Providing, Installation, Testing And Commissioning Of Electro-Mechanical Machinery And Equipments Alongwith Allied Works At Wss Kud Stage-2Nd- Providing, Installation, Testing And Commissioning Of 3000 Gph X 380 Meter Head Hc Pump Set With Suitabl, XEN Jal Shakti PHE Mechanical division Udhampu-Jammu And Kashmir

Government Departments has published Providing, Installation, Testing And Commissioning Of Electro-Mechanical Machinery And Equipments Alongwith Allied Works At Wss Kud Stage-2Nd- Providing, Installation, Testing And Commissioning Of 3000 Gph X 380 Meter Head Hc Pump Set With Suitabl. Submission Date for this Tender is 27-12-2021. Electromechanical Machinery Tenders in XEN Jal Shakti PHE Mechanical division Udhampu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30154032
Providing, Installation, Testing And Commissioning Of Electro-Mechanical Machinery And Equipments Alongwith Allied Works At Wss Kud Stage-2Nd- Providing, Installation, Testing And Commissioning Of 3000 Gph X 380 Meter Head Hc Pump Set With Suitabl
Open Tender
Indian
Jammu And Kashmir
Xen Jal Shakti Phe Mechanical Division Udhampu
27-12-2021

Tender Details

Providing, Installation, Testing And Commissioning Of Electro-Mechanical Machinery And Equipments Alongwith Allied Works At Wss Kud Stage-2Nd- Providing, Installation, Testing And Commissioning Of 3000 Gph X 380 Meter Head Hc Pump Set With Suitable Prime Mover Alongwith Allied Equipment And Accessories At Pumping Station Kud By Way Of Carriage Upto The Road Side Nearest To Pumping Station Kud, Unloading The Same From Vehicle And Manual Carriage To Pumping Station 700 Mtrs Approximately On Channels / Pipes Using Pick Axes, Crowbars, Ropes, Etc. And Stacking Inside Pump-Room. The Job Furtherincludes Earthwork In Bulk Excavation For Making Foundation Block Upto The Depth Of About 1.5 Meters So As To Form A Size Of 6’X3’X4’.Dumping Of Excavated Material Outside The Pump Room At A Distance Of About 50 Meters. Providing Andfabrication Of 06 Nos. Foundation Bolts Of Suitable Dia Meter One Meter Long By Threading Them At One End And Making Of Anchor To Other End. Laying Of Bed Concrete Of 1:4:8 Mix Using 20 Percent Aggregate, Laying Of Rcc Of 1:1.5:3 Mix Including Supply / Fixing Of Farm Work / Shuttering, Aggregates, Sand And Cement, Reinforcement 10Mm Steel Mesh Andall Rcc Work, Angle Iron For Supporting / Alignment Of Base-Frame Including Cutting, Bending, Placing In Position, Welding, Placing Of Foundation Bolts With Base Frame And Making Proper Alignment Of Base Frame Horizontally As Well As Longitudinally, Deploymentof Vibrator, Mixer, Welding Set, Shuttering, Tools And Tackles Etc. And Curing Complete. Job Further Includes Dragging Of Pump Motor Set From The Stacking Place And Then Placing Them On The Base Frame By Manual Labour And Other Tools And Tackles. Alignment And Leveling Of Pump Motor Set On The Base Frame By Using Laminated Sheet, Strips And Coupling Thereof. Providing / Laying Of 80Mm / 65Mm Dia Gi Suction And 80 / 65 Mm Dia Delivery Pipe Lines To The Pump Set By Providing / Cutting Of Required Dia Gi Pipes Approximately As Per Site Requirement In The Convenient Lengths And Also Interconnecting The Suction And Delivery Pipe Line With The Gsr And Rising Main Respectively With The Help Of Oxygen Acetylene Gas Cutting / Electrode Welding. The Cut Edges Shall Be Grinded With Grinder To Give Them A Smooth And Even Surface And Then Laying, Aligning, Welding Of Suction / Delivery Pipes In Continuous Fillet Weld By Using Superior Quality Electrodes Conforming To Isi Specification. The Weld Should Be Free From Blow Holes, Porosity, Cracks To Create Leak Proof Joints. Providing, Fabrication And Fitting Of 80 / 65 Mm Dia Ms Bends, 100Mm / 80Mm Dia Ms Flanges, Expanders, Reducers, Gaskets, Nuts, Bolts Etc. As Per Site Requirement, Providing / Fitting Of 80 / 65 Mm Dia Cast Steel Sluice Valve And Cast Steelnrv-01No. Each To The Delivery Pipe Line And 80 / 65 Mm Dia Foot Valve / Suction Valve Heavy Duty As Per Site Requirement To The Suction Pipe Line Confirming To Isi Make Including Nuts, Bolts, Gasket Flanges Etc. Job Further Includes Providing, Fabrication And Fitting Of 80 / 65 Mm Dia Gi Pipe Delivery Manifold Outside The Pump Room And Connecting With Delivery Pipe Line And Rising Main Using Oxygen Acetylene Gas Cutting And Welding. Job Also Includes Providing And Fitting Of Copper Cable Of Suitable Rating From Panel Upto Motor Approximately 40 Meters / As Per Site Requirement In Length With Proper Thimbling And Insulation Material. Job Also Involves Proper Earthing Of The Motor Of The Pump Set. Complete Job Includes Cost Of Material, Machinery, Hiring / Shifting / Transportation / Manual Carriage Charges Of Material, Machinery Tools And Tackles, Skilled And Unskilled Labour Charges Etc. 2 Design, Fabrication, Installation, Testing And Commissioning Of 110 Ampere Auto Starter Cum Protection Panel Cum Fault Analyzer At Pumping Station Kud Stage-2Nd. The Job Involves Fabrication Of Auto Starter With Power Contactor Mnx 110-2Nos. And Mnx 70 -1No. Of L&T / Isi Make. The System Should Be Provided With Solid State Fault Analyzer Cb4sa Or Other Equivalent System. The Complete System Should Be Enclosed In A Wall / Floor Mounted Ms Steel Enclosure Box Of Suitable Dimensions. The Enclosure Should Be Finished With Power Coated Painting From Inside As Well As From Outer Surface Of Approved Colour. Job Also Includes Mounting Of The Panel On The Wall / Floor Of The Pump Room Using Electrical Drilling Machine And Providing / Layingof Copper Cableof Reputed Make Conforming To Isi Specification From Board To Automation Cum Protection System Of Required Length , Thimbling And Socketing Each End Of The Conductor With Proper Rating Copper Thimbles Metering: The Enclosure Should Be Front Shutter Mounted With Key Locking System Having Glass Window, Digital Electronic Voltmeter, Ampere Meter Are To Be Provided Along With The Required Current Transformer And Selector Switches. The Internal Wiring Should Be Done With Flexible Pvc Lt Cable With Proper Thimbling At Each End. Features And Specifications: The System Should Trip The Motor On Power Failure And On Appearance Of Any Electrical Fault Mentioned Below Which May Otherwise Damage The Motor Field Coilsthus Providing Protection To The Motor. Low Voltage ( Below 350V ) High Voltage ( Above 450 V ) Single Phasing Reverse Phasing Un-Balanced Phasing. In Addition The System Shall Have: Separate Led Fault Indictors. Led Phase Indicators An Isolation / By Pass System A Siren / Audio Warning System Which Activates On Starter Failure Only. Complete Job Includes Cost Of Material, Machinery, Hiring / Shifting / Transportation / Manual Carriage Charges Of Material, Machinery, Tools And Tackles, Skilled And Unskilled Labour Charges Etc. 3 Providing, Carriage And Installation Of 3 Phase, Manually Operated, Copper Wound, Oil Cooled 100 Kva Voltage Stabilizer Complete With Insulating Oil ( T-Oil ) At Pumping Station Kud Stage-2Nd. The Job Involves Shifting The Unit And Accessories By Mechanical Transport Upto Road Side Near Pumping Station And Then Upto Pumping Station By Way Of Head Load, Tools & Tackles Through A Rough Terrain Of Approximately 850 Meters. Providing And Fitting Of 3.5 Core Aluminum Cable Of Suitable Rating, As Per Is Standards, From Pole To Voltage Stabilizer As Per Site Requirement In Length With Proper Thimbling And Insulation Material. Making All Incoming And Outgoing Connections. The Manual Operated Voltage Stabilizer Should Have Electrolytic Grade Copper Wound Coils Having Suitable Steps And Range I.E. It Should Work From 180V To 400+5% With Frequency Of 50+3 Hertz. Voltage Stabilizer Should Also Be Provided With, Change Over Switch And Mccb Of Suitable Rating. Testing The Voltage Stabilizer On No Load And Then On Full Load At Site. Complete Job Includes Cost Of Material, Machinery, Hiring / Shifting / Transportation / Manual Carriage Charges Of Material, Machinery, Tools And Tackles, Loading / Unloading With Crane, Skilled And Unskilled Labour Charges Etc.

Key Value

Document Fees
INR 200 /-
EMD
INR 40000.0 /-
Tender Value
Refer document