Estimate For Rain Water Harvestion In Ward ( 17-24 ) In Government Building Under Nagar Parishad Ramgarh Estimate For Rain Water Harvestion In Ward ( 17-24 ) In Government Building Under Nagar Parishad Ramgarh , Jungle Clerance In Borrow Area, Building Premises Flanks And Slopes On The Roads, Canals And Ambankment By Removing The Grass And The Jungle Bushes From The Top Including Weeding Out Shrubes Including Roots And Leveling Etc. Complete As Per Direction Of E L. ( Specification Revised In The Metting Of Regional Co- Ordinators Held On 11.01.84 In The Office Of T.E.C. , Earthwork In Excavation In Foundation Trenches In Ordinary Soil ( Vide Classification Of Soil Item-A ) And Disposal Of Excavated Earth As Obtained To A Distance Upto 50M Including All Lifts. Leveling Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E / I. , Extra For Earthwork In Hard Soil As Per Specification And Direction Of E / I. ( Vide Classification Of Soil Item B ) , Supplying Labour And Equipments For Digging Well ( Vide Classification Of Soil Items C ) With Chisel And Hammer Including Disposal Of Excavated Materials And Stacking The Spoils To Safe Distance At 50 Metre All Complete As Per Specification And Direction Of E / I. , Cost Of Driilling 200Mm X 16Mm X 150M Deep Bore Well In All Kind Of Soil Hydt Drilling Upto 50 M Depth Below G.L In Rural Area , Supplying Laying Boulder In Rock Toe, Heel Trenches Of The Dam As Per Design , Drawing Including The Cost Of Materials All Complete As Per Specification And Direction Of E / I , Supplying And Laying Good Quality Of Stone Metal Filter ( 20Mm To 63Mm Size ) In Rock Toe, Heel Trenches , Tee Drain As Per Design Drawing Including The Cost Of Materials All Complete As Per Specification And Direction Of E / I , Supplying And Laying Sand Filter Flanking In Horizontal Portion Of The Dam As Per Design And Drawing With Watering Compaction Including Cost Of Sand , Royalyty Etc, But. Excluding The Cost Of Carrige All Complete As Per Specification 0 , Providing P.C.C. M-100 With Nominal Mix Of ( 1:3:6 ) In Foundation With Approved Quality Of Stone Metal Grade-Iii ( 50 Mm To 25 Mm Size ) Clean Coarse Sand Of F.M. 2.5 To 3 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Striking, Curing, Taxes And Royalty All Complete As Per Building Specification And Direction Of Engineer-In-Charge. , Providing 75 A Designation Brickwork In Cm 1:6 In Foundation -Do-Do -Complete Job As Per Specification And Direction Of E / I , Providing 12 Mm Cement Plaster In Cement Mortar 1:6 With Clean Coarse Sand Of F.M. 1.5Including Screening, Curing With All Leads And Lifts Of Water, Scaffolding Taxes And Royalty All Complete As Per Building Specification And Direction Of E / I , Supplying Materials And Labours For Constructing Inspection Chamber Of Designation Class 75 B Bricks Size 750 Mm Deep, 600 X 450 Mm Internal Dimension Having 250 Mm Wall Thickness In Cement Mortar ( 1:6 ) Including 12 Mm Cement Plaster ( 1:4 ) With Punning On Inside And Cement Plaster ( 1:6 ) With 600 X 475 Mm G.I. Cover With Frame ( Weight Not Less Than 36 Kg. ) Along With Earthwork In Excavation And 80 Mm Thick P.C.C. ( 1:3:6 ) In Foundation And Refilling All Complete As Per Specification And Direction Of E / I. , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. All Complete As Per Specification And Direction Of E / I. 110 Mm Dia , Providing Rcc M20 With Nominal Mix Of 1:1.5:3 In Slab Do All Complete As Per Specification And Direction Of E / I. , Supply Of Upvc Casing Pipe 200 Mm X 3 M Length , Labour Charge For Lowering And Fitting Of Upvc Casing , Supplying Labours And Tools For Laying And Jointing U.P.V.C. Pipe In Trenches And Making Joints With U.P.V.C. Collar And Solvent Cement, Including Providing Night Guard, Barrier & Red Light To Safe Guard Against Accident, All Complete As Per Specification And Direction Of E / I. ( B ) 110 / 100 Mm Dia , Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion 110 Mm Coupler , Bend 110 Mm , Supplying Material And Construction Of Brick Masonry Drain 150 Mm Width And 150 Mm Depth With 250 Mm Apron On Both Side Over 50 Mm Thick Pcc 1:3:6 Over Brick Flat Soling And Sand Filling With Plaster Do All Complete Job As Per Specification And Direction Of Ei , Providing Tor Steel Reinforcement 0F 10 Mm Dia Do All Complete Job As Per Specification And Direction Of Ei , ( I ) Cement , ( Ii ) Sand , ( Iii ) S Chips , ( Iv ) Stone , ( V ) Bricks , ( Vi ) Metal , Add Gst @12% , Add Labour Cess @1%