| 1 | Ceiling Fan 1200mm 48\" (Havells/USHA) Confirming to IS:374 |
| 2 | LED Tube Lights Batten Confirming to IS: 16102 Led Tube Light Neptune Silver 20 Watt |
| 3 | Electronics Fan Regulator(EME) Deluxe 120/280V |
| 4 | Ventilating Fans 250mm 10\" (Havells) |
| 5 | LED Flood Lights Confirming to IS:16101 LED Flood Light 45 Watt |
| 6 | Surface mounted CRCA LED Panel Confirming to IS : 16102 LED CRCA Panel 18W ECW 1x1 ft. |
| 7 | Concreting of 11Mtrs Lattice Structure / Swaged STP in 1:4:8 cc in 0.9x0.9x2.05mtrs cement plaster of parapet in 1:4 mix. |
| 8 | Guy Assembly complete with 7/10 SWG Stay Wire, 140x85 mm H.T Guy Insulator, 18mm diameter Stay Rod 1.8 mtrs Long with bow thimble, turn buckle & 300x300x6mm anchor plate |
| 9 | Concreting of H.T Guy Assembly in 1:4:8 cc in 0.40x0.40x1.05mtrs Pit. |
| 10 | G.I Earth Spike conforming to IS 227. |
| 11 | G.I Strips 35x6 mm of 1 Mtr length conforming to IS 227. |
| 12 | Danger Board 11000Volts |
| 13 | Anticlimbing Device GI Barbed Wire |
| 14 | GI Wire 8 SWG |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 16 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 17 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 100 mm X 100 mm X 60 mm deep |
| 18 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required 180 mm X 100 mm X 60 mm deep |
| 19 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch |
| 20 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet |
| 21 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch |
| 22 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet |
| 23 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 24 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cableetc. as required |
| 25 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 26 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required |
| 27 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 28 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 29 | Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required |
| 30 | Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I. wire, cross arms, insulators etc. as required. |
| 31 | Erection of ACSR conductor of 7/2.11 mm to 7/3.00 mm diameter including binding etc. as required. |
| 32 | Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres |
| 33 | Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |