}

Bids Are Invited For Rf Ablation Equipment For Varicose Vein Treatment ( Q3 ) ( ) Total Quantity : 1-Ndovenous Radiofrequency Generator: The Rf Generator Should Deliver Radiofrequency Energy To The Catheter, Providing Consistent An, ahmedabad-Gujarat

Government Departments has published Bids Are Invited For Rf Ablation Equipment For Varicose Vein Treatment ( Q3 ) ( ) Total Quantity : 1-Ndovenous Radiofrequency Generator: The Rf Generator Should Deliver Radiofrequency Energy To The Catheter, Providing Consistent An. Submission Date for this Tender is 24-12-2021. Medical Equipment Tenders in ahmedabad Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

30251474
Corrigendum : Bids Are Invited For Rf Ablation Equipment For Varicose Vein Treatment ( Q3 ) ( ) Total Quantity : 1-Ndovenous Radiofrequency Generator: The Rf Generator Should Deliver Radiofrequency Energy To The Catheter, Providing Consistent An
Indian
Gujarat
Ahmedabad
24-12-2021

Tender Details

Bids Are Invited For Rf Ablation Equipment For Varicose Vein Treatment ( Q3 ) ( ) Total Quantity : 1-Ndovenous Radiofrequency Generator: The Rf Generator Should Deliver Radiofrequency Energy To The Catheter, Providing Consistent And Controlled Treatment Of Varicose Veins. 1 Rf Generator Should Be Compatible With 7F Catheter With In-Built Thermocouple And Non-Sticky Outer Coating 2 Rf Generator Should Operate On Set Temperature Of 105 -120 Degrees With Maximum Power Of 40W With Average Delivery Of 67J / Cm Per Treatment Cycle 3 Catheter Compatible To Rf Generator Should Have A Heating Element Length Of 7Cm, Providing Insertable Length Of 60 Cm / 100 Cm 4 The Heating Element Diameter Should Be 2.3 Mm With Guidewire Compatibility Of 0.025” 5 The Rf Generator Should Be Compatible With Bipolar Catheters And Should Have A Hand Switch For Energy Delivery 6 Rf Generator Should Use A Segmental Ablation Technique For Treatment Purpose, Hence There Should Not Be Any Energy Delivery While Repositioning Of Catheter 7 Rf Generator Procedure Should Offer Convenient Usage Without The Need Of Measuring Pull Back Time, Should Have A Auto-Set For 20 Seconds, Should Deliver 105 - 115 Degrees Vein Wall Contact Temperature Without Causing Tissue Impedance And Interruptions 8 Should Offer Temperature Accuracy Of ± 5 Degrees With Rms Output Voltage Of 110V 9 Rf Generator Should Meets Iec 60601 Safety Standards For Electrical Medical Device . 10 Rf Generator Should Have A Usfda Approval For Varicose Vein Treatment 11 Rf Generator Should Give A Continuous Feedback On : ▪ Real Time Temperature Feedback Control ▪ Display Of Power Delivered To Achieve Set Temperature ▪ Alert Tones Indicate Functions Of The Device 12 Rf Generator Should Have A Built With An Intuitive User Interface On The Following Parameters: ▪ Large Lcd Touch Screen For Simplified User Interaction ▪ Simple, Quick Viewing Of Treatment Parameters ▪ Color Gauges Indicate Treatment Parameter Range 13 Rf Generator Should Have A Ergonomic Console On The Below Parameters: ▪ Reduced Weight And Volume For Easy Portability ▪ Built-In Handles For Easy Lifting And Carrying ▪ Convenient Holder For Power Cord 14 Radiofrequency Catheter Should Have : 14.1 The Catheter Should Have A Thermocouple That Monitors Treatment Temperature And Provides Feedback To Control Energy Deliver 14.2 The Catheter Should Be 7F And 7Cm-Long Heating Element That Heats Segments Of The Vein Sequentially Along The Leg 14.3 There Should Be A Non-Stick Outer Surface In The Catheter That Keeps The Heating Element Clean During Multiple Treatments 14.4 The Catheter Should Accommodate A 0.025” Guidewire, If Needed, For Placement Within The Vessel 14.5 The Catheter Should Be Available In 60Cm And 100Cm Lengths, And A 7F , 11Cm Sheath Should Be Used 14.6 ‘Segmental Ablation’ Technique Should Allow Complete Ablation Of Vein Without Leaving Any Segment 14.7 Patient Connection Should Be Of Bipolar Catheter And There Should Be No Tissue Impedance Or Interruptions 14.8 Catheters Should Have Hand Switch For Better Control And 7 Cm Should Be Treated In 20 Seconds 14.9 No Saline Drip Or Functional Test Is To Be Carried Out During Procedure Sn Boq Qty Uom 1 Rf Ablation Equipment With All Accessories: As Per Technical Specification

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-12-2021 24-12-2021

Key Value

Document Fees
Refer document
EMD
INR 24300.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail