Bids Are Invited For Surface Dressing - Surface Dressing N Exc 15Cm Deep In Soft/Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. , Rough_Excavation - Rough Excavation N Exc 1.5M Deep And Getting Out In Soft/Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. , Excavation In Trenches - Excavation In Trenches N.Exc 1.5M Deep In Soft/Loose Soil Not Exceeding 1.50 M Wide And N Exc 1.50M In Depth For Foundation Etcor For Shafts, Wells, Cess Pits, Man Holes Pair Holes Etc Not Exc 10 Sqm On Plan And Not Exc 1.5M In Depth And Getting Out In Soft/Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. , Returning Filling - Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers N. Exc 25 Cm In Soft/Loose Soil Complete All As Specified And Directed By Engineer-In-Charge. , Removal Soil - Removal Of Excavated Materials N Exc 50M And Depositing Where Directed At A Level N Exc 1.5M Above The Starting Point Complete All As Specified And Directed By Engineer-In-Charge. , Pcc_01 - M&L For Pcc 1:3:6 Type C-2 (Using 40Mm Graded Aggregate) As In Foundations Or Mass Concrete Complete All As Specified And Directed By Engineer-In-Charge. , Formwork - M&L For Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Pedestals, Beams Any Type, Sides And Soffits (If Any) Of Foundation And Plinth Beamsand Similar Work Complete All As Specified And Directed By Engineer-In-Charge. , Tmt_10Mm - M&L For Mild Steel Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hooping For Column, Hooking Ends And Binding With And Including Mild Steel Wire (Annealed) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And Directed By Engineer-In-Charge. , Tmt_ Bars_2 - All As Per Item No 8 As Above But 8Mm Dia For Strupps Complete All As Specified And Directed By Engineer-In-Charge. , M-25 - M&L For Rcc (Design Mix) M-25 (Using 20Mm Graded Aggregate) As In Footings, Foundations, Plinth Beams, Columns/Pedestals Etc. And Similar Works Complete All As Specified And Directed By Engr-In-Charge. , Brick_Work - M&L For Brickwork With Subclass B Bricks Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:6 Complete All As Specified And Directed By Engineer-In-Charge. , Rendering _15Mm - M&L For Rendering 15Mm Thick In Cm 1:4 On Fair Faces Of Brick Or Concrete Surfaces Finishing Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. , Bajri - S&L For Moorum/Red Bajri Filling In Floors Or Pavings, Laid In Layers N Exc. 15 Cm Thick Incl Spreading, Levelling And Ramming With Watering And Vibraters Complete All As Specified And Directed By Engineer-In-Charge. , Structural Steel - S&F For Structuralsteel For Prefabricated Structure , The Structure Should Be Disigned As Per Is Code 800:2007 Using Builtup Sections/Square/Rectangular Hollow Sections/Ismb/Iscm For Wall Studs, Bracings, Floor Joints, Runners, Roof Truss, Purlins, Stair Case, Railing, Girts Etc, Minimum Dead Load On Roof To Be Considered Shall Be 0.15Kn/Sqm And Minimum Live Load On Roof Should Be Minimum 0.75Kn/Sqm. Minimum Dead Load On First Floor To Be Considered Shall Be 3.5Kn/Sqm And Minimum Live Load On First Floor Should Be Minimum 0.75Kn/Sqm. The Main Columns And Beams Will Be Made Out Of Ms Section Conforming To Indian Standerd/Bis. The Size Of All Sections As Per Design And Drgs Duly Approved Fom Any Reputed Iit/Nit. The Gusset Plates/Base Plate/Top Plates Shall Be Properly Welded To Column And Beams And All The Plates Shall Be Predrilled For Holdings The Bolts. The Base Plates Shall Be Fixed To The Foundation By Embedding Long Ms Bolts Of 25Mm Dia Of Appropriate Length As Per The Approved Design Complete All As Specified And Directed By Engineer-In-Charge.Connections:- All Welding Shall Be Carried Out Using Mig/Mma Welding Process Or By Suitable Safe Nut Bolts Connections As Per Suppliers/Manufacturers Design And Directions , Wall Panels - S&F For Wall Panels Shall Be Constructed Of 50Mm Thick Puf Insulation Panels, Density Of 40 + 2 Kg/Cum Of Laminated Pre-Coated Gl Outside And Inside Of Walls. The Top And Bottom Sheet Shall Be Az 150 With Min 550 Mpa Tensile Strenght Of 0.8Mm Tct. The Color Of The Top Side Sheet Will Ral 9002 Of 20-30 Microns Pure Polyster Coating Over 4-7 Microns Primer On The Top Side And 5 Microns Of Backer Coat Over The Primer On The Bottom Side Of The Sheet. The Jointing Of Panels Shall Be Using Good Quality Cam-Locks. , Corrugated Steel - S&F Forpre- Painted Galvatume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screwscomplete All As Specified And Directed By Engr-In-Charge. , False Ceiling - M&L For Providing And Fixing Gypsum Board False Ceiling Of 12 Mm Thick Fine Fissure Board Sharped Finished Mineral Fiber Accountic False Ceiling Tiles With Back Of The Duly Sanded And Finished With A Coat Of Protective Paint And Front Duly Finished Of Armstong/Nithobo Flase System Of Size (600X600)Mm Having Noise Reduction Co-Efficient Of 0.55 Light Reflection Of 80% Thermal Conductivity K=0.057 W/Wwc And Humidity Resistance Of 95% Fixed To True Look Pvc Die Kl-24 Suspension System ( Hot Dipped Galvanised Steel Section) Of Exposed T Section Grid With Exposed Face Powder Coated White Colour.The Suspension System Consisting Of Parameter Wall Angle Of Size (24X24)Mm Of Thickness 0.45 Of Mm C/C Universal Main Runner Of T Shape With Double Rotary Stiching Of Size (38X 24)Mm Of Length 1200Mm Made From 0.33 Gs Steel Of Length 3.60 Mtr To Be Spced At 600X600mm Size) C/C Cro Runner T Shape With Double Rotary Siticing Of Size (30X24)Mm Of Length 1200Mm Made From 0.25Mm Thick Gs Sheet Spaced @ 600Mm C/C (600Mmx600mm) Size. The Grid Will Be Fitted With 50Mm Thick 32 Kg/Cum Fibre Glass Insulation Complete All As Specified And Directed By Engr-In-Charge , Pcc_2 - M&L For Pcc 100Mm Thick, 1:3:6 Type C-2 (Using 40Mm Graded Aggregate) As In Floors, Sub-Bases Etc Complete All As Specified And Directed By Engr-In-Charge. , Mezzanine Floor - M&L For Mezzanine Floor Decking Incl Providing 75Mm Thick Pcc And Reinforcement As Per Design, Considered Live Load As Per 350Kg/Sqm Over The Gi Deck Sheets And The Chequred Plate Of Thickness 0.8Mm Shall Rest On Frame Of Ms I-Section Of Appropriated Design Duly Approved From Any Reputed Iit/Nit Completeall As Specified And Directed. , Vitrified Tiles - S&F For Vitrifiedceramic Colouredtiles 10Mm Thick (Squre/Rectangular) Polished, Area Of Each Tile N Exc 0.36Sqm As In Floors Etc. Over 15Mm Thick Screed Bed In Cm 1:6 And Set And Jointed In Neat Slurry And Pointed In White Or Coloured Cement To Match Or To Fixed Using Proper Adhesive Of Make Sikka, Diamond Star, Asian Paint And Equivalent, Fixed On The Floor As Per Manufaturer Specifications And Directions Complete Also As Specified And Directed By Engr-In-Charge. , Non Skid Ceramic - S&F Non Skid Ceramic Colouredtiles 7 To 8Mm Thick (Squre/Rectangular) Area Of Each Tile Exc 0.11Sqm But N.Exc 0.18 Sqm, In Floors Etc. Over 15Mm Thick Screed Bed In Cm 1:6 And Set And Jointed In Neat Slurry And Pointed In White Or Coloured Cement To Match Or To Fixed Using Proper Adhesive Of Make Sikka, Diamond Star, Asian Paint And Equivalent, Fixed On The Floor As Per Manufaturer Specifications And Directions Complete Also As Specified And Directed By Engr-In-Charge. , Glazed Ceramic - M&L Glazed Ceramic Coloured/Printed Tiles In Vertical Surface Of Size 300-350X450x7-8Mm Thick As In Vertical Surface, Fixed Over The Cement Board With Suitable Adhesive Of Make Sikka, Diamond Star, Asian Paint And Equivalent, Fixed As Per Manufaturer Specifications And Directions Complete Also As Specified And Directed By Engr-In-Charge. , Aluminum Door Frame - S&F For Powder Coated Aluminium Door Frame And Shutter With Tinted Glass 5Mm Thick And Pre Laminated Board Both Side Of 12Mm Thick With Complete Accessories Like Handles, Tower Bolts, Sliding Door Bolts, Al-Drops, Hinges, Door Stoper,Screws Etc Complete As Specified And Directed By Engr-In-Charge. , Aluminium_Window - S&F For Powder Coated Aluminium Window And Ventilator Frame And Shutter For Sliding Window And Ventilator (Three Tier) With Grill, Tinted Glass 5Mm Thick, Stainless Steel Wire Mesh And Complete Accessories Like Handles, Tower Bolts, Sliding Door Bolts, Al-Drops, Hinges, Stoper, Screws Etc Complete As Specified And Directed By Engr-In-Charge. , Pipe_25 Mm - S&F For Upvc/Cpvc Pipe Of 25Mm Bore Incl All Necessary Fitting For Hot And Cold Water Supply, Fixed With Wall, Ceiling, Floor, In Trenches Etc. Incl Brackets Complete All As Specified And Directed By Engineer-In-Charge. , Pipe_15 Mm - S&F For Upvc/Cpvc Pipe Of 15Mm Bore Incl All Necessary Fitting For Hot And Cold Water Supply, Fixed With Wall, Ceiling, Floor, In Trenches Etc. Incl Brackets Complete All As Specified And Directed By Engineer-In-Charge. , Tank_2000 Ltr - S&F For Rotational Moulded Polyethylene Double Layer Water Storage Tank Of 2000 Litres Capacity (Cylindrical Vertical With Closedtop) Incl Ball Brass Valve High Pressure Complete All As Specified And Directed By Engineer-In-Charge. , Water Closet Pan - S&F For Vitreous China Water Closet Pan (Pedestal Pattern) With Pvc Seat Cover, White Complete All As Specified And Directed By Engineer-In-Charge. , Wash Basin - S&F For Vitreous China Wash Basin White Oval Type Including Ptmt Waste Fitting 32 Mm Bore, Fixing Brackets And Pvc Waste Pipe Complete , Urinal - S&F For Vitreous China Urinal, Half Stall Type, White Incl Bracing Ptmt Waste Fitting 32Mm Bore, Spreader And Waste Pipe Complete All As Specified And Directed By Engineer-In-Charge. , Flushing Cistern - S&F For 10 Ltr Capacity Pvc Valveless , Syphonic Actoin Type, Flushing Cistern, Low Level White, With Inlet Ball Valve , Float & Handle Including Brackets And All Fittings Complete All As Specified And Directed By Engineer-In-Charge. , Angle Cock - S&F For Angle Cock Cast Copper Alloy, Fancy Type Chromium Plated, 15 Mm Dia Of Bore Complete All As Specified And Directed By Engineer-In-Charge. , Stop Cock - S&F For Stop Cockcast Copper Alloy, Fancy Type Chromium Plated With Long Shankandcup (Concealed Type) 15Mm Dia Of Bore Complete All As Specified And Directed By Engineer-In-Charge. , Pillar Tap - S&F For Pillar Tap 15Mm Dia Of Bore, Cast Copper Alloy, With Capstan Heads, Chromium Plated, Fancy Type Complete All As Specified And Directed By Engineer-In-Charge. , Bib Tap - S&F For Bib Tap 15Mm Bore Chromium Plated Bib Taps, Cast Copper Alloy, Fancy Type