Bids Are Invited For Serviceability Checks/ Overhaul Of Electronic Equipment - (A) Clean Dust, Dirt And Moisture From The Internal And External Surface Of The Units. (B) Check Connectors For Proper Mating And Grounding. (C) Clean All Pcbs/ Modules And Check For Correct Functionality. Procure And Renew If Faulty.(D) Smps/ Power Supply Unit To Be Checked For Rated Input/ Outputs. Renew If Faulty.(E) Systems Having Software To Be Checked For Correct Functionality. (F) Check The Cable And Connectors For Cuts, Corrosion Or Undue Strain. (G) Clean The Air Filter With Vacuum Cleaner As Applicable.(H) Check The Set For Optimum/ Designed Performance And Reliability. (J) Replace The Defective Lamps/Caps/ Fuses/ Hinges/ Screws/ Knobs/ Keys/ Switches. (K) All Existing Shock Mounts / Base Plates / Foundations To Be Checked For Integrity And Renew If Necessary.(L)Renew All Earthing/ Bonding Straps. (M) Renew All Terminal Lugs(N) Renew Of Emi/ Emc Gaskets Of All Openings Of Equipment.(P)Interfacing To All Systems To Be Proved As Applicable.(Q) Carry Out All Annual Routines And Performances Tests As Per Maintop At Shop Floor , Overhaul Of Antennas And Aerials - (A) Clean And Examine Whip And Wire Aerials For Pitting /Cavities, Replace All Defcetive Components. Apply Rf Paint To Antennas.(B) Check Insulation Of Wire Aerial, Value Should Be More Than 2 Mega Ohms,If Strands Are Cut/ Broken To Be Replaced.(C) Renew Porcelean Insulators Of Wire Aerial If Required.(D) Replace Insulator Of Antenna If Defective(E)Base Plate Of Antenna Is Corrodedto Be Manufactured And Fitted. (F)Work Includes Removal/Refitment Of Antenna. (G) Antenna Foundation Box Is Corroded,To Be Removed And New Box As Per Original Dimensions To Be Manufactured And Fitted/ Welded On The Respective Antenna Place. , Rukmani - Make : Bel Oems Local Representative : Bel,Gaziabad Quantity : 01Overhauling Of Complete System As Per Sow 3. , 1 (Rukmani) - Fabircation Of Base Plate For Vce , Provision For Power Supply To Vce.Cabling, Degutting , Regutting, Opening Of Pannels And Cable Glands. , 2 (Rukmani) - Lan Cable From Ops Room To Mco Perished Showing Low Insulation To Be Replaced. , 3 (Rukmani) - Analog Phone Cable From Ops Room To Co Cabin And Bridge, Perished To Be Renewed. , 4 (Rukmani) - Position Feed From Gps Not Getting Updated In Ccu.Defect To Be Rectified. , 5 (Rukmani) - Metallic Conduit For Cables Of Gps And Ku Band Antennaat Bridge Top Perished To Be Renewed. , 6 (Rukmani) - Performance And Serviceability Checks/Repair Of All The Sub-Units Renew If Defective. Scope Of Work Involves The Following:-(I) Removal Of Units, Cleaning And Renewal Of Contacts/Connections , Overhauling Of Antenna As Per Sow 5 ,Removal Of Both Ku And C Band Antenna And Radome At Shop Floor And Keep It At Yard Till Refit. ,Inspect Connections For Insulation And Chaffing And Frayiing, Electrolyte Capacitors For Leakage, Printed Circuit Board For Signs Of Deterioration, Battery Case For Signs Of Deterioration. Repair/ Replace If Necessary,Buc (Block Up Converter) 16 W, Servo Drive Modules& Single Board Controller,,Power Supply Unit& Inertial Measurement Unit,, Central Control Unit & Modem (Hx 260), Front & Rear Panel) , 7 (Rukmani) - 6Kva Ups And Battery To Be Procure And Replace. Ups-1 Battery -26 Ah (Qty 16) , Mandotary Spares (Abg229a0043) - 16 W Ku Band Lbuc , (B239498e0024) - 20W C Band Lbuc , (13N132702236) - Lnb C Band , 11020023 - Lnb Ku Band , 1 (Na) - 7.5 Kva Online Ups , 2 (Na) - 12V, 28 Ah Battery Total Quantity : 1