Supply Of Ct And Cvt At Grid Station Hiranagar. Supply Of Ct And Cvt At 320 Mva, 220 / 132 / 66 Kv Grid Station Hiranagar. , Supply Of Single Phase 50 C / S 245 Kv Ct ( 1200-800-400 / 1A ) 5 Core Or As Per Site Specification 40 Ka For One Second Rated, narwal-Jammu And Kashmir

Power Development Department has published Supply Of Ct And Cvt At Grid Station Hiranagar. Supply Of Ct And Cvt At 320 Mva, 220 / 132 / 66 Kv Grid Station Hiranagar. , Supply Of Single Phase 50 C / S 245 Kv Ct ( 1200-800-400 / 1A ) 5 Core Or As Per Site Specification 40 Ka For One Second Rated. Submission Date for this Tender is 07-03-2022. Transformer Supply Tenders in narwal Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30548546
Corrigendum : Supply Of Ct And Cvt At Grid Station Hiranagar. Supply Of Ct And Cvt At 320 Mva, 220 / 132 / 66 Kv Grid Station Hiranagar. , Supply Of Single Phase 50 C / S 245 Kv Ct ( 1200-800-400 / 1A ) 5 Core Or As Per Site Specification 40 Ka For One Second Rated
Open Tender
Indian
Jammu And Kashmir
Narwal
07-03-2022

Tender Details

Supply Of Ct And Cvt At Grid Station Hiranagar. Supply Of Ct And Cvt At 320 Mva, 220 / 132 / 66 Kv Grid Station Hiranagar. , Supply Of Single Phase 50 C / S 245 Kv Ct ( 1200-800-400 / 1A ) 5 Core Or As Per Site Specification 40 Ka For One Second Rated Dynamic Current 100 Ka ( Peak ) Class A Insulation Burden20va. , Supply Of Single Phase 50 C / S 145 Kv Ct ( 1200-600-300 / 1A ) 5 Core Or As Per Site Specification 31.5 Ka For One Second Rated Dynamic Current 100 Ka ( Peak ) Class A Insulation Burden20va. , Supply Of Single Phase 50 C / S 72.5 Kv Ct ( 600-300-150 / 1A ) 4 Core Or As Per Site Specification 31.5 Ka For One Second Rated Dynamic Current 80 Ka ( Peak ) Class A Insulation Burden20va. , Supply Of Single Phase Outdoor, Oil Immersed 245 Kv, 3 Core Cvt ( 220 / 1.732 ) Kv / ( 110 / 1.732 ) V With Nominal Systen Voltage 220 Kv, 50 Hz, System Fault Level For 40 Ka For 1 Sec To Class A Insulation Burden 50Va ( Min ) , Accuracy Class 0.2S For Metering And 3P For Protection As Per Is:3156 / Iec 186. , 220 Kv Transformer Bushing For 160 Mva ( Make Bhel, Indo Tech ) , 133.33 Mva ( Make Bhel ) , 120 Mva ( Make Cgl ) , 200 Mva ( Make Alstom, Imp, Toshiba ) , 245 Kv Single Phase 50C / S Potential Transformer Including First Fill Of Transformer Oil Plus Extra 10% Complete In All Accessories Etc Of Reputed Make. , 220 Kv Isolator ( 1600 Amps ) Gr Power Switch Gear , 132 Kv Level , 132 Kv 3 Pole, Sf6 Gas Filled, Outdoor Circuit Breaker With Operating Mechanis, All Accessorie, Auxillaries And Marshalling Boxes / Kiosks, Sf6 Gas ( First Filling Plus 10 Kg Cylinder Additional ) Along With Supporting Structures And Clamps. , 132 Kv Lightning Arrestor ( 1-Phase, 50C / S, Outdoor Metal Oxide Gapless Type Including Surge Counters / Monitors ) , Current Transformer Single Phase Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories Etc Complete In All Respect 145 Kv ( 800-400-200 / 1-1-1-1-1 ) Of Mehru / Pragiti / Other Reputed Make. , Current Transformer Single Phase Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories Etc Complete In All Respect 145 Kv ( 1200-600-300 / 1-1-1-1-1 ) Of Mehru / Pragiti / Other Reputed Make. , Current Transformer Single Phase Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories Etc Complete In All Respect 145 Kv ( 1200-600-400 / 1-1-1 ) Of Mehru / Pragiti / Other Reputed Make. , 132 Kv Transformer Bushing For 160, 150, 133.33, 50, 20Mva Transformers Of Cgl, Emco, Imp, Ece, Gec Alstom, Bharat Bijlee, Indotech, Areva, Abb Make. , 132 Kv Isolators 50 C / S 1600 Amps, 31.5 Ka For One Second, Ac Motor Operated Horizontal Double Break, Outdoor Type Isolator With All Acessories Including Solid Core Post Insulators, Auxillaries, Marshalling Boxes, Clamps Completed In All Respect. , 132 Kv Pt Along With Clamps For Moose Rated Voltage Primay Equal To ( 132 / V3 ) Kv Rms.No Of Secondaries Equal To 3, Rated Secondary Voltage For I / Ii / Iii Secondary Equal To ( 110 / V3 ) , Post Insulators 145 Kv Outdoor Type , Bucholz Relay Bhel Make , 132 Kvline Control And Relay Panel For 132 Kv Gladini Kalakote Transmission Line. , 33 Kv Level , 33 Kv Breaker ( Outdoor ) 1250 Amp With Offered Operating Mechanism All Accessories Auxillaries And Marshalling Boxes / Kiosks Etc Complete In All Respects With Spare Vaccum Bottle. , 33 Kv Lightning Arrestor Single Phase, 50C / S, Outdoor, Metal Oxide Gapless Type Arrestor Insulating Base And All Associate Accessories, Auxillaries, Complete In All Respects. , 33 Kv Pt / Cvt Single Phase 50C / S Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories Complete In All Respect. , 33 Kv Isolator Without Earth Blade 1250 Amps. , 33 Kv Isolator With Earth Blade 1250 Amps. , 33 Kv Ct Single Phase 50C / S Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories, Auxilaries Etc Complete In All Respect ( 1200-600-300 ) 5 / 4 / 3-Core Of Reputed Make , 33 Kv Ct Single Phase 50C / S Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories, Auxilaries Etc Complete In All Respect ( 800-400-200 ) 5 / 4 / 3-Core Of Reputed Make , 33 Kv Transformer Bushing For 50 And 20 Mva Transformers Of Cgl, Emco, Imp, Ece, Gec Alstom Make. , 33 Kv Bushing Of 50 Mvapower Transformer Vijay Make. , Post Insulator 36 Kv Outdoor Type , Neutral Current Transformer ( 1200-800-400 / 1-1-1 ) Mehru / Pragati Make , 66 Kv Level , 66 Kv Isolator ( 3 Pole With One Earth Switch ) 50C / S 1600 Amps, 31.5Ka For One Second, Ac Operated Horizontal Double Break, Outdoor Type Isolator With All Accessories Including Solid Core Post Porcelin Insulator, Auxillaries, Marshalling Boxesother Essentials Complete In All Respect. , 66 Kv Transformer Bushing For 20Mva ( Bharat Bijli ) / 50Mva ( Vijay Make ) . , 66 Kv Current Transformer Single Phase, 50C / S Current Transformer Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories, Auxillaries Etc Complete In Alrespects ( 600-300-150 / 1-1-1 ) . , 66 Kv Current Transformer Single Phase, 50C / S Current Transformer Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories, Auxillaries Etc Complete In Alrespects ( 600-300-150 / 1 ) . , 66 Kv Current Transformer Single Phase, 50C / S Current Transformer Including First Fill Of Transformer Oil Plus 10% Extra And All Accessories, Auxillaries Etc Complete In Alrespects ( 400-200-100 / 1-1-1 ) . , 66 Kv Pt / Cvt Single Phase 50C / S Potential Transformer Including First Fill Of Transformer Oil Plus 10% Extra And All Acessories, Auxillaries Etc Complete In All Respect. , 66 Kv Lightning Arrestor Single Phase, 50C / S, Outdoor, Metal Oxide Gapless Type Arrestor Insulating Base And All Associate Accessories, Auxillaries, Complete In All Respects. , 66 Kv Sf6 Breaker 1600 Ampsof 3 Phase 50C / S And 31.5Ka ( Rms ) For 3 Sec.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 07-02-2022 2nd Extension Date 18-02-2022
2 21-01-2022 Extension Notice Date 04-02-2022
3 23-02-2022 3rd Extension Notice. Date 07-03-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 19380.0 /-
Tender Value
INR 9.69 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail