Bids Are Invited For Potable Analyser Kit ( D.O, Ph, Temp.Cond ) - Measuring Range Ph: – 2.0 … 20.0 Ph– 2.00 … 20.00 P– 2.000 … 20.000 Ph, Mv:± 2000; ± 1250.0Accuracy ( ± 1 Digit ) ± 0.004 Ph , ±0.1 Mvtemperature – 5.0 … 105.0 Conductivity, Tds, Sa, Srinagar-Jammu And Kashmir

Government Departments has published Bids Are Invited For Potable Analyser Kit ( D.O, Ph, Temp.Cond ) - Measuring Range Ph: – 2.0 … 20.0 Ph– 2.00 … 20.00 P– 2.000 … 20.000 Ph, Mv:± 2000; ± 1250.0Accuracy ( ± 1 Digit ) ± 0.004 Ph , ±0.1 Mvtemperature – 5.0 … 105.0 Conductivity, Tds, Sa. Submission Date for this Tender is 20-12-2021. Coats and Jackets Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30250292
Bids Are Invited For Potable Analyser Kit ( D.O, Ph, Temp.Cond ) - Measuring Range Ph: – 2.0 … 20.0 Ph– 2.00 … 20.00 P– 2.000 … 20.000 Ph, Mv:± 2000; ± 1250.0Accuracy ( ± 1 Digit ) ± 0.004 Ph , ±0.1 Mvtemperature – 5.0 … 105.0 Conductivity, Tds, Sa
Open Tender
Indian
Jammu And Kashmir
Srinagar
20-12-2021

Tender Details

Bids Are Invited For Potable Analyser Kit ( D.O, Ph, Temp.Cond ) - Measuring Range Ph: – 2.0 … 20.0 Ph– 2.00 … 20.00 P– 2.000 … 20.000 Ph, Mv:± 2000; ± 1250.0Accuracy ( ± 1 Digit ) ± 0.004 Ph , ±0.1 Mvtemperature – 5.0 … 105.0 Conductivity, Tds, Salinity & Resistivity Measuring Range Conductivity 0.0 … 2000 Ms / Cm, Additionally 0.00 … 19.99 Μs / Cm, K = 0.1 Cm–1, Tds: 0 … 1999 Mg / L, 0 … 199.9 G / L Salinity: 0.070.0 ( Acc. Iot ) , Sp. Resistivity: 0.00 … 20 Mo Cmcell Constants Automaticccuracy ( ± 1 Digit ) ± 0.5 % Dissolved Oxygen Measurement Conc. Measuring Range 0.00 To 20.00 Mg / L Saturation Measuring Range 0.0 To 200.0 % Partial Press. Measuring Range 0.0 To 400 Hpa Accuracy ± 0.5 % Temperature 0 To 50 °C , Turbidity Meter ( Potable ) - The Instrument Should Be A Micro Processor Based, Laboratory And Portable, Suitable For Measurement Even For Coloured Samples And With The Following Specification.Display2 Line 16 Characters Lcd Detectorphotodiode Ranges0-1000 Ntu In Four Ranges ( Automatic ) A ) 0-1Ntu B ) 0-10 Ntu C ) 0-100 Ntu D ) 0-1000 Ntu Accuracy±1.5% Of Fsd In 0-500 Ntu ±2% Of Fsd In 500-1000 Ntu Repeatability±1% Of Fs ( Std. ) Calibration Formazine Standard Solution Data Storagecalibration And Data Storage In Memory Power Requirement230 V Ac ± 10%, 50 Hz. Standard Accessoriesall Necessary Accessories To Make Instrument Functional Such As Epoxy – Coated Steel Case, Instruction Manual, Power Cable And Plug, Dust Cover, Light Shield, Test Tubes ( 25Mm Diameter ) [ 04 Nos. ] And Stand.Warrantycomprehensivewarranty / Guaranteeshouldbevalidfor Three Years. , Specific Ion Meter - 1.0Descriptionshould Be Microprocessor Controlled With Rs 232-C Output Facility. He Front Panel Should Be Splash Proof, Corrosion Resistant And Impact Resistant. 2.0Modeph, Concentration, Temperature, Mv 3.0Ph Range0.00 To 14Resolution0.001Accuracy± 0.005Slope80 To 120 %Calibrationauto Three To Five Points Calibration ( Automatic Buffer Recognition ) Temperature Compensationautomatic Throughout The Range4.0Concentration Range0.001 To 19900 Ppb / Ppm Resolutionat Least One Significant Digitaccuracy± 0.5%5.0Temperature Range-10° To 130°C Resolution± 0.1°C6.0Millivolt Range± 1500Resolution0.1Mvaccuracy± 2.0 Mv Or ± 0.05%7.0Timerdate And Time Can Be Called Up And Recorded Any Time 8.0Displaygraphic Lcd Display, Lcd Dot Matrix 128 / 64 Dps Panel With Backlight And Feather Touch Keys.9.0Readyindication Of Stable Value Reached.10.0Blankoptional Entry Of Blank Or Back Ground Solution, Correction11.0Power9voltslineadaptororcompatibleadaptorfor ( 230±10 ) Volts / 50 Hz Ac12.0Requirementincaseofpowerfailure, Securestorageofallcalibration And Programme Data. 13.0Inputatleast1ormorebnc / Deininput.1Pintipf-Type, Banana Type, Rs -232C, Printer Connection Facility14.0Drift< 50 Micro Volts / °C15.0Electrodecomplete Electrodes Sets For Reference Ammonia, Fluoride. Nitrate, &Phalongwith Instruction / Application Sheetstandardaccessories Including Electrolytes, Standard Solutions ( Ppm ) Etc.16.0Othersthe Instrument Should Be Complete With Connecting Cable, Adaptorfor230±10Voltsac50hzpowersupply, Dustcover, Electrodestand ( Adjustable ) , Perationand Maintenance Manual Along With The Accessories With Spares And Consumables For Three Years Of Trouble Free Operation Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 10 Lakhs /-