| 1 | SCH \"A\" PART-I |
| 2 | Dismantling asbestos cement (corrugated, semi-corrugated etc) sheets in roof coverings Complete all as specified and directed. |
| 3 | Dismantling timber scantling 40 Sqcm and over in section, in any position of framed work Complete all as specified and directed. |
| 4 | All as per item No. 1.02here-in-before but as in unframed work complete all as specified and directed. |
| 5 | Dismantling wrought Iron or mild steel work of any description not other wise provided for complete all as specified and directed. |
| 6 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and directed. |
| 7 | M&L forPCC(1:4:8) type D2 (using 40 mm graded aggregate) as in fdn, filling and mass concrete complete all as specified and directed. |
| 8 | M&L PCC (1:2:4) type B1 using 20 mm graded aggregate for bearing/bed plates, copings, kneelers, apex stones, kerb stones etc incl weathering, slightly rounded or chamfered angles and throating complete all as specified anddirected. |
| 9 | S & Frolled mild steel workin tubular trussesincl necessary welding/fabrications completeall as specified and directed. |
| 10 | S & F gusset plates etc incl necessary welding drilling for fixingetc complete all as specified and directed. |
| 11 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick ofcolour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or \"J\"/\"L\"hooks complete all as specified and directed. |
| 12 | All as per item No. 1.10 here-in-before but plain sheet as in ridges, gutters, facia bd etc complete all as specified and directed. |
| 13 | S&F IInd class hardwood in scantling timber unframed work and fixed wrought in any position and in any situation complete all as specified and as directed. |
| 14 | S&F for suspended false ceiling using anodized GI exposed ceiling suspension system of grid size 60 cm x 60 cm width main runner \"T\" section of size 38 mm x 24 mm x 0.4 mm thickness and wall angle of size 24 mm x 24 mm x 0.3 mm thickness and cross Tee of size 24 mm x 24 mm x 0.43 mm thick (using 60 cm x 60 cm E board classic 4 mmthickceiling board ) to be placed in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing position for light fixtures, air conditioning diffuser and ducks, sprinkler, smoke detector etc. The main runner to be secured to structural soffit by hanger @ 1220 mm maximum C/C. The last hanger at the end of each runner should not be placed at more than 450 mm from the adjacent wall. Flush fitting 1200 mm cross \"T\" to be inter locked between main runner @ 610 mm C/C so as to form 600 mm x 600 mm grid complete all as specified and directed. |
| 15 | Demolition of Cement Concrete unreinforced in ground floor and pavings not exc 15 Cm thick below or above ground level complete all as specified and directed. |
| 16 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 17 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified. |
| 18 | Taking down cement plaster on brick or stone walls etc includingracking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed. |
| 19 | Taking down cement plastering on lathingincl removing lathing/wire nettingbuilt in cement mortar complete all as specified and as directed. |
| 20 | M&L for rendering 15 mm thick onBrick wall finished fair & even in CM (1:4) complete all as specified and directed. |
| 21 | Supply only water proofing compound complete all as specified and directed. |
| 22 | M & L for GI wire netting 0.90 mm dia and 12 mm mesh lathing to wood or metal studding and welded with angle iron frame incl all laps, cutting and waste complete all as specified and directed. |
| 23 | M & L for rendering 15 mm thick on one side of lathing finished fair & even in CM (1:4) complete all as specified and as directed. |
| 24 | All as per item No. 1.22here-in-before but for 10 mmthick in CM (1:6) on other side of lathing complete all as specified and directed. |
| 25 | M & L forpreparation of newly plastered surfaces of walls and applyingtwo coats ofcement base paint complete all as specified and as directed. |
| 26 | M&L for two coats of Oil bound distemper on wall surfaces over a coat of primeron newly plastered surface of wall includingpreparation of surface complete all as specified and directed. |
| 27 | M&L for scrapping down oldwall surfaces and applying two coats of oil bound distemper over a coat of primer on walls complete all as specified and as directed. |
| 28 | M & L forscrapping down old wall surfaces and applyingtwo coatstwo coats ofcement base paint complete all as specified and as directed. |
| 29 | SCH \"A\" PART-II |
| 30 | Taking down carefully copper/aluminium point wiring (light, fans, socket etc) complete incl battens and fittings such as switch, ceiling rose, light fittings, regulators, socket etc and making good disturbed surface of wall/floor etc complete all as specified and as directed. |
| 31 | Taking down old unserviceable DBs of any type and capacity complete all as specified and as directed. |
| 32 | M&L for point wiring with 1.5 sqmm PVC insulatedcopper cable 1100 volts gradestranded copper conductor cable drawn through and includingPVC casing and cappingcomplete with all fittings and accessoriesincluding MS box of thickness 1.6mm and hylem sheet cover of 3 mm thick for mounting of switches, sockets, regulators, etc and 1.5 sq mmstrandedPVC unsheathed copper cable for earth continuity for one light/bell point controlled by one switch complete all as specified and as directed. |
| 33 | All as per item No. 2.03 but for one fan point controlled by one switch complete all as specified and as directed. |
| 34 | All as per item No. 2.03 but for one 5 amps switch socket combination on independent board complete all as specified and as directed. |
| 35 | All as per item No. 2.03 but for one 5 amps socket outlet on same board controlled by another switch complete all as specified and as directed. |
| 36 | Supply and fix switch piano flush type, 5 Amps 240 volts single pole one way complete all as specified and as directed. |
| 37 | S&F switch socket combination 2 in 1, 5 amps flush type complete all as specified and as directed. |
| 38 | S&F socket outlet, 5 pin 5amps, flush type complete all as specified and as directed. |
| 39 | S&F in repair Fan capacitor of capacity 2.5 mfd epoxy filled type complete all as specified and as directed. |
| 40 | S&F fan regulator electronic type, rotary step, 240 Volt complete all as specified and as directed. |
| 41 | S&F ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body complete all as specified and as directed. |
| 42 | Supply and fixing surface and wall mounted LED batten fitting energy efficient, including LED tube with complete fitting of 20 watt, including provision of connecting PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100Volts gradefrom ceiling rose complete all as specified and directed. |
| 43 | Supply and draw sub main wiring with two single core 4 sqmm FR PVC insulated copper cable 1100 volts grade multistranded, unsheathed conductor drawn into FR PVC casing and capping and all necessary fittings including 4 sqmm multi strand FR PVC insulated copper wire for earth continuity conductor connected to common earth dollycomplete including taking down the old unserviceable one all as specified and directed. |
| 44 | Supply & FixSP&N DBs, 8 way double door with 200A rated bus bar complete all as specified and directed. |
| 45 | M&L for MCB single pole, \"C\" curve, 10 KA, 6 - 32 amps complete all as specified and directed. |
| 46 | M&L for MCB single pole & neutral \"C\" curve, 10 KA, 32 amps complete all as specified and directed. |
| 47 | M&L for Earthing complete with galvanized steel earth plate electrode 60 x60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts nuts, check nut and washers of GIand GI tubing 15mm bore, light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C 1 pre cast RCC (1:2:4) type B1 cover slab 450 x 450 x 50 mm with one handle for lifting made out of 8 mm dia MS bar, wire mash, 20 mm bore GI tubing(L. G.) for watering ,charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed Electrical plate no 3 of SSR Part-I.Note:- Taking down old unserviceable dilapidated GI earthing of any description included in quoted rate. |
| 48 | Schedule of Credit |