}

Bids Are Invited For Hp Air System Port1 - Remove All Pipes And Chemically Clean As Per Ser Sow 3 (A) Size - 40 Mm,Mat - Ss , Hp Air System Port2 - (B) Size - 15 Mm, Mat - Ss , System Pipesbilge System3 - Remove All Pipes And Chemically Clean As Per Ser S-Goa

Department of Defence Production has published Bids Are Invited For Hp Air System Port1 - Remove All Pipes And Chemically Clean As Per Ser Sow 3 (A) Size - 40 Mm,Mat - Ss , Hp Air System Port2 - (B) Size - 15 Mm, Mat - Ss , System Pipesbilge System3 - Remove All Pipes And Chemically Clean As Per Ser S. Submission Date for this Tender is 18-01-2022. Coats and Jackets Tenders in Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30270153
Corrigendum : Bids Are Invited For Hp Air System Port1 - Remove All Pipes And Chemically Clean As Per Ser Sow 3 (A) Size - 40 Mm,Mat - Ss , Hp Air System Port2 - (B) Size - 15 Mm, Mat - Ss , System Pipesbilge System3 - Remove All Pipes And Chemically Clean As Per Ser S
Open Tender
Indian
Goa
18-01-2022

Tender Details

Bids Are Invited For Hp Air System Port1 - Remove All Pipes And Chemically Clean As Per Ser Sow 3 (A) Size - 40 Mm,Mat - Ss , Hp Air System Port2 - (B) Size - 15 Mm, Mat - Ss , System Pipesbilge System3 - Remove All Pipes And Chemically Clean As Per Ser Sow 3:- (A)Bilge And Eductor System(A)Mer Eductor System Pipe. (Material Cuni, Dia 100 Mm) , System Pipesbilge System4 - (B)Aer Eductor System Pipe. (Material Cuni, Dia 100 Mm) , System Pipesbilge System5 - (C)Mer Bilge System Pipe. (Material Cuni, Dia 40 Mm) , System Pipesbilge System6 - (D)Aer Bilge System Pipe. (Material Cuni, Dia 40 Mm) , System Pipesbilge System7 - (E)Bilge System Pipe. (Material - Cuni, Dia - 150 Mm) , System Pipesbilge System8 - (F) Bilge System Pipe. (Material - Cuni, Dia - 40 Mm) , System Pipesbilge System9 - (G)Bilge System Pipe. (Material - Cuni, Dia - 65 Mm) , System Pipesfire Main System10 - (C)Fire Main System. Remove All Pipes And Chemically Clean As Per Ser Sow 3 , System Pipesfire Main System11 - (A)Material Cuni (90-10), Dia 125 Mm , System Pipesfire Main System12 - (B)Material Cuni (90-10), Dia 100 Mm , System Pipesfire Main System13 - (C)Material Cuni (90-10), Dia 80 Mm , System Pipesfire Main System14 - (D)Material Cuni (90-10), Dia 65 Mm , System Pipesfire Main System15 - (E)Material Cuni (90-10), Dia 50 Mm , System Pipesfire Main System16 - (F) Material Cuni (90-10), Dia 20 Mm , System Pipesac Sea Water System17 - (D)A/C Sea Water System Remove All Pipes And Chemically Clean As Per Ser Sow 3 (A)Material Cuni, Dia 125 Mm , System Pipesac Sea Water System18 - (B)Material Cuni, Dia 100 Mm , System Pipesac Sea Water System19 - (C)Material Cuni, Dia 250 Mm , System Pipesac Sea Water System20 - (D)Material Cuni, Dia 40 Mm , System Pipesac Sea Water System21 - (E)Material Cuni, Dia 12 Mm , System Pipesac Chilled Water System22 - (E)A/C Chilled Water System Remove All Pipes And Chemically Clean As Per Ser Sow 3 , System Pipesac Chilled Water System23 - (A)Material Cuni, Dia 80 Mm , System Pipesfuel System24 - (F) Fuel Systemremove All Pipes And Chemically Clean As Per Ser Sow 3 (A)Material Ss, Dia 125 Mm , System Pipesfuel System25 - (B)Material Ss, Dia 80 Mm , System Pipesfuel System26 - (C)Material Ss, Dia 50 Mm , System Pipesfuel System27 - (D)Material Ss, Dia 65 Mm , System Pipesfuel System28 - (E)Material Ss, Dia 40 Mm , System Pipesfuel System29 - (F) Material Ss, Dia 32 Mm , System Pipesfuel System30 - (G)Material Ss, Dia 12 Mm , System Pipesballast System31 - (G)Ballast System Remove All Pipes And Chemically Clean As Per Ser Sow 3(A)Material Cuni, Dia 300 Mm , System Pipesballast System32 - (B)Material Cuni, Dia 200 Mm , System Pipesballast System33 - (C)Material Cuni, Dia 150 Mm , System Pipessalvage System34 - (H)Salvage Systemremove All Pipes And Chemically Clean As Per Ser Sow 3 (A)Material Cuni, Dia 200 Mm , System Pipessprinkling System35 - (J) Sprinkling Systemremove All Pipes And Chemically Clean As Per Ser Sow 3 (A)Material Cuni (90-10), Dia 50 Mm , System Pipessprinkling System36 - (B)Material Cuni (90-10), Dia 65 Mm , System Pipessprinkling System37 - (C)Material Cuni (90-10), Dia 40 Mm , System Pipessprinkling System38 - (D) Material Cuni (90-10), Dia 32 Mm , System Pipessprinkling System39 - (E)Material Cuni (90-10), Dia 25 Mm , System Pipesfresh Water System 40 - (L) Fresh Water System. Remove All Pipes And Chemically Clean As Per Ser Sow 3 , System Pipesfresh Water System 41 - (A)Material Cuni (90-10), Dia 65 Mm , System Pipesfresh Water System 42 - (B)Material Cuni (90-10), Dia 50 Mm , System Pipesfresh Water System 43 - (C)Material Cuni (90-10), Dia 40 Mm , System Pipesfresh Water System 44 - (D) Material Cuni (90-10), Dia 20 Mm , Dasea Water System45 - Remove And Pressure Test Following Pipe Lines As Per Ser Sow 3:-(A) 80 Mm, Mat- Cuni 90/10, No Of Flanges - 80 , Dasea Water System46 - (B) 40 Mm, Mat- Cuni 90/10, No Of Flanges - 60 , Hp Air System Port47 - Renew Following Defective Pipes As Per Sow 4: - (A) Size - 40 Mm, Mat - Ss , Hp Air System Port48 - (B) Size - 15 Mm, Mat - Ss , System Pipesbilge System49 - Replace Following Pipes As Per Ser Sow 4:-(A)Bilge And Eductor System (A)Mer Eductor System Pipe. (Material Cuni, Dia 100 Mm) , System Pipesbilge System50 - (B)Aer Eductor System Pipe. (Material Cuni, Dia 100 Mm) , System Pipesbilge System51 - (C)Mer Bilge System Pipe. (Material Cuni, Dia 40 Mm) , System Pipesbilge System52 - (D)Aer Bilge System Pipe. (Material Cuni, Dia 40 Mm) , System Pipesbilge System53 - (E)Bilge System Pipe. (Material - Cuni, Dia - 150 Mm) , System Pipesbilge System54 - (F) Bilge System Pipe. (Material - Cuni, Dia - 40 Mm) , System Pipesbilge System55 - (G)Bilge System Pipe. (Material - Cuni, Dia - 65 Mm) , System Pipesfire Main System56 - (C)Fire Main System. Renew Following Defective Pipes As Per Sow 4 , System Pipesfire Main System57 - (A)Material Cuni (90-10), Dia 125 Mm , System Pipesfire Main System58 - (B)Material Cuni (90-10), Dia 100 Mm , System Pipesfire Main System59 - (C)Material Cuni (90-10), Dia 80 Mm , System Pipesfire Main System60 - (D)Material Cuni (90-10), Dia 65 Mm , System Pipesfire Main System61 - (E)Material Cuni (90-10), Dia 50 Mm , System Pipesfire Main System62 - (F) Material Cuni (90-10), Dia 20 Mm , System Pipesac Sea Water System63 - (D)A/C Sea Water Systemrenew Following Defective Pipes As Per Sow 4(A)Material Cuni, Dia 125 Mm , System Pipesac Sea Water System64 - (B)Material Cuni, Dia 100 Mm , System Pipesac Sea Water System65 - (C)Material Cuni, Dia 250 Mm , System Pipesac Sea Water System66 - (D)Material Cuni, Dia 40 Mm , System Pipesac Sea Water System67 - (E)Material Cuni, Dia 12 Mm , System Pipesac Chilled Water System68 - (E)A/C Chilled Water System Renew Following Defective Pipes As Per Sow 4 , System Pipesac Chilled Water System69 - (A)Material Cuni, Dia 125 Mm , System Pipesac Chilled Water System70 - (B)Material Cuni, Dia 100 Mm , System Pipesac Chilled Water System71 - (C)Material Cuni, Dia 250 Mm , System Pipesac Chilled Water System72 - (D)Material Cuni, Dia 40 Mm , System Pipesac Chilled Water System73 - (E)Material Cuni, Dia 12 Mm , System Pipesfuel System74 - (F) Fuel System Renew Following Defective Pipes As Per Sow 4(A)Material Ss, Dia 125 Mm , System Pipesfuel System75 - (B)Material Ss, Dia 80 Mm , System Pipesfuel System76 - (C)Material Ss, Dia 50 Mm , System Pipesfuel System77 - (D)Material Ss, Dia 65 Mm , System Pipesfuel System78 - (E)Material Ss, Dia 40 Mm , System Pipesfuel System79 - (F) Material Ss, Dia 32 Mm , System Pipesfuel System80 - (G)Material Ss, Dia 12 Mm , System Pipesballast System81 - (G)Ballast Systemrenew Following Defective Pipes As Per Sow 4(A)Material Cuni, Dia 300 Mm , System Pipesballast System82 - (B)Material Cuni, Dia 200 Mm , System Pipesballast System83 - (C)Material Cuni, Dia 150 Mm , System Pipessalvage System84 - (H)Salvage System Renew Following Defective Pipes As Per Sow 4(A)Material Cuni, Dia 200 Mm , System Pipessprinkling System85 - (J) Sprinkling System Renew Following Defective Pipes As Per Sow 4(A)Material Cuni (90-10), Dia 50 Mm , System Pipessprinkling System86 - (B)Material Cuni (90-10), Dia 65 Mm , System Pipessprinkling System87 - (C)Material Cuni (90-10), Dia 40 Mm , System Pipessprinkling System88 - (D) Material Cuni (90-10), Dia 32 Mm , System Pipessprinkling System89 - (E)Material Cuni (90-10), Dia 25 Mm , System Pipesfresh Water System 90 - (L) Fresh Water Systemrenew Following Defective Pipes As Per Sow 4 , System Pipesfresh Water System 91 - (A)Material Cuni (90-10), Dia 65 Mm , System Pipesfresh Water System 92 - (B)Material Cuni (90-10), Dia 50 Mm , System Pipesfresh Water System 93 - (C)Material Cuni (90-10), Dia 40 Mm , System Pipesfresh Water System 94 - (D) Material Cuni (90-10), Dia 20 Mm , System Pipeslub Oil System95 - Remove And Pressure Test Following Pipe Lines As Per Ser Sow 3(K)Lub Oil System(A)Material Ms, Dia 50 Mm , System Pipeslub Oil System96 - (B)Material Ms, Dia 25 Mm , System Pipeslub Oil System97 - (C)Material Ms, Dia 20 Mm , System Pipeslub Oil System98 - (D)Material Ms, Dia 15 Mm , Dafuel System99 - Remove And Pressure Test Following Pipe Lines As Per Ser Sow 3:-(B) Size - 32 Mm, Mat - Ms, No Of Flanges - 38 , System Pipeslub Oil System100 - (K)Lub Oil Systemrenew Following Defective Pipes As Per Sow 4 (A)Material Ms, Dia 50 Mm , System Pipeslub Oil System101 - (B)Material Ms, Dia 25 Mm , System Pipeslub Oil System102 - (C)Material Ms, Dia 20 Mm , System Pipeslub Oil System103 - (D)Material Ms, Dia 15 Mm , Ships Tanksounding Tubes104 - Replace Sounding Tubes Of Tanks As Per Ser Sow 4.Size - 60 Mm, Length - 10 M, , Deck Filling Points105 - Replace Deck Filling Points. Scope Of Work Includes The Following:-(A) Removal Of Deck Filling Cap Including Necessary Hot Work, Cutting/ Grinding. Mat - Brass,Manufacturing Of New Deck Filling Cap Per Sample. Mat - Brass, Manufacturing Of Deck Filling Goose Neck As Per Sample. Mat - Ms. Renewal Of Joints And Fasteners For Fitment Of Goose Neck. , Deck Filling Points106 - Replace Deck Filling Points. Scope Of Work Includes The Following:-No Of Deck Filling Points As Follows:-(A) 03 Fresh Water Filling Point, 04 Fuel Filling Point (Location - 02 In Foxle, 02 In Boat Deck), 01 Avcat Filling Point (Location - Helo Deck), 03 Lub Oil Filling Point (Location - Port & Stbd Catwalk) , Tanks , Pipe Lines107 - All Tanks Having System Pipes Carrying Seawater/ Fresh Water Inside Or Outside Are To Be Examined At Flanges/ Joints And Throughout The Length For Any Leakages. Repair/ Renew As Necessary , Tanks , Sounding Pipes108 - Sounding Pipe Of All Tanks With Caps To Be Renewed. , Battery Charging Room Drain109 - Drain Line In Battery Charging Room To Be Renewed. Mat Gi Pipe Dia40mm. Length 3 Mtrs , Ventilation System, Breather Pipes110 - Repair/ Renewal Of Breather Pipes Of Tanks , Sewage Treatment Plant 111 - (J) Renew All Cu-Ni Pipelines And Joints In All Four Stps , Galley , Galley Drain Line112 - (A) Renew Drain Line Of Ships Galley, Officers Galley, Troops Galley And Pantries.Material- Gi Pipes, Average Dia Of Pipe- 120 Mm (B) Work Involves (I) Removal Of Old Pipe To Shop Floor.(Ii) Chemical Cleaning Of Pipes, If Requierd Manufacture Of New Pipes With End Fittings.(Iii) Check The Deck And Bulkheadflanges If Required Manufacture Of Deck And Bulkhead Flanges.(Iv)Fitment Of New Pipes With End Fittings, Gaskets, Fastners And With Rubber Packing In Clamps .(V) On Fitment Firmto Prove Leak Test Of Drain Lines Onboard.(Vi) Refitment Of Panneling And Lagging. , Drainage System , Deck Drain Strainers113 - (A) Renew Drain Pipes On Weather Decks And Wet Compartments With Flanges, Deck Flanges/ Joints, Gasket And Securing Clamps. Work Involves Removal Of Existing Lines, Templates/ Gauging And Fitment On One On One Basis , Vehicle Ramp Renewal114 - Vehicle Ramp Drain Pipe To Be Renewed. Mat Flexiable Pipe, Dia- 100Mm, Length 1.5M , Sewage Treatment Plant,Overhauling Of Valves115 - Overhaul All Valves Of Sewage Treatement Plant / System.Approx 15 Nos Valves In Each Plant.( System Valves, 150Mm -05 ) (I) Remove Valve From Pipe Line. (Ii)Clean, Dismantle And Guage The Valve. (Iii)Renew The Consumables. (Iv)Lubricate All Moving Parts (V) Assemble The Valve (Vi)Pressure To 01 Bar Pressure And Prove Pressure To Ship Staff And Refit Monitoring Team.(Vii)Fit Valve In Pipe Line And Prove For Nil Leakage. , Domestic Fresh Water System Isolating Valves116 - (A) Open, Overhaul And Refit All Isolating Valves / Taps / Bibcockof Fresh Watersupply Line In All Bathroom, Wcs, Enclosed Bridge, Officers Cabin And Sculleries. (B) Renew Defective Valves. (C) Renewal 50 Valves. (D) Removal Of Panneling , Lagging To Facilitate Pipe Removal. , Storm Valves , Storm Valves117 - (A) Remove, Overhaul And Refit All Storm Valves. Details As Follows (I) 50Nb – 12 Nos (Ii)80Nb – 11 Nos (Iii) 100Nb – 3 Nos (Iv) 125Nb – 2Nos (C) Pressure Test All Storm Valves To 1.5 Bar Post Overhauling (D) Prove Serviceability Of Valves To Shipstaff Post Fitment. , Overboard Discharges , Overboard Discharges118 - (A) Remove, Overhaul And Refit All Obd Valve And Sdnr Valves. Location Of Valve Will Be Indicated By Shipstaff. (B)Prove Serviceability Of Valves To Shipstaff Post Fitment. (C) Types Of Angle Sdnr Globe Valves Are As Follows; (I) 65Nb- 10Nos (Ii) 40Nb- 05Nos (Iii) 25Nb- 12Nos (Iv) 50Nb- 05Nos(V)100Nb- 04Nos(Vi) 200Nb- 08Nos (E) Types Of Discharge Valves Flange Ended Are As Follows;(I) 100Nb- 04Nos(Ii) 200Nb- 02Nos (F) Types Of Sdnrv Valves Are As Follows; (I) 100Nb- 08Nos (Ii) 65Nb- 08 , Dasea Water System119 - Overhaul Following Valves As Per Ser Sow 1:- (A) 80 Mm Sdnr Valve, Mat- Gm , Dasea Water System120 - (B) 100 Mm Angle Sdnr Valve, Mat - Gm , Dasea Water System121 - (C) 80 Mm Angle Sdnr Valve, Mat - Gm , Dasea Water System122 - (D) 40 Mm Sdnr Valve , Dafuel System123 - Overhaul Following Valves As Per Ser Sow 1:-(A) 32 Mm Globe Valve , Both Main Engines Main Engine Sw Circulating System124 - Overhaul Following Valves As Per Ser Sow 1: - , Both Main Engines Main Engine Sw Circulating System125 - (C) 200 Mm Sdnr Valve , Both Main Engines Main Engine Sw Circulating System126 - (D) 150 Mm Sdnr Valve , Both Main Engines Main Engine Sw Circulating System127 - (E) 50 Mm Sdnr Valve , Both Main Engines Main Engine Fresh Water Cooling System128 - Overhaul Following Valves As Per Ser Sow 1: -(A) 40 Mm Sdnr Valve , Both Main Engines Main Engine Fuel System129 - Overhaul Following Valves As Per Ser Sow 1: - (A) 32 Mm 3/2 Fuel Pneumatic Valve , Both Main Engines Main Engine Fuel System130 - (B) 32 Mm Screw Down Valve , Both Main Engines Main Engine Fuel System131 - (C) 32 Mm Ball Valve , Gear Box Portsea Water System132 - Overhaul Sea Water System Valves As Per Ser Sow 1. Size - 65 Mm, Type - Globe Valve , Gear Box Stbdsea Water System133 - Overhaul Sea Water System Valves As Per Ser Sow 1. Size - 65 Mm, Type - Globe Valve , Deep Sea Seal Sea Water System134 - Overhaul Following Stern Tube Lub Oil System Valves As Per Sow 1:-(A) 40 Mm Sdnr Valve , Deep Sea Seal Sea Water System135 - (B) 25 Mm Globe Valve , Deep Sea Seal Sea Water System136 - (C) 20 Mm Globe Valve , Deep Sea Seal Sea Water System137 - (D) 20 Mm 3-Way Cock , Deep Sea Seal Sea Water System138 - (E) 10 Mm Globe Valve , Hp Air System Port139 - Overhaul Following Valves As Per Ser Sow 1: -(A) 12 Mm Teflon Seat Valve , Hp Air System Port140 - (B) 1/2 Cock , Hp Air System Port141 - (C) 40 Mm Sdnr Valve , Hp Air System Port142 - Remove All Pipes And Chemically Clean As Per Ser Sow 3 (A) Size - 40 Mm,Mat - Ss , Hp Air System Port143 - (B) Size - 15 Mm, Mat - Ss , Hp Air System Stbd144 - Overhaul Following Valves As Per Ser Sow 1: -(A) 12 Mm Teflon Seat Valve , Hp Air System Stbd145 - (B) 1/2 Cock , Hp Air System Stbd146 - (C) 40 Mm Sdnr Valve , Ows Bilge Pump147 - (E) Overhaul System Valves As Per Sow 1 , Ows Bilge Pump148 - (I)Gate Valve, 50 Mm. , Ows Bilge Pump149 - (Ii)Sdnr Valve, 65 Mm , Ows Bilge Pump150 - (Iii)Gate Valve, 15 Mm , Ows Bilge Pump151 - (Iv)Gate Valve, 25 Mm , System Valvesgearbox, Cpp, Shafting152 - Overhaul Following Valves As Per Ser Sow 1(A)Gear Box, Cpp, Shafting System Valves (In Mer) (I)Sd Vv, 50 Mm , System Valvesgearbox, Cpp, Shafting153 - (Ii) Sd Vv, 40 Mm , System Valvesgearbox, Cpp, Shafting154 - (Iii)Sd Vv, 25 Mm , System Valvesgearbox, Cpp, Shafting155 - (Iv)Sd Vv, 15 Mm , System Valvesgearbox, Cpp, Shafting156 - (V) Cocks, 25 Mm , System Valveslo Centrifuge157 - Overhaul Following Valves As Per Ser Sow 1 (B)Lub Oil Centrifuge System Valves (In Mer)(I)Sd Vv, 40 Mm , System Valveslo Centrifuge158 - (Ii) Sd Vv, 15 Mm , System Valvesfo Centrifuge159 - Overhaul Following Valves As Per Ser Sow 1(C)Fuel Oil Centrifuge System Valves (In Mer) , System Valvesfo Centrifuge160 - (I)Sd Vv, 40 Mm , System Valvesfo Centrifuge161 - (Ii) Sd Vv, 15 Mm , System Valvessteering Gear162 - Overhaul Following Valves As Per Ser Sow 1(D)Steering System Valves (In Asp)(I)Sd Vv, 25 Mm , System Valvesme Air System163 - (E)Main Engine Air System Valves (In Mer)(I)Sd Vv, 40 Mm , System Valvesme Air System164 - (Ii) Cocks, 15 Mm , System Valvesdiesel Alternator (Mer)165 - Overhaul Following Valves As Per Ser Sow 1 (F)Diesel Alternator (In Mer)(I)Sd Vv, 100 Mm , System Valvesdiesel Alternator (Mer)166 - (Ii) Sdnr Vv, 100 Mm , System Valvesdiesel Alternator (Mer)167 - (Iii)Sd Vv, 100 Mm , System Valvesdiesel Alternator (Mer)168 - (Iv)Sd Vv, 80 Mm , System Valvesdiesel Alternator (Mer)169 - (V) Sd Vv, 50 Mm , System Valvesdiesel Alternator (Mer)170 - (Vi)Sd Vv, 65 Mm , System Valvesdiesel Alternator (Aer)171 - (G)Diesel Alternator (In Aer) (I)Sd Vv, 80 Mm (Da Emergency Vv) , System Valvesdiesel Alternator (Aer)172 - (Ii) Sdnr Vv, 100 Mm , System Valvesdiesel Alternator (Aer)173 - (Iii)Sd Vv, 80 Mm , System Valvesdiesel Alternator (Aer)174 - (Iv)Sd Vv, 50 Mm , System Valvesdiesel Alternator (Aer)175 - (V)Sd Vv, 65 Mm , System Valvesdiesel Alternator (Aer)176 - (Vi)Sd Vv, 100 Mm , System Valvesdiesel Alternator (Aer)177 - (Vii) Butterfly Vv, 200 Mm , System Valvesdiesel Alternator (Aer)178 - (Viii)Butterfly Vv, 100 Mm , System Valves Ro Plant (Aer)179 - Overhaul Following Valves As Per Ser Sow 1(H)Ro Plant (In Aer) (I)Sd Vv, 32 Mm , System Valves Ro Plant (Aer)180 - (Ii) Sd Vv, 25 Mm , System Valves Ro Plant (Aer)181 - (Iii)Sdnr Angle Vv, 32 Mm , System Valvesac And Ref Plant182 - Overhaul Following Valves As Per Ser Sow 1(J)A/C And Ref Plant (In A/C Comp) (I)Gate Vv, 80 Mm , System Valvesac And Ref Plant183 - (Ii) Sd Vv, 100 Mm , System Valvesac And Ref Plant184 - (Iii)Sd Vv, 125 Mm , System Valvesac And Ref Plant185 - (Iv)Reducing Vv, 250 Mm , System Valvesac And Ref Plant186 - (V) Sd Vv, 65 Mm , System Valvesac And Ref Plant187 - (Vi)Sd Vv, 25 Mm , System Valvesac And Ref Plant188 - (Vii) Cocks 15 Mm , System Valvesac Chilled Water System189 - (K)A/C Chilled Water System (Scattered) (I)Sd Vv, 125 Mm (Isolating Vv) , System Valvesac Chilled Water System190 - (Ii) Sd Vv, 80 Mm (Atus) , System Valvesac Chilled Water System191 - (Iii)Sd Vv, 15 Mm (Atus) , System Valvesac Chilled Water System192 - (Iv)Cocks, 15 Mm (Atus) , System Valveshp Air System193 - Overhaul Following Valves As Per Ser Sow 1(L)Hp Air System (In Aer Annex) (Renew All Teflon Seats)(I)Sd Vv, 40 Mm , System Valveshp Air System194 - (Ii) Sd Vv, 25 Mm , System Valveshp Air System195 - (Iii)Sd Vv, 20 Mm , System Valveshp Air System196 - (Iv)Cocks, 20 Mm , System Valveshp Air System197 - (V) Sd Globe Vv, 15 Mm , System Valveshp Air System198 - (Vi)Sd Globe Vv, 6 Mm , System Valveshp Air System199 - (Vii) Sd Globe Vv, 10 Mm , System Valvesbilge System200 - Overhaul Following Valves As Per Ser Sow 1(M)Bilge System (Scattered)(I)Sdnr Vv, 50 Mm (Suction Vv) , System Valvesbilge System201 - (Ii) Sdnr Vv, 50 Mm (Overboard Vv) , System Valvesbilge System202 - (Iii)Sdnr Vv, 50 Mm (Aux. Bilge Pp Overboard Vv) , System Valvesfresh Water System 203 - Overhaul Following Valves As Per Ser Sow 1(P)Fresh Water System (Scattered) (I)Sdnr, 50 Mm (Pp Suc And Dis) , System Valvesfresh Water System 204 - (Ii) Sdnr, 40 Mm , System Valvesfresh Water System 205 - (Iii)Sd Globe Valve, 25 Mm , System Valvesfresh Water System 206 - (Iv)Ball Valve, 25 Mm , System Valvesfresh Water System 207 - (V)Ball Valve, 40 Mm , System Valvesfresh Water System 208 - (Vi)Sd Globe Valve, 40 Mm , System Valvesfresh Water System 209 - (Vii)Sd Globe Valve, 100 Mm , System Valveslub Oil System210 - Overhaul Following Valves As Per Ser Sow 1(Q) Lub Oil System(I) Sd Globe Vv, 50 Mm , System Valveslub Oil System211 - (Ii) Sd Globe Vv, 25 Mm , System Valveslub Oil System212 - (Iii) Sd Nr Vv, 25 Mm , System Valveslub Oil System213 - (Iv) Sd Globe Vv, 40 Mm , System Valveslub Oil System214 - (V) Sdnr Globe Vv, 20 Mm , System Valveslub Oil System215 - (Vi) Sdnr Globe Vv, 65 Mm , System Valveslub Oil System216 - (Vii) Sd Globe Vv, 125 Mm , System Valvesfuel System217 - Overhaul Following Valves As Per Ser Sow 1(R)Fuel System (Scattered)(I)Sd Globe Vv, 125 Mm , System Valvesfuel System218 - (Iii)Sd Globe Vv, 100 Mm , System Valvesfuel System219 - (Iv)Quick Shut Off Vv (M/Es And D/As) , System Valvesfuel System220 - (V) Quick Shut Off Vv (Fuel Tanks) , System Valvesfuel System221 - (Vii)Sd Globe Vv, 80 Mm , System Valvesfuel System222 - (Viii)Sd Globe Vv, 65 Mm , System Valvesfuel System223 - (Vi)Ball Vv, 65 Mm , System Valves Ballast System224 - Overhaul Following Valves As Per Ser Sow 1 (S)Ballast System (Scattered)(I)Gate Vv, 200 Mm , System Valves Ballast System225 - (Iv)Sdnr Globe Vv, 200 Mm , System Valvessalvage System226 - Overhaul Following Valves As Per Ser Sow 1(Ii) Gate Vv, 200 Mm , System Valvessalvage System227 - (Iv)Gate Vv, 200 Mm (Rod Gearing Arrangement) , System Valvessalvage System228 - (V) Angular Sdnr Globe Vv, 200 Mm , System Valvesfire Main System229 - Overhaul Following Valves As Per Ser Sow 1 (Ii) Sd Vv, 125 Mm , System Valvesfire Main System230 - (Iii)Double Face Sluice Vv, 125 Mm , System Valvesfire Main System231 - (V) Sd Globe Vv, 65 Mm , System Valvesfire Main System232 - (Vi)Sd Globe Vv, 65 Mm (Rod Gearing Arrangement) , System Valvesfire Main System233 - (Vii) Sd Globe Vv, 50 Mm , System Valvesfire Main System234 - (Ix)Sdnr Globe Vv, 200 Mm , System Valvesfire Main System235 - (X) Sdnr Globe Vv, 80 Mm , System Valvesfire Main System236 - (Xi)Sd Globe Vv, 50 Mm , System Valvessprinkling System237 - Overhaul Following Valves As Per Ser Sow 1 (Q)Sprinkling System (Scattered) (I)Sd Globe Vv, 50 Mm , System Valvessprinkling System238 - (Ii) Sd Globe Vv, 65 Mm , Remote Control Valves Motorised Actuator239 - Overhaul Motorised Actuators Of Remote Control Valves. Scope Of Work Includes:-(A) Removal Of Old Actuators.,Removal Of Old Cabling From Valve Actuator To Local Control Panel, Overhauling Of Actuator, Fitment Of Overhauled Actuator, Renewal Of Associated Joints,Replacement Of All Associated Fasteners,Renewal Of Cabling From Local Control Panel To Valve Actuator., Operation Of Remote Control Valves To Be Proved Manually, From Local Control Panel And From Ipms. , Remote Control Valves Mechanical Valve240 - Overhaul Following Remote Control Valves As Per Sow 1. List Of Rcvs Placed At Appendix J.(A) 125 Mm Globe Valve -17 Nos,125 Mm Sluice Valve- 01 Nos,150 Mm Globe Valve- 08 Nos, 150 Mm Sdnr Valve- 19 Nos, 200 Mm Gate Valve- 19 Nos, 200 Mm Sdnr- 29 Nos, 40 Mm Globe Valve- 06 Nos,50 Mm Ball Valve-10 Nos,50 Mm Glove Valve-07 Nos,50 Mm Sdnr Valve-03 Nos, 65 Mm Globe Valve-05 Nos,80 Mm Ball Valve- 08 Nos , Both Main Engines Main Engine Sw Circulating System241 - Replace Following Valves As Per Ser Sow 2: - (A) 250 Mm Butterfly Valve , Both Main Engines Main Engine Sw Circulating System242 - (B) 200 Mm Flap Valve , Both Main Engines Main Engine Sw Circulating System243 - (C) 200 Mm Sdnr Valve , Both Main Engines Main Engine Sw Circulating System244 - (D) 150 Mm Sdnr Valve , Both Main Engines Main Engine Sw Circulating System245 - (E) 50 Mm Sdnr Valve , Both Main Engines Main Engine Sw Circulating System246 - (F) 300 Mm Sdnr Sea Chest Valve , Both Main Engines Main Engine Fresh Water Cooling System247 - Replace Following Valves As Per Ser Sow 2: - (A) 40 Mm Sdnr Valve , Both Main Engines Main Engine Fuel System248 - Replace Following Valves As Per Ser Sow 2: - (A) 32 Mm 3/2 Fuel Pneumatic Valve , Both Main Engines Main Engine Fuel System249 - (B) 32 Mm Screw Down Valve , Both Main Engines Main Engine Fuel System250 - (C) 32 Mm Ball Valve , Hp Air System Port251 - Replace Following Valves As Per Ser Sow 2: -(A) 12 Mm Teflon Seat Valve , Hp Air System Port252 - (B) 40 Mm Sdnr Valve , Hp Air System Stbd253 - Replace Following Valves As Per Ser Sow 2: -(A) 12 Mm Teflon Seat Valve , Hp Air System Stbd254 - (B) 40 Mm Sdnr Valve , Both Ro Plantsea Water System255 - Replace Following Sea Water System Valves As Per Sow 2:-(A) 40 Mm Sdnr Valve , System Valvesgearbox, Cpp, Shafting256 - Replace Following Valves And Components As Per Ser Sow 2:- (A)Gear Box, Cpp, Shafting System Valves (In Mer) (I)Sd Vv, 50 Mm , System Valvesgearbox, Cpp, Shafting257 - (Ii) Sd Vv, 40 Mm , System Valvesgearbox, Cpp, Shafting258 - (Iii)Sd Vv, 25 Mm , System Valvesgearbox, Cpp, Shafting259 - (Iv)Sd Vv, 15 Mm , System Valvesgearbox, Cpp, Shafting260 - (V) Cocks, 25 Mm , System Valveslo Centrifuge261 - Replace Following Valves As Per Ser Sow 2(B)Lub Oil Centrifuge System Valves (In Mer) (I)Sd Vv, 40 Mm , System Valveslo Centrifuge262 - (Ii) Sd Vv, 15 Mm , System Valvesfo Centrifuge263 - (C)Fuel Oil Centrifuge System Valves (In Mer) (I)Sd Vv, 40 Mm , System Valvesfo Centrifuge264 - (Ii) Sd Vv, 15 Mm , System Valvessteering Gear265 - Replace Following Valves As Per Ser Sow 2 (D)Steering System Valves (In Asp)(I)Sd Vv, 25 Mm , System Valvessteering Gear266 - (Ii) Distribution Block (Set Of 10 Valves) , System Valvesme Air System267 - Replace Following Valves As Per Ser Sow 2(E)Main Engine Air System Valves (In Mer)(I)Sd Vv, 40 Mm , System Valvesme Air System268 - (Ii) Cocks, 15 Mm , System Valvesme Air System269 - (Iii)Reducer (30 Bar To 7 Bar) , System Valvesdiesel Alternator (Mer)270 - Replace Following Valves As Per Ser Sow 2 (F)Diesel Alternator (In Mer)(I)Sd Vv, 100 Mm , System Valvesdiesel Alternator (Mer)271 - (Ii) Sdnr Vv, 100 Mm , System Valvesdiesel Alternator (Mer)272 - (Iii)Sd Vv, 100 Mm , System Valvesdiesel Alternator (Mer)273 - (Iv)Sd Vv, 80 Mm , System Valvesdiesel Alternator (Mer)274 - (V) Sd Vv, 50 Mm , System Valvesdiesel Alternator (Mer)275 - (Vi)Sd Vv, 65 Mm , System Valvesdiesel Alternator (Aer)276 - (G)Diesel Alternator (In Aer) (I)Sd Vv, 80 Mm (Da Emergency Vv) , System Valvesdiesel Alternator (Aer)277 - (Ii) Sdnr Vv, 100 Mm , System Valvesdiesel Alternator (Aer)278 - (Iii)Sd Vv, 80 Mm , System Valvesdiesel Alternator (Aer)279 - (V)Sd Vv, 65 Mm , System Valvesdiesel Alternator (Aer)280 - (Vi)Sd Vv, 100 Mm , System Valvesdiesel Alternator (Aer)281 - (Vii) Butterfly Vv, 200 Mm , System Valvesro Plant (Aer)282 - Replace Following Valves As Per Ser Sow 2 (H)Ro Plant (In Aer) (I)Sd Vv, 32 Mm , System Valvesro Plant (Aer)283 - (Ii) Sd Vv, 25 Mm , System Valvesac And Ref Plant284 - Replace Following Valves As Per Ser Sow 2 (J)A/C And Ref Plant (In A/C Comp)(I)Gate Vv, 80 Mm , System Valvesac And Ref Plant285 - (Ii) Sd Vv, 100 Mm , System Valvesac And Ref Plant286 - (Iii)Sd Vv, 125 Mm , System Valvesac And Ref Plant287 - (V) Sd Vv, 65 Mm , System Valvesac And Ref Plant288 - (Vi)Sd Vv, 25 Mm , System Valvesac And Ref Plant289 - (Vii) Cocks 15 Mm , System Valvesac Chilled Water System290 - Replace Following Valves As Per Ser Sow 2 (K)A/C Chilled Water System (Scattered) (I)Sd Vv, 125 Mm (Isolating Vv) , System Valvesac Chilled Water System291 - (Ii) Sd Vv, 80 Mm (Atus) , System Valvesac Chilled Water System292 - (Iii)Sd Vv, 15 Mm (Atus) , System Valvesac Chilled Water System293 - (Iv)Cocks, 15 Mm (Atus) , System Valveshp Air System294 - Replace Following Valves As Per Ser Sow 2 (L)Hp Air System (In Aer Annex) (Renew All Teflon Seats) (I)Sd Vv, 40 Mm , System Valveshp Air System295 - (Ii) Sd Vv, 25 Mm , System Valveshp Air System296 - (Iii)Sd Vv, 20 Mm , System Valveshp Air System297 - (Iv)Cocks, 20 Mm , System Valveshp Air System298 - (V) Sd Globe Vv, 15 Mm , System Valveshp Air System299 - (Vi)Sd Globe Vv, 6 Mm , System Valveshp Air System300 - (Vii) Sd Globe Vv, 10 Mm , System Valveshp Air System301 - (Ix)Pressure Reducer (30 Bar To 7 Bar) , System Valveshp Air System302 - (X) Pressure Reducer (7 Bar To 1.5 Bar) , System Valvesbilge System303 - Replace Following Valves As Per Ser Sow 2(M)Bilge System (Scattered) (I)Sdnr Vv, 50 Mm (Suction Vv) , System Valvesbilge System304 - (Ii) Sdnr Vv, 50 Mm (Overboard Vv) , System Valvesbilge System305 - (Iii)Sdnr Vv, 50 Mm (Aux. Bilge Pp Overboard Vv) , System Valvesfresh Water System 306 - Replace Following Valves As Per Ser Sow 2 (P)Fresh Water System (Scattered)(I)Sdnr, 50 Mm (Pp Suc And Dis) , System Valvesfresh Water System 307 - (Ii) Sdnr, 40 Mm , System Valvesfresh Water System 308 - (Iii)Sd Globe Valve, 25 Mm , System Valvesfresh Water System 309 - (Vii)Sd Globe Valve, 100 Mm , System Valveslub Oil System310 - Replace Following Valves As Per Ser Sow 2(Q) Lub Oil System(I) Sd Globe Vv, 50 Mm , System Valveslub Oil System311 - (Iv) Sd Globe Vv, 40 Mm , System Valveslub Oil System312 - (V) Sdnr Globe Vv, 20 Mm , System Valveslub Oil System313 - (Vi) Sdnr Globe Vv, 65 Mm , System Valveslub Oil System314 - (Vii) Sd Globe Vv, 125 Mm , System Valvesfuel System315 - Replace Following Valves As Per Ser Sow 2 (R)Fuel System (Scattered) (I)Sd Globe Vv, 125 Mm , System Valvesfuel System316 - (Iii)Sd Globe Vv, 100 Mm , System Valvesfuel System317 - (Iv)Quick Shut Off Vv (M/Es And D/As) , System Valvesfuel System318 - (V) Quick Shut Off Vv (Fuel Tanks) , System Valvesfuel System319 - (Vii)Sd Globe Vv, 80 Mm , System Valvesfuel System320 - (Viii)Sd Globe Vv, 65 Mm , System Valvesfuel System321 - (Vi)Ball Vv, 65 Mm , System Valvesballast System322 - Replace Following Valves As Per Ser Sow 2 (S)Ballast System (Scattered)(I)Gate Vv, 200 Mm , System Valvesballast System323 - (Iv)Sdnr Globe Vv, 200 Mm , System Valvessalvage System324 - Replace Following Valves As Per Ser Sow 2 (Ii) Gate Vv, 200 Mm , System Valvessalvage System325 - (Iv)Gate Vv, 200 Mm (Rod Gearing Arrangement) , System Valvessalvage System326 - (V) Angular Sdnr Globe Vv, 200 Mm , System Valvesfire Main System327 - Replace Following Valves As Per Ser Sow 2 (Ii) Sd Vv, 125 Mm , System Valvesfire Main System328 - (Iii)Double Face Sluice Vv, 125 Mm , System Valvesfire Main System329 - (V) Sd Globe Vv, 65 Mm , System Valvesfire Main System330 - (Vi)Sd Globe Vv, 65 Mm (Rod Gearing Arrangement) , System Valvesfire Main System331 - (Vii) Sd Globe Vv, 50 Mm , System Valvesfire Main System332 - (Ix)Sdnr Globe Vv, 200 Mm , System Valvesfire Main System333 - (X) Sdnr Globe Vv, 80 Mm , System Valvesfire Main System334 - (Xi)Sd Globe Vv, 50 Mm , System Valvessprinkling System335 - Replace Following Valves As Per Ser Sow 2(Q)Sprinkling System (Scattered)(I)Sd Globe Vv, 50 Mm , System Valvessprinkling System336 - (Ii) Sd Globe Vv, 65 Mm , Under Water Valves337 - (A) Replace Following Underwater Valves As Per Ser Sow 2 As Part Of Dry Dock Work Package. Quote To Be Inclusive Of All Spares And Proving Valves On Board During Trials. , Under Water Valves338 - (B)Paint One Coat Of Primer Coat Of Underwater Paint Scheme Prior Fitment Onboard. , Under Water Valves339 - Mer Compartment (2 Inner And 2 Outer Sea Chest)(A)Mer Sea Chest, 300 Mm (Stbd) , Under Water Valves340 - (B)Mer Sea Chest, 250 Mm (Port) , Under Water Valves341 - (C)Mer Fire Pump, 150 Mm , Under Water Valves342 - (D)Stand By Sea Water Pump For Main Engines, 150 Mm , Under Water Valves343 - (E)Diesel Alternator Suction Vv, 100 Mm (M1 And M2) , Under Water Valves344 - (F) Salvage Pump Suction Vv, 150 Mm (In Mer) , Under Water Valves345 - (G)Sea Chest Blow Through Vv, 50 Mm (In Mer) , Under Water Valves346 - (H)Ows Suction Vv, 50 Mm , Under Water Valves347 - Aer Compartment (2 Outer Sea Chest ) (A)Aer Sea Chest, 200 Mm , Under Water Valves348 - (B)Diesel Alternator Suction Vv, 80 Mm (L1 And L2) , Under Water Valves349 - (C)Ro Plant Feed Pp Suction Vv, 65 Mm , Under Water Valves350 - Pump Rooms (4 Sea Chest) (A)Main Sea Chest Vv, 200 Mm , Under Water Valves351 - A/C Pump Room (One Sea Chest) (A)Main Sea Chest Vv, 250 Mm , Under Water Valves352 - Magazine Flooding Vv (One Sea Chest)(A)Magazine Flooding Vv, 100 Mm , Remote Control Valvesmake; M/S Rotorkremote Control Valves Motorised Actuator353 - Replace Defective Motorised Actuators Of Remote Control Valves As Per List Placed At Appendix H. Firm To Quote For Supply And Installation Of Newmotorised Actuators As Per Following Scope Of Work: -(A) Removal Of Old Actuators, Removal Of Old Cabling From Valve Actuator To