}

Online Tender For Supply, Installation And Commissioning Of Civil Infrastructure For 112 On Turnkey Basis- Providing And Fixing Of Full Glazed 12Mm Thk Toughed Glass Partition, Providing And Fixing Full Height Glass Partition Made Out Of Glazed Partitio-Gujarat

Emergency Management has published Online Tender For Supply, Installation And Commissioning Of Civil Infrastructure For 112 On Turnkey Basis- Providing And Fixing Of Full Glazed 12Mm Thk Toughed Glass Partition, Providing And Fixing Full Height Glass Partition Made Out Of Glazed Partitio. Submission Date for this Tender is 20-11-2021. Coats and Jackets Tenders in Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

29734679
Online Tender For Supply, Installation And Commissioning Of Civil Infrastructure For 112 On Turnkey Basis- Providing And Fixing Of Full Glazed 12Mm Thk Toughed Glass Partition, Providing And Fixing Full Height Glass Partition Made Out Of Glazed Partitio
Open Tender
Indian
Gujarat
20-11-2021

Tender Details

Online Tender For Supply, Installation And Commissioning Of Civil Infrastructure For 112 On Turnkey Basis- Providing And Fixing Of Full Glazed 12Mm Thk Toughed Glass Partition, Providing And Fixing Full Height Glass Partition Made Out Of Glazed Partition With Stanless Steel U Channel Profile In The Top And Bottom With 12Mm Thick Clear Toughened Glass Fixing With Wooden Bedding Filled With The Glass To Be Butt Jointed With 2 To 3 Mm Edge Chamfer And Edge Polishing All Around. Distance Between Two Butt Jointed Glass Panels Not To Exceed 4Mm. Edges And Grooves Between Glass Panels To Be Filled With Clear Silicon Sealant Of Approved Make Neatly Applied As Indicated In The Drawing. As Per The Sample Approved By The Architect. Including Hardware., Full Height Partition ( Fully Solid ) ( 75Mm Thk. ) Providing And Fixing Full Height / Half Height Double Skin Wooden Partition Upto Ceiling Or Beam Bottom As Per Drawing And Framing The Skeleton ( Hard Wood Frame Structure 600X600 Mm ) With 50Mm X 37Mm Thick Vertical And Horizontal Hard Wood ) Both Side Cover With 6Mm Thick Comm. Ply Finished With 1.0Mm Thick Selected Laminate, Without Any Air Gap And Grooving As Per Design. Neccesary Wooden Framing To Be Erected Above False Ceiling. No Extra Cost To Be Paid For The Same. Before Installation, Make Hole / Face Plate For Conduit Pipes Of Electrical / Networking Cables With Openable Stud From Partition Including All Materials And Labour Etc. Open Edges Also Finish With Laminate. Complete As Per Detail Drawing And Instruction Of Engineer-In Charge ( Ref. Dwg. No. ) , Low Height Partition Supplying And Erecting 1200Mm Height Partition Of Modular Tile Based System Of 60-70Mm Thick.Providing And Fixing Low Height Partitions Of 50-55 Mm Thick Frames And 1200Mm Height. The Partitions Are To Be Supplied In Tile And Frame Systems.The Internal Skelaton To Comprise Of Vertical And Horizontal Slotted Painted M.S Members With Skirting And Wire Management Fixing Within Fine Adjustment In Line And Height, Shall Be Able To Incorporate Filling Of Data Wire Including Slots For Table Top, Shelves Support And Switch Board. Corner Post Should Be Fixed On The Floor With Ss Plate For Stability Of The Partition. The Skeleton Of The Partitions Are To Be Supplied With Cap Clip To Accommodate The Top Cap Made Up Of Aluminum Extruded Alloy Section With Round Edge From The Top With Radius Of 6 €“ 9Mm, Which Are Powder Coated With 50 - 60 Dft, Trims Will Be Flat Trim Construction In Aluminum Grade 63400 ( He9 ) As Per Is: 733-1983 With Contoured Edges, Which Is To Be Snap Fitted With The Top Member Of The Frame.The Vertical And Horizontal Member Of The Frame Should Be Connected With The Help Of Angle Which Should Be Spot Welded To The Vertical And Horizontal Channel And End Caps Will Be In Die Cast Aluminum With A Waterfall Edge For A Continuous Transition From Horizontal To Vertical Trim.The Framework Should Have Skirting Of 80-150 Mm Height. For Wire Management, The Slots For Inlet Of Wires Should Be Provided . There Should Be Also Provision To Separate The Data, Electrical And Voice Cable As Per The International Standard. Electrical Provision Should Be Provided At Three Levels, Viz. Skirting Or Above Table Level Or Below Table Level As Desired. This Should Consist Of Power Beams And Switch Plates Made Out Of Crca Steel. Switch Board Raceways Should Be Supplied With Factory Made Cut Outs Corresponding To Anchor Roma Make Or Equivalent Switches As Per The Site Specific Requirments. The System Shall Provide Following Types Of Panels A. Solid Panel - Made From 9 To 9.5Mm Th. Pre-Laminated Particle Board Board, Inner Side To Be Finished With Balancing Laminate. The Cut Edges Of Tiles Should Be Finished With Appropriate Paint And Fitted With Polyacetyle Clips On The Top And Aluminium Clips On The Bottom Which Should Be Snap Fitted On The Given Slots In The Main Frame.B. Fabric Panel - 12 Mm Th Soft Board With Good Quality Fabric Upholstered And Should Be Framed And Fitted In The Similar Pattern As Mentioned Above.Panels Shall Be Mounted On The Skeleton In Order To Facilate Easy Removal / Changing, If Required.System Shall Be Complete With All Accessories Like Shelf, Minor Cabinets, Trays Etc. Easily Mountable On Partition.All The Above Tiles Should Be Fitted With Snap-On Clips On The Top And Aluminium Clips On The Bottom.The Tile Combination Should Be As Per The Instructions Given By Clients / Architects., Glass Divider With Verticle Panel Providing And Fixing 12Mm Thick Glass Divider With Beveled Edge. Glass To Be Fixed With Ss D Bracket.Verticle Panel To Be Made From 25Mm Thick Both Side Prelaminated Particle Board With 2Mm Pvc Edge Bending Edge, Fixed With Table Top.Glass Size: ( 16Inchx16inch ) , Panel:20Inchlx25inchh, Fully Glazed Door Providing And Fixing Glass Door With Patch Fitting As Shown In The Drg. Door Shall Consist Of Approved Make 12Mm Thk. Toughened Clear Float Glass With Pre-Fitted Necessary Hardwares Of Enox / Ozone / Godrej Make For Smooth Swinging Action. Rate Shall Include Necessary Approved Locking Systems, S.S. Brush Finish Handle Pair, Floor Springs ( Heavy Duty Or Equivalent ) , Gaskets And Miscellaneous Hardware Items. Including All Materials And Labour Etc. Complete As Per Detail Drawing And Instruction Of Engineer-In Charge And Consultant.Size Of Each Door Shall Be Measurement As Per Drawing., Fully Solid / Partly Glazed Door Providing And Fixing Both Side Laminated Min 40Mm ( + / -2Mm ) Th. Fully Solid / Partly Glazed Flush Door With Laminate Finished Door As Shown In The Drg. Size Of Each Door Shall Be As Per The Dimensions Given In The Drawing. Door Shall Consist Of Approved Make 8Mm Thk. Clear Float Glass / Ms Powder Finish Perforated Grill Pre-Fitted With Necessary Hardware For Smooth Swinging Action. The Edge Of The Shutter Should Be Surrounded With Wooden Polished / Laminate Bidding.. Rate Shall Include Necessary Approved Mortise Locking Systems, Ss Handle Pair, Floor Springs / Door Closer ( Heavy Duty Or Equivalent ) , Gaskets, Knob, Stopper And Miscellaneous Hardware Items. Including All Materials And Labour Etc. Complete As Per Detail Drawing And Instruction Of Engineer-In Charge And Consultant. The Solid Doors Shall Be Supplied With First Class Ghana Teak Wood Frame Of 125 X 75Mm Finished Size With Necessary Grooves, Wroght Framed And Fixed In Position With Ms Hold Fast, Frame Finished By Monocoat Polish.Size Of Each Door Shall Be Measurement As Per Drawing., Asst. Manager Cabin Table With Pedestal Size : 1500Mm X 600Mm X 750Mm Ht.