Smoke Management System Tender For Sitc Of Smoke Management System , 300Mm Dia For Store Room , Air Distribution , Ducting , Supply, Installation And Testing Of Factory / Site Fabricated Gss Ducts As Per Smacna Of Following Thickness Including Necessary Supports, Adjustable Dampers, Vanes, Etc. Complete As Per Specifications , Thickness 0.63 Mm Sheet , Thickness 0.80 Mm Sheet , Thickness 1.00 Mm Sheet , Thickness 1.25 Mm Sheet , Supplying & Fixing Of Opposed Blade Volume Control Dampers In Supply Air Duct Collars As Per Specifications As Required. , Supplying & Fixing Of Powder Coated Extruded Aluminium Supply Air Grills With Aluminium Volume Control Dampers Complete As Required. , Supplying & Fixing Of Powder Coated Extruded Aluminium Return / Exhaust Air Grill Without Volume Control Dampers Complete As Required. , Supply, Fixing And Commissioning Of Fresh / Exhaust Air Louvers With Section Comprising Of Powder Coated Aluminium Louvers & Bird Screen As Required. , Supply, Installation & Testing Of Gi Back Draught Dampers Similar Construction Of Gravity Louvers, Provided With Suitable Links To Prevent The Back Pressure Of Air. , Supply, Fabrication, Installation And Testing The Flexible Connections Constructed Of Fire Resistant Double Resin Sleeve As Required And As Per Specifications. , Hvac Electrical Work , Design, Manufacture, Supply, Installation, Testing And Commissioning Of The Following Cubicle Type, Wall Mounted Control Panels Including Anchoring Into The Wall, Wiring And Earthing Terminating Into Mpcb In Each Panel Shall Be Provided By The Electrical Contractor. , 40A Tpn Mcb With 5 Hp Hp Three Phase Dol Starter With Overload Relay And Single Phase Preventer . Each Of These Compartment Shall Contain Indicating Lamp With On / Off / Trip Status For Fan Axial Fans. , 25 / 16A Tpn Mcb With 0.5 To 2Hp Three Phase Dol Starter With Overload Relay And Single Phase Preventer . Each Of These Compartment Shall Contain Indicating Lamp With On / Off / Trip Status For Axial Fans. , Supply Of Xlpe Insulated And Pvc Sheathed Aluminium Conductor Armoured Cable Of 1.1 Kv Grade Confirming To Is : 7098:1988 With Upto Date Amendments Of Following Sizes. , 4.0 Core, 6 Sq.Mm. , Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. , 100 Mm Width X 50Mm Depth X 1.6 Mm Thickness. , 150 Mm Width X 50Mm Depth X 1.6 Mm Thickness. , Earthing , Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess , Total Amount Including Gst