Local Control Panel, Fitment Of New Motorised Actuator, Renewal Of Associated Joints, Replacement Of All Associated Fasteners, Renewal Of Cabling From Local Control Panel To Valve Actuator.,Operation Of Remote Control Valves To Be Proved Manually, From Local Control Panel And From Ipms. , Remote Control Valves Mechanical Valve354 - Replace Following Remote Control Valves As Per Sow 2:-(A) 125 Mm Globe Valve - 04 Nos, 125 Mm Sluice Valve -01, 150 Mm Globe Valve -02,150 Mm Sdnr Valve-05, 200 Mm Gate Valve - 05, 200 Mm Sdnr-07, 40 Mm Globe Valve-01,50 Mm Ball Valve-02, 50 Mm Glove Valve-02, 50 Mm Sdnr Valve-01,65 Mm Globe Valve-01,80 Mm Ball Valve-02 , Fire Hydrants355 - Replace Fire Hydrants. Firmto Quote For Supply Of Spares. Location Of Hydrants As Per Appendix G. Scope Of Work Includes:-(A) Removal Of Old Hydrants, Replacement Of All Joints For Fitment,Replacement Of All Fasteners,Fitment Of New Hydrants, Greasing Of Valve Operating Wheeltrials To Be Taken Post Fitment In Presence Of Ship Staff. Ensure Nil Leakage From Hydrant. , Prewetting System356 - Thorough Survey The System . Work Involves (A) Remove Pipe Lines For Examination , Prewetting System357 - (B) All Valves To Opened, Overhaul And Refitted.Renew Valves If Damaged , Prewetting System358 - (C) Nozzles Fitted On Exposed Deck Deteriorated. To Be Renewed. Mat Brass (I) Type A - Qty 20 (Dia 20Mm Length 7 Cm) (Ii) Type B - Qty 50 (Dia 20Mm Length 7 Cm) (Iii) Type C - Qty 20 (Dia 20Mm Length 7 Cm) (Iv) Type D - Qty 20 (Dia 20Mm Length 7 Cm) , Prewetting System359 - (D) Manufacturing And Fitment Of Rubber Caps For Nozzles As Per Sample , Prewetting System360 - (E) Prove Normal Working Of The System To Ship Staff. , System Valvesprewetting System 361 - (N)Prewetting System (Scattered)Replace Following Underwater Valves As Per Ser Sow 2 (I)Sd Globe Vv, 65 Mm , System Valvesprewetting System 362 - (Iii)Sd Globe Vv, 40 Mm , System Valvesprewetting System 363 - (Iv)Sd Globe Vv, 25 Mm , System Valvesprewetting System 364 - (V) A Type Nozzle , System Valvesprewetting System 365 - (Vi)B Type Nozzle , System Valvesprewetting System 366 - (Vii) K Type Nozzle , System Valvesprewetting System 367 - (N)Prewetting System (Scattered)Overhaul Following Valves As Per Ser Sow 1(I)Sd Globe Vv, 65 Mm , System Valvesprewetting System 368 - (Ii) Sd Globe Vv, 50 Mm , System Valvesprewetting System 369 - (Iii)Sd Globe Vv, 40 Mm , System Valvesprewetting System 370 - (Iv)Sd Globe Vv, 25 Mm , System Valvesprewetting System 371 - (V) A Type Nozzle , System Valvesprewetting System 372 - (Vi)B Type Nozzle , System Valvesprewetting System 373 - (Vii) K Type Nozzle , System Pipesfire Main System374 - (C)Fire Main System. Lagging To Be Removed And Relagging To Be Done Prior Fitment. Mat - Asbestos Cloth, Approx Area - , System Pipesac Chilled Water System375 - (E)A/C Chilled Water Systemlagging To Be Removed And Relagging To Be Done Prior Fitment. Mat - Elastomeric Trinitrile Rubber, Approx Area - , System Pipesfresh Water System 376 - (L) Fresh Water System. Lagging To Be Removed And Relagging To Be Done Prior Fitment. Mat - Elastomeric Trinitrile Rubber, Approx Area - , System Pipesfire Main System377 - (C)Fire Main System. Lagging To Be Removed And Relagging To Be Done Prior Fitment. Mat - Asbestos Cloth, Approx Area - , System Pipesac Chilled Water System378 - (E)A/C Chilled Water Systemlagging To Be Removed And Relagging To Be Done Prior Fitment. Mat - Elastomeric Trinitrile Rubber, Approx Area - , System Pipesfresh Water System 379 - (L) Fresh Water Systemlagging To Be Removed And Relagging To Be Done Prior Fitment. Mat - Elastomeric Trinitrile Rubber, Approx Area - , Co2 Sysytem380 - (D) Remove And Clemical Clean Following Pipes As Per Ser Sow 3:-(I) Dia - 25 Mm, Mat - Ms, 200 Mtr(Ii)Dia - 32 Mm, Mat - Ms, 40 Mtr(Iii) Dia - 65 Mm, Mat - Ms, 20Mtr(Iv)Dia - 80 Mm, Mat - Ms, 60Mtr , Co2 Sysytem381 - (D) Replace Following Pipes As Per Ser Sow 4:- ( Pipe Contractor Supply ) (I) Dia - 25 Mm, Length - 50 Mtr, Mat - Ms(Ii)Dia - 32 Mm, Length - 10 Mtr, Mat - Ms(Iii) Dia - 65 Mm, Length - 5 Mtr, Mat - Ms(Iv)Dia - 80 Mm, Length - 15 Mtr, Mat - Ms(V) Dia - 8 Mm, Length - 180 Mtr, Mat - Ss(Vi)Dia - 8 Mm, Length - 50 Mtr, Mat - Cu , Deep Sea Sealdeep Sea Seal Port &Stbd 382 - Renew Air Supply Pipe Lines. Size: - 10 Mm, Length: - 25 M , Strainers383 - Replace Following Strainers As Per Sample:-(A) Salvage System -20 Nos, Sea Chest Strainers-12 Nos, Ballast System- 19 Nos Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 06-01-2022 14-01-2022
2 13-01-2022 18-01-2022
3 28-12-2021 11-01-2022

Key Value

Document Fees
Refer document
EMD
INR 1000000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail