}

Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Divisional Store Rrcr Premises At Dr.Ali Jan Road. Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Division, Zoonimar-Jammu And Kashmir

Public Works Department has published Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Divisional Store Rrcr Premises At Dr.Ali Jan Road. Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Division. Submission Date for this Tender is 27-12-2021. Hand Glove Tenders in Zoonimar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30357130
Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Divisional Store Rrcr Premises At Dr.Ali Jan Road. Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Division
Open Tender
Indian
Jammu And Kashmir
Zoonimar
27-12-2021

Tender Details

Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Divisional Store Rrcr Premises At Dr.Ali Jan Road. Supply Of Lab Equipment For Quality Control / Material Testing At Material Testing Laboratory In Divisional Store Rrcr Premises At Dr.Ali Jan Road. , Is Sieve Sets ( 20Cm Dia Brass Frame ) Sizes ( Mm / Micron ) ( A ) 10.00Mm, ( B ) 4.75Mm © 2.36Mm ( D ) 2.00Mm ( E ) 1.18Mm ( F ) 1.00Mm ( G ) 600 ? ( H ) 425? ( I ) 300? ( J ) 150? ( K ) 90? ( L ) 75?.Pan & Cover , Is Soeve Sets ( As Per Specifications Of Is:460 ) Iss -Gi Frame Sieve Set ( Size 30Cm Dia ) A ) 125Mm B ) 106Mm C ) 90Mm, D ) 80Mm E ) 63Mm F ) 53Mm G ) 45Mm H ) 40Mm I ) 37.5Mm J ) 31.0Mmk ) 26.5Mm L ) 22.40Mm M ) 20Mm N ) 19Mm O ) 16Mm P ) 32.2Mm Q ) 12.5Mm R ) 11.2Mm S ) 10.0Mm T ) 9.5Mm U ) 8.3Mm V ) 5.6Mm W ) 2.8Mm X ) 4.75Mm Y ) 3.35Mm Z ) 2.36Mm , Standard Laboratory Use Coarse Grade Sand :Coarse Sand Must Be Supplied As Per Is 650 In 25 Kg Bags And It Must Be Clean And Free From Any Organic / Inorganicimourities Or Excess Silt , Standard Laboratory Use Medium Grade Sand :Mediumsand Must Be Supplied As Per Is 650 In 25 Kg Bags And It Must Be Clean And Free From Any Organic / Inorganicimourities Or Excess Silt , Standard Laboratory Use Finegrade Sand :Mediumsand Must Be Supplied As Per Is 650 In 25 Kg Bags And It Must Be Clean And Free From Any Organic / Inorganicimourities Or Excess Silt , Fresh Concrete Mixer ( Pan Type 40 Ltr Capacity:Equipment Must Be Transportable On Self Wheels . It Must Be Supplied With Minmium Mixing Drum Capacity Of 40 Liters Of Fresh Concrete . The Drum Rpm At Least 20 To 25 Rpm Is Desirabale Mix Must Have Provision Of Adjustable Blades Besides Suitable For Mixing Mineral Aggregate . Equipment Must Run By 415 V ( *5% ) 50Hz. Three Phase Ac Supply Or Single Phase Supply Of 220 V ( 15% ) 50Hz ( Equipment Must Be Superior Make Manufacture And Finish Complete In All Respect , Laboratory Concrete Specimen Cube Moulds: As Per Relevant Is Specifications ( Is 10086 ) : Cube Moulds For Preparing Concrete Specifens For Checking Compressive Strength Of Cement Concvrte Of Size 150Mm , Motorised Sieve Shaker : Equipment Must Consists Of Motorized Seive Shaker For Saving Of Ganular Or Bpwdered Material / Soils. It Must Accommodate Up K 8 Sieves Of 20 Cm Dia. The Equipment Must Be Geated Metro Driver Of Suitable Hp. Directionsof Inclination Of Sieve Table Must Change Progressively In Clock Wise Directions With Both Gravtory And Tapping Motion Of Table . Equipment Must Be Controlled By A Proper Switching Device With Time Facility And Emergency Stop / Start Button . Equipment Must Run By 220 V ( 15% ) 50Hz Single Phase Ac Supply . Equipment Must Be Good Make / Manufacture With Finish Complete And Operatonal In All Respects , Waterbath ( Reputted Make ) Water Bath Thermostaticously Controlled Or With Digital Controller Cum Indicator Doubied Wailedinner Chamber Made Of Non Rustingsatinless Steel Outer Body Made Of Ss End Minimum Dimension 425X325x100 ) Mm Or Better With Temperature Range Of 5C -100C With Precision Of 10.5C Run By 220 V ( *5% ) 50Hz Single Pahse Ac Supply. Equipment Must Be Good Make / Manufacture With Finish Complete And Operatonal In All Respects , Electric Hot Air Oven ( Reputed Make ) : -0 Superior Laboratory Electriceven Thermostatically Controlled Or With Digital Controller Cum Indicator With Safaety Alarm . It Must Be Double Walled With Outer Body Made Of Ms Powder Coated & Inner Madeof Stainless Steel , It Must Haveprovisionfor Horizontal Ribs For Adjusting Trays And Any Height . Equipment Must Have Side Heating / Ait Circulating Fan To Distribute The Temperaturre Range 50 Degree Centrigrade To 25 Degree Centrigradewith Air Ventilator . The Size Of Oven Must Be 450X450x450 Cm With Size Tolerance + 10Mm Equipment Must Operate Under 220 V ( 15% ) 50Hz Single Phase Ac Supply, Equipment Must Be Good Make / Manufacture With Finish Complete And Operatonal In All Respects , Precision Electronic / Digital Balance With Dual Power Operation ( Ac / Battery ) 400Gm - 600Gm Capacity With Read Out Of At Least 0.01Gm Reproductibility Of 0.01Gm ( Complete & Operational In All Respects , Precision Electronic / Digital Balance With Dual Power Operation ( Ac / Battery ) Superior Brand Precision Digital Balance 5 Kg Capbale Of Measuring Atleast 1Gm To 5 Kg With Permissible Error , Precision Electronic / Digital Balance With Dual Power Operation ( Ac / Battery ) Superior Brand Precision Digital Balance 5 Kg Capbale Of Measuring Atleast 5Gm To 30 Kg With Permissible Error ( Complete And Operational In Allrespects ) , Precision Infared Therometer : Digital Non Contact Infared Therometer ( Fluke Or Superior Make ) With Back Light Lcd Display Battery Powered With Minimum Operational Temperature Range Of -20 Degree To 300 Degree For Better Display Resolution Of Atleast 0.1 Degree Per F Suitable Spectular Responsive Class 2- Lazer Power With Display Hold Feature. ( Complete And Operational In Allrespects ) , Precision Probetherometer : Digitalcontact Type Probe Therometerwith Minimum Opertaional Temperature Range 24 Degree To 300 Degree Or Better Display Resolution Of Atleast 0.1 Degree F. ( Complete And Operational In Allrespects ) , Aggregate Impact Testing Machine . ( As Per Speecfication Of Is 9377 ) Standard Aggregate Impact Testing Machine For Determination Of Impact Value For Small Size Mineral Aggregates / Stocks ( Equipment Must Be Superior Make Manufacture And Finish Complete In All Respect , Enamel Ei-Trays: Sam Purpose Enamel Tray / Plates / Bucket Of Following Mimimum Sizescomplete & Opertaional In All Respects250mm X300m Tray , 450Mm X 600Mm - Tray , Flakeness Apparatus ( Shape Test ) : As Per Specification Sp-36 Is 2386 Part-I ( Equipment Must Consists Of Following Thickness Guage Manufactured From Heavy Gauge Steel With Is Certifcation Stamp ( Equpment Must Be Of Good Make And Manufacture And Finish Complete & Operational In All Respects , Elongationapparatus ( Shape Test ) : As Per Specification Sp-36 Is 2386 Part-I ( Equipment Must Consists Of Following Thickness Guage Manufactured From Heavy Gauge Steel With Is Certifcation Stamp ( Equpment Must Be Of Good Make And Manufacture And Finish Complete & Operational In All Respects , Standardvicat Apparatus ( Cement Testing ) : Equipment Must Be Provided For Determinationof Consistency Of Standard Cement Paste And Must Initial Final Setting Times Of Cement . Equipment Must Be In Conformation With Is : 5513 - 1976 With Following Minmium Specifications; 1 ) A Stable Frame With Vertically Moveable Rod To Accomodate Consistency Plunger And Setting Time Needles And Having A Cap At The Top. 2 ) Vicat Mould In The Form Of Frustum Of A Cone With Internal Diameter Of 60Mm At Top 70Mm At The Bottom And A Height Of 40Mm . 