Hdr Brachytherapy Unit Hdr Brachytherapy Unit , Hdr Brachytherapy With Treatment Planning System With All Acessories Mentioned In The Technical Specifications Including 1 Source ( Basic Price In Column M To Be Offered In Usd, Others In Inr ) . , Rate Of One Source Rate Shall Be Inclusive Of Insurance And Freight Cost For Both Onward And Return Of Used Sources. The Rate Offered Will Be Taken For Evaluation. ( Basic Price In Column M To Be Offered In Usd, Others In Inr ) . , Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared , Cutting Branches Of Trees Overhanging Above Any Structures Of Girth Between 40Cm To 60Cm Including Stacking Of Serviceable Materials And Disposal Of Unserviceable Material, Cost Of Labour, Hire Charges Of Rope And Pully Etc Without Making Any Damages To Nearby Structures Etc Complete , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth, Lead Up To 50 M And Lift Up To 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed. All Kinds Of Soil , Excavation Work By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soils As Directed, Within A Lead Of 50 M. Ordinary Rock , Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. , Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified. Chlorpyriphos / Lindane Emulsifiable Concentrate Of 20% , Diluting And Injecting Chemical Emulsion For Post -Constructional Anti-Termite Treatment ( Excluding The Cost Of Chemical Emulsion ) : Along External Wall Where The Apron Is Not Provided Using Chemical Emulsion @ 7.5 Litres / Sqm Of The Vertical Surface Of The Substructure To A Depth Of 300Mm Including Excavation Channel Along The Wall & Rodding Etc. Complete: With Chlorpyriphos / Lindane E.C. 20% With 1% Concentration , Plain Cement Concrete : Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: 1:2:4 ) 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 40 Mm Nominal Size ) , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level: 1:2:4 ( Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , Reinforced Cement Concrete : Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But , Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. All Works Up To Plinth Level : , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But , Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. All Works Above Plinth Level Up To Floor V Level : , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For : Foundations, Footings, Bases For Columns. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For : Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For : Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For : Columns, Pillars, Piers, Abutments, Posts And Struts. , Reinforcement : Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Up To Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. , Masonry : Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) Up To Plinth Level With: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) ( From Floor 2 Level Up To Floor 5 Level ) , Flooring: Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600 X 600 Mm. , Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete , Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., ., Complete. , Providing And Laying Vitrified Tiles Indifferent Sizes ( Thickness To Be Specified By Manufacturer ) , With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) , Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete. Size Of Tile 600X600 Mm ( For Walls ) , Plastering : 12 Mm Cement Plaster Of Mix : 1:6 ( 1 Cement: 6 Fine Sand ) , 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix: 1:3 ( 1 Cement : 3 Fine Sand ) , 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement: 5 Coarse Sand ) Finished With A Top Layer 6Mm Thick Cement Plaster 1:6 ( 1 Cement: 6 Fine Sand ) . , Finishing : Finishing Walls With Premium Acrylic Smooth Exterior Paint With Silicone Additives Of Required Shade New Work ( Two Or More Coats Applied @ 1.43 Ltr / 10 Sqm. Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) . , Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface : Water Thinnable Cement Primer. , Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade: Two Or More Coats On New Work , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work. , Polishing On Wood Work With Ready Mixed Wax Polish Of Approved Brand And Manufacture: New Work , Joineries : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) . Second Class Teak Wood , Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embeddings In Cement Concrete Block 30X10x15 Cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) , Providing And Fixing Panelled Or Panelled And Glazed Shutters For Shutters For Doors, Windows And Clerestory Windows, Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessery Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer - In-Charge. Second Class Teak Wood , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) . Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Providing And Fixing 12Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is:12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer-In-Charge. Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side. , Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness , Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) With Necessary Accessories And Screws Etc. Complete. , Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 150X10 Mm , Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete : 250X10 Mm , Providing And Fixing 100Mm Brass Locks ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete , False Ceiling: Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5Mm Dia X 50Mm Long With 6Mm Dia Bolts Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts &Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Rate Of 1200Mm Centre To Centre To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size3.5 X 25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound , Jointing Tapes , Finishing With Jointing Compound In 3Layers Covering Upto 150 Mm Or Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per Manufactures Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With : 12.5 Mm Thick Tapered Edge Gypsum Plain Board Conforming To Is: 2095- Part I. , Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams Per Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85X 30X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer -In-Charge. 12.5 Mm Thick Square Edge Pvc Laminated Gypsum Tile Size 595X595 Mm Made Of Gypsum Plasterboard , Manufactured From Natural Gypsum As Per Is 2095 Part I And Laminated With White 0.16 Mm Thick Fire Retardant Pvc Film On The Face Side And 12 Micron Metalized Polyster On The Back Side With All Edges Sealed With The Face Side Pvc Film Which Goes Around And Wraps The Edges And Is Bonded To The Edges And The Back Side Metalized Polyster Film So As To Make The Tile A Completely Sealed Unit , Providing And Fixing Tiled False Ceiling Of Approved Materials Of Size 595 X 595 Mm In True Horizontal Level, Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanized Steel Sections ( Galvanized @ 120 Grams Per Sqm, Both Side Inclusive ) Consisting Of Main T Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38 Mm Made From 0.30 Mm Thick ( Minimum ) Sheet, Spaced At 1200Mm Center To Center And Cross T Of Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet, 1200 Mm Long Spaced Between Main T At 600 Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross T Of Length 600 Mm And Size 24X25 Mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600 Mm Panel To Form Grids Of 600X600 Mm And Wall Angle Of Size 24X24x0.3 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Required Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main T Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Of Size 27 X 37 X 25 X 1.6 Mm Fixed To Ceiling With 12.5Mm Dia And 50 Mm Long Dash Fasteners, 4 Mm Gi Adjustable Rods With Galvanised Butterfly Level Clips Of Size 85X 30X 0.8 Mm Spaced At 1200 Mm Center To Center Along Main T, Bottom Exposed Width Of 24 Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete For All Heights As Per Specifications, Drawings And As Directed By Engineer -In-Charge. Gi Metal Ceiling Lay In Perforated Tegular Global White Color Tiles Of Size 595X595 Mm And 0.5Mm Thick With 8 Mm Drop; Made Of Gi Sheet Having Glavanizing Of 100 Gms / Sqm ( Both Sides Inclusive ) And 20% Perforation Area With 1.8 Mm Dia Holes