extracting Out Submersible Pump Set Complete Along With Column Pipes By Hoisting Chain Pulley Block At Tube Well, Stacking Of Column Pipes And Submersible Cable Properly And Dismantling Of Nrv. 2 For 2.5 Inch Dia To 4 Inch Diacolumn Pipes 3 0 To 10 Column Pipes 4 11 To 20 Column Pipes 5 21To 30 Column Pipes 6 31To 40 Column Pipes 7 41 & Above Column Pipes 8 For 5 Inch Dia To 8 Inch Diacolumn Pipes 9 0 To 10 Column Pipes 10 11 To 20 Column Pipes 11 21To 30 Column Pipes 12 31To 40 Column Pipes 13 41 & Above Column Pipes 14 Loading Of Submersible Pump / Motor In Mechanical Transport, Carriage To The Workshop And Unloading At Workshop. 15 0 To 10 Kilometer 16 11 Kilometer & Above 17 Loading Of Submersible Pump / Motor In Mechanical Transport And Carriage Back To Site Of Work And Unloading At Site. 18 0 To 10 Kilometer 19 11 Kilometer & Above 20 Making Of Cable Connection Of Motor With Submersible Cable After Dressing Cable Ends Properly. Making Of Each Joint Water Proof. Lowering Of Submersible Pump Set Complete Along With Column Pipes And Submersible Cable With Providing & Fitting Of Jointing Material And Nuts And Bolts. Making Of Connections To The Starter Panel. 21 For2.5 Inch Diato 4 Inch Diacolumn Pipes 22 0 To 10 Column Pipes 23 11 To 20 Column Pipes 24 21To 30 Column Pipes 25 31To 40 Column Pipes 26 41 & Above Column Pipes 27 For5 Inch Dia To 8 Inch Diacolumn Pipes 28 0 To 10 Column Pipes 29 11 To 20 Column Pipes 30 21To 30 Column Pipes 31 31To 40 Column Pipes 32 41 & Above Column Pipes 33 Vt Pump 1.80Lac. Gph X 34.5 Mtr. 34 Disconnecting Of Power Connections From Starter Panel, Dismounting Of Motor Using Special Tools And Tackles, Skilled Man Power, After Disengaging The Coupling Pulley Set. 35 Disengaging From Delivery Bend And Extraction Of Vt Pump Set Complete Including Liner Assembly And Pump Assembly Using Special Tool And Tackles, Skilled Manpower, Stacking Of Pump Parts, Cables. 36 Loading Of Vt Pump / Motor Into Mechanical Transport And Carriage To Workshop And Unloading Thereof. 37 Loading Of Vt Pump / Motor Into Mechanical Transport And Carriage From Workshop And Unloading At Site. 38 Lowering Of Vt Pump Set Complete Including Linear Assembly With Proper Alignment, Fitting Of Discharge Head, Delivery Line, Packing Box, Ratchet Assembly, Coupling Pulley. 39 Mounting Ofmotor Using Special Tools, Tackles And Skilled Labour. Coupling Ofmotor. Making Of Connections With Starter Panel. 40 Vt Pump 1.50 Lac Gph X 45 Mtr. 41 Disconnecting Of Power Connections From Starter Panel, Dismounting Of Motor Using Special Tools And Tackles, Skilled Man Power, After Disengaging The Coupling Pulley Set. 42 Disengaging From Delivery Bend And Extraction Of Vt Pump Set Complete Including Liner Assembly And Pump Assembly Using Special Tool And Tackles, Skilled Manpower, Stacking Of Pump Parts, Cables. 43 Loading Of Vt Pump / Motor Into Mechanical Transport And Carriage To Workshop And Unloading Thereof. 44 Loading Of Vt Pump / Motor Into Mechanical Transport And Carriage From Workshop And Unloading At Site. 45 Lowering Of Vt Pump Set Complete Including Linear Assembly With Proper Alignment, Fitting Of Discharge Head, Delivery Line, Packing Box, Ratchet Assembly, Coupling Pulley. 46 Mounting Ofmotor Using Special Tools, Tackles And Skilled Labour. Coupling Ofmotor. Making Of Connections With Starter Panel. 47 Vt Pump 0.55 Lacs Gph X 30 Mtr. 48 Disconnecting Of Power Connections From Starter Panel, Dismounting Of Motor Using Special Tools And Tackles, Skilled Man Power, After Disengaging The Coupling Pulley Set. 49 Disengaging From Delivery Bend And Extraction Of Vt Pump Set Complete Including Liner Assembly And Pump Assembly Using Special Tool And Tackles, Skilled Manpower, Stacking Of Pump Parts, Cables. 50 Loading Of Vt Pump / Motor Into Mechanical Transport And Carriage To Workshop And Unloading Thereof. 51 Loading Of Vt Pump / Motor Into Mechanical Transport And Carriage From Workshop And Unloading At Site. 52 Lowering Of Vt Pump Set Complete Including Linear Assembly With Proper Alignment, Fitting Of Discharge Head, Delivery Line, Packing Box, Ratchet Assembly, Coupling Pulley. 53 Mounting Ofmotor Using Special Tools, Tackles And Skilled Labour. Coupling Ofmotor. Making Of Connections With Starter Panel. 54 Dug Wells 55 Disconnecting Of Power Connections From Starter Panel, Disengaging From Delivery Bend And Extracting Outpump Set Complete Along With Column Pipes By Hoisting Chain Pulley Block. Stacking Of Column Pipes And Cable Properly. 56 Loading Of Pump / Motor In Mechanical Transport, Carriage To The Workshop And Unloading. 57 0 To 10 Kilometer 58 11 Kilometer & Above 59 Loading Of Pump / Motor In Mechanical Transport And Carriage Back To Site Of Work And Unloading At Site. 60 0 To 10 Kilometer 61 11 Kilometer & Above 62 Making Of Cable Connection Of Motor With Cable After Dressing Cable Ends Properly. Making Of Each Joint Water Proof. Lowering Of Pump Set Complete Along With Column Pipes And Cable With Providing & Fitting Of Jointing Material And Nuts And Bolts. Making Of Connections To The Starter Panel.