3 ) Spilt Type Vicat Mould With Clamping Ring . 4 ) Ms Base Plate & Class Base - Plate For The Mould . 5 ) Intial Setting The Needle. 6 ) Final Setting Time Needle 7 ) Standard Consistency Plunger ( Equipment / Supply Must Be Of Superior Make And Manufacture And Finishcomplete In All Respects , Le - Chatelier Soundness Test Appratus ( Cement ) : Le- Chateclier Moulds With Is Certification Must Be Suplied For Determination Of Countness Of Cement And Class A And Class B Time . The Appratus Must Be Confirmation With Is 5514, Is 1727 Is: 2645, Is 4031, Is 6932 ( Part - 9 ) With Following Minimum Specifications.1 ) Orit Spilt Cylinder Mould 30 Mm Dia X30mm High Made Ofspring Brass With Two Indicators Arms Strongly Soldered On Either Sides Of Spilt . 2 ) Two Glass Plates3 ) One Load Weight Approximately 100Gms. ( Equipment / Supply Must Be Of Superior Make .Manufacture And Finish , Complete In All Respects ) , Le-Chatelier Water Bath With Controller:Equipment Must Be Compatible Withrequirements Of Ls , Soundless. Test With Following Minimum Specvifications: 1 ) Water Bath Must Be Doubel Walled Made From Heavy Gauge Steelness Steel Sheets For Maintaining Of Tempature Ofwaterof 27 ± 2°C With Proper Insulation Provided Between The Walls. 2 ) . Provided With An Immersion Type Heater, With Thermostate Regulator For Controlling The Temperature. 3 ) . Provided With Arrangements For Having A Removable Rack To Hold Multiple Le Chatliers Moulds. 4 ) . Operational At 220V ± 10V Single Phalse 50Hz Ac ( Supply Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect ) , Slump Test Appratus: As Per Is Specifications Is 7320 ) Apparatus Must Be Complete For Determination Of Slum Of Fresh Concrete For Measuring Its Consitency For Agregate Size Less Than 38Mm. Appratus Must Include Standard Size Slump Cone, Base Plates & Tamping Road > ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Cement Mortar Mixer: Equipment Must Be Provided For Prepation Of Plastic Mortar Of Cement And Pozzalanic Material For Making Types Of Test Specimens In The Laboratory : Equipent Must Be In Confirmation With Is : 10890 - 1984 , Is 1727- 1967, Is 4031 And Must Comprise Of Following Specifications: 1 ) A Stainless Steel Mixing Bowl Of About 6 Litre Capacity , Which Can Be Held With The Mixing Appratus And Its Height Adjustable . 2 ) Stainless Steel Mixing Paddles Of Standard / Specified Shape And Dimension Which Can Be Attached Or Removed Easily . 3 ) A Power / Motor Driven Mixer Which Simultanously Impart Two Motions To Mixing Paddlei.E Revolving And Planetary . They Being Opposite To One Another In Directions. 4 ) A Two Speed Gear Box ( Low / High ) To Revovle Paddle At Approximately 140 Rpm ± 5Rpm, And 285 ± 10 Rpm , With Corresponding Planetary Motion Of 62±5Rpm And 125 ±10Rpm Respectively 5 ) All Accessories Like Scrapper, Cleaning Brush Etc . ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Bitumen Binder Centrifuge Extractor ) As Per Relevant Is Specifications Astm D 2172: Manually Operated Bitumenbinder Centrifuge Extractor For Bitumenious Mix Up To 1.5 Kg Capacity With Hand Speed Control With Filter Paper Discs ( Set Of500sheets ) . Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects. , Softening Point Apparatus ( Ring & Ball Method ) The Test Apparatus Must Be As Per Is 1205 / Astmd36 Relevant Specifications For Determination Of Softening Temperature Of Bitumenusing Ring And Ball Method. Equipment Must Have Built In Heating Facility , Magenitc Stirrer And Temperature Controller . Apparatus Must Be Operational For 220V , 50Hz Single Phase Ac Supply, ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Ductility Apparatus ( Electrically Operated With Cooling Arrangements ) : The Test Apparatus Must Be As Per Is: 1208 / Astmd113 Relevant Specifications For Determination Of Ductility Of Bitumen Using Control Elongation ( Constant Speed ) By Way Of Ductility Machine. Equipment Must Have Build In Water Bath With Heating Facility Using Electric Pump Circulator Andheater . ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Consistency Test Apparatus: The Test Apparatus Must Be As Per Is 2720 Part 5 Is 9259 Relevant Spectifiactions For Determination Of Consitstency ( Liquid Limt ) Of Soils By Casagrande Method. The Appratus Must Be Operational With Counter , With Is / Bs / Astm Grooving Tools, Gauging Block. ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Sand Replacement Field Density Apparatus: ( Small ) The Test Apparatus Must Be As Per Is 2720 ( Part 28 ) With Following Parts :- 1 ) Sand Pouring Cylinder Fitted With Conical Funnel And Shutter, Capacity 3 Ltr. ( 1 No ) . 2 ) . Cylindrical Caliberations Container 100 Mm Id X 150Mm Height ( 1 No. ) . 3 ) , Metal Tray Size 30X30x4 Cm With 10Cm Central Hole ( 1 No. ) ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Los Angeles Abrasion Testingmachine With Abrasive Charge: Is Standard Is 10070, To Determine The Resistance To Wear Off Small Size Coarseaggregate And Crushed Rocks Detachable Shelf, Drum Rotation Of 30-33 Rpm With Electric Motor And Heavy Duty Reduction Gear. Supplied With Tray For Collection Of Material , Operational Sutibality 415V , 3 Phase , 50Hz , Ac Supply . Abrasive Charge Set Of12 Hardened 48Mm Dia Ditgital Controller Box. ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Universal Penetrometer With Penetration Cone And Bitumen Penetrationkit Is 1448 Part 60 Astm:D937, Ip: 179 , Bs : 4698 Astm : D 217 , Ip : 50 Iso : 2137 , En: 1426 , 13179 - 2Equipment Must Of Following Replicable Parts. A ) Universal Penetrometer With Adjustable Head And Display ( 01 No ) . B ) Penetration Cone For Deterimnation Of Consistency Of Lubricating Grease Andoils ( 1 No ) C ) . Bitument Penetration Kit Constisting Of Penetration Needle, Copper Transfer Dish, Aluminum Containers ( 1 No ) . D ) . Penetration Test Cone For Soils With Cups ( 1 No. ) ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Cleveland Flash ( Open ) & Fire Point Apparatus. ( As Per Specifications Of Is 1448, P:69, Is : 73-2013 ) . Equipments Must Be Capable For Determiningflash& Fire Point Bitumen. The Flash Cup Must Be Made Of Brass With Insulated Handle. Equiment Must Have Metal Heating Plate Electrically Operated With Energy Regulator And Gas Jet Assembly . Complete In Allrespects With All Optional Accessories , Absolute ( Dynamic ) & Kinematic Viscosity Apparatus. As Per Is Specification 1206 Part - Ii & Part-Iii, Is : 73-2013. Equipment Must Comprise Of Following : A ) 2 No. Imported Viscometer Tubes ( Cannon - Manning Vaccume Viscometer ) Made Ofborosilcate Glass With Size No. 12 ( Is: 1206 Part -Ii ) For Determination Of Absulte Viscocity In The Range Of 300 - 8000 Poise At 60 °C Along With Calibration Certificate . B ) 2 No Imported Viscometer Tubes ( Cannon -Fenske Viscometer ) Made Of Borosilicate Glass With Size No. 350 ( Is : 1206 Part -Ii ) For Deterimnation Ofkinematic Viscoscity In The Range Of 30-500 Cst At 135 °Calong With Calibaration Certificate. C ) 01 No. Oil Free Vaccum Application Systemwith 4 Lines With Vacum Rangeupto 300Mmof Hgand Least Measurable And Maintainable Level Of ± 0.5Mm Of Hg. D ) , 3 No. Mercury In Glass Tube Type Thermometre With Range Of 0°C To 150°C, Scale ± 0.2°C, ( As Per Is : 1206-Part-Ii ) . E ) , 1 No. Viscometre Sillicon Bath , With Uniform Temperature Maintainance System, Using Accurate Pdi Temperature Controller With Accuracy Of± 1°C, For Conduction Of Absolute And Kinematic Viscosity Teston Bitumenous And Cut Bag Materials By Vaccum Capillary Method At Specified Temperatures ( Complete And Operational In All Respects With Optional Accessories ) . , Pavement Depth / Thickness Guage. Ms Thickness Gauge With Minimum Gauging Depth 150Mm ( Complete & Operational In All Respects ) , Soil Hydrometer.: As Per Is Specifications / Sp-36, Is: 2720 ( Part -4 ) , Is:3014 ( For Soils / Fines With > 10% Passing 75Micron Sieve ) . Soil Hydrometre Made Of Superior Clear / Transperant Glass Of Uniform Clarity Throughout The Upper Density Scale Range Must Be 0.995 To 1.30 G / Cc ( G / Ml ) At 27°C With Least Count Of 0.0005 G / Cc ( G / Ml ) . There Shall Be No Abrupt Changes In The X Section Of The Hydrometre, Such As Will Hinder Cleaning Or Permit Air Bubbles To Be Trapped. The Hydrometre Shall Have Maximum Permissible Scale Error Of Plus / Minus One Scale Division. ( Complete And Operational In All Respects ) . , Soil Pycnometer ( As Per Reference Standard Is:2386 For Deterimination Of Specific Gravity Of Clays , Sands And Gravals Of Grain Soil Less Than 10Mm ) . Equipments Must Consist Of 1 Kg / 1 Ltr. Superior Glass Bottles, With Bored Brass Cone Stopper, With Locking Ring And Rubble Seal. ( Complete And Operational In All Respects ) . , Density Bottle As Per Reference Standard Is: 2720 Part - 1. It Must Consist Of Folowing Capacitysuperior Lab, Glass Bottles With Cappillary Vent, Leak Proof Stopper. 25Ml , 50Ml , 100 Ml , Table Mounted Marshalls Stabilty Apparatus: ( As Per Is / Astm D-1559, D-6927 Specifications ) . Equipment Must Consist Of Marshalls Stability Loading Frame 50 Kn Capacity ( With Proving Ring ) , Single Speed With Platen Speed 50.8 Mm Per Minute ( Precise Speed ) Suitable To Operate On 220V , 50Hz Single Phase Ac Supply, Limit Switch Protection For Both Upward And Downward Travel. Following Must Be Supplied With The Apparatus.A ) Marshalls Steel Compaction Hammer , Weight 4.5 Kg With A Free Fall Of 457 Mm ( 02 No. ) B ) Compaction Moulds ( 10.16Cm Dia And 7.6Cm Height, For 25.4Mm Maximum Nominal Aggregate Size ) Of Steel Cylindrical, With Individual Extension Collar And Base Plates ( 6 No.S ) C ) , Hydraulic Sample Eject ( 01 No. ) D ) Sample Breaking Head With Load Transfer Bar And Flow Measurement Arrangment Using Dial Gauge. E ) , Compaction Pedestal Comprising Of Steel Plate Capped Wooden Post. ( Equipment Must Be Of Good Make / Manufacture And Finish. Complete And Operational In All Respects ) , Hydraulic Loading Apparatus For Load Tests ( 2000 Kn ) : For Conduction Of Pile Load Test As Per Is Specifications Sp-36, Is:1888, Is: 3014. Equiment Must Include Hydraulic Jack 2000 Kn ( 200 Mt ) Capacity, Alongwith Calibrated 2000 Kn ( 200 Mt ) , 1000Kn ( 100Mt ) & 500Kn ( 50Mt ) Capacity Pressure Gauge With Suitable Least Count. Equipment Must Include Heavy Duty Hand Operated Remote Hydraulic Oil Pumping Unit, High Pressure Flexible Pipe ( At Least 5M ) . The Hydraulicjack Must Be Provided With A Piston Travel / Strock Of Atleast 150Mm Or Higher. The Supply Shall Include 4 No. Magnetic Bases With Adjustable Long Extensions For Holding Dial Gauges For Measurement Of Displacement. Superiormechanical Deflection Dial Gauges ( 4 No. ) Of 0.01 - 50Mm Working Range. ( Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Analog Electrically Operated Ctm : 1000Kn Compression Testing Machine Conforming To Is:14858 With ± 1% Accuracy. Loading Range 1000 Kn ( 100T ) With Lc 5 Kn Maximum Clearance Between Platens:390Mm . Maximum Clearance Between Side Platens:260Mm. Platen Size : 222Mm Dia . Platen Hardness :612Hv ( 55 Hrc ) . Piston Dia : 157Mm , Piston Stroke :50Mm. Motor Hp :1 Hp, Motor Make: Standard / Approved Make. Power Requirements : 220 V / 230V, 1 Phase, 50 Hz, Ac Supply, Specimen Size : 100Mm , 150Mm Cube , 100Mm And 150Mm Dia Cylinder. Standards : Is : 516 And Is:14858. Pumping Unit To Be Electrically Operated. Unique Features Are : A ) . Caliberation Within 1% Of Full Scale Deflection With Traceablity To Nabl. B ) . Powder Coating Finishing Surface. C ) . Front Gate For Protection. D ) . Pump With Brass Casing.The Complete Unit Comprises Of :- A ) . Loading Unit : Is Of Fully Welded Construction Having A Cross Head With A Spherical Seated Platen. The Lower Platen Is Attached To The Top Of Piston. Cubes Upto 300Mm And Cylinders Upto 300Mm Dia X 300 Mm Height Can Be Tested Using Appropriate Models. B ) . Continous Voltage Transformer ( Cvt ) With Nabl Calibrations.Equipment / Supply Must Be Of Superior Make / Maunufacture And Finish Complete In All Respects ) . , Califomia Bearing Ratio Apparatus ( As Per Spectifications Of Is:9669, Is : 2720-Xvi, Etc ) Specification Of Cbr Moulds. The Materials For Construction Of The Various Equipment Shall Be As Given In Above Standard. Mould:The Mould Dia Shall Be 150Mm Collar: The Collar Shall Be Made From Same Material As That Of Mould. Two Similar Ears As In The Case Of The Mould Shall Be Cast Integral With The Body Or Welded Base Plate: A Suitable Seating About 2Mm Deep Shall Be Provided On The Top Face For Proper Seating Of The Mould Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect , Soil Compaction Apparatus As Per Specification / Ref. Standard Of Is: 10074 ( Part Vii ) , Is: 2720 ( Part-Vii ) , Is:9198. Equipment Must Consist Of Following For Performing Tests To Determine Density Moisture Relations For Soils A ) .Standard Compaction Apparatus ( Light Compaction / Standard Proctor ) Consisting Of 1000 Ml Volume Gun Metal Mould, 100Mm Dia ( Id ) , 127.3Mm Height. B ) . Base Plate & Collar C ) . Hammer Of 2.6 Kgs With 310 Mm Fall. Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect , Soil Compaction Apparatus ( Modified ) ( As Per Is:2720 ( Part 8 ) , Is: 9198 Is:10074 Modified Compaction Mould In Mild Steel ( Heavy Compaction / Modified Proctor ) Consisting Of 2250 Ml Volume Mould, 150Mm Diameter And 127.3 Mm Height. Rammer / Hammer Weight 4.90 Kg With Controlled Free Vertical Fall Of 450Mm With 50Mm Dia Meter Of Compaction Face / End With Base Plate And Colour Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect , Dynamic Cone Penetrometer For In Place Cbr. ( As Per Astm D6951 ) Dynamiccone Penetrometer ( Dcp ) Is Used For Rapid In Situ Measuement Of The Structural Properties Of Existing Road Pavement Constructed With Unbound Materials. The Unit Incorporates An 8 Kg Weight With A Drop Of 575 Mm And A 20Mm Diameter Cone Fitted To The End Of The Shaft, Allowing Measurements To Be Made Down To A Depth Of Approaximately 850 Mm. 8 Kg Weight Dropping Mass Trough A Height Of 575 Mm. Anvil With Driving Rod. Penetration Rod With 60 °, 20 Mm Dia Cone.Spanners, Tommy Bar, Bottle Of Adhesive. All Contained In A Carrying Case. Case Dimensions ( 1200X350x200 Mm Approx. ) Weight Approx 30 Kg , Cement Mortar Cube Moulds Cube Mould Of 70.6 Mm Size Conforming To Is: 10086-1982 Supply Must Be Of Superior Made / Manufaccture And Finish, Complete In All Respect , Compaction Factor Apparatus ( As Per Is:5515 ) The Apparatus Shall Consist Of Two Conical Hoppers Mounted Above A Cylindrical Receiver. The Hoopers Shall Be Of Rigid Constructions True To Shape And Finsihed Smooth Inside. They Shall Be Made Of Cast Brass Conforming To Is:292-1961, Or Cast Iron Of Grade 20 Conforming To Is: 210-1975. Brass Sheet Atleast 3Mm Thick ( Reciever - The Cylindrical Reciever Shall Be Of Rigid Construction, True To Shape And Finished Smooth Inside. It Shall Be Made Of Cast Brass Or Cast Iron. The Top Edge Shall Be Accurately Machined Normal To The Cylinder Axis. Frame- The Fram Shall Be Of Rigid Construction. Welded Or Riveted Rolled Structural Sections Would Be Suitable. Accessories:- The Apparatus Shall Also Include Two Ordinary Trowels Having A Steel Blade Of 200 Mm In Length With Straight Edge, A Hand Scoop About 150Mm Long , A 16Mm Diametre And 600Mm Long Steel Tamping Bar With A Rounded Working End And Scales ( Or A Balance ) To Weight Up To 25 Kg To The Nearest 10 G. Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect , Buoyancy Balance The Buoyancy Balance Consists Of A Rigid Support Frame Incorporating A Water Tank Mounted On A Platform. A Mechanical Lifting Device Is Used To Raise The Water Tank Through The Frame Height Immersing The Specimen Suspended Below The Balance The Model Operates With An Electronic Top Pan Programmed Balance Of 15 Kg Capacity Readable To 0.5 G The Support Frame Comprises A Welded Steel Frame On Top Of Which Is Mounted The Top Loading Flat Pan Balance. A Cantilever Platform To Support The Immersion Tank Is Elevated By A Chain Attached To It And Operated By A Manually Operated Ratchet Mechanism. The Unit Incorporates An Immersed Weighing Tank Mounted On A Platform, Which Can Be Elevated By A Manual Action Ratchet Lifting Gear, To Allow The Test Specimen To Be Weighed In Air And Weighed In Water Using The Same Balance. , Laboratory Electric Hot Plates: Equipment Must Comprise Of Following Minimum Specification 1. Ss / Ms Top With Size Of 450Mm X600mmx150mm ( With Dimension Allowance Of ± 10 Mm ) 2. Thermostat Control And Regulator. 3. Energy Consumption Up To 2.0 Kw Opeational Of 220V ± 10 V, Single Phase, 50Hz Ac. ( Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect ) , Automatic Controlled Single Phase Stabilizer ( 10Kva ) . As Per Is Specifications Is 9815.Equipment Must Be Anindoor Floor Mounted Single Phase Automatic ( Copper Wound ) I / P Range 90V To 300V, Single Phase, O / P Of 230±4%, Frequency 50-60Hz, Air Colled Construction With U / V, O / V, O / L Protection System Equipment Must Have Working Temperaure Range - 5°C To 50°C, 95% Rh With Proper Insulation Resistance, Including Necessary Supply Of Quality Oil. ( Equipment Must Be Of Superior Make / Manufacture And Finish Complete In All Respect ) , Miscellaneous Items A ) . Superior Quality Borosilicate Bottles Of 50Ml Capacity With Capillary Bored Glass Stopper For Determination Of Specific Gravity Of Soil / Bitumen / Powders Etc. , Heat Resistance Safety Gloves Of Superior Quality , Natural High Grade Pigmented Heavy Duty Latex Hand Gloves Of Medium Size , Laboratory Apron Of Superior Make , Medium Size Ss Scoops / Trowels , Superior Quality And Make Heavy Duty Led Flash Light With Chargeable Battery , Superior Quality Masks , Knife / Spatula , Trichloroethylene , Glass Beaker 1 Ltr Capacity , General Tool Box , Ss Container ( 1 Litre ) With Lids , Disposable Aluminum Foil Containerwith Lids , Traffic Diversion Cones ( Delinators )

Key Value

Document Fees
INR 1100 /-
EMD
Refer document
Tender Value
INR 30 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail