Supply Of Supply Of Outdoor Type Distribution Transformer Copper Wound 11Kv/416 Volts ,3 Phase , 50Hz,250Kva As Per Is - 1180 -2014 /Bis Specification No. 2026 (Part-1) - 1977 Whichever Is Latest With First Filling Of Oil As Per Bis 335,1993. Having Off L-Andhra Pradesh

East Coast Railway has published Supply Of Supply Of Outdoor Type Distribution Transformer Copper Wound 11Kv/416 Volts ,3 Phase , 50Hz,250Kva As Per Is - 1180 -2014 /Bis Specification No. 2026 (Part-1) - 1977 Whichever Is Latest With First Filling Of Oil As Per Bis 335,1993. Having Off L. Submission Date for this Tender is 29-11-2021. Distribution Transformer Tenders in Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

29791965
Supply Of Supply Of Outdoor Type Distribution Transformer Copper Wound 11Kv/416 Volts ,3 Phase , 50Hz,250Kva As Per Is - 1180 -2014 /Bis Specification No. 2026 (Part-1) - 1977 Whichever Is Latest With First Filling Of Oil As Per Bis 335,1993. Having Off L
Open Tender
NCB
Andhra Pradesh
29-11-2021

Tender Details

Supply Of Supply Of Outdoor Type Distribution Transformer Copper Wound 11Kv/416 Volts ,3 Phase , 50Hz,250Kva As Per Is - 1180 -2014 /Bis Specification No. 2026 (Part-1) - 1977 Whichever Is Latest With First Filling Of Oil As Per Bis 335,1993. Having Off Load Tap Changer Of +/- 7.5% In Steps Of 2.5%. The Transformers Manufactured Shold Be Tested At Your Factory Before Dispatch (Routine Test) As Per Iss 2026 / 1180 And Test Certificate Shall Be Produced Along With Supply. Vector Group %U2013dyn11 Impedance 4.50% Level 2 Losses At 50% ---980 Watts Losses At 100% --- 2930 Watts Level -2Supply Of Outdoor Type Distribution Transformer Copper Wound 11Kv/416 Volts ,3 Phase , 50Hz,250Kva As Per Is - 1180 -2014 /Bis Specification No. 2026 (Part-1) - 1977 Whichever Is Latest With First Filling Of Oil As Per Bis 335,1993. Having Off Load Tap Changer Of +/- 7.5% In Steps Of 2.5%. The Transformers Manufactured Shold Be Tested At Your Factory Before Dispatch (Routine Test) As Per Iss 2026 / 1180 And Test Certificate Shall Be Produced Along With Supply. Vector Group %U2013dyn11 Impedance 4.50% Level 2 Losses At 50% ---980 Watts Losses At 100% --- 2930 Watts Level -2,Supply Of Outdoor Type Distribution Transformer Copper Wound 11Kv/416 Volts ,3 Phase ,50Hz,250Kva As Per Is - 1180 -2014 /Bis Specification No. 2026 (Part-1) - 1977 Whichever Is Latest With First FillingOf Oil As Per Bis 335,1993. Having Off Load Tap Changer Of +/- 7.5% In Steps Of 2.5%. The TransformersManufactured Shold Be Tested At Your Factory Before Dispatch (Routine Test) As Per Iss 2026 / 1180 And TestCertificate Shall Be Produced Along With Supply. Vector Group %U2013dyn11 Impedance 4.50% Level 2 Losses At50% ---980 Watts Losses At 100% --- 2930 Watts Level -2

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document