And Having Nrc ( Noise Reduction Coefficient ) Of 0.5, Electro Statically Polyster Powder Coated Of Thickness 60 Microns ( Minimum ) , Including Factory Painted After Bending And Perforation, And Backed With A Black Glass Fiber Acoustical Fleece. , Plumbing : Providing And Fixing White Vitreous China Extended Wall Mounting Water Closet Of Size 780X370x690 Mm Of Approved Shape Including Providing& Fixing White Vitreous China Cistern With Dual Flush Fitting, Of Flushing Capacity 3 Litre / 6 Litre ( Adjustable To 4 Litre / 8 Litres ) , Including Seat Cover, And Cistern Fittings, Nuts, Bolts And Gasket Etc Complete. , Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. , Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690Gms. 15 Mm Nominal Bore , Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require : White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps. , Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quality And Colour.600Mm Long Towel Rail With Total Length Of 645Mm, Width 78Mm And Effective Height Of 88Mm, Weighing Not Less Than190gms. , Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 20 Mm Pipe 10 Kgf / Cm2 , Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 75 Mm Pipe 6 Kgf / Cm2 , Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf / Cm2 , Constructing Soak Pit 1.20X1.20X1.20M Filled With Brickbats Including S.W. Drain Pipe 100 Mm Diameter And 1.20 M Long Complete As Per Standard Design. , Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. Flexible Pipe 32 Mm Dia , Providing And Fixing Pvc Door Frame Of Size 50X47mm With A Wall Thickness Of 5 Mm ( ± 0.2 Mm ) Made Out Of Single Piece Extruded Pvc Profile, With Mitred Cut Joints And Joint With 2Nos Of Pvc Bracket Of Size 190 Mm X 100 Mm Long Arms Of Cross Section Size 35 X 15Mm & Self Driven Self Taping Screws, The Vertical Door Profiles To Be Reinforced With 40X20mm M.S. Rectangular Tube Of 0.8 Mm , Including Providing Epdm Rubber Gasket Weather Seal Throughout The Frame, Including Jointing 5Mm Pvc Frame Strip With Pvc Solvent Cement On The Back Of The Profile. The Door Frame To Be Fixed To The Wall Using 8X100mm Long Anchor Fasteners Complete, All As Per Manufacturers Specification And Direction Of Engineer -In- Charge. , 35 Mm Thick Factory Made Solid Panel Pvc Door Shutter Made Out Of Single Piece Extruded Solid Pvc Profiles, 5 Mm ( ± 0.2Mm ) Thick, Having Styles &Rails ( Except Lock Rail ) Of Size 95 Mmx 35 Mm X 5 Mm, Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered ( On Both Side ) , Having One Side Thickness Of 15 Mm Integrally Extruded On The Hinge Side Of The Profile For Better Screw Holding Power, Including Reinforcing With Ms Tube Of Size 40 Mmx 20 Mm X 1 Mm, Joints Of Styles & Rails To Be Mitered Cut & Joint With The Help Of Pvc Solvent Cement, Self Driven Self Tapping Screws & M.S. Rectangular Pipes Bracket Of Size 190 Mm X 100 Mm Of Cross Section Size 35 Mm X 17 Mmx 1 Mm At Each Corner. Single Piece Extruded 5Mm Thick Solid Pvc Lock Rail Of Size 115 Mm X 35 Mm X 35 Mm, Out Of Which 95 Mm To Be Flat And 20 Mm To Be Tapered At Both Ends, Having 15 Mm Solid Core In Middle Of Rail Section Integrally Extruded, Fixing The Styles & Rails With The Help Of Solvent And Self Driven Self Tapping Screws Of 125 Mm X 11 Mm, Including Providing 5 Mm Single Piece Solid Pvc Extruded Sheet Inserted In The Door As Panel, All Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. Non Decorative Finish ( Matt Finish ) . , Providing And Fixing White Vitreous China Laboratory Sink With C.I Brackets, C.P. Brass Chain With Rubber Plug 40 Mm C.P Brass Waste And 40 Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required: Size 600X450x200 Mm , Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge.. , Miscellaneous : Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete. Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc , Steel Work In Built Up G I Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete , Providing And Fixing Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm ( +0.05% ) , Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X55mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Shelves, Shutter With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primerincluding All Fittings As Per The Direction Of Site Engineer-In-Charge. ( Total Area Of The Shutter Only Measured ) . , Providing And Fixing Thomson Multi Wood Board Or Equivalent Make, In Workstation For Treatment Planning Room, Workstation Cupboards, Shutter With Screws And Fittings Wherever Required, Edges To Be Painted With Polyurethane Primerincluding All Fittings As Per The Direction Of Site Engineer-In-Charge. , Supplying And Installation Of Medium Back Revolving Chairs For Workstation, Conference Hall And Training Room ( With Synchronized Tilt Mechanism, Zeropositiontiltlock, Pneumatic Height Adjustments, Abs Back Rest & Seat, Pu Arm Rest, Nylon Base With Castors ) ( Godrej, Wipro Or Bloster Make Or Equivalent ) , Supplying And Installation Of High Back Revolving Chair For Cabin ( With Synchronized Tilt Mechanism, Zero Position Tilt Lock, Pneumatic Height Adjustment, Dual Ply Backrest, Seat With Abs, Contoured Seat Mold, Chromed Adjustable Armrest, Chromed Base With Castors ) ( Godrej, Wipro Or Bloster Make Or Equivalent ) . , Supplying And Installation Of Visitors Chair, Pu Arm Rest, Non Revolving, Back And Seat With Abs, Countoured Seat Mould, ( Godrej, Wipro Or Bloster Make Or Equivalent ) , Attached Airport Type Stainless Steel Chair 4 Seated ( Combi Chair ) : Should Be Airport Model Combi Chair, Approximate Dimension Width 267 Inches, Height 303 Inches, Color : Silver, Seating Capacity : 4, Non Magnetic Ss High Quality Steel Perforated Seat Sheet And Back Rest, Rectangular Pipe 75Mm X 38Mm Cold Rolled, 7. Should Be 16 Guage Perforated Sheet, Aluminum Die-Casted Seat Edges, Should Be Provided With Metal Chrome Plated Armrest, Legs And Arm Rest Shall Be Cold Rolled Steel, Suitable For Heavy Public Use , Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below , Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area Beyond 3 Sq. Metres , Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Surplus Material And Stacking Of Serviceable Material With In 50 Meters Lead As Directed By Engineer-In-Charge. , Dismantling Old Electrical Points, Wiring, Lights And Handing Over The Same To The Hospital Authorities , Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar , Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead. For Thickness Of Tiles 10 Mm To 25 Mm , Dismantling Of Toilet Fittings Including Pipe Lines , Closets, Washbasin Etc To Complete , Providing Cable Trench For System Cables And Wherever Necessary With Metal Cover Including Finishing Works And All Allied Works , Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) , Providing And Fixing 2.0Mm Th. Vinyl Floor With Rubber Based Adhesive Over Clean And Smooth Surface Including Finishing By Rolling A Light Roller All Complete. , Providing And Fixing Sun Controlled Film On Glass Surface For Door / Windows, After Thoroughly Cleaning And Dust Free The Surface To Get Smooth Finish, To Get Air Tight Clean Surface, Ect, Complete As Directed By Engineer-In -Charge , Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. , Storage Cabinet For Accessories: Storage Cabinet For Accessories In 19 Mm Ply Board Construction Having Sides, Top, Front, Openable Panels Laminate Finish With Internal Horizontal Shelf 19Mm Commercial Plywood Painted ( Enamel ) As Per Approval. Front Panels To Have A Locking Arrangements With One Panel Having Tower Bolt On The Inner Sidewith Handles , Magnetic Hinges Andall Complete. , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width, Door With Glass Transparent Windows , Steel Cupboard ( Godrej ) For Storage 6Ft Tall 3 Feet Width, Ordinary Door , Computer Table ( Long ) With Keyboard Tray, Cpu Storage At Basein A Side And Storage Drawers At Other Side. ( For Workstation And Reports ) Reputed Brandgodrej / Featherlite / Wipro , Vaccum Cleaner Power Atleast : 1300Watts, Input 230Vac, Eureka Forbes Or Equivalent , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Pvc Name Plates - 24 ( L ) X 4 ( H ) Color And Matter Will Be Given By The Respective User Institute , Shoe Rack Three Shelves : Pretreated And Powder Coated, Three Shelves, Made Of Cold Rolled Ms Sheet Of 16 Guages, Six Cold Rolled Ms Tube Frame Levels As Support For 6 Pairs Of Shoes In One Shelf, Abrasion Resistant, Non-Discoloring, Corrosion Resistant , Fixing Window Curtain - Blinds Type With Fixtures , Fixing Window Curtain - Cloth With Fixtures , Fixing Door Curtain - Cloth With Fixtures , Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) , Using Good Quality Anjili Wood / Jack Wood , Providing And Fixing Paneling Or Paneling And Glazing In Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) Paneling For Paneled Or Paneled And Glazed Shutters 25 Mm To 40 Mm Thick Using Good Quality Anjili / Jack Wood , Providing And Fixing 4 Mm Thick Coir Veneer Board, Isi Marked Is : 14842, Plain Lining With Necessary Screws, Priming Coat On Unexposed Surface Etc., Complete , Providing And Fixing 35 Mm Thick Factory Made Laminated Veneer Lumber Door Shutter Conforming To Is: 14616 And Tads 15:2001 ( Part B ) , Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessery Screws, All Complete As Per Directions Of Engineer-In-Charge And Panelling With Panels Of: 12 Mm Thick Pre- Laminated Particle Board ( Decorative Lamination On Both Sides ) Grade -1, Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I, Conforming To Is : 3087, Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Prelaminated Conforming To Is : 12823, Grade I, Type - Ii Marked : , Rodent Bait Station , 42 Led Television , Site Cleaning , Water Heater Cooler Dispensor With Purifier , Patient Address System For The Reception And Patient Waiting Area , Channel Music System In The Treatment Room And Control Room , File Cabinet ( 4 Cabinet Type Godrej / Equivalent ) , Supply, Installation, Testing & Commissioning Oflt Panel , Cubicle Type, Made Out Of 2Mm Thick Crca Sheet, Totally Enclosed, Ip 42, Free Standing, Floor Mounting, Dust And Vermin Proof, Indoor, Compartmentalised, Suitable For Operation On 3 Phase , 415 V, 50Hz Ac System With Busbars , Including Internal Wiring With Suitable Sizehffr Wires / Cable, Interconnection, Duly Powder Coated With Seven Tank Process Etc., Including All Inter Connections And Following Components As Per Drawing And Technical Specifications. Incomer Suitable Capacity For Air Conditioners And Equipment, Mccb With Adjustable Thermal Magnetic Release With Ol & Sc Protection - 1 Nos. Busbars Suitable Capacity Tpn Busbars Of Aluminum Alloy High Conductivity With Heat Shrinkable Coloured Sleeves Instruments Digital Type Multifunction Meter With Cts Of Suitable Rating For Measurement Of Voltage, Current, Frequency, Power Factor, Kva, Kw, Kwh. - 1 No On / Off Indication Lamps-1Set Ryb Indicating Lamps Led Type - 3 Nos. Outgoingssuitable Capacity Mccb With Adjustable Thermal Magnetic Release With Ol & Sc Protection For Machine - 1 Nos. 100A / 63A / 40A / 25A Fp / Tp Mccb With Thermal Magnetic Release With Ol & Sc Protection -4 - 6 Nos For Lighting, Power, Ac Units. , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) Tpn, Mcb Db, 4 Way ( 8+12 ) , Double Door, Horizontal Type , Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required. ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 6 Way ( 4+18 ) , Tpn, Vertical Type, Mcb Db, Double Door , Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole 6 A. To 32 A. RatingsB / C Curve , Supplying And Fixing Following Rating 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A Tp Mcb, C-Curve Mcb , Supplying And Fixing Following Rating 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Tp Mcb, C-Curve Mcb , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps , Supplying And Fixing Following Rating, Four Pole, ( Three Phase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 Amps Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 3 Pin 5 / 6 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 15 / 16 Amp Switch , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 Amp Socket Outlet , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20A Dp Switch , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 1.5 Sq. Mm + 2 X 1.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 2.5 Sq. Mm + 2 X 2.5 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire , Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire , Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In Existing / Recessed Steel / Pvc Conduit As Required. 1 Run Of Cable , Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In Existing / Recessed Steel / Pvc Conduit As Required. 2 Run Of Cable , Supplying And Drawing Following Pair 0.5 Sq Mm Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair Cable , Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. Group C , Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group B , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Telephone Socket Outlet Rj 11 , Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. Cat 6 Rj 45Computer Jack , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 3 Module ( 100Mmx75mm ) , Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required. 8 Module ( Single Row ) , Supplying And Fixing Of Wall / Ceiling Mounted Type Ip 65 Circular Led Fitting, 18 W Along With Led Lamp , Supplying And Fixing Of Wall / Ceiling Mounted Type Ip 65 Led Fitting, 36W 2 Ft X 2Ft Along With Led Lamp , Supplying And Fixing Of 6 / 7 W Bayonet Cap Type Led Bulb In The Existing Angle Batton Etc As Required ( Philips, Wipro Or Similar Superior Make ) , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Un-Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 70 Sq.Mm In Following Ways Including All Necessary Accessories As Required. The Existing Masonry Open Duct , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 70 Sq.Mm In Following Ways Including All Necessary Accessories As Required. On Wall Surface ( ( Clamped With 1Mm Thick Saddle ) ) , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Un-Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 50 Sq.Mm In Following Ways Including All Necessary Accessories As Required. The Existing Masonry Open Duct , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 50 Sq.Mm In Following Ways Including All Necessary Accessories As Required. On Wall Surface ( ( Clamped With 1Mm Thick Saddle ) ) , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Un-Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 25 Sq.Mm In Following Ways Including All Necessary Accessories As Required. The Existing Masonry Open Duct , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 25 Sq.Mm In Following Ways Including All Necessary Accessories As Required. On Wall Surface ( ( Clamped With 1Mm Thick Saddle ) ) , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Un-Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 16 Sq.Mm In Following Ways Including All Necessary Accessories As Required. The Existing Masonry Open Duct , Supplying, Laying And Fixing Of One Numberpvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade Of 4C X 16 Sq.Mm In Following Ways Including All Necessary Accessories As Required. On Wall Surface ( ( Clamped With 1Mm Thick Saddle ) ) , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 70 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 50 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 25 Sq.Mm , Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe 2, Armoured, Copper Power Cable Of 1.1Kv Grade As Required. 4C X 16 Sq.Mm , Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , Providing And Fixing Earth Bus Of 25 Mm X 3 Mm Copper Strip On Surface For Connections Etc. As Required. Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) , Supply And Laying Of 1C 35 Sqmm Cu Cable For Earthing Conductor , Supply And Laying Of 1C 25 Sqmm Cu Cable For Earthing Conductor , Supply And Laying Of 1C 16 Sqmm Cu Cable For Earthing Conductor , Supplying , Installation, Testing And Commissioning Of 1200 Mm Ceiling Fans With Bee 5 Star Rating For Energy Efficiency, Including Wiring The Down Rods Of Standard Length ( Upto 30Cm ) With 1.5Sq Mm Fr Pvc Insulated, Copper Conductor Single Core Cable Etc As Required. , Supplying And Fixing 2 Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supply, Installation, Testing And Comissioning Of Residential Type Light Duty Exhaust Fan 900-1350 Rpm, 250 Mm, In Plastic Housing Light Dutyin The Existing Opening, Including Louver Shutter, Making The Hole To Suit The Size Of The Above Fan, Making Good The Damage, Connection, Testing Commissioning Etc As Required , 24-Port Gigabit Manageable Smart Network Switch With 2 Sfps. Rack Mountable , Patch Panel - 24-Port Patch Panel With Cable Tray. Rack Mountable , 4U Rack- Wall Mountable Including 4X 6Amp Power Distribution Box , Supply Of Branded 1Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 2Mtr Patch Cords With Cat 6 Cable. , Supply Of Branded 3Mtr Patch Cords With Cat 6 Cable. , Ductable A / C Units8.5 Tr X 2 Nos ( 2 Outdoor Unit Of8.5Tr And 2 Ahu ) Low Side Works For Complete Installation & Commissioning Of Ac Supply , Installation , Testing & Commissioning Of 8.5 Tr Or Higher Capacity Aircooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fitting, Gss Sheet Metal Duct ( Insulation Using Resin Bounded Glass Wool With 7 Micron Aluminium Foil ) For Air Distribution 22 / 24 G, Idu Ss Drain Pan As Per Specification Complete With Suitable Capacity Drive Motor , Aircooled Condensor With All Accessories, Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Support For Fixing Idu / Odu, Safety Devices Including Thermal Protector, Pressure Releafe Valve , Overload Relay Single Phase Preventer Etc, Power Wiring And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out Suitable For 3 Phase 440V Supply Etc Complete As Required. The Two Units Shall Work Alternatively. Should Have Provision To Change Automatically In Prefixed Time. Should Also Have Provision To Control Both Unit Manually. Quoted Rate Shall Be Inclusive Of Two Nos 8.5Tr Outdoor And Indoor Unit With Ducting Works , Heater Coils For Humidity Control, Air Diffusers / Supplpy Air Louvers With Vcd, Motorized Vcd, Thermal Insulation Using Nitrile Rubber For Duct, Acoustic Insulation For Duct, Gas Charging, Copper And Drain Pipes With Thermal Insulation, Outdoor Unit Stands, Connection Canvas, Scaffolding Works For Erection, Installation Testing And Commissioning Charges And All Other Accesories. , Suitable De- Humidifier Units : Extraction At Least 35 Litres / Day, Compresor : Rotary, Air Flow : At Least 220M3 / Hr, Reputed Brand, Input 230Vac , Charges For Obtaining Electrical Inspectorates Approval ( Sanction For Energisation ) And Regularizing With Kseb , Underdeck Insulation With 13 Mm Nitrile Rubber For The Entire Airconditoned Space Of Ductable Ac. , Supply And Installation Of Portable Fire Extingwisher ( 4 Kg ) With Wall Mounted For Fire Type Abc Classification , Supply Installation Testing And Commissioning Of 2 Tonne Inverter Split Air Conditioner With Copper Condensor / Evaporator Coil 5 Star Or Above With Stabilizer Complete Installation And Commissioning ( Rate For 1 No ) With Copper Pipes And Drain Pipes, Outdoor Unit Stands, Gas Charging Etc. , Ductable A / C Units5.5 Tr X 2 Nos ( 2 Outdoor Unit Of5.5Tr And 2 Ahu ) Low Side Works For Complete Installation & Commissioning Of Ac Supply , Installation , Testing & Commissioning Of 5.5 Tr Or Higher Capacity Aircooled Ductable Split Air Conditioner With Ceiling Suspended Idu And All Standard Fitting, Gss Sheet Metal Duct ( Insulation Using Resin Bounded Glass Wool With 7 Micron Aluminium Foil ) For Air Distribution 22 / 24 G, Idu Ss Drain Pan As Per Specification Complete With Suitable Capacity Drive Motor , Aircooled Condensor With All Accessories , Hermetically Sealed Scroll Compressor, Electronic Microprocessor Pendant Controller With Digital Display, First Charge Refrigerant Gas, Vibration Isolator Pads, Structural Support For Fixing Idu / Odu, Safety Devices Including Thermal Protector, Pressur Releafe Valve , Overload Relay Single Phase Preventer Etc, Power Wiring And Control Cabling ( Indoor To Outdoor ) , Thermostat Wiring, High-Low Pressure Cut Out Suitable For 3 Phase 440V Supply Etc Complete As Required. The Two Units Shall Work Alternatively. Should Have Provision To Change Automatically In Prefixed Time. Should Also Have Provision To Control Both Unit Manually. Quoted Rate Shall Be Inclusive Of Two Nos 8.5Tr Outdoor And Indoor Unit With Ducting Works , Heater Coils For Humidity Control, Air Diffusers / Supplpy Air Louvers With Vcd, Motorized Vcd, Thermal Insulation Using Nitrile Rubber For Duct, Acoustic Insulation For Duct, Gas Charging, Copper And Drain Pipes With Thermal Insulation, Outdoor Unit Stands, Connection Canvas, Scaffolding Works For Erection, Installation Testing And Commissioning Charges And All Other Accesories.