- Providing And Fixing Table As Described Below: Work Top To Be Made Out Of 25Mm Particle Board Finish With Prelaminated Particle Board Of Approved Shade And Make With Bottom Finished With Backer Laminate. Side Panel Shall Be Made Of 25Mm Thick Prelaminated Particle Board. All Edges Shall Be Provided With Machine Pressed 2Mmthick Pvc Edge Band. The Work Surface Shall Be Provided With Circular Cut Out Of Dia. 65Mm For Passing Of Wires Above Worktop. The Cutouts Shall Be Provided With Abs Grommets And Cable Manager. A Corner Bracket Is To Be Used To Support The Work Surface At The Corner Junction Of The Frames. Modesty Panel - Made From 18Mm Thick Pre Laminated Particle Board On Both Side With Groove Pattern In Front, Back Painted Glass As Per Design. Pedestal Made Up Of 18 Mm Thick Prelaminated Particle Board With Three Drawers As Per Drawings. All Edges To Be Finished With Pvc Edge Band. Rate Is Inclusive Of Provision Of 10 Lever Camlock And Central Rh Locking With Actuator, Locking Strip And Multi €“ Drawer Lock, Brackets For Box-File Pedestals. Rate Is Inclusive Of Metabox Channels, Telescopic Channel Of Ebco Make Or Equivalent For Supporting Drawer. Keyboard Tray Of Inoffit / Ebco Make. Cpu Trolley : M. S. Powder Coated With Castors Complete As Per Detailed Technical Specifications And Drawing., Manager Cabin Table With Pedestal Size : 2100Mm X 675Mm X 750Mm Ht.- Providing And Fixing Table As Described Below: Work Top To Be Made Out Of 25Mm Particle Board Finish With Prelaminated Particle Board Of Approved Shade And Make With Bottom Finished With Backer Laminate. Side Panel Shall Be Made Of 25Mm Thick Prelaminated Particle Board. All Edges Shall Be Provided With Machine Pressed 2Mmthick Pvc Edge Band. The Work Surface Shall Be Provided With Circular Cut Out Of Dia. 65Mm For Passing Of Wires Above Worktop. The Cutouts Shall Be Provided With Abs Grommets And Cable Manager. A Corner Bracket Is To Be Used To Support The Work Surface At The Corner Junction Of The Frames. Modesty Panel - Made From 18Mm Thick Pre Laminated Particle Board On Both Side With Groove Pattern In Front, Back Painted Glass As Per Design. Pedestal Made Up Of 18 Mm Thick Prelaminated Particle Board With Three Drawers As Per Drawings. All Edges To Be Finished With Pvc Edge Band. Rate Is Inclusive Of Provision Of 10 Lever Camlock And Central Rh Locking With Actuator, Locking Strip And Multi €“ Drawer Lock, Brackets For Box-File Pedestals. Rate Is Inclusive Of Metabox Channels, Telescopic Channel Of Ebco Make Or Equivalent For Supporting Drawer. Keyboard Tray Of Inoffit / Ebco Make. Cpu Trolley : M. S. Powder Coated With Castors Complete As Per Detailed Technical Specifications And Drawing., Providing And Fixing Table As Described Below : Work Top Shall Be Made Of 25Mm Th Prelaminated Particle Board With Machine Press 2Mm Pvc Edge Beding., Below Top Finished With Balancing Laminate. Work Top Shall Be Mounted Onto The Partition Panels And Side Panels By Means Of Cantilever Brackets Made From 2.0 Mm Thick Crca Inchgrade Dinch Steel Duly Pre-Treated And Powder Coated In Desired Colour The Work Surface Shall Be Provided With Circular Cut Out Of Dia. 65Mm For Passing Of Wires Above Worktop. These Cut Outs Shall Be Provided With Abs Grommets. A Corner Bracket Is To Be Used To Support The Work Surface At The Corner Junction Of The Frames. All Open Edges Made With Machine Press 2Mm Thick Pvc Beading.Rate Is Inclusive Of Key Board Tray Of Ebco Make. Cpu Trolley: M.S.Powder Coated Trolley With Castors.Supply And Fixing Of 1200Mm X 600Mm Work Table., Providing And Fixing Storage Cabinet With Partly Two Drawers And Partly Sliding Shutter.Entire Body, Shutters, Drawer Fascia, Should Be Made From 19Mm Thick Prelaminated Particle Board.Inner Side Finished With Balancing Laminate.Back Side To Be Made With 9Mm Thick Prelaminated Particle Board. ( Balancing Laminate ) Drawers Sides, Base, To Be Made From 12Mm Thick Pre Laminated . ( Both Side Balancing Laminate ) . Particle Board.One Adjustable Shelf To Be Provided With 19Mm Thick Both Side Pre Laminated Particle Board. ( Balancing Laminate ) All Open Edges To Be Finished With Machine Press 2Mm Thick Pvc Edge Beading. Colour Should Be Match With Laminate.Drawers To Be Slid On Telescopic Chhenel, And Shutter To Be Slid On Alluminium Runners.Both Are Lockable, Provided S.S. Handle.Complete With All Necessary Hardware. 36Inch Lx 26Inch Ht X 16Inch D., Medium Back-.Supplying And Providing High Back Revolving And Tilting Height Adjustment Chair As Below Specification Breatheble Mesh Back With Cushion Febric Seat.Adujustable Lumbar Support.Adujustable Armrest With Pu Padding And Any Posion Locking.Black Five Star Chrome Base Hooded Castors.Seat Cushion Upholstread On Thik Water Proof Plywood And Cut Foam.Multi Posion Locking System.Overall Dimension:Min:H-910Mmxw-660Mmxd-470Mm, Max.:990Mmxw-650Mmxd-470Mm, Supplying And Providing Low Back Revolving And Tilting Height Adjustment Chair As Below Specificationmesh Back With Curved Design.Seat Soft Cushion Febric Upholstread Chair.Black Nilon Base.Overall Dimension:Min:H-850Mmxw-490Mmxd-470Mm, Max.:950Mmxw-490Mmxd-470Mm, Supply And Fixing Seamless Ceiling With Gypboard Of 12.5 Mm Thick, Fixed By Using 25 Mm Long Dry Wall Screws To The Under Side Of The Suspended G. I. Channels Grid. Comprising Of Main, Intermediate And Perimeter Runners, Approximate Sizes For The Same Are 80 X 26 X 0.5 Mm @ 450 Centre To Centre, 45 X 15 X 0.09 Mm @ 1200 Centre To Centre And 20 X 29 Mm Respectively. Grid Is Suspended By G. I. Soffit Cleat ( 37 X 27 X 1.6 Mm ) Using Metal Expansion Fasteners Of 12.5 Mm Dia, 35 Mm Deep, 6 Mm Dia Bolt. G. I. Connecting Clips And Other Accessories To Comply With I. S. 2095 - 1982 And As Per Manufacturer Specifications.All Joints Shall Be Finished With Joint Paper Tape By Using Jointing Compound Of India Gypboard Ltd. And Applying Over It 3 Layers Of The Filler Compound To Provide A Smooth Surface. The Rate Shall Include Making Cut Outs For Tube Lights, Spot Lights, Duct Doors, For Specified Size, Grills Etc. For Which No Extra Payment Will Be Paid. Area Of Cut Outs Will Be Deducted As Per Is 1200. All Curved Surfaces, Recesses, Waffles And Corbellings Shall Be Part Of The Flat Area Measurement, Without Any Extra Cost For The Same. Entire Work Shall Be Carried Out As Per The Detailed Technical Specifications, Drawings And As Per The Instruction Of Engineer- In- Charge. Approved Make: India Gypsum., Providing And Fixing Of Armstrong Mineral Fibre Acoustical Suspended Ceiling System With Fine Fissured ( Bevelled Tegular ) Edge Tiles With Armstrong Silhouette 15Mm Black Treveal Grid System. The Tiles Should Have Humidity Resistance ( Rh ) Of 99%, Nrc 0.6, Light Reflectance =85%, Thermal Conductivity K = 0.052 - 0.057 W / M K, Colour White, Fire Performance Uk Class 0 / Class 1 ( Bs 476 Pt - 6 And7 ) In Module Size Of 600 X 600 X 16Mm , Suitable For Green Building Application, With Recycled Content Of 31%. The Tile Shall Be Laid On Armstrong Silhouette Profile Grid System With 15Mm White Flanges Incorporating A 6Mm Central Reveal In Black Colour And With A Web Height Of 38Mm And A Load Carrying Capacity Of Minimum 15.68 Kgs / M2 And Minimum Pull Out Strength Of 100 Kgs. Silhouette, Main Runners And Cross Tees To Have Mitred Ends And €Œbirdsmouth†Notches To Provide Mitred Cruciform Junctions. The T Sections Have A Galvanizing Of 90 Grams Per M2 And Need To Be Installed With Suspension System Of Armstrong Make.The Tile And Grid System Used Together Should Carry A 30 Year Warranty. Installation: To Comprise Main Runner Spaced At 1200Mm Centres Securely Fixed To The Structural Soffit Using Armstrong Suspension System ( Specifications Below ) At 1200Mm Maximum Centre.  The First / Last Armstrong Suspension System At The End Of Each Main Runner Should Not Be Greater Than 450Mm From The Adjacent Wall.   Flush Fitting 1200Mm Long Cross Tees To Be Interlocked Between Main Runners At 600Mm Centre To Form 1200 X 600 Mm Module.  Cut Cross Tees Longer Than 600Mm Require Independent Support.  600 X 600Mm Module To Be Formed By Fitting 600Mm Long Flush Fitting Cross Tees Centrally Between The 1200 Mm Cross Tees.Perimeter Trim To Be Armstrong Wall Angles Of Size 3000X19x19mm, Secured To Walls At 450 Mm Maximum Centres.  Armstrong Suspension System Accessories Manufactured And Supplied By Armstrong World Industries Consisting Of M6 Anchor Fasteners With Vertical Hangers Made Of Galvanised Steel Of Size 26 X 26 X 25 X 1.2Mm With A Galvanised Thickness Of 80Gsm, A Pre Straightened Hanger Wire Of Dia €“ 2.5 Mm Of 1.8 M Length., Thickness Of 80Gsm And A Tensile Strength Of 344-413 Mpa, Along With Adjustable Hook Clips Of 0.8Mm Thick, Galvanised Spring Steel For 2.68 Mm With A Minimum Pull Strength Of 110 Kg. The Adjustable Clip Also Consists Of A 3.5 Mm Aquiline Wire To Be Used With The Main Runner. Entire Work Shall Be Carried Out As Per The Detailed Technical Specifications, Drawings And As Per The Instruction Of Engineer- In- Charge., Tile Based False Metal Ceiling In Server Room Providing And Fixing Of Armstrong Gi Lay In Plain Metal Ceiling Consisting Of 600X600mm Lay In Tiles Of Pre Coated Galvanized Steel In 0.5 Mm Thickness In Global White Color Tile To Be Laid On Armstrong Grid Systems With 15Mm Wide T - Section Flanges Color White Having Rotary Stitching On The Main Runner, 1200 Mm And 600 Mm Cross Tees. The Tiles Would Have Fire Performance Of Class A2-S1.D0 As Per En13501 Standard In Module Size Of 600 X 600 Mm Suitable For Green Building Application, With Recycled Content Of 25%. The Grid Should Be Of €Œarmstrong†Make With 15Mm Wide T - Section Flanges Color White Having Rotary Stitching On All T Sections I.E. The Main Runner With C3 Coupling, 1200 Mm And 600 Mm Cross Tees With Hardened Xl2 Clip Having A Web Height Of 38 Mm And A Load Carrying Capacity Of 14 Kgs / M. The T Sections Have A Galvanizing Of 90 Grams Per M2 With Pull Out Strength Of 100 Kgs. Suspension System For Armstrong Grid To Be Of Armstrong Make. The Tile And Grid System Used Together Should Carry A 10 Year Warrantee. Installation: To Comprise Main Runner Spaced At 1200Mm Centers Securely Fixed To The Structural Soffit Using Armstrong Suspension System ( Specifications Below ) At 1200Mm Maximum Centre. The First / Last Armstrong Suspension System At The End Of Each Main Runner Should Not Be Greater Than 450Mm From The Adjacent Wall. Flush Fitting 1200Mm Long Cross Tees To Be Interlocked Between Main Runners At 600Mm Centre To Form 1200 X 600 Mm Module. Cut Cross Tees Longer Than 600Mm Require Independent Support. 600 X 600Mm Module To Be Formed By Fitting 600Mm Long Flush Fitting Cross Tees Centrally Between The 1200 Mm Cross Tees. Perimeter Trim To Be Armstrong Wall Angles Of Size 3000X19x19mm, Secured To Walls At 450 Mm Maximum Centers. Armstrong Suspension System Accessories Manufactured And Supplied By Armstrong World Industries Consisting Of M6 Anchor Fasteners With Vertical Hangers Made Of Galvanized Steel Of Size 26 X 26 X 25 X 1.2Mm With A Galvanized Thickness Of 80Gsm, A Pre Straightened Hanger Wire Of Dia €“ 2.65 Mm Of 1.8 M Length., Thickness Of 80Gsm And A Tensile Strength Of 344-413 Mpa, Along With Adjustable Hook Clips Of 0.8Mm Thick, Galvanized Spring Steel For 2.68 Mm. The Adjustable Clip Also Consists Of A 3.5 Mm Aquiline Wire To Be Used With The Main Runner., Providing And Fixing Roller Blinds Of Following Specifications:The Drive Unit Shall Be Made Of Moulded Plastic With Steel Spring Support And Inserted Into The Tube And It Shall Be Driven By A Ball Chain Pulley With Ball Chain And Can Be Positioned At Right Side Or Left Side Of The Shade. The Shade When Lowering Or Raising, Shall Be Automatically Locked In Position Upon Release Of The Ball Chain By Means Of A Built-In Friction Lock.The End Plug Shall Be Moulded Of Plastic With A Steel Location Pin.The Plug Shall Be Inserted Into The Tube End. ( Opposite To The Drive Unit ) .The Support Brackets Shall Be Of Coated Steel And Provided With Covers And Used In Right Hand Positions Differentiated By The Acceptance Of The Rectangular Drive Unit Support Or The Round Idler Plug Pin.The Roller Tube Shall Be Of Extruded Aluminum With 38Mm Internal Diameter And Skin Thickness Of 1Mm And Shall Incorporate A Keyway Integral With The Tube To Accommodate The Spline. The Outside Diameter Of The Roller Tube Shall Be 40Mm.The Bottom Rail Shall Be A Stiffening Inserted Into Bottom Rod Pocket.The Material May Be Timber, Pvc Covered Steel Tube Or Vb Bottomrail.The Ball Chain Shall Be 2Mm Diameter Cord With 4.5Mm Diameter Acetal Balls Moulded Co-Axially To It On 6Mm Pitch To Form An Endless Ballchain Which Is Used For Raising Or Lowering Action Of The Shades. Etc, Complete As Per Manufacturers Specifications, Detailed Technical Specifications And As Per The Eic / Architect. The Fabric Shall Be As Per Selection From Hunter Douglas Or Vista Range And Shall Be Sized According To Site Requirements, Manufactured By Hunter Douglas Or Vista Make As Described Below:Providing And Fixing Translucent Roller Blind Fixed On Window Level On Wooden Batten And Curtain Lift With Cotton Thin Rope, Design And Colour As Per Instruction By Engineer €“ In €“ Charge With Necessary Hardware Fitting, Material And Labour Etc. Complete As Per Detail Drawing And Instruction Of Engineer-In Charge And Consultant. Approved Make Vista / Hunter Douglas / Neon Or Equivalent., Providing And Fixing 1.2 Thick S.S. 304 2B Grade Sheet With Nitric Acid.Process Etching Plate And All Text Andgraphics Fill-Up By Standard Enemel Black Colored. Fitted With Flats Ss Etching Plat Should Be Mounted On Wall / Wooden Surface By Ss Screws And / Or By 3M Double Side Gum-Tape, And Where Applicable As Per Companys Guideline, With Prior Approval By Architect Or On-Site-Authorised Person. Size :300X75mm ( Used In All Chambers / Door ) , Providing And Fixing 1.2 Thick S.S. 304 2B Grade Sheet With Nitric Acid.Process Etching Plate And All Text Andgraphics Fill-Up By Standard Enemel Black Colored. Fitted With Flats Ss Etching Plat Should Be Mounted On Wall / Wooden Surface By Ss Screws And / Or By 3M Double Side Gum-Tape, And Where Applicable As Per Companys Guideline, With Prior Approval By Architect Or On-Site-Authorised Person. Size: 250X150mm ( Used For Basic Signage ) , False Flooring Providing And Fixing Of Flexi Access Floor 800 Grade 1.2Mm High Pressure Laminated 600X600x30mm Tiles By Steel Welded Construction, With An Enclosed Bottom Pan With Uniform Pattern Of Modular Pockets Of 64 Hemispherical Conesâ Using Pedestal Construction With Base Plate: 100Mm X 100Mm X 2Mm Thickâ  Top Plate : 75Mm X 75Mm X 3Mm Thickâ  Toâ  Be Screwed To The Stringerâ  Of Size 15X28x0.8Mmx570mm With Screws Of Size M6x45mm To Carry Uniform Distributed Load Appx 1400Kgs Per M2 Andâ  All Steel Construction Coated With Anticorrosive Zinc Coating And Fire Rating: Class Inchoinch As Per The Company Specifications Complete., P And L 24Inch X 24Inch Vitrified 8 To 10 Mm Thick Tile Flooring Over 20 Mm ( Average ) Base Of Cement Mortar 1:6 ( 1 Cement: 6 Coarse Sand ) On New Surface Or Fixing On Existing Flooring By Adhesive Material Including Dismentaling Of Existing Flooring And Jointed With Color Cement Slurry Including Finised With Flush Pointing And Cleaning The Surface Etc. Complete, Providing And Laying 24Inch X 24Inch Vitrified 8 To 10Mm Thick Tile In Skirting, Risersand Treads Of Steps, Landing And Dedo Laid On A Bed Of 12Mm Thick Cement Mortar 1:3 ( 1-Cement : 3-Coarse Sand ) Finishing With Flush Pointing In White Cement., Supplying Andlaying Of Floor Protection Sheet On Flooring Of Size 1800Mm X 1200Mm X 2Mm Thick, Adhesive Tap Shall Be Fixed Between Two Sheet, As Per The Instruction Of Eic / Architects. Contractor Has To Remove The Same After Completion Of Work / Hand Over The Site. Cost Is Inclusive Of All The Connected Works From Supply, Laying To Removing, Cleaning, Disposing Debris To An Unobjectionable Place, Etc., Supplying And Fixing 3M Sparkel Film On Glass With Manufacturer Specification, As Per The Detailed Technical Specifications, Drawings And As Per The Instructions Of Engineer- In- Charge., Wall Painting ( Three Coats ) With Plastic Emulsion Paint Of Approved Brand And Manufacture On Undecorateed Wall Surface To Give An Even Shade Including Throughly Brushing The Surface Free From Mortar Droppings And Other Foreign Matter And Sand Papered Smooth. Rates Including Cost Of Providing And Applying Primer And Putty., Soft Board Providing And Fixing Notice Board Made Out Of 12Mm Thick Soft Board With Good Quality Of Fabric And Wooden Framing Finish With Melamine Polish. Complete With All Necessary Hardware., Fire Proof / Toughened Glass In Server Room Providing And Fixing Window For Server Room , Made From 12Mm Th. Toughened Glass With 3Inchx1.6Inch Gasket Alluminium Frame And With All Necessary Hardware. G.C Series With Epdn Gasket Etc. Complete With Alualfa Or Equivalent Good Quality Etc.Complete As Per The Requirement Of The Architect., Acoustic Wall Paneling. Providing And Fixing Acoustical Wall Paneling With Using Ecotone Ultra Metal Frame Work Or Equivalent To Be Fixed On Wall At Every 600Mm Horizontally And 1200 Mm Vertically Fixed With The Help Of Metal Cleat By Using Ic-91 Which Is Screw Fixed Directly To The Wall And Fixing Cs 55 On Ic91 With Help Of Clip / Screw And Where Ever Required And Using Knauf Make Insulation Glass Wool Between Framing And Panel With Technical Specification Of 48 Kg / M3 And 50Mm Thick On Above Cs55 Fixing Acoustic Board Of Size 1200 X 600 X 15Mm Fix On Cs55 And Then Fixing 6Mm Thick Ply Wood Of Size 50Mm Than Fixing Vinyl Grippers Of Ecotone Or Approved Equivalent Make Eg 15 Griper System Using, Tracks ( Perimeter Track, Half Wrap, Mid Seam Whatever Is Required ) . Vinyl Grippers Must Have Base Tapes For Better Grip. Fixed In Between Vinyl Grippers And Sonido Board Pasting Ecotone Synco Pf Of 10X10mm Thick On The Acoustical Panel By Using Adhesive As Per Specifications Of Manufacturer. Fabric Stretching Supplying And Laying Fr Grade Fabric Stretch Clara Fabric Shade Vide Catalogue Name Brass / Atom Is Then Cut Into Required Size And Shape And Stretched, Inserted Inside The Gripper By Using Tools Recommended By Manufacturer, By Architect And As Specified Including All Accessories, Material And Labour Complete As Directed By Architect / Engineer–In–Charge., Providing And Fixing In Position Fully Glazed Paneled Coloured Anodized Aluminium Single / Double Leaf / Sliding Door Standard Section ( Jindal Or Equivalent ) For Frame 63.50 Mm X 49.50 Mm @1.15 Kg / M And Shutter Top Rail And Styles Size 47 Mm X 44 Mm Wt @ 0.88 Kg / M, Bottom Rail Size114 Mm X 44Mm Wt @1.36 Kg / M And Lock Rail Size 83 Mm X 44 Mm @ Wt 1.13 Kg / M And Glazing Clips Size 19 Mm X17 Mm Wt @ 0.12 Kg / M With 5 Mm Thick Frosted Or Obscured On One Side Glass ( Modi Float Or Saint Gobain Brand Or Equivalent ) Top Panel Including Rubber Gasket And 5 Mm Thick Laminated Compact Sheet At Bottom Panel Fix By Glazing Clips Including Providing Anodized Aluminium Handle And Stopper, Aldrop And Mortise Lock, Ss Screw With Fixture And Fastening Including Cutting The Flooring, Making Good Etc. All Required Materials Labours And Equipments With Fixing As Per Detailed Drawing Or As Directed Engineer In Charge., Providing And Fixing With Wooden Panel Malamine Polishe Beading As Directed By The Eic / Architect, Providing And Applying On Wooden Panel Malamine Polishe Beading As Directed By The Eic / Architect, Pelmet -Providing And Fixing Pelmet Made Out Of 18Mm Ply Of Size 150 X 200Mm Painted Black With Provision For Fixing Of Motorized Projection Screen Recessed In Ceiling. With 1.0Mm Laminate Finish, Removing Of Existing Aluminum Section And Handing Over The Same To Client, Dismentaling Tiled Of Stone Floors Laid In Mortar Including Stacking Of Serviceable Materilas And Disposal Of Unserviceable Materials With All Lead And Lift., Providing And Fixing White Board Also Knows As Marker Board, Dry -Erase Board, Pen Board As Per Size Specified Area In Drawing Detail As Architect Approved.Made Out Of Laminated Chipboard, High-Pressure Laminates And Steel Board With White, Usually Polyester Or Acrylic, Coating.All Suppliying , Fixing As Per Detail Design, Shape As Showing In Drg No ( 0 ) , Over All Brifing As Above.The Rate Are Including With All Material, Labour, Wastge And Complete As Directed By Eic., Makes And Model For Swicthgears, Lt Switchgear ( Acb ) :- Schnieder €“ Nw Masterpact 6.0P Release, Siemens €“ 3Wl With 76B Release, Legrand 1. Acb Shall Have The Breaking Performance Ics = Icu = Icw ( 1Sec ) = 50Ka 2. All Acbs Shall Be Supplied With Both Side Vertical Terminal Adaptors For Better Heat Dissipation. 3. All Breaker Shall Have Basic Trip Unit Communicable. Zsi Should Be Standard Feature In All Acb’S 4. All Dg Sync Acb Should Have Harmonics Monitoring Release. 5. Dg Set I / C And Transformer I / C H Type. 6. Acbs Shall Have Minimum 4 Change-Over Auxiliary Contacts, Available To Be Used For Indication And Interlocking, Rated At Minimum 10A 240 / 380V 50 Hz And Shall Be Wired On Chassis / Cradle. There Should Be Facility To Add One More Set Of 4 Contacts If Required. Lt Switchgear ( Mccb ) :- Mp And Tm Legrand €“ Dpx3 / Schnieder - Cvs / Siemens €“ 3Va. Lt Switchgear ( Mcb ) :- Legrand - Dx3 / Schnieder €“ Acti 9 / Siemens - 5Sl ( 10Ka ) . 1. B Curve Mcb Shall Be Quoted For Resistive Loads. 2. C Cuve Mcb Shall Be Quoted For Slightly Inductive Loads. 3. D Curve Mcb Shall Be Quoted For Small Motroised Loads, Ups, Pumps Etc. Refer Sld For The Same. Supply, Installation, Testing And Commissioning Of Indoor Main Lt Panel For Corporate Office As Per Specification, Technical Data Sheet And Make List.Refer Single Line Diadram-For Main Lt Panel., Makes And Model For Swicthgears, Lt Switchgear ( Acb ) :- Schnieder €“ Nw Masterpact 6.0P Release, Siemens €“ 3Wl With 76B Release, Legrand. 1. Acb Shall Have The Breaking Performance Ics = Icu = Icw ( 1Sec ) = 50Ka. 2. All Acbs Shall Be Supplied With Both Side Vertical Terminal Adaptors For Better Heat Dissipation. 3. All Breaker Shall Have Basic Trip Unit Communicable. Zsi Should Be Standard Feature In All Acb’S. 4. All Dg Sync Acb Should Have Harmonics Monitoring Release. 5. Dg Set I / C And Transformer I / C H Type. 6. Acbs Shall Have Minimum 4 Change-Over Auxiliary Contacts, Available To Be Used For Indication And Interlocking, Rated At Minimum 10A 240 / 380V 50 Hz And Shall Be Wired On Chassis / Cradle. There Should Be Facility To Add One More Set Of 4 Contacts If Required. Lt Switchgear ( Mccb ) :- Mp And Tm Legrand €“ Dpx3 / Schnieder - Cvs / Siemens €“ 3Va. Lt Switchgear ( Mcb ) :- Legrand - Dx3 / Schnieder €“ Acti 9 / Siemens - 5Sl ( 10Ka ) . 1. B Curve Mcb Shall Be Quoted For Resistive Loads. 2. C Cuve Mcb Shall Be Quoted For Slightly Inductive Loads. 3. D Curve Mcb Shall Be Quoted For Small Motroised Loads, Ups, Pumps Etc. Refer Sld For The Same. Supply, Installation, Testing And Commissioning Of Indoor Ups Panel For Corporate Office As Per Specification, Technical Data Sheet And Make List.Refer Single Line Diadram., Makes And Model For Swicthgears, Lt Switchgear ( Acb ) :- Schnieder €“ Nw Masterpact 6.0P Release, Siemens €“ 3Wl With 76B Release, Legrand. 1. Acb Shall Have The Breaking Performance Ics = Icu = Icw ( 1Sec ) = 50Ka. 2. All Acbs Shall Be Supplied With Both Side Vertical Terminal Adaptors For Better Heat Dissipation. 3. All Breaker Shall Have Basic Trip Unit Communicable. Zsi Should Be Standard Feature In All Acb’S. 4. All Dg Sync Acb Should Have Harmonics Monitoring Release. 5. Dg Set I / C And Transformer I / C H Type. 6. Acbs Shall Have Minimum 4 Change-Over Auxiliary Contacts, Available To Be Used For Indication And Interlocking, Rated At Minimum 10A 240 / 380V 50 Hz And Shall Be Wired On Chassis / Cradle. There Should Be Facility To Add One More Set Of 4 Contacts If Required. Lt Switchgear ( Mccb ) :- Mp And Tm Legrand €“ Dpx3 / Schnieder - Cvs / Siemens €“ 3Va. Lt Switchgear ( Mcb ) :- Legrand - Dx3 / Schnieder €“ Acti 9 / Siemens - 5Sl ( 10Ka ) . 1. B Curve Mcb Shall Be Quoted For Resistive Loads. 2. C Cuve Mcb Shall Be Quoted For Slightly Inductive Loads. 3. D Curve Mcb Shall Be Quoted For Small Motroised Loads, Ups, Pumps Etc. Refer Sld For The Same. Supply, Installation, Testing And Commissioning Of Indoor Change Over Switch As Per Specification, Technical Data Sheet And Make List.Refer Single Line Diadram, Providing And Making Point Wiring In Surface / Concealed In Slab, Walls, Furnitures And For Above False Ceiling, Or On Ceiling, On Beams Shall Be Fixed With Saddles And Spacers Etc., With Conduits Taken In / On Slab With 25 Mm Dia., 2Mm Thick Fr Medium Duty Pvc Rigid Fia Approved Isi Marked Conduits With Bends, Tees, Elbows, Junction Boxes Etc., With 650 / 1100 V Grade Isi Marked Pvc Insulated Frls Copper Conductor Wires I.E. Multi-Stranded Flexible Type Single Pvc Insulated Copper Conductor Wires All Accessories Screws And Washers, Modular Series Switches With All Accessories Such As 5 Amp, 5 Pin, Socket, One Or Two Way Switch All Mounted On Modular Cover Plate With Flush Company Made Metal Box And Outlet Box Of 18 Swg Gi With Its Accessories, Angle Holder / Batten Holder / Ceiling Rose, 3 Mm Thick Hylam Cover Plates For Outlet Box Etc., Electrical Point To Be Complete In All Respect To The Satisfaction Of E.I.C. The Rates Shall Be Exclusive Of Mains. Cost Of Mcb Shall Not Be Considered In Point Rate. Wire Size For Circuit :- Wire Size From Ldb To Sb :Phase And Neutral : 2.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Wire Size From Sb To Sb : Phase And Neutral : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Wire Size From Sb To Light : Phase And Neutral : 1.0 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Wire Size From Sb To Fan, Exhaust Fan : Phase And Neutral : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Wire Size From Ldb To Ac, Geyser. : Phase And Neutral : 4 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 2.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Offwire Size = 2.5 Sqmm ( P+N+E ) . Wire Size From Ldb To 16 A Socket : Phase And Neutral : 2.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . The Backbox Shall Be Of Same Make As Switch Accessories. Mcb Operated Light Points For Common Area ( Ground Floor, Stair , Foyer ) . Wire Size From Db To Light : Phase And Neutral : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Ldb To Light Light Point. Point To Points. Primary Light Points Controlled By One 10 A Mcb Andrequired All Type Of Accessories To Complete The Job., Providing And Making Point Wiring In Surface / Concealed In Slab, Walls, Furnitures And For Above False Ceiling, Or On Ceiling, On Beams Shall Be Fixed With Saddles And Spacers Etc., With Conduits Taken In / On Slab With 25 Mm Dia., 2Mm Thick Fr Medium Duty Pvc Rigid Fia Approved Isi Marked Conduits With Bends, Tees, Elbows, Junction Boxes Etc., With 650 / 1100 V Grade Isi Marked Pvc Insulated Frls Copper Conductor Wires I.E. Multi-Stranded Flexible Type Single Pvc Insulated Copper Conductor Wires All Accessories Screws And Washers, Modular Series Switches With All Accessories Such As 5 Amp, 5 Pin, Socket, One Or Two Way Switch All Mounted On Modular Cover Plate With Flush Company Made Metal Box And Outlet Box Of 18 Swg Gi With Its Accessories, Angle Holder / Batten Holder / Ceiling Rose, 3 Mm Thick Hylam Cover Plates For Outlet Box Etc., Electrical Point To Be Complete In All Respect To The Satisfaction Of E.I.C. The Rates Shall Be Exclusive Of Mains. Cost Of Mcb Shall Not Be Considered In Point Rate. Wire Size For Circuit :- Wire Size From Ldb To Sb :Phase And Neutral : 2.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Wire Size From Sb To Sb : Phase And Neutral : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Wire Size From Sb To Light : Phase And Neutral : 1.0 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Wire Size From Sb To Fan, Exhaust Fan : Phase And Neutral : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Wire Size From Ldb To Ac, Geyser. : Phase And Neutral : 4 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 2.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Offwire Size = 2.5 Sqmm ( P+N+E ) . Wire Size From Ldb To 16 A Socket : Phase And Neutral : 2.5 Mm2 Cu Frls Flexible Wire ( 650 V ) ( P+N ) . Earth : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . The Backbox Shall Be Of Same Make As Switch Accessories. Mcb Operated Light Points For Common Area ( Ground Floor, Stair , Foyer ) . Wire Size From Db To Light : Phase And Neutral : 1.5 Mm2 Cu Frls Flexible Wire ( 650 V ) . Ldb To Light Light Point. Point To Points Secondary Light Points Controlled By One 10 A Mcb Andrequired All Type Of Accessories To Complete The Job., 6A Switch Operated Light Points Primary Light Points Controlled By One 6A Switch And Required All Type Of Accessories To Complete The Job. Including Wall / Ceiling Junction Box , With Lamp Holder On Wall Required All Type Of Accessories To Complete The Job., Secondary Light Points Controlled By One 6A Switch Andrequired All Type Of Accessories To Complete The Job., One Light Point Controlled By Two Way 6A Switch Andrequired All Type Of Accessories To Complete The Job., Bell Point With Connector Considering Off Wire With Required All Type Of Accessories To Complete The Job., 6A Socket With One 6A Switch On Switch Board / At Convenient Location With Cover Plate Andrequired All Type Of Accessories To Complete The Job. ( Only Switch Socket With Cover Plate Andrequired All Type Of Accessories ) , 16A Socket With One 16A Switch On Switch Board / At Convenient Location With Cover Plate Andrequired All Type Of Accessories To Complete The Job. ( Only Switch Socket With Cover Plate Andrequired All Type Of Accessories ) , One Fan Point Controlled By One 6 A Switch. The Cost Shall Include Supply Of Modular Type Fan Regulator Andrequired All Type Of Accessories To Complete The Job., 20A ( 6 Pin ) Switch ( 20 Amp Indicator Switch ) Socket ( For Ac ) With Flush Metal Box Of Company Made With Modular Cover Plate Complete Duly Concealed With All Necessary Terminations And Off Wiring From Switch Board To Plug Shall Be Consider In Abve Rate With Requrie 25 Mm Dia Size Of Conduit , Wire To Complete To The Satisfaction Of E.I.C, One Exhaust Fan ( 5A Plug Socket ) Point Controlled By 6A Switch And Mounting Plate With Necessary Accessories And Off Wiring From Switch Board To Plug Shall Be Consider In Abve Rate With Requrie 25 Mm Dia Of Conduit , Wire To Complete To The Satisfaction Of E.I.C. . Supply Of Exhaust Fan Shall Not Be Included., Supply, Installation, Testing And Commissioning Of Following Size Flexible Copper Frls Wire 660 V / 1.1 Kv Grade With Approved Make Pvc Insulated In Pvc Conduits , Pull Boxes , Hardware Etc. 2*1.5 Sqmm ( Pandn ) + 1*1.5 Sqmm ( E ) ( Sb To Sb ) , Supply, Installation, Testing And Commissioning Of Following Size Flexible Copper Frls Wire 660 V / 1.1 Kv Grade With Approved Make Pvc Insulated In Pvc Conduits , Pull Boxes , Hardware Etc. 2*2.5 Sqmm ( Pandn ) +1*1.5 Sqmm ( E ) ( Ldb To Sb ) , Supply, Installation, Testing And Commissioning Of Following Size Flexible Copper Frls Wire 660 V / 1.1 Kv Grade With Approved Make Pvc Insulated In Pvc Conduits , Pull Boxes , Hardware Etc.2*4 Sq.Mm ( Pandn ) +1*2.5 Sq.Mm ( E ) ( Ldb To Ac, ) , Supply And Laying Of Pvc Medium Duty Conduits In Slabs / Walls ( This Item Shall Be Operated Where Only Conduit Provision To Be Made No Wiring To Be Done ) For Cctv Cable. 25 Mm Dia Medium Duty Isi Pvc Conduit , Scope Include To Laying Gi Guard Wire In Empty Conduit., Supply, Installation Of T.V. Socket With Back Box, Harware Etc., Supply, Installation, Laying Of Tv Rg-6 Cable With Requrie Harware And Accessories Etc., Supply , Testing And Commissioning 4 Way Splitter With Wall Mount Boxes, Harware Etc., Supply And Laying Of Pvc Medium Duty Conduits In Slabs / Walls ( This Item Shall Be Operated Where Only Conduit Provision To Be Made No Wiring To Be Done ) . 20 Mm Dia Medium Duty Isi Pvc Conduit ( Elv ) , Scope Include To Laying Gi Guard Wire In Empty Conduit, Pull Boxes , Hardware Etc.., Sitc Of Inchweatherproofinch, For Outdoor Installation Jb Ip-66 Wall Mount / Floor Mount Juction Box With Terminals With Cable Glande With Multi-Level Knockouts For Cable Glands In Different Sizes, Cable Entry Also Possible From The Rear Side, Burning Behaviour In Glow Wire Test 960&Deg;C High Impact Withstand Ik 09 ( 10 Joule ) ( A ) 130X130x75 Mm Junction Box., Sitc Of Inchweatherproofinch, For Outdoor Installation Jb Ip-66 Wall Mount / Floor Mount Juction Box With Terminals With Cable Glande With Multi-Level Knockouts For Cable Glands In Different Sizes, Cable Entry Also Possible From The Rear Side, Burning Behaviour In Glow Wire Test 960&Deg;C High Impact Withstand Ik 09 ( 10 Joule ) ( B ) 130X180x75 Mm Junction Box., Supply, Installation, Testing And Commissioning Of 6 Way Double Door Type Tpn Lighting / Power Distribution Board ( Ip 20 ) As Per Following Specifications And Relevant Is. Incoming : 32 A Fp Mcb , 10 Ka, C-Curve. Outgoing : 3 Nos.25 A Dp Rccb, 4 Nos.10A Sp Mcb And 7Nos. 20A Sp Mcb , 10 Ka, C-Curve As Per Sld., Supply, Installation, Testing And Commissioning Of 8 Way Double Door Type Tpn Lighting / Power Distribution Board ( Ip 20 ) As Per Following Specifications And Relevant Is. Incoming : 40 A Fp Mcb , 10 Ka, C-Curve. Outgoing : 3 Nos.40 A Dp Rccb , 30Ma. 6 Nos.10A Sp Mcb And10 Nos. 20A Sp Mcb , 10 Ka, C-Curve As Per Sld., Supply, Installation, Testing And Commissioning Of 8 Way Single Door Type Spn Distribution Board ( Ip 20 ) As Per Following Specifications And Relevant Is. Incoming : 25 A Dp Rccb , Outgoing :6 Nos.6 / 10 / 16 / 20 / 25 A Sp / Dp Mcb , 10 Ka, C-Curve And Sp / Dp Automatic Multi Channel Timer Switch. Per Phase. ( As Per Sld ) , Supply, Installation, Testing And Commissioning Of 100A Fp Mccb , 25Ka With Ip65 Encloser With Required Accessories To Complete The Job., Supply, Installation, Testing And Commissioning Of 200A Fp Mccb , 35Ka With Ip65 Encloser With Required Accessories To Complete The Job., Supply, Installation , Testing And Commissioning Of Thermoplastic Type 3P, N, E, 16A, Power Plug With Top And 4P, 10Ka Mcb ( Inclined And Water Proof Type ) , Ip-67 With Hardware Etc., Supply, Installation , Testing And Commissioning Of Thermoplastic Type 3P, N, E, 32A, Power Plug With Top And 4P, 10 Ka Mcb ( Inclined And Water Proof Type ) , Ip-67 With Hardware Etc., Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 3.5C X 150 Sq. Mm Al Xlpe Armoured Cable., Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 4C X 16 Sq. Mm Al Xlpe Armoured Cable, Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 4C X 10 Sq. Mm Al Xlpe Armoured Cable., Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 4C X 4 Sq. Mm Cu Xlpe Armoured Cable., Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 3C X 4 Sq. Mm Cu Xlpe Armoured Cable, Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 4C X 16 Sq. Mm Cu Xlpe Armoured Cable., Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 4C X 10 Sq. Mm Cu Xlpe Armoured Cable, Supplying, Laying, Connection, Testing And Commissioning Of Heavy Duty Medium Voltage Cables As Per Specification And Is 7098 Part I, Xlpe Insulated, Inner And Outer Sheathed Pvc Type St-2 Fr Type, Armouring Single Layer Of Glavanized Flat Wires. Stranded Al Conductor Unless Or Otherwise Specified.The Cable Shall Be Laid As Per The Specification. Supply And Fixing Of Cable G I Clamps ( With Gi Screw ) , Nylon Tie, Brackets, Supports, Route Markers, Cable Tagging Etc. Where Ever Required To Fix The Cables Safely. Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative. The Cable Shall Have Outer Sheeth Of Xlpe And Inner Sheath Of Pvc With Stranded Al Conductor Wherever Specified. The Cable Shall Be Laid Underground In Hume Pipes / Dwc Pipe When Laid Outside The Building. Cable Shall Be Laid Throught Hume Pipes / Dwc Pipe / Cable Tray / Duct / Channel / Floor Trunks Etc When Laid Inside The Building. The Scope Shall Include: Supply Of Cables.Delivery Of The Cables At Site.Unloading At Site Store.Shifting Of Cable From Site Store To Place Of Installation.Connection Of Cable.Supply And Fixing Of Cable Clamps, Brackets, Supports, Route Markers Etc. Where Ever Required To Fix The Cables Safely.Earthing The Glands And Armouring With Earthing Clamp And Jumper And Also Connecting To Common Earth Bar.Testing Of Insulation And Continuity Of Cable And Submission Of Reports To The Clients Representative.To Prepare Submission Drawing And To Take Approval Of Consultant At Each Stage.To Prepare And Submit As-Built Drawing And Handing Over Document To End User.Measurement Of Cable Should Be Done By Contractor At Site And Submit Report To Clients Representative Before Purchasing / Procurment The Cable. 4C X 6 Sq. Mm Cu Xlpe Unarmoured Cable, Cable End Termination And Connection : Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Bimetalic Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker Or Panel Board Terminal / Connector To Connect More Than One No. Of Parallel Cables Or To Connect Higher Size Cable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 3.5C X 150 Sq. Mm Al Xlpe Armoured Cable, Cable End Termination And Connection : Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Bimetalic Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker Or Panel Board Terminal / Connector To Connect More Than One No. Of Parallel Cables Or To Connect Higher Size Cable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 4C X 16 Sq. Mm Al / Cu Xlpe Armoured Cable, Cable End Termination And Connection : Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Bimetalic Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker Or Panel Board Terminal / Connector To Connect More Than One No. Of Parallel Cables Or To Connect Higher Size Cable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 4C X 10 Sq. Mm Al / Cu Xlpe Armoured Cable, Cable End Termination And Connection : Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Bimetalic Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker Or Panel Board Terminal / Connector To Connect More Than One No. Of Parallel Cables Or To Connect Higher Size Cable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 4C X 16 Sq. Mm Al Xlpe Unarmoured Cable, Cable End Termination And Connection : Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Bimetalic Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker Or Panel Board Terminal / Connector To Connect More Than One No. Of Parallel Cables Or To Connect Higher Size Cable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 4C X 10 Sq. Mm Al Xlpe Unarmoured Cable, Cable End Termination And Connection : Supply, Fixing, Connection, Testing And Commissioning Of Double Compression Brass Cable Glands And Crimping Type Bimetalic Lugs / Sockets With Necessary Tools And Equipments As Specified In Specifications And Is. The Glands And Lugs / Sockets Shall Be Suitable For Cable Size And Type Mentioned Above. The Job Also Includes, If Necessary, Supply And Fixing Of Extension Busbar Of Same Material On Circuit Breaker Or Panel Board Terminal / Connector To Connect More Than One No. Of Parallel Cables Or To Connect Higher Size Cable To Lower Size Unit. The Job Also Includes Earthing The Glands And Armour Of The Cable With Common Earth Bar Or Flexible Copper Mesh. 4C X 6 Sq. Mm Cu Xlpe Unarmoured Cable, Supply, Installation, Assembling, Connection, Testing And Commissioning Of Fixtures Complete With All The Required Drilling, Welding, Cutting, Etc. To Install The Lighting Fixtures. Including All The Hardwares, Clamps, Cleat, Suspending Chains, Pipes, High Power Factor Improving Capacitor, Hf Electronic Ballast , Starters, Reflectors, Lamps, Suspension Rod And Hooks, Mounting Down Rod / Bracket / Steel Wire And Hook, All Work Should Be Done As Per Specification And Is. Scope Including Supply Of Necessary Clamp, Cleat, Connection Of All Parts, Fixing / Mounting Of Fixture On M.S Plate Of Purlin As Required To Complete The Job. Note : Housing Made Of Pressure Die Cast Aluminium Housing For Rapid Heat Dissipation ( Crca / Sheet Metal Not Acceptable / Not Acceptable Like Thin Polycarbonate Sheet Also Not Acceptable ) .All Light Fixture Will Have Super Low Loss Electronics Ballast With Pf≫0.85 And Thd ≪=15 % And Harmonics Within Permissible Limits Specified As Per Is / Standards. Fixtures Supplier Shall Provide 2 Years Replacement Warrenty For All The Products. Supply, Installation, Assembling, Connection, Testing And Commissioning Of Fixtures Complete With All The Required 2 Ft X 2Ft Grid 30 Watt Led Square False Ceiling , Min Ip 20 Classification With Min 100 Lumens / Watt., Supply, Installation, Assembling, Connection, Testing And Commissioning Of Fixtures Complete With All The Required Drilling, Welding, Cutting, Etc. To Install The Lighting Fixtures. Including All The Hardwares, Clamps, Cleat, Suspending Chains, Pipes, High Power Factor Improving Capacitor, Hf Electronic Ballast , Starters, Reflectors, Lamps, Suspension Rod And Hooks, Mounting Down Rod / Bracket / Steel Wire And Hook, All Work Should Be Done As Per Specification And Is. Scope Including Supply Of Necessary Clamp, Cleat, Connection Of All Parts, Fixing / Mounting Of Fixture On M.S Plate Of Purlin As Required To Complete The Job. Note : Housing Made Of Pressure Die Cast Aluminium Housing For Rapid Heat Dissipation ( Crca / Sheet Metal Not Acceptable / Not Acceptable Like Thin Polycarbonate Sheet Also Not Acceptable ) .All Light Fixture Will Have Super Low Loss Electronics Ballast With Pf≫0.85 And Thd ≪=15 % And Harmonics Within Permissible Limits Specified As Per Is / Standards. Fixtures Supplier Shall Provide 2 Years Replacement Warrenty For All The Products. Supply, Installation, Assembling, Connection, Testing And Commissioning Of Fixtures Complete With All The Required Ceiling Concealed / Recess Light , Min Ip 20 Classification With Min 100 Lumens / Watt., Supply, Installation, Assembling, Connection, Testing And Commissioning Of Fixtures Complete With All The Required Drilling, Welding, Cutting, Etc. To Install The Lighting Fixtures. Including All The Hardwares, Clamps, Cleat, Suspending Chains, Pipes, High Power Factor Improving Capacitor, Hf Electronic Ballast , Starters, Reflectors, Lamps, Suspension Rod And Hooks, Mounting Down Rod / Bracket / Steel Wire And Hook, All Work Should Be Done As Per Specification And Is. Scope Including Supply Of Necessary Clamp, Cleat, Connection Of All Parts, Fixing / Mounting Of Fixture On M.S Plate Of Purlin As Required To Complete The Job. Note : Housing Made Of Pressure Die Cast Aluminium Housing For Rapid Heat Dissipation ( Crca / Sheet Metal Not Acceptable / Not Acceptable Like Thin Polycarbonate Sheet Also Not Acceptable ) .All Light Fixture Will Have Super Low Loss Electronics Ballast With Pf≫0.85 And Thd ≪=15 % And Harmonics Within Permissible Limits Specified As Per Is / Standards. Fixtures Supplier Shall Provide 2 Years Replacement Warrenty For All The Products. Supply, Installation, Assembling, Connection, Testing And Commissioning Of Fixtures Complete With All The Required Wall / Ceiling Tube Light ( Mirroe Light / 2Ft Tube Light ) , Min Ip 20 Classification With Min 100 Lumens / Watt., Supply, Installation, Assembling, Connection, Testing And Commissioning Of High Speed 50 Watt Ceiling Fan With Double Ball Bearing Isi Mark With Condenser 230 Volt A.C. 50 Hz 1200 Mm Sweep Complete Having 3Blades With Aluminium Blades With , Canopy And 30 Cms. Down Rod Erected With 1.5Sq.Mm, 3 Core Flexible Wire With Earthing., Supply, Installation, Assembling, Connection, Testing And Commissioning Of Low Noise Decorative Exhaust Fan Having Size 200Mm With 1350 Rpm With Square Frame Abs Body With Inbuilt Lowers And Square Frame., Supply Installation Testing And Commissioning Of Cpri Tested Maintenance Free , Low Carbon Copper Coated Earth Rod Of 3 Metre Electrode Having Diameter Of 14.2 Mm With Copper Coating Thickness Of 250Micron Tested As Per Iec 62561-2 And Is Provided With Universal Clamp Made Of Ss To Connect Rod With Flat Conductor . Earth Conductivity Enhancing Compound Shall Be Of 25 Kg / Pit Tested As Per Iec 62561-7, Tclp Tested. The Above Arrangements Shall Be Provided With Heavy Duty Earth Chamber And Heavy Duty Rcc Cover Of 20 Ton Load Bearing Capacity To Ensure The Safety Of Earthing System. Refer Standard Earthing Detail Layout. Model No.:-Electrode- Obo Type No. 14 3000 Ccer Or Equivalent, Flat Conductor -Obo Type No. 14 25 Rtc .Or Equivalent, Earth Conductivity Enhancing Compound- Obo Type No.Oec 125 Or Equivalent, Heavy Duty Earth Champer Obo Type No.Ufe Or Equivalent., Supply, Installation, Testing And Commissioning Of Required Size ( 25 X 3 Mm ) Gi. Strip For Earthing Of Using Galvanised Iron Clamp With Long Lasting Bolt Anticorrosive For Connection. ( For Shaft ) , Supply, Installation, Testing And Commissioning Of Required Size ( 32 X 6 Mm ) Gi. Strip For Earthing Of Using Galvanised Iron Clamp With Long Lasting Bolt Anticorrosive For Connection. ( For Eq. Potential Bar To Earthing ) , Supply, Installation, Testing And Commissioning Of Required Size Equipotential Bar 50 X 10 Mm Gi ( 1000Mm Length ) With Long Lasting Bolt Anticorrosive For Connection.., Supply, Installation, Testing And Commissioning Of G.I. Perforated Type Cable Tray With Necessary Bends, Tees And Clamps For Fixing. All Material Shall Be Hot Dip Galvanized As Per Specification And Drg. ( 900 X 100X 2.5 ) ( L X H X W ) Mm. Wide With Cable Tray Support And Required All Type Of Accessories To Complete Job. Condition :- Ideal Condition , Support Required Mininum Every 1Mtr. Max Weight :- 41 Kg., Supply, Installation, Testing And Commissioning Of G.I. Perforated Type Cable Tray With Necessary Bends, Tees And Clamps For Fixing. All Material Shall Be Hot Dip Galvanized As Per Specification And Drg. ( 600 X 100X 2.5 ) ( L X H X W ) Mm. Wide With Cable Tray Support And Required All Type Of Accessories To Complete Job. Condition :- Ideal Condition , Support Required Mininum Every 1Mtr. Max Weight :- 27 Kg., Supply, Installation, Testing And Commissioning Of G.I. Perforated Type Cable Tray With Necessary Bends, Tees And Clamps For Fixing. All Material Shall Be Hot Dip Galvanized As Per Specification And Drg. ( 300 X 75 X 1.5 ) ( L X H X W ) Mm. Wide With Cable Tray Support And Required All Type Of Accessories To Complete Job. Condition :- Support Required Mininum Every 1Mtr. Max Weight :- 11 Kg., Warning Signs 415 Volts ( Acrelik Material ) ., Supply And Fixing Of Fire Bucket With Floor / Wall Mounting Stand And First Filling Of Sand., Supply And Fixing Of 4.5 Kg. Co2 Type Portable Fire Extinguisher With Necessary Clamps, Supports And Trolley., Supply Of First Aid Box ( Acrelik Material ) ., Supply And Fixing Of First Aid Chart In Glassed Wooden Frame, Supply And Laying Of 1.1 Kv Grade 1000 Mm Wide Rubber Insulating Mat At Each Substation / Meter Room., Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 50Mm X 38Mm X 1.6 Mm With One Compartments, Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 75Mm X 38Mm X 1.6 Mm With One Compartments., Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 100Mm X 38Mm X 1.6 Mm With One Compartments., Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 150Mm X 38Mm X 1.6Mm With Three Compartments., Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 225Mm X 38Mm X 1.6Mm With Three Compartments, Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 250Mm X 38Mm X 1.6Mm With Three Compartments, Supplying And Laying Under Floor Pregalvanised Corrosion Proof Rectangular Sheet Steel Cable Trunking Of 1.6 Mm Thick Having With Stand Point Load Up To 1.33 Ton And Free From Seepage Of Concrete Of Screed Water Having Following Size Of Dimensions And No Of Compartments ( W X D X T ) 300Mm X 38Mm X 1.06 Mm With Three Compartments, Floor Mounted Metal S.S. Outlet ( Under Floor Service ) Made Of High Quality Abs And Polyamide Materials With Trap Frame And Screw Less Ratchet Trap Lead With Screw Less Knob Reinforced With 2.5Mm Thick Pregalvanised Steel Plate Of Following Size. 250Mm X 250Mm X 60 / 75 Mm One Trap Three Compartment ( Metal Lead ) ., Floor Mounted Metal S.S. Outlet ( Under Floor Service ) Made Of High Quality Abs And Polyamide Materials With Trap Frame And Screw Less Ratchet Trap Lead With Screw Less Knob Reinforced With 2.5Mm Thick Pregalvanised Steel Plate Of Following Size. 300Mm X 300Mm X 60 / 75 Mm ( Metal Lead ) Three Compartments., Supply Of Air Cooled Ductable, Wall Mounted And Consealed ( Hat ) Type Split Units Suitable For Local 45 Deg.C. Ambient Conditions Compleete With Indoor Unit, Outdoor Unit With Scroll Compressors, In Built Electrical Control Box, Remote Controller Unit, First Charge Of Refrigerant Gas Etc. 11 Tr Ductable Split Unit With Scroll Compressors., Supply Of Air Cooled Ductable, Wall Mounted And Consealed ( Hat ) Type Split Units Suitable For Local 45 Deg.C. Ambient Conditions Compleete With Indoor Unit, Outdoor Unit With Scroll Compressors, In Built Electrical Control Box, Remote Controller Unit, First Charge Of Refrigerant Gas Etc. 1.5 Tr - 3 Star Wall Mounted Split Unit., Supply Of Air Cooled Ductable, Wall Mounted And Consealed ( Hat ) Type Split Units Suitable For Local 45 Deg.C. Ambient Conditions Compleete With Indoor Unit, Outdoor Unit With Scroll Compressors, In Built Electrical Control Box, Remote Controller Unit, First Charge Of Refrigerant Gas Etc. 2.0 Tr - 3 Star Wall Mounted Split Unit., Installation, Testing And Commissioning Of Ac Units At Site Including With Lifting, Shifting And Positioning At Site On Ms Fabricated Stand / Platform And Required Refrigerent Gas Charging And Canvass Connection. 