Complete All As Specified And Directed By Engineer-In-Charge. , Shower Rose - S&F For Shower Rose, Chromium Plated ,125Mm With Or Without Swivel Joints, Any Size, Including Fixing To Steel Pipeor Union Complete All As Specified And Directed By Engineer-In-Charge. , Steel Grating - S&F For Steel Grating Doom 125Mm Dia With Waste Hole Complete All As Specified And Directed By Engineer-In-Charge. , Pvc Connections - S&F For Pvc Connections 15Mm Size With Ptmt Nuts Of Length 600Mm Complete All As Specified And Directed By Engineer-In-Charge. , Health Faucet - S&Ffor Helth Faucet, Handle Control, Brass Type, With Wall Hook And Hose Pipe 1.0M Long Complete All As Specified And Directed By Engineer-In-Charge. , Towel Rail - S&F For Tubular Towel Rail 20Mm Dia Brass Chromium Plated Complete All As Specified And Directed By Engineer-In-Charge. , Soap Dish - S&F For Soap Dish, Chromium Plated Complete All As Specified And Directed By Engineer-In-Charge. , Looking Mirror - S&F For 600X450 Mm Beveled Edge Looking Mirror Of Selected Quality Glass And Backing With 6Mm Thick Ac Building Board And Fixed To Wall With Screws Complete All As Specified And Directed By Engineer-In-Charge. , Swr Pipe_100Mm - S&F For 110Mm Pvc (Swr) Pipe Single/Double Socketed, In Any Length With Rubber Ring Joints, Fixed To Wall, Floor, Roof Etc Incl All Necessary Fittings Like Socket, Elbow, Bend, Tee, Adhesive, Clamps And Screws Complete All As Specified And Directed By Engineer-In-Charge. , Swr Pipe_75Mm - All As Per Item No 43 Above But 75Mm Dia Complete All As Specified And Directed By Engineer-In-Charge. , Pcc_3 - M&L For Cement Concrete 1:3:6 Type C2 (Using 40Mm Graded Aggregate) As In Bed With Thickness Of Bed Below The Barrel Of Pipe As 100Mm And Width Of Bed As 450Mm To Drain Pipes Of 150Mm Internal Diaincluding Packing Under, And Haunching Against The Sides Of Pipes After They Are Laid And Tested Complete All As Specified And Directed By Engineer-In-Charge. , Rcc Pipe - M&L For Reinforced Concrete Pipes 150Mm Bore Dia, Class Np2, Laid And Jointed Complete With Collars Complete All As Specified And Directed By Engineer-In-Charge. , Pcc_B1 - M&L For Pcc 1:2:4 Type B1 (Using 20Mm Graded Aggregate) As In Coping, Manholes Cover, In Surface Chanel And Drains, Coping Of Ples Including Necessary Form Work Complete All As Specified And Directed By Engineer-In-Charge. , Cutting Manholes - M&L For Cuttingintoexistingmanholes For Connecting New Drains Of Internal Dia Of Pipe 150Mm, Making Good To Pipe And Rendering, Cutting Out Existing Benching For And Forming Branch Channel (1/2 Round Or 3/4 Section) In Cement Concrete 1:2:4 Type B-L Smooth Finished, And Reforming Benching As Required Complete All As Specified And Directed By Engineer-In-Charge. , Point Wiring_1 - M&L For Point Wiring With Single Core Pvc Insulated Unsheathed 1100 Volt Grade Cable With Multistranded Copper Conductor Of Size 1.5 Sq Mm (Nominal Area) Drawn Through And Including Non Metallic Rigid Pvc Conduit Medium Duty Isi Marked Not Less Than 20Mm Dia, Fixed In Wall, On Roof With Gi Saddles Gi Screws, Rawal Plugs (Concealed Conduit In Wall Wiring) With All Fittings Including Tee, Junction Boxes And Provision Of Pressed Steel Terminal Box Of Suitable Size With 3 Mm Thickhylamlaminated White Sheet Cover For Mounting Switch Sockets And Regulators And Drawing Continuous Earth Wire With And Including Pvc Insulated Unsheathed 1100 Volts Grade Cable With Multistranded Coper Conductor Of Size 1.5 Sq Mm (Nominal Area) Complete All As Specified And Directed By Engineer-In-Charge For Following (Color Coding To Be Followed) :-(A)One Light/Fan Point Controlled By One Switch. , 3 Pin 5 Amps Socket - All As Per Item No 49 Above But One 3 Pin 5 Amps Socket Outletindependent With Cables 1.5 Sqmm Size Complete All As Specified And Directed By Engineer-In-Charge , Light Point - All As Per Item No 49 Above But One Lightpoint Controlled By Two2-Wayswitches,With Cables 1.5 Sq. Mmsizcomplete All As Specified And Directed By Engineer-In-Chargee , 3 Pin Socket Outlet - All As Per Item No 49 Above Butone 3 Pin Socket Outlet 5 Amps Point On Same Board With Other Switches With Cable 1.5Sqmm Complete All As Specified And Directed By Engineer-In-Charge , Point Wiring _2.5 Sqmm - All Same As Per Item No 49 Above But With Conductor Of Size 2.5 Sq Mm (Nominal Area) For One 3 Pin Socket Outlet 15 Amps On Independent Board Complete And Earth Continuity Wire With 1.5 Sq Mm Pvc Insulated Stranded Copper Conductor Cable Complete All As Specified And Directed By Engineer-In-Charge , Switch Piano - M&L For Switch Piano Type 5 Amps, Single Pole One Way Complete All As Specified And Directed By Engineer-In-Charge , Socket Outlet 5 Pin - M & L For Socket Outlet 5 Pin , 5 Amps Flush Type Complete All As Specified And Directed By Engineer-In-Charge , 2 Way Switch - M&L For 2 Way Switch 6 Amps, Complete All As Specified And Directed By Engineer-In-Charge , Switch_15Amp - M&L For Switch Piano, Flush Type 15 Amps Single Pole One Way Complete All As Specified And Directed By Engineer-In-Charge , Socket Outlet 2 In 1 - M&L For Socket Outlet2 In 1, 3 Pin, 5 And 15 Amps Flush Type Complete All As Specified And Directed By Engineer-In-Charge , Metal Enclosure - S&F Single Pole And Neutralsheet Metal Enclosure With A Two Pin And Earth Plug And Socket Complete With Plug Top 20 Amps With Mcb Sp 230 Volt 20 Amps Complete All As Specified And Directed By Engineer-In-Charge , Fan Regulator - S & F Stepped Type Electronic Fan Regulator Flush Type Complete All As Specified And Directed By Engineer-In-Charge , Ceiling Rose - S&F For Ceiling Rose Surface Bakelite 65X50mm Two To Three Terminals Complete All As Specified And Directed By Engineer-In-Charge , Tube Light _ 20 W - S & F Led Tube Light Selfballasted Batten 1 X 20 W, 230 V , 4 Feet Longextruded Aluminium Body With Pc Diffuser , Integral Isolated Driver More Than120 Degree Wide Light Cct 6500 K Complete With All Accessories Internally Prewired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable And Tubes Wit Suitable Size Complete All As Specified And Directed By Engineer-In-Charge. Make : Poly Cab , Tube Light_12 W - S & F Led Tube Light Selfballasted Batten 1 X 12 W, 230 V , 2 Feet Longextruded Aluminium Body With Pc Diffuser , Integral Isolated Driver More Than120 Degree Wide Light Cct 6500 K Complete With All Accessories Internally Prewired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable And Tubes Wit Suitable Size Complete All As Specified And Directed By Engineer-In-Charge. Make Plycab , Ceiling Fans - Supply And Fixing Ceiling Fans Completewith Blades, Down Rodselectronicregulator And Accessories, 230 V, 1400 Mm Sweep. Min Air Delivery 245 Cfmwith Service Value 6.00 Bee. Five Star Rated With Brushless Direct Current Motor (Bldc)Complete All As Specified And Directed By Engineer-In-Charge, , Exhaust Fan_300Mm - Supply And Fix Exhaust Fan, Steel Bodyac Single Phase. 230V Of Size 300Msweep With, Blades, And Frame And Louvers Complete All As Specified And Directed By Engineer-In-Charge , Exhaust Fan_450Mm - Supply And Fix Exhaust Fan, Steel Bodyac Single Phase. 230V Of Siz450msweep Heavy Duty With, Blades, And Frame And Louver Complete All As Specified And Directed By Engineer-In-Charge , Sub Main Wiring - Sub Main Wiring Alongwith Earth Wire, Single Core Cable, 2X10 Sqmm, Pvc Insulated Pvc Unsheathed Stranded Fr Copper Conductor Cablein And Including Pvc Concealed/ Surfaceconduit Of Earth Wire With 1X6 Sq Mmcopper Cable Fixed Along With The Sub Main In Pvc Conduit And Connecting To Earth Dollycomplete All As Specified And Directed By Engineer-In-Charge , Tpn Vertical Db - S&F Tpn Vertical Db4 Way Ip 42 Double Doorsuitableto Accomodate 3/4 Pole Mccb As Incomersp/Dp/Tp Outgoing Mcb,S 4 Way (Power Shell)Sheet Steelenclosurewith Detachable Gland Plates For Flush Powder Coated With Din Rail Removable Busbar Shrouded Neutral Link With Conditional Short Circuit Rating Of 10 Ka Ratingcomplete All As Specified And Directed By Engineer-In-Charge . Make Havells Or Equivalent Model Of L & Tlegrand/Strandard/Schnider , Spn Mcb - S&F Spnmcb Distribution Board16 Way With 200 Amps Rated Busbar Ip 42 Double Door (Power Shell)Steel Sheet Phosphatised Powder Coated With Din Rail Removable Busbar Shrouded Neutral Link With Conditonal Short Circuit Rating Of 5 Ka Complete All As Specified And Directed By Engineer-In-Charge , Mccb 4 Pole - S&F Mccb 4 Pole160 Amps 36 Kacomplete All As Specified And Directed By Engineer-In-Charge , Circuit Breaker_1 - Supply And Fixing Amp Rating 240V, 10Ka C Curveminiature Circuit Breaker (Mcb) Of 63 Amp Spnin The Mcbdb Complete With Connection Testing And Commissioning Complete All As Specified And Directed By Engineer-In-Charge , Circuit Breaker_2 - Supply And Fixing Amp Rating 240V, 10Ka C Curveminiature Circuit Breaker (Mcb) Of 5 To 32 Amp Spin The Mcbdb Complete With Connection Testing And Commissioning Complete All As Specified And Directed By Engineer-In-Charge , Earthing_1 - M & L For Earthing In Repairs Complete With Galvanised Steel Earth Plate Electrode 600 X 600 X 6.0 Mm Thick Burried Directly In Ground (Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Meters Below Ground Level Connected By Gi Wire,4.0 Mm Dia As Earth Lead By Means Of Nuts And Bolt,Thimbles, Check Nuts, Washers Of Gi Or Steel Including Pcc (Concrete Chamber) Shall Be Pcc 1:3:6 Type C-1 Using 20 Mm Graded Stone Aggregate,With Fair Finish,Internal Surface Of Concrete Chamber Shall Be Given Internal Dimension 300 Mm X 300 Mm X300 Mm,15 Mm Thick Plaster In Cm 1:4,Funnel With Wire Mesh,80 Mm Thick Rcc Pit Cover 320 X 320 Mm Of Rcc 1:2:4 Type B1 Using 20 Mm Graded Stone Aggregate Reinforced. Xpm Jally And Charcoal,Dust And Common Salt All As Shown In Electrical Plate No 3 Of Mes Ssr Part -1 (2009) And Specified,Provision Of Gi Wire Upto 7.5 Metre Long Protected By 20 Mm Dia Light Grade Pipe And Watering Pipe Shall Be 15 Mm Bore Light Grade ,Excavation, Earth Work,Connecting The Earthing To An Earthing Test Point Or To Main Switch Board As Specified And Testing On Completion Complete All As Specified And Directed By Engineer-In-Charge .Note: Rcc Pit Cover Shall Be Precast Of Rcc (1:2:4) Type B1,80 Mm Thick Reinforced With Xpm Weighting Not Less Than 4 Kg/Sqm In Lieu Of Ci Cover. , Led Street Light - Supply And Installing Aesthetically Designed Highly Efficient Led Street Light Made Of Pressure Die Cast Aluminium Housing & Enclosed With Toughened Glass, Top Maintainableip66 45 Watts Andgi Bracket, Clamps ,Gipipe Andand Fixing Arrangement Complete All As Specified And Directed By Engineer-In-Charge .Make:- Halonix Hlsld-14-45-Cwl , Geyser_50Ltr - Supply & Install Water Heater (Geyser) Of 50 Ltrs Capacity Including Mounting On Wall & Supply And Connecting Inlet Outlet Pipes To Water Supply Pipeline Incl Suitable Size Fasteners & Also Associated Wrks Etc Complete All As Specified And Directed By Engineer-In-Charge , Water Heater - Supply & Install Instant Water Heater Of 3 Ltrs Capacity Including Mounting On Wall & Supply And Connecting Inlet Outlet Pipes To Water Supply Pipeline Incl Suitable Size Fasteners & Also Associated Wrks Etc Complete All As Specified And Directed By Engineer-In-Charge . Make- Crompton Solarium Neo Or Equivalent In Havells, Bajaj Etc. , Desert Cooler - S&F Desert Cooler Electric Driven (Single Phase), Having Nominal Air Flow Capacity Of 2550 Cum Per Hour (Or Nearest Size) Plastic/Pvc Body Complete All As Specified And As Directed By The Engineer-In-Charge. Make: Kenstar Turbo Cool Max Super , Water Dispenser - S&F Three Tap Water Dispenser With Hot, Plain & Cold Taps With 20 Ltrs Storage Capacity Complete All As Specified And As Directed By The Engineer-In-Charge. Make: Blue Star (Bwd3fmrga) , Gi Tube_50Mm - Supply, Laying And Fixing Intrenchesgalvanised Lron Water Tubing, Medium Grade Including Necessary Fittings Such As Gi Bends,Tees,Union Etc All As Required At Site Complete And Connecting To Water Supply Pipe Line And Including Cutting, Chesing And Making Good Disturb Surface For The Following Sizes Complete All As Specified And As Directed By The Engineer-In-Charge.(A) 50 Mm Bore , Gi Tube_25Mm - All As Per Item No 79 Above But 25Mm Bore Complete All As Specified And As Directed By The Engineer-In-Charge. , Valve Chamber - M&L For Valve Chamber Of Size 90X90x60 Cm With Brick Work/Masonary Plastering, Necessary Excavation & Earth Work Incl Ms Sheet Cover 3.15Mm Thickness Along With Angle Iron Frame Of Size 40X40x6 Mm Size With Hinges, Nut/Bolts Incl Painting Of Ms Cover With One Coat Of Red Oxide Primer & 2 Coat Of Synthetic Enamel Paint Complete All As Specified And As Directed By The Engineer-In-Charge. , Ci Di Pipe - M&L For Cutting Of Existing Of Ci/Di Pipe Line Of 100Mm Dia & Insertion Of Spigot & Socket Type Tee Of Size (100X100x50mm) Dia Incl Filling Of Joint As Required Etc Complete All As Specified And As Directed By The Engineer-In-Charge. , Gun Metal Gate - Supply And Fix Connected Gun Metal Gate Valve Isi Marked With Iron Wheel Head Screwed Both Ends For Iron Pipes And Fixed For The Sizes Of 25Mm Complete All As Specified And As Directed By The Engineer-In-Charge. , Boring Of Holes - Boring Of Holes Under Road, Pavement, Hard Standing By Trenchless Technology Using Ultra Sounding Technique And Necessary Machine Complete All As Specified And As Directed By The Engineer-In-Charge. , Sand - Supply, Filling, Spreading Levelling And Well Ramming The River Sand Around Cable In Trenches For Cable Cushioning Complete All As Specified And As Directed By The Engineer-In-Charge. , Bricks_01 - M&L For Sub Class `B` Bricks For Cable Protection Complete All As Specified And As Directed By The Engineer-In-Charge. , Cable Xlpe - Supply & Laying Connectingof Cable Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Or Wire Armoured Lt 1100 Volts Grade Aluminiumconductor Of Cross Sectional Area 95 Sqmm 3.5 Coreincl Thimbles As Required With Suitable Size Of Clamps On Wall/Under Trenches Etc Complete All As Specified And As Directed By The Engineer-In-Charge. , Mccb 4 Pole 200 Amps - S&F Mccb 4 Pole200 Amps 36 Kacomplete All As Specified And As Directed By The Engineer-In-Charge. , Tube_40Mm - M&L For Tubes, 40Mm Light Grade Galvanised,With All Fitting And Fixed Complete To Walls And Ceilings Or Laid In Floors For Cable Protection Complete All As Specified And As Directed By The Engineer-In-Charge. , Dg Set 62.5 Kva - Supply And Installation Of Silent Diesel Engine Driven Generating Set 415 Volts, 3 Phase 4 Wire, Engine62.5 Kva Three Phase Silent D G Set Model: Kg1-62.5Ws, Comprising Of 62.5 Kvawater- Cooled Diesel Engine Model: 4R810ta G1 At 83 Bhp And 62.5 Kva / 50 Kw Three Phase Alternator, Coupled On A Common Base Frame Fitted With Avm Pads Complete With Amf Panel, Fuel Tank & Standard Accessories Incl Foundation Along With Necessary Earth & Masonary Work Complete All As Specified And As Directed By The Engineer-In-Charge. , Earthing_2 - M & L For Earthing Complete With Galvanised Steel Earth Plate Eletrode 60Cmx60cmx6mm Thick Buried Directly In Ground Vertically To (Earth Pit Not Less Than 2.25 Meters Deep Below Normal Ground Level) With Top Edge Of Plate Not Less Than 1.5 Meters Below Normal Ground Level, Connecting To The Galvanised Iron Strip Of Size 32X6mm Size, By Means Of Bolts, Nuts, Check Nuts And Washer Made Of Gi Or Steel Earth Connecting With Test Point, Provision Of Charcal And Salt In Alternate Layers, Watering Pipe 20Mm Dia Medium Grade Ms Funnel With Jali, Pcc M-15 Type B-1 In Pit With Xpm Not Elss Than 4Kg Per Sqm And Earthpit With Cover Returning, Filling, Removing Excavated Material All As Specified In Electrical Plate No 3 Of Ssr Part-I Making Good Excavated Surfaces Such As Hard Standing Refixing Machine Pressed Precast Concrete Interlocking Paver Blocks Removed During Excavation On Earthpit To Mach Existing Surfaces After Taking Out Old/Unserviceable One Complete And Testing On Completion Complete All As Specified And As Directed By The Engineer-In-Charge. , Pcc_4 - M&L Pcc 1:2:4 Type B1 Using20 Mm Graded Stone Aggregate For Coping Of Pole Using Extra Cement For Smooth Finish Including Necessary Form Work Reqd Incl Demolition Of Existing Damagedcoping Of Pcc Complete All As Specified And Directed By Engineer-In-Charge , Roof Trusses - S&F In Repair Mild Steel Roof Trusses (Framed), Trrussed, Purlins, Crane Gantries, Rails And Fastenings And Heavy Bracket Framming (Beam, Tee, Angle, Channels Or Flat Sections) Including Distance Pieces, Cleats Etc Conforming To Fe 410-W (Gde-E-250) Quality-Acomplete All As Specified And Directed By Engr-In-Charge , Synthetic Enamel Paint - M&L For Two Coats Of Synthetic Enamel Paint Over Onecoat Of Red Oxide Including Preparation Of New Or Previously Untreatedsteel/Iron Surfaces Of Any Description Over 10 Cm In Width Or Girth, Not Otherwise Described Andcomplete All As Specified And As Directed By Engr-In-Charge , Boring Of Holes - Boring Of Holes Under Road, Pavement, Hard Standing By Trenchless Technology Using Ultra Sounding Technique And Necessary Machine Including Hdpe Pipe Of 150 Mm Dia Suitable For 0.4 Mpa Working Pressure Complete All As Specified And As Directed By The Engineer-In-Charge. Total Quantity : 1