Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes-Goa

Department of Defence Production has published Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes. Submission Date for this Tender is 25-01-2022. Kitchen Equipment Tenders in Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30477922
Corrigendum : Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes
Indian
Goa
25-01-2022

Tender Details

Bids Are Invited For Icaf System ( M / S Sargam Metal, Chennai ) - Lb 5004Whr Sea Chest Icaf Anode Cable Defective. Cable To Be Renewed Alongwith Replacement Of Anode During Dry Docking Of Ship.Gsl Remarks:Do Renewal Of Cable. Renewal Of Anodes Under Aiamc. Cable Length – 02 Mtrs, Size – 2.5 Mm2 X 3 Core. Material – Firm Supply.All In Way Jobs Included.Cable - Firm Supply , Main Switch Board ( Port & Stbd ) Qty-02 Nos And Emergency Switch Board ( M / S Rrmi ) Qty-01 No Pms ( Port & Stbd ) ( M / S Deif Qty -02 Nos ) Pac Firm M / S Rrmi For Msb And M / S Deif For Pms - La 5033The Following Instrument / Measuring Device Of Both Main Switch Boards And Em. Switch Board To Be Calibrated And Limits To Be Red Marked. Calibration Certificate To Be Handed Over To Ship Staff. ( Maintenance Schedule No. Lp-05 ) Sldescriptionrangeqty ( A ) Voltmeter0 – 300 V3 ( B ) Voltmeter0 – 600 V10 ( C ) Insulation Meter0-Infinite7 ( D ) Ammeter0 – 1000 A3 ( E ) Ammeter0 – 1600 A1 ( F ) Ammeter0 – 2000 A3 ( G ) Ammeter0 – 6000 A12 ( H ) Ammeter0 – 10000 A6 ( J ) Frequency Meter45 Hz – 55 Hz10 ( K ) Kw Meter0 To 200 Kw1 ( L ) Kw Meter-50 To 500Kw 1 ( M ) Kw Meter -150 To 1500 Kw6 ( N ) Kw Meter-2875 To 2875 Kw3 ( P ) Synchroscope-- 7 ( Q ) Power Factor Meter 0-1-0 10 ( R ) Phase Sequence Meter --1Gsl Remarks:Do.Spares – Cg Supplymaterial – Firm Supplyfirm To Provide Calibration Certificate & Safety Check Report. All In Way Jobs Included. , Shore Connection Box ( M / S Marine Electrical ( 02 Nos ) - La 5142Calibrate Following Instrument. Calibration Certificate To Be Handed Over To Ship. ( Maintenance Schedule No. Lp-10 ) .Sldescription Specification Qty ( A ) Volt Meter0-500 V02 No. ( B ) Ammeter 0-1000 A02 No. ( C ) Phase Sequence Meter -- 02 No. ( D ) Power Factor Meter -- 02 No.Gsl Remarks:Dospares – Cg Supplymaterial – Firm Supplyall In Way Jobs Included.Calibration Certificate To Be Provided By Firm. , Shore Connection Box ( M / S Marine Electrical ( 02 Nos ) 1 - La 5143Overhaul Shore Distributionconnection Box Consist Of Contactor ( 3Tf-6844-Oc ) , Qty – 02 Nos, Calibrate 01 No. Voltmeter, Range 0-600V, And 02 Nos Current Transformers.Renewdefectivemeter.Calibrationcertificatewithlimitstobe Handed Over To Ship.Gsl Remarks:Dospares – Cg Supplymaterial – Firm Supplyall In Way Jobs Included.Calibration Certificate To Be Provided By Firm. , Galley Equipment ( M / Sdenki & Sushma Electricals, Mumbai ) - La 5149Overhaulfollowinggalleyequipmentmotor.Overhaulingincludesrecordof Insulation Prior Dismantling Of Motor And Withdrawal Of Rotor, Renewal Of De / Nde Ball Bearing On Dismantling Of Motor, Spray Painting Of Heat Resistive Paint On External / Internal Part Of Yoke, Apply Of Varnish And Baking Up For 10 Hour. Renewal Of All Consumable Associated With Motor ( Cooling Fan, Foundation Nut, Bolt, Screw, Junctioncoverwithgasketandterminalstrip ) .Recordingof Insulation, Starting / Running Current And Proving Of Motor For Satisfactory Operation On Completion Of Overhauling. ( Maintenance Schedule No. Lp-55 & 56 ) . All Materials / Spares To Be Supplied Under Scope Of Firm.Slequipment Motor Specificationqty ( A ) Electric Meat Mincer 230V, 0.75 Kw1 ( B ) Heavy Duty Grinder230 V, 1.5 Kw 1 ( C ) Dough Mixture415v, 1.5 Kw1 ( D ) Potato Peeler 415V, 1.5 Kw 1Gsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included. , Battery Charger ( M / S Marine Electrical ) - La 5154Overhaul 08 In No Battery Charger 230 V To 24 V Dc, Capacity, 60A. Overhauling Includes Cleaning / Functional Check Of Single Phase Double Wound Transformer, 230 V To 40 V, 50Hz, 2.5 Kva Qty-06 No, Single Phase Scr Controlled Bridge Rectifier 24 V, 75A, Qty-08 No, Single Phase Scr Controlled Sensing Circuit 230 V 1Ph 50 Hz, Qty-08 No, Diode ( S4hr63 ) 63A, Qty- 08 No. Calibrate Volt Meter ( Size – 96X96 Mm ) , 0-50V Dc Heaving Red Mark Of 24 V Dc Qty-08 No, Ammeter ( Size – 96X96 Mm ) 0-75 A Dc R / M 60A With External Shunt 75 Mv, Qty-08 No. Renew All Defective / Deterioratedcomponentsandcableterminalconnector.Calibration Certificate With Limits To Be Handed Over To Ship Staff. ( Maintenance Schedule No. Lp-50 ) .Gsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included. Calibration Certificate To Be Provided By Firm. , Battery Charger ( M / S Marine Electrical ) 1 - La 5155Overhaul 02 In No Portable Battery Charger 24 V, Capacity – 20 A. Overhauling Includes Cleaning / Functional Check Single Phase Double Wound Transformer, 230 V To 40 V, 50Hz, 1000 Va, Qty-02 No, Single Phase Scr Controlled Bridge Rectifier 24 V, 50A, Qty-02 No, Single Phase Scr Control And Sensing Circuit 230 V 1Ph 50 Hz, Qty-02 No, Diode ( S2hr40 ) , 40A, Qty 02 No. Calibrate Volt Meter ( Size 96X96 Mm ) 0-50V Dc Heaving Red Mark At 24 V Dc, Qty-02 No.Ammeter ( Size – 96X96 Mm ) , 0-75 A Dc R / M 30A With External Shunt 75 Mv, Qty-02 Nos. Renew All Defective / Deteriorated Components And Cable Connector. Calibration Certificate With Limits To Be Handed Over To Ship Staff. ( Maintenance Schedule No. Lp-50 ) . Gsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included.Calibration Certificate To Be Provided By Firm. , Aerials - La 5218Sldescription Of Whip Aerial Qty ( A ) Vhf Rt & , Dsc , 5022 4 ( B ) Ais ( Gps &Vhf ) 2 ( C ) Aero Vhf1 ( D ) 1Kw Mf / Hf Tx / Rx Codan1 ( E ) 100W , Hf / Rx Tr 2400 1 ( F ) Ndb 1 ( G ) Dsc Watch Receiver, 2187.5Khz2 ( H ) Dsc Watch Receiver Ch-70, 6000A2 ( J ) Vlf / Hf Duplexreceivers Ek 8962 ( K ) Mss Tx / Rx2 ( L ) Navtex Receiver 1 ( M ) Fbb 150 1Gsl Remarks:Do Only Paint Of Aerials. Rf Paint - Firm Supply.Quantity Of Paint – 40 Ltrsremaining Scope Of Job By Ss / Underdfp. , Miscellaneous:- - Lb 5221Galley Hot Plate – 02X 5Kw Galley Plate Base Deformed And Inclined. Deformed Base To Be Repaired And Re-Fabricated So To Remove Inclination. Cabling Inside Structure / Beneath Hotplate Elements Deteriorated, Cabling To Be Replacedgsl Remarks:Do.Spares – Cg Supply. Material – Firm Supply.All In Way Jobs Included. , Window Wiper ( Make- M / S Jung-A Marine ) - Lb 5224Repair Essential On 04 In Nos. Window Wiper Motor 230V, 1Phase, 50Hz, ( Make- M / S Jung-A Marine ) And 02 In Nos. Control Panel ( Lso & Bridge ) View Motors Getting Stuck Intermittently During Operation And Gears Getting Slipped.Gsl Remarks:Do.Spares & Material – Firm Supply. All In Way Jobs Included. , Bilge Sensor - Lb 522514Bilgesensorshingesandjunctionboxesfittedinconfinedspaces / Bilges Deteriorated / Rusted To Be Renewed.Gsl Remarks:Do.Spares & Material – Firm Supply. All In Way Jobs Included. , Water Tight Sliding Door - Lb 5226Intermittent Failure Of Plc For Water Tight Sliding Door Indication On Ipms. View Failure Of Plc, Operation, Not Available From Ipms. Plc To Be Reprogrammed / Repaired.Gsl Remarks:Do.Spares & Material – Firm Supply. All In Way Jobs Included. Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 10-01-2022 17-01-2022
2 17-01-2022 18-01-2022
3 18-01-2022 19-01-2022
4 24-01-2022 25-01-2022

Key Value

Document Fees
Refer document
EMD
INR 62500.0 /-
Tender Value
Refer document