| 1 | Upkeep of various Panels of Generator and it auxiliaries including IP & SP Bus Ducts, & It’s pressurization blower units, Rectifier Transformer, PT Cubicles, CT&PT, Marshalling boxes and Electrical laboratory etc., as per scope of work of 3x210MW ATPS, Anpara |
| 2 | Round the clock checking/maintenance including its cleaning of H2 -gas, Seal Oil, Stator Water System of 3x210 MW generator of ATPS Anpara for one month . |
| 3 | Bus separation from generator of all the three phases/ three neutrals, cleaning of seal off bushings and HV testing of buses and other works in attending stator earth fault of generator & their box up, of 3x210MW ATPS, Anpara |
| 4 | Replacement of rubber expansion bellows of phase/ neutral side of generator terminal. |
| 5 | Overhauling of cooling fans of IP bus duct. |
| 6 | Work on SP Bus ducts ofCW transformer/station transformer/ UAT. |
| 7 | Breakdown maintenance of Thyristor Cooling Fan/Excitation Transformer Cooling Fan. |
| 8 | Replacementof seal off bushingof phase/ neutral side of generator terminal. |
| 9 | Overhauling ofAC/DC seal oil pump/stator water pump as per scope of work |
| 10 | Cleaning/ Replacement offlexible Links of phase /neutral side of generator terminal as per scope of work |
| 11 | Overhauling of seal oil vapour fan and motor as per scope of work |
| 12 | Replacement of AC/DC seal oil pump/stator water pump as per scope of work |
| 13 | Testing of phase/ neutral side protection & metering CT\"s of 15.75KV side and its connected circuit installed in Generator , 3x210 MW, ‘A’TPS, Anpara (Sonebhadra), U.P., as per scope of work . |
| 14 | Testing of installed PTsof ratio 15.75/110KV andtesting ofprotection & metering CT\"s ofBoth UAT (6.6KV )and its connected circuit ofGenerator , 3x210 MW, ‘A’TPS, Anpara (Sonebhadra), U.P., as per scope of work. |
| 15 | Removal and Remounting of Old CTs withnew upgraded CTs ofGenerator, 3x210 MW, ‘A’TPS, Anpara (Sonebhadra), U.P., as per scope of work. |
| 16 | Removal and Remounting of Old PTswithnew upgradedPTs ofGenerator, 3x210 MW, ‘A’TPS, Anpara (Sonebhadra), U.P., as per scope of work. |
| 17 | Attending leakage in clarrified coolingline of stator water system |
| 18 | Work on seal Oil/ Stator water cooler of 3x210 MW Units of ‘A’TPS, Anpara as per scope of work. |
| 19 | Breakdown work of shifting of tube nest of cooler of stator water/ seal oil system by healthy tube nest of ‘A’TPS, Anpara as per scope of work. |
| 20 | Breakdown works of De-coupling & coupling of stator water pump / seal oil vacuum / seal oil pump with motor, of ‘A’TPS, Anpara as per scope of work. |
| 21 | Attending leakages from Generator gas cooler of ‘A’TPS, Anpara as per scope of work. |
| 22 | Replacement of defective Generator hydrogen gas cooler of ‘A’TPS, Anpara as per scope of work. |
| 23 | Replacement of Defective float valve of Expaintion tank of all 3 unitsof ‘A’TPS, Anpara as per scope of work. |
| 24 | Replacement of Defective float valve of Seal oil tank of all 3 unitsof ‘A’TPS, Anpara as per scope of work. |
| 25 | Aligment of primary water/seal oil pump/Vaccum Pump with AC/DC Motor as per standard procedure. |
| 26 | Removal of H2 Gas from Generator as per scope of work. |
| 27 | Filling of H2 Gas from Generator as per scope of work. |
| 28 | Detecting of Hydrogen gas leakage with the help of soap solution and attending minor gas leakage from entire Generator system |