11 Tr Ductable Split Unit With Scroll Compressors., Installation, Testing And Commissioning Of Ac Units At Site Including With Lifting, Shifting And Positioning At Site On Ms Fabricated Stand / Platform And Required Refrigerent Gas Charging And Canvass Connection., Installation, Testing And Commissioning Of Ac Units At Site Including With Lifting, Shifting And Positioning At Site On Ms Fabricated Stand / Platform And Required Refrigerent Gas Charging And Canvass Connection. 2.0 Tr - 3 Star Wall Mounted Split Unit., Hard And Soft Copper Piping With 18 Mm Thick Black Epdm Rubber Sleeve Insulated Copper Piping And Electrical Power And Control Cabling Between Indoor And Outdoor Units Per Unit Per Rmt Basis. The Entire Piping Shall Be Further Covered With Uv And Fire Resistant Glass Cloth Coating And Gi Sheet Metal Weather Protection Covers. 11 Tr Ductable Split Unit With Scroll Compressors, Hard And Soft Copper Piping With 18 Mm Thick Black Epdm Rubber Sleeve Insulated Copper Piping And Electrical Power And Control Cabling Between Indoor And Outdoor Units Per Unit Per Rmt Basis. The Entire Piping Shall Be Further Covered With Uv And Fire Resistant Glass Cloth Coating And Gi Sheet Metal Weather Protection Covers. 1.5 Tr - 3 Star Wall Mounted Split Unit, Hard And Soft Copper Piping With 18 Mm Thick Black Epdm Rubber Sleeve Insulated Copper Piping And Electrical Power And Control Cabling Between Indoor And Outdoor Units Per Unit Per Rmt Basis. The Entire Piping Shall Be Further Covered With Uv And Fire Resistant Glass Cloth Coating And Gi Sheet Metal Weather Protection Covers. 2.0 Tr - 3 Star Wall Mounted Split Unit, Gi Sheet Metal Ducting Work As Per Is : 655 Code Complete With Rubber Gasket, Galvanised Hardware, Gi Rod And Slotted Angle Supports, Anchor Bolts, Support Structure Including With Required Scafolding Work To Install The Ducts At Site. 24 G, Gi Sheet Metal Ducting Work As Per Is : 655 Code Complete With Rubber Gasket, Galvanised Hardware, Gi Rod And Slotted Angle Supports, Anchor Bolts, Support Structure Including With Required Scafolding Work To Install The Ducts At Site. 22 G, Powder Coated Aluminium Section Grilles / Diffusers For Supply, Return And Treated Fresh Air Distribution., Black Painted Aluminium Volume Control Damper For Supply Air Collars., Duct Thermal Insulation With 18 Mm Thick Closed Cell Epdm Rubber Duly Faced With Uv And Fire Resistent Glass Cloth Coating And Joints To Be Sealed With Pvc Tape., Duct Accoustic Insulation With 25 Mm Thick 48 Kg / Cum Density Fibreglass Boards, Rp Tissue Paper And 28 G Perforated Aluminium Sheet., Exposed Roof Underdeck Insulation With 50 Mm Thick Tf Quality Expanded Polystyrene ( Thermocole ) To Be Fixed With Gi Raul Plug, Srew Wahser And Gi Lasing Wires, C Pvc 6 Kg / Cm2 Rating Drain Piping Work With Water Trapes / Seals 25 Mm Dia., C Pvc 6 Kg / Cm2 Rating Drain Piping Work With Water Trapes / Seals 40 Mm Dia., Misc. Civil Work Like Wall Jurry, Civil Cut Outs, Wall / Slab Openings To Pass Ducts, Copper Pipes And Drain Pipes Including With Refinishing And Plastering Of The Same To The Original Finish., Supply, Installation, Testing And Commissioning Cctv Camera 2Mp Dom1 / 2.7Inch, 2.0 Megapixel, Progressive Scan, Cmos Lens 2.8Mm@F2.0 4.0Mm@F2.0 Dori Distance Lens ( Mm ) Detect ( M ) Observe ( M ) Recognize ( M ) Identify ( M ) 2.8 46.7 18.7 9.3 4.7 4.0 66.7 26.7 13.3 6.7, Supply, Installation, Testing And Commissioning Cctv Camera 2Mp Bullet 1 / 2.7Inch, 2.0 Megapixel, Progressive Scan, Cmos Lens 2.8Mm@F2.0 4.0Mm@F2.0 Dori Distance Lens ( Mm ) Detect ( M ) Observe ( M ) Recognize ( M ) Identify ( M ) 2.8 46.7 18.7 9.3 4.7 4.0 66.7 26.7 13.3 6.7, Supply, Installation, Testing And Commissioning Nvr ( Network Video Recorder ) Support Ultra 265 / H.265 / H.264 Video Formats, 8 / 16-Channel Input Support 1-Ch Hdmi, 1-Ch Vga, Hdmi At Up To 4K ( 3840X2160 ) Resolution, Hdmi And Vga Simultaneous Output, Up To 12 Megapixels Resolution Recording 2 Sata Hdds, Up To 10Tb For Each Hdd, Hard Disk 4 Tb, Rj 45 Io, Supply And Fixing Of Pvc Junation Box., Supply, Installation, Testing And Commissioning 4 Zone Fire Alaram Control Panel With 16X2 Character Lcd Display, Complies With Ul- 864 Nfpa-72 Standard.Approval: Ul Listed., Supply, Installation, Testing And Commissioning Photoelectric Smoke Detector With Microprocessor-Controlled, Self-Diagnostic Circuitry, Eliminating The Need For Burdensome Sensitivity Test Equipment.Nfpa 72 Standard. Approval: Ul Listed. Csfm Approved., Supply, Installation, Testing And Commissioningheat Detectoroperating Temperature: 32Of ( 0Oc ) To 100Of ( 38Oc ) , Humidity: Up To 95% Rh, Non Condensing Air Pressure: No Effect. Alarm Temp: 135Of ( 57Oc ) , Supply, Installation, Testing And Commissioning Ri ( Response Indicater ) , Supply, Installation, Testing And Commissioning Mcp ( Manual Call Point ) , Supply, Installation, Testing And Commissioninghooter Cum Strobe, Supply, Installation, Testing And Commissioning Battery Backup 12V6ah, Supply And Laying Of 2 Core X 1.5 Sq.Mm Frls Armoured Cable Red Colour., Supply, Installation, Testing And Commissioning Of Battery Backup 12V 7Ah, Supply And Fixiing Of Rj 45 Socket With Jack Cat-6 Keystone Utp- White Colour., Supply And Fixing Face Plate 4Quad ( Keystone Jack, Square ) , Supply And Fixiing Of Back Box For Single, Dual ( Cat 5E / Cat6 / Cat6a, Square ) , Supply And Fixing 2 Mtr Pathcord Cat6 Utp 24Awg Patch Cord:2M, Plug30u Snagless, Supply And Fixing 1 Mtr Patch Cord Cat6 Utp 24Awg Patch Cord:1M, Plug 30U Snagless, Sitc 24 Port Patch Panel ( Loaded ) Cat 6 Utp Keystone Type- 24 Port-Fully Loaded, Supply, Installation, Testing And Commissioning 42U Network Enclosure Frame-800X1000-Steel, Casters Set Of 4, Adjustable Levellers Set Of 4, 19Inch Reduced Channel - Loop Type, Glass Door-800-42U, Metal Door-800-42U-Vented, Side Panels-1000-42U-Vented , Mounting Hardware- ( Pack Of 20 ) Fhu With 4 Fan 360Cfm, Vertical Power Distribution Unit With 12 Xâ  5 / 15 Sockets Round Pin, 230 Volts Ac, 32  Amp With Plug, Vertical Cable Manager-42U-Loop, Horz. Cable Manager-1U-Loop., Supply, Installation, Testing And Commissioning Poe 24Bport Network Swith+4Sfp 24-Ports 10 / 100 / 1000Mbps Poe + 4-Ports Gigabit Sfp Smart Managed Switch, 193Watts, Supply, Installation, Testing And Commissioning 9U Rack, Supply, Installation, Testing And Commissioning 6 Port Liu, Supply, Installation, Testing And Commissioning 6 Port Liu Panel, Supply, Installation, Testing And Commissioning Sleve Sc Addaptor, Supply, Installation, Testing And Commissioning Fiber Cabme Om 3, Supply And Laying Of Cat-6 Cable In Prelaid Pvc Conduit., Supply And Laying Of 25Mm Mms Pvc Conduit With Saddale Wall Grip Screw And Accessories, Supply Installation And Commissioning Of Water Leak Detection System Panel, Sensor Cable, Hooter , Smps Power Supply, Battery Backup.Cables, Supply Installation And Commissioning Of Water Leak Detection System Panel, Transhuder, Cables, Stand, Etes

Key Value

Document Fees
INR 17700 /-
EMD
INR 400000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail