}

Bids Are Invited For Pile20.2.3 - Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding Th, Fatwah-Bihar

Government Departments has published Bids Are Invited For Pile20.2.3 - Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding Th. Submission Date for this Tender is 20-12-2021. Coats and Jackets Tenders in Fatwah Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

30223853
Bids Are Invited For Pile20.2.3 - Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding Th
Open Tender
Indian
Bihar
Fatwah
20-12-2021

Tender Details

Bids Are Invited For Pile20.2.3 - Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement Butincluding The Cost Of Boring, With Bentonite Solution Andtemporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. All Complete, Including Removal Of Excavatedearth With All Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Upto Bottom Of Pile Cap ) .450Mm Dia Piles ( Inclusive Of Carriage ) , Pcc4.1.5 - Providing And Laying In Position Cement Concrete Of Specified Gradeexcluding The Cost Of Centering And Shuttering - All Work Up To Plinthlevel : 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Inclusive Of Carriage ) , Rcc - Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportion As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. ( Inclusive Of Carriage ) , Brick Work - Brick Work With Bricks Of Class Designation 100A In Foundations And Plinthin :Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) ( Inclusive Of Carriage ) , Sand Filing - Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. ( Inclusive Of Carriage ) With Lead Upto 3 Km , Shuttering - Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Reinforcement Steel - Steel Reinforcement For R.C.C. Work Ready To Use Cut And Bend Rebars Of Approved Make From Factory / Workshop To Construction Site Including Placing In Position And Binding All Complete Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Plinth Protection - Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , Door & Window - Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Glass - Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) , Door Closer - Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. , Door - Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. 30 Mm Thick Including Stainless Steel Butt Hinges Wirhnecessary Screws , Door Stopper - Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. Single Rubber Stopper , Solling - Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes, Royalty All Complete As Perbuilding Specification And Direction Of E / L, , Tile 111.41A.3.1 - Providing And Laying Vitrified Tiles In Floor In Different Sizes { Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Jointing With Grey Cement Slurry @3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc. The Tiles Must Be Cut With The Zero Chipping Diamond Cutter Only.Laying Of Tiles Will Be Done With The Notch Trowel, Plier, Wedge, Clips Of Required Thickness, Leveling System And Rubber Mallet For Placing The Tiles Gently And Easily.Glazed Vitrified Tiles Matt / Antiskid Finish Of Size Size Of Tile 600X600 Mm , Tile 2 - Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , Tile 3 - Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Granite - Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge : Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elite Brown, Cat Eye Or Equivalent. , False Ceiling - Providing And Fixing Mineral Fibre False Ceiling Tiles At All Heights Of Size 595X595mm Of Approved Texture, Design And Pattern. The Tiles Should Have Humidity Resistance ( Rh ) Of 99%, Light Reflectance ? 85%, Thermal Conductivity K = 0.052 - 0.057 W / M K, Fire Performance As Per ( Bs 476 Pt - 6 &7 ) In True Horizontal Level Suspended On Interlocking T-Grid Of Hot Dipped All Round Galvanized Iron Section Of 0.33 Mm Thick ( Galvanized @120 Gsm ) Comprising Of Main T Runners Of 15X32 Mm Of Length 3000 Mm, Cross T Of Size 15X32mm Of Length 1200 Mm And Secondary Intermediate Cross T Of Size 15X32 Mm Of Length 600 Mm To Form Grid Module Of Size 600X600 Mm Suspended From Ceiling Using Galvanized Mild Steel Itemgalvanised @80Gsm ) 50 Mm Long 8Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Diameter Fully Threaded Hanger Rod Up To 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm, Spaced At 1200 Mm Centre To Centre Along Main ‘T’. The System Should Rest On Periphery Walls / Partitions With The Help Of Gi Perimeter Wall Angle Of Size24x24x3000 Mm Made Of 0.40 Mm Thick Sheet, To Be Fixed To The Wall With Help Of Plastic Rawl Plug At 450 Mm Centre To Centre & 40 Mm Long Dry Wall S.S. Screws. The Exposed Bottom Portion Of All T-Sections Used In False Ceiling Support System Shall Be Pre-Painted With Polyester Baked Paint, For All Heights. The Work Shall Be Carried Out As Per Specifications, Drawings And As Per Directions Of The Engineer-In-Charge. With 16 Mm Thick Beveled Tegular Mineral Fibre AntiMicrobial False Ceiling Tile Confirming To Iso 5 ( Class 100 ) Specifications , Pre-Fabsteel - Designing, Providing, Installing And Fixing Factory Finished Custom Designed Cold Form Light Gauge Steel Framed Super Structure Comprising Of Steel Wall Panel, Trusses, Purlins Etc Manufactured Out Of Minimum 0.75 Mm Thick Steel Sheet As Per Design Requirements. The Steel Sheet Shall Be Galvanized ( Az-150Gms Aluminium Zinc Alloy Coated Steel Having Minimum Yield Strength 300-550 Mpa ) Conforming To Aisi Specifications And Ibc 2009 For Cold Formed Steel Framing And Construction And Also As Per Is: 875-1987, Iso 800-1984 And Is:801- 1975.The Frames Shall Be Fixed To Rcc Slab Or Tie Beam Over Neoprene Rubber Using Self Expanding Carbon Steel Anchor Bolt Of Dia As Per Approved Drawings. Design Subject To Minimum 12Mm Diameter And 121Mm Length Conforming To Aisi 304 And 316 At 500Mm C / C With Minimum Embedment Of 100Mm In Rcc ( Rcc To Be Paid Separately ) And Located Not More Than 300Mm From Corners Or Termination Of Bottom Tracks Complete In All Respects. The Item Also Includes The Submission Of Stability Reports Dulyexamined And Issued By Any Nit / Iit. The Rate Includes The Concept Design, Detailed Design, Fabrication Of Sections, Transportation, Installation And All Required Fixing Arrangement At Site As Described Above. , Pre-Fabwall - Providing And Fixing Of External Wall System On Light Gauge Steel Frame Work With Outer Face Cement Boards As Per Standard Sizes Fixed With Self- Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make. A Groove Of 2 Mm To 3Mm Shall Be Maintained And Grooves Shall Be Sealed With Silicon Based Sealant. The Board Shall Be Fixed In A Staggered Pattern. Internal Face 12.5 Mm Thick Gypsum Plaster Board Fixed On Cement Board As Per Standard Sizes Fixed With Self Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make, Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish. ( Cost Of Frame Work To Be Paid For Separately ) Outer Face: Outer Face Having 6Mm Thick Fiber Cement Board Fixed On 9Mm Thick Fiber Cement Board, Type A, As Per Is:14862:2000 ( High Pressure Steam Cured ) Inner Face :- 12.5 Mm Thick Gypsum Plaster Board Conforming To Is 2095:2011 Fixed On 8 Mm Thick Fibre Cement Board Confirming To Is:14862:2000 Of Type B ( High Pressure Steam Cured ) , Pre-Fabin. Wall - Providing And Fixing Internal Wall Panels On Light Gauge Steel Frame Work With 12.5Mm Thick Gypsum Plaster Board Conforming Is 2095:2011 Fixed On Cement Board As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make, Screws Shall Be Of Counter Sunk Rib Head Of 1.60Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm. Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish. ( Cost Of Frame Work To Be Paid For Separately , Roof Sheet - Supply & Installation Of Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches While Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55Mm ) With Epdm Seal Or With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Ridge Plain - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumen Washers Complete : Ridges Plain ( 500 - 600Mm ) . , Gutter Drain - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumen Washers Complete : Gutter , Flashing - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + 5% Total Coated Thickness ( Tct ) , Zinc Coating 120Gsm As Per Is: 277 In 240Mpasteel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Topcoat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumenwashers Complete :Flashings / Aprons. ( Upto 600 Mm ) , Under Deck Insulation - Providing And Fixing Thermal Insulation Of Ceiling ( Under Deck Insulation ) With Resin Bonded Rockwool Conforming To Is: 8183, Density 48 Kg / M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Ceiling With Metallic Cleats ( 50X50x3 Mm ) @ 60 Cm And Wire Mesh Of 12.5Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Resin Bonded Rock Wool - Providing And Fixing Thermal Insulation With Resin Bonded Rock Wool Conforming To Is: 8183, Having Density 48 Kg / M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held And In Position By Criss Cossing Gi Wire Etc. Complete As Per Directions Of EngineerIn- Charge. , Putty - Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Distemper - Distempering With Dry Distemper Of Approved Brand And Manufacture ( Two Or More Coats ) And Of Required Shade On New Work , Over And Including Priming Coat Of Whiting To Give An Even Shade. , Ex. Paint - Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) , Oil Paint - Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work . , Steel - Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Excavation - Earth Work In Excavation Over Areas ( Exceeding 30 Cm In Depth. 1.5 M In Width As Well Es 10 Sqm On Plan ) Including Disposal Of Excavated Earth , Lead Upto 50 M And Lift Upto 1.5 M; Disposed Earth To Be Levelled And Neatly Dressed. , Paver Block - Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thickcompacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Phe 4 - Providing And Fixing Mirror Of Superior Glass ( Of Approved Quality ) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing: Rectangular Shape 453X357 Mm , Phe 5 - Providing And Fixing Toilet Paper Holder:C.P. Brass , Phe 6 - Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C.Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Fixtures Complete, Including Cutting And Making Good The Walls Andlevel White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlleddevice ( Handle Lever ) Conforming To Is : 7231, With All Fittings And Floors Wherever Required :White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440 Mm With Integral Type Foot Rests , Phe 7 - Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Phe 8 - Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In-Charge , Phe 11 - Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15Mm Nominal Bore , Phe 12 - Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Confirming To Is:893115Mm Nominal Bore , Phe 13 - Providing And Fixing C.P.Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is 8931 A ) 15 Mm Nominal Bore.15 Mm Nominal Bore , Phe 14 - Providing And Fixing Wash Bashin With C.I. Brackets, 15Mm Dia Cp Brass Singal Hole Basin Mixer Of Approved Quility And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required - White Vitreous China Surgeon Type Wash Basin Of Size660x460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps With Elbow Operated Levers , Phe 19 - Providing And Fixing Cp Brass Shower Rose With 15 Or 20 Mm Inlet100 Mm Diameter , Phe 20 - Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour.600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. , Phe 22 - Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. ( Internal Work ) 40 Mm Dia, Nominal Bore , Phe 23 - Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. ( Internal Work ) 50 Mm Dia, Nominal Bore , Phe 25 - P / F M.S. Cap 100 Mm Dia , Phe 26 - Providing And Fixing, Upvcpipes 6 Kg / Cm2 ( Is: 4985 ) Including All Fittings ( Plain Or Door ) E.G. Bends, Junction, Offsets, Access Pieces, Jointing With Rubber Ring / Solvent Cement Joints Includingrequired Suports, Cutting Chase Or Holes In Walls And Floors And Making Good Where Required.75 Mm Dia Pipe , Phe 27 - Providing And Fixing, Upvcpipes 6 Kg / Cm2 ( Is: 4985 ) Including All Fittings ( Plain Or Door ) E.G. Bends, Junction, Offsets, Access Pieces, Jointing With Rubber Ring / Solvent Cement Joints Includingrequired Suports, Cutting Chase Or Holes In Walls And Floors And Making Good Where Required.110 Mm Dia Pipe , Phe 28 - Providing & Fixing On Wall Face Unplasticised -Rigid Pvc Rain Water Pipes Conforming To Is:13592 Tyape A Included Jointing With Seal Ring Conforning To Is:5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Socketed Pipes.110 Mm Diameter , Phe 29 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Coupler -110 Mm Diameter , Phe 30 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Bend -87.5 Deg -110 Mm Diameter , Phe 31 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Shoe -110Mm Shoe , Phe 32 - Providing & Fixing Unplasticised - Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50mm Hard Wood Plugs, Screwed With .M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm Dia , Phe 33 - Providing And Fixing Cpvc Pipes Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 Mt Spacing. This Includes Jionting Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. 20 Mm Nominal Outer Dia Pipes , Phe 34 - Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 25Mm Dia, Nominal Bore , Phe 35 - Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 32 Mm Dia, Nominal Bore , Phe 36 - Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Pn 1.6 ) 40 Nominal Bore , Phe 37 - Providing And Fixing Brass Stop Cock Of Approved Quality15mm Nominal Bore , Ex. Phe 6 - Providing 250Mm Wide Brick Drain In Cement Mortar ( 1:6 ) With Av. 150Mm. Clear Depth And 250Mm Apron Including Cost Of E / W. Involved With 75Mm Cement Concrete ( 1:4:8 ) Over One Brick Designation 100-A Flat Soling In Proper Grade And Slope At The Base.The Drain Duly.Plastered In Cm. ( 1:3 ) With Punning Over Exposed Surface All Complete As Per Buildingspecification And Direction Of E / L, , Ex. Phe 7 - Excavating Trenches Of Required Width For Pipes, Cables Etc. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottom Depth Upto 1.5 M Including Getting Out The Excavated Soil ( Hard Or Soft ) And Then Returning The Soil As Required In Layers Not Exceeding 20 Cms In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. [ Hard / Dense Soil ] Pipes, Cables Etc.Exceeding 80Mm Dia.But Not Exceeding 300Mm Dia. , Ex. Phe 9 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 250 Mm Dia Rcc Pipe , Ex. Phe 10 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 300 Mm Dia Rcc Pipe , Ex. Phe 15 - Constructing Masonry Chamber 60X60x75 Cm, Inside With 75 Class Designation Brick Work In Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Channel Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement: 2 Coarse Sand: 4 Graded Stone Sggregate 20 Mm Nominal Size ) Necessary Excavation Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With F.P.S. Bricks , Fire Extinguisher-2 - Providing And Fixing Abc Powder Type Fire Extinguishers Consisting Of Welded M.S. Cylindericalbody, Squeeze Lever Discharge Valve Fitted With Pressure Indicating Guage Internal Discharge Tube 30 Cms Long High Pressure Discharge Hose, Discharge Nozzle, Suspension Bracket Conforming To Is:15683 Finished Externally With Red Enamel Paint And Fixed To Wall With Brackets Complete With Internal Charge.Capacity 4.5 Kg. , Electrical 2 - Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Electrical 3 - Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. Group C , Wiring Frls Pvc Insulated Copper Conductor 1 - 2 X 2.5 Sq. Mm. + 1 X 2.5 Sq. Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 2 - 2 X 4 Sq.Mm. + 1 X 4 Sq.Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 3 - 2 X 6 Sq.Mm. + 1 X 6 Sq.Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 4 - 4 X 16 Sq. Mm + 2 X 16 Sq. Mm Earth Wire , S / F, Gi Box Along With Modular Base & Cover Plate 1 - 1 Or 2 Module ( 75Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 2 - 3 Module ( 100Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 3 - 4 Module ( 125Mmx75mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 4 - 6 Module ( 200Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 5 - 12 Module ( 200Mmx150mm ) , S / F Modular Switch / Socket On The Existing Modular Plate 6 - 5 / 6 Amps Switch , S / F Modular Switch / Socket On The Existing Modular Plate 7 - 15 / 16 Amp Switch , S / F Modular Switch / Socket On The Existing Modular Plate 8 - 3 Pin 5 / 6 Amp Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 9 - 6 Pin 15 / 16 Amp Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 10 - Bell Push , Electrical 7 - Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Electrical 8 - Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In R.C.C. Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete As Required. , Electrical 10 - Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. , Electrical 13 - Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way , Double Door , 40 A, Rccb - Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40A Mcb - Supplying And Fixing 40 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Tp Mcb , Single Pole Mcb - Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Earthing 1 - Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. , Earthing 2 - Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. , Earthing 3 - Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Fiting & Fixtures 1 - Supply And Installation Of Regular / Standard Model A.C. Ceiling Fan Of 1400 Mm Sweep Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Fr Pvc Insulated Copper Conductor Etc As Required. , Fiting & Fixtures 2 - Supplying And Fixing Single Wall Mounted 18 / 22 Watt Led Type Batten Fitting Complete With Electronic Driver And Led Tube Etc Directly On Wall / Ceiling Includingconnections With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor And Earthing The Body Etc. As Required. , Fiting & Fixtures 3 - Supply Installation And Comissioning Ofintegrated Batten Made ( 2Ft ) Of Ultra Slim Co-Extruded Polycarbonate Channel With Housing Part In White Finish & Diffuser Part In Reeded Opal Finish.White Finish Abs End Caps With Decorative Circular Coloured Polycarbonate Cap Snap Fitted On The End Cap To Enhance The Aesthetic Of The Fixture. These End Caps Are Snap-Fitted To The Fixture.High Efficiency Long Life Led With Lumen Efficacy Of 130 Lm / W With Viewing Angle Of 120º.Powered By An Integral Isolated Low Thd Electronic Led Driver ( Smps Based Constant Current Supply ) With Output Short Circuit Protection, Surge Protection.Can Be Fixed Directly Into The Wall / Ceiling By Means Of Mounting Ss Clips Provided With The Fixture. Ip 20, Lumen Output Of 950 Lumens With System Efficacy Of > 105Lm / W .Cri >80, Color Temperature 6500K, Thd <20% And Pf>0.95, Ip20 . Life Class Of 35, 000 Hrs @ L70, Operating Temperature:-10 To +45 Deg.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 Hz;Internal Surge Protection:3 Kv; Protection Including 3 Core 1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed Copper Conductor Cable And Earthing Etc. Up To Suitable Point Complete As Required. : Reverse Polarity, Open & Short Circuit. Driver Safety Requirement Standards :Is 15885-2-13, Test Report To Be Submitted; Photo Biological Safety Norms: Is 16108, Test Certificate To Be Submitted; Certification: Lm 79 For Luminaire Lm 80 For Led Source. Cat Ref - Havells :Lumilinebs9wled840spcwh Or Approved Equivalent. , Fiting & Fixtures 5 - Supplying And Fixing Recess Mounted 18 Watt Led Vertical Downlighter Complete With All Accessories And Replaceable Electronic Driver, Directly On False Ceilingincluding Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Fiting & Fixtures 7 - Supply Installation And Comissioning Of 28W 2X2 Panel Recess Mounting Luminaire With High Performance Leds, Suitable For Mounting With Armstrong / Grid Ceiling.Crca Powder Coated White After Phosphochromate Treatment.High Efficiency Long Life Led Package In Integral Module With Lumen Efficacy Of >100 Lm / W And Viewing Angle Of 120° To Ensure Better Uniformity.Powered By An Independent Isolated, Selv Output Electronic Led Driver ( Smps Based Constant Current Supply ) With Output Short-Circuit Protection, Surge Protection & Other Reliability Test. Lumen Output Of 3450 Lumens.Cri >80, Color Temperature 5700K, Thd <10% And Pf >0.95, Ip20, Ik03.Life Class Of 50, 000 Hrs @ L70, Operating Temperature:-10 To +45 Deg.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 Hz;Internal Surge Protection:3 Kv; Protection Including 3 Core 1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed Copper Conductor Cable And Earthing Etc. Up To Suitable Point Complete As Required. : Reverse Polarity, Open & Short Circuit. Driver Safety Requirement Standards :Is 15885-2-13, Test Report To Be Submitted; Photo Biological Safety Norms: Is 16108, Test Certificate To Be Submitted; Certification: Lm 79 For Luminaire Lm 80 For Led Source.Cat Ref - Havells :Venusneohe2x2plr128wled857 Or Approved Equivalent. , Signage 4 - Providing And Fixing Of Signages Modular Curved Frame Technology Of Various Widths And Lengths To Fometre Suggested Usages Made Of Aluminium Extruded Sections. Duly Anodised All Signages Shall Be Provided With 0.6-0.8Mm Polycarbonate Protecting Film Over The Prints Of Appropriate Size .All Complete As Per Direction By Engineer In Charge , Wall Projected 250X210mm, Both Sides , Signage 5 - Providing And Fixing Of Signages Modular Curved Frame Technology Of Various Widths And Lengths To Fometre Suggested Usages Made Of Aluminium Extruded Sections. Duly Anodised All Signages Shall Be Provided With 0.6-0.8Mm Polycarbonate Protecting Film Over The Prints Of Appropriate Size .All Complete As Per Direction By Engineer In Charge, Door Mounted, 300X80mm , Hospital Sheet Patient Bedtype - Iii With Mattress - Overall Sizes: ( L ) 1900 Mm X ( W ) 900 Mm X ( H ) 600 Mmdescription: Sheet Bed Should Be A Plain Bed Used In The Recovery Ward.Material Specifications: Under Structure Has A Higher Diameter Tubewhich Should Provide A Sturdy Understructure.Lying Surface Area Of Crcafinish Specifications: Head Board / Leg Board Should Be Made Of Frame Ms Erw Roundtube Of Sections Ø19, Ø25.4& Ø31.75Mm, Ofthickness1.6 Mmprovision For Mounting Of Iv Pole And Mosquito Net Pole Should Be Presentfinish Specifications: Powder Coating Should Be Bacteriostatic And Thermosetting Epoxy Polyester, Formulated To Fulfill The Requirements For Bacterial Protection.All Powder Coated Parts In Ral Whiteperformance Specifications: Maximum Patient Load Should Be 135 Kgthickness-Mattress: 3+Sandwitchconstruction: Round Corners - Yeshitlon Thickness ( Mm ) : 60Hitlondensity ( Gm / Dcm3 ) : 23Coir ( Both Side ) Thicknessmm: 20Density ( Gm / Dcm3 ) : 70, Drc ( % ) : 22Quilting - Combination / Layers:Pilled Foam – Quilting ( One Side ) Thicknessmm - 14Pilled Foam Density Gm / Dcm3 - 18Pu Foam / Epe Sheet Side Walling Thicknessmm - 3Total Mattress Thickness-Mm - 87Rexine ( Gsm ) : 150Note: * Finish Product Thickness Should Be Measure From Outer To Outer Surface. Tolerance +5 Mm , Medicinetrolleytype -I - Overall Size902mm ( L ) X532mm ( W ) X915mm ( H ) .Top Shelf Should Be Made Of Ss 304 Sheetof 1 Mm Thick. Supporting Legs Made Of Ss304 Tubesection 30.30 Mm Dia.Of 1.2 Mm Thick Provided To Suppoort The Entire Structure.Ss 304 Tube Provided At The Bottom For Placement Of Instument Being Used .Handle Made Up Of Ss 304 Tubeof Dia Dia 16 Mmand Thickness 1.2 Mm Provided To Handle Trolley .And Maneuver Accordingly. High Endurance Anti Static Plastic Injection Moulded Castors Of 125 Mm Dia.Ss Should Be Finished In Glossy Mirror Finish. Max Load Capacity Of 10 Kg / Shelf Udl , Round Stooltype -I - Overall Sizes Diagonal Legdia 538 Mmh470 Min-655Max.Ss 202 Made Sheet With Spin Section Of Thickness 1Mm & Should Be Non Corrosive. It Should Have A Diameter Of 305Mm, Seat Base Is Made Of Ms Ring And Rectangular Tube.En8 Screw Having Dia Of 22 Mm Should Be Used For Height Adjustment Of The Seat Base.The Hub Should Be Made Of Ms Erw Tube Having Dia Of 38Mm And Thickness 2 Mm.The Hub Should Be Welded With The Legs And It Should Accommodate And Cover The Lead Screw Mechanism.The Understructure Should Consist Of 4 Legs Made Up Ofms Erw Tube Of Diameter 25.4 Mm And 1.6Mm Thick. The Press Formed Pipe Leg Should Give A Round & Clean Look. All The Legs Should Be Provided With 4 Nos Of Nylon-6 Bush.All Metal Componentsshould Be Pre Treated With Zinc Phosphating In 9 Tank Process And Then Powder Coated With Anti Microbialepoxy Polyster Powder Coating . All Welding Should Be Co2 Argon Welding To Minimise Rusting On The Welding Areas.Safe Working Load Must Be 135Kg , Desk - Main Desk Should Be Of Dimesion : 1200W X 750D X 750H.The Table Top Should Bein White Cedar, Side Panelsin Black, While The Modestypanel Ina Combination Of Black & White Cedar. Filing Drawer With 18Mm Thick Plb Fronts And Top. Handles : Black Powder Coated Die Cast Aluminum Alloy Handles. Mobile Pedestal And Hdu Are Fitted With Central Lock. , Staff Chair Type I - Chair Of Over All Size: 58.0Cm ( W ) X 56.5Cm ( D ) X 87.5Cm ( H ) & 48.0Cm ( Sh ) Seat / Back Assembly: The Seat And Back Are Made From Chemically Treated And Seasoned Wood, Upholstered With Plywood, Black Leather-Cloth, And U-Foam.*Back Size: 46.0Cm ( W ) X 27.0Cm ( H ) .*Seat Size: 46.0Cm ( W ) X 40.0Cm ( D ) .Armrest Tube: The Armrest Tube Is Made Of M.S. E.R.W. Tube Dia. 2.54Cm. ( 1” ) X 16Bg Thick And Powder Coated.Armrest: The Armrest Is Gas-Assisted Injection Moulded From Black Polypropylene.Understructure Assembly: The Understructure Assembly Is A Cantilever Type Frame Made Of Dia. 2.54Cm. ( 1” ) X 14Bg. Thick M.S. E.R.W. Tube And Powder Coated. , Wheel Chair Type - I - ( L ) 790 X ( W ) 600 X ( H ) 870Mm.Foldable Frame Structure Should Be Made Of Section 22Diax1.2Mm A3 Carbon Steel With Chrome Finish. Cross Bar Should Be Made Of A3 Carbon Steel With Section 25.4 X 1.2Mm.Rear Wheel:24 Inch Solid Mag Wheels With Alloy In The Rim .Integrated Handrim Provide To Drive The Wheel Chair Of Section 16X1.2Mm A3 Carbon Steel With Chrome Finish.Front Wheel :8 Inch Hub Made Of Pa Polymer And Outer With Solid Rubber.Pu Molded Arm Rest & Base Should Be Made Of Abs For Better Arm Support .Leatherite Strap For Calf Rest & Leatherite Cushion For Seat.Adjustable Alluminimum Die Cast Foot Rest With Updown & Swivel Type Mechanism.Handles Should Be Made Of Moulded Rubber Grip To Push The Wheelchair.Hand Brakes Should Be Provided To Lock The Wheelchair At Desired Location.Foot Pressextended Base With Molded Plastic For Better Grip.Anti Rust Chrome Finsh. Safe Work Load Of100 Kg , Basin Stand Type I - Ht 850 Mm Ss Bowl Ms Tubular Frame Of Dia 25.4 X1.2 Mm Tube Work Mounted On Three 50 Dia.Non Rusting Castors All Without Brack. Ss Part Finished With Matt Polish , Kick Buckettype -I - Overa All Dimension Of The Bucket Should Be 517 Mm ( L ) X 517 Mm ( W ) X 210 Mm H.It Should Made Of 12.7 Mm Dia And 1.6 Mm Thick Ss 304 Ring. The Bowl Should Be Ss Made Of .8 Mm Thck . 3 Nos 50 Mm Diahigh Endurance Plasticinjection Moulded Castors Should Be Provided For The Movement. Mx Load Bearing Capacity Should Be 10 Kg. , Backpressurecompensated [ Bpc ] Oxygen Flowmeter - Supply, Installation, Testing And Commissioning Of Back Pressure Compensated [ Bpc ] Oxygen Flow Meter Body Should Be Made Of Brass Material Dully Chrome Plated And Graduated From 0-15 L / M On An Expanded Lower Scale Forprecision Setting At Low Flow And 5-15 L / M For General Use. The Humidifier Bottle Should Be Made Up Of Unbreakable Polycarbonate / Polysulphone Material And Autoclavable At 121 Degree Centigrade Temperature. It Should Be Ceand Iso 13485 Certified. , Oxygen Gas Outletfront Loadeddin / Bsstd - Gas Outlet Front Loaded Din / Bs Std:Supply, Installation, Testing And Commissioning Of Din / British Standard Gas Outlets Are For Use With Medical Gas System. The Gas Outlets Completely Complywith Htm2002 And C11 Standard Regulations And Pass The Test Of Leakage And Connector Stability. Medical Gas Outlet Shall Be Gas Specific For The Services Indicated And Accept Only Corresponding Din / British Standard Quickconnect Adapter. Specifically, Gas Specific Indexed To Eliminate Interchangeability Of Gas Services. The Gas Outlet Is Offered In Consoletype, Wall Type With Box And Hose Barb Type Gas System. It Should Be Ce And Iso 13485Certified. Din / Bis Std. Gas Outlets Feature And Benefits:* Comply With Htm2002 And C11 Standardregulations* Color Coded According To Iso32 Color*100% Pressure And Leak Tested* Full Range Of Mounting Options* Available In Wall Type With Box, Console Typeand Hose Barb Type* Gas Specific Adapters , Quickconnectadapter - Din / British Standard Quick Connect Oxygen Adapter ( Safety Probe ) , Tube - Oxygen H.P. Rubber Tube White Color, , Alarm - Supply, Installation, Testing And Commissioningof Area Pressure Alarm Panel Would Be Witdigital Display, Closed Circuit, Self-Monitoringtype. The Alarm Would Be Designed To Monitorthe Line Pressure In Piping Systems.It Should Be Ce And Iso 13485 Certified. Withfour Digit Notified No. Area Line Pressure Alarm-1 Gases , Isolation Valve 4 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 15Mm , Isolation Valve 5 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 12Mm , Pipeline 1 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 12 Mm ( Od ) X 0.7 Mm Thickness , Pipeline 2 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 15 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 3 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 22 Mm ( Od ) X 0.9 Mm Thickness Total Quantity : 1

Key Value

Document Fees
Refer document
EMD
INR 1228921.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail