Power Unit For Panchayat Office Power Unit For Panchayat Office , 1 Providing Diesel Generator , Od1379009 / 2021_2022 Supply, Conveyance, Installation, Testing And Commissioning Of Of 40 Kva Dg Set With Standard Control Panel, Base Frame, Fuel Tank , Battery With Leads And Other Accessories With Type Approved Integral Kg Canopy As A Complete Set. Including First Fill Of Lube Oil And Engine Safeties – Llop, Cht , Od1379078 / 2021_2022 Supply, Providing And Clamping Exhaust Pipe Extension Of Size 75 Mm And Wall Thickness 5 Mm With Mineral Wool Insulated And Al Cladding As Requires , 2 Electrical Works , 90.12.7.28 Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.3.5 Core 35 Sq Mm With Factory Made Clamp , 9.1.21 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1 / 2X 35 Sq. Mm ( 32Mm ) , 90.6.5.18 Supply And Drawing The Following Sizes Of Multi-Core Pvc Insulated & Frls Pvc Sheathed 650 / 1100 V Grade Copper Conductor Round Flexible Cables Conforming To Is 694 Part I 1960 In The Existing Surface / Recess Conduit As Required Including Giving Necessary Connections Of The Following Sizes.4 Core 1.50 Sq Mm , 1.21.1 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm , Od1379077 / 2021_2022 Supply And Fixing Automatic Transfer Switch Of 125A, 415V, Ac 23A, 4P ( Control Voltage 240 Vac ) Motorised Changeover - Open Execution, Auxc - 2000 Controller With Wire Harness & Illuminated Push Button Assembly With Wire Harness , 90.14.1.2 Fabrication, Supply, Conveyance, Installation Testing And Commissioning Of Floor Or Wall Mounting, Dust And Vermin Proof, Cubicle Type Mv Panel Board Comprising Of The Following Components / Devices & Complying To Is 8623.<Br>Fabrication Of Fully Partitioned, Dust And Vermin Proof Enclosure For Panel Assembly As Per Form 4 Of Is 8623 ( With Latest Amendments ) Using Crca Sheet As Per Approved Design And Requirement, With Front And Rear Access Facility, Bus Bar Chambers, Hinged Doors For All Switch Gear Compartments, Earthing The Doors Using 4 Sq Mm Braided Copper Conductor, Providing Necessary Cut-Outs For Mounting Meters, Relays, Indication Lamps, Bus Bar Interconnection Etc, Detachable Covers For Bus Bar Chamber And Cable Alley, Powder Coating The Assembly After Subjecting To 7 Tank Process Etc As Required. Crca Sheet Alone Be Used For The Fabrication. Angles / Flats / Slotted Angles Etc Shall Not Be Used For The Fabrication Of Panel Assembly. The Measurments Will Be Taken The Area Of The Complete Sheets Used For Panel Board Including Partitions, Folding, Shrouding Etc.Supply And Fabrication Of Mv Panel Board Using 1.6Mm Crca Sheet, Powder Coated ( Excluding Base Frame ) , 90.14.3.2 Supply And Providing Heavy Duty A Section Neoprene Gasket In The Panel Boardu Section Rubber Beeding Suitable For 1.60 / 2.00 Mm Sheet , 90.14.5 Supply And Fabrication Conveyance And Installation Of Angle Iron Frame Work For Wall Mounting Panel Board , 90.14.10.3 Supply, Conveyance And Fixing The Following Types & Current Rated Control Gears & Switchgears Conforming To Is 13947 Suitable For 440 V, 50 Hz, Ac Supply In The Existing Panel Assembly As Required.16 A-100A, 16 Ka ( Ics=100%Icu ) , 4 Pole, Current Limiting Type Mccb Having Thermal Setting Range Of 80 - 100% With Thermal Magnetic Release Having Adjustable Ol , 90.14.11.13 Mccb Accessoriessupply And Fixing Rotary Handle, External Type ( Including Buc Handle With Door Interlock ) In The Existing Mccb Of Rating Up To 250 A , 90.6.4.63 Supply And Drawing 650 / 1100 V Grade Frls Pvc Insulated Stranded Single Core Copper Conductor Cables Conforming To Is 694 Part I 1990 In The Existing Surface / Recess Conduit As Required Including Giving Necessary Connections Of The Following Sizes.16.00 Sq.Mm 4 Run , 3 Civil Works , 14.1 Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Leadof 50 Metres. , 14.10 Providing And Laying In Position Reinforced Cement Concrete 1 :2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. Asrequired ( Excluding Reinforcement ) . , Od1379018 / 2021_2022 Reinforcement For R.C.C Works, Bend Tied And Placed In Position ( Plain Grill Requiring Bend Cold ) Using Tor Steel , 4 Earthing , 5.2 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providingmasonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. Withcharcoal / Coke And Salt As Required , 90.16.1.6 Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required6.00 Mm Copper Conductor ( 4 Swg ) , 90.16.5.6 Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.6. Mm ( 4 Swg ) , 5 Preparing Of All Necessary Drawings And Getting Approval From Electrical Inspectorate , Arranging Inspection Etc. ( Including Statutory Fee )