| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-10-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-10-2021 |
| 2 | 06-10-2021 | BOQ | BOQ | 18-10-2021 |
| Sl. No. | Item Description |
| 1 | Taking down cement plaster / cast in situ terrazo of any description on brick walls or concrete surfaces etc. including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed by theEngineer-In-Charge. |
| 2 | M&L for 15mm thick rendering in cement mortar 1:4, on brick masonary or concrete surfaces of walls, finished even and smooth without using extra cement, all as specified. |
| 3 | M&L for 15mm thick rendering in cement mortar 1:6, on brick masonary or concrete surfaces of walls, finished even and smooth without using extra cement, all as specified. |
| 4 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.50 Sqm each complete all as specified and as directed by the Engineer-in-Charge |
| 5 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 Sqm but n exc 4.00 Sqm each complete all as specified and as directed by the Engineer-in-Charge. |
| 6 | S&F Pressed steel frames of 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,including providing & filling cement concrete Type C-0, 1:3:6 (12.5 mm graded aggregate) complete, as specified, supplied and fixed. |
| 7 | S&F factory made second class hardwood 35 mm thick Plain, framed, paneled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats |
| 8 | S&F Factory made second class hardwood 35 mm thick Glazed andskeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats |
| 9 | Supply and fixing factory made uPVC door frame made of uPVC. extruded sections having an overall dimension (extruded section profile) 42 x 50 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 Nos. stainless steel hinges 100 mm size fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge. |
| 10 | Supply, and fixing 30 mm thick factory made uPVC, door shutter made of styles and rails of a uPVC hollow section of size 60 x 30 mm and wall thickness 2 mm (± 0.2 mm), with inbuilt decorative molding edging on one side. The styles and rails mitred and jointed at the corners by means of M.S. galvanised / plastic brackets of size 75 x 220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25 x 20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100 x 30 mm and 2 mm ( + 0.2 mm) wall thickness fixed to the shutter styles by means of plastic / galvanised M.S. \"U\" cleats. |
| 11 | The shutter frame filled with a uPVC multichambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as specified by the manufacturer and as per directions of Engineer-in-charge.Make:-Fenesta or equivalent of make approved by GE |
| 12 | S&F 150mm long, aluminium anodised, barrel tower bolts, of extruded section, ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 13 | S&F 300 mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete. |
| 14 | S&F Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 15 | S&F Aluminium handles cast type anodised of size 125 mm long ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 16 | S&F 300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified and as directed by Engineer-in-Charge. |
| 17 | S & F floor door stopper 140 mm overall length of cover plate with aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed. |
| 18 | S&F Box Type Steel windows with tubular frame side hung shutters including projecting type hinges with steel handle, 100 mm long and steel peg stay, complete with glazing and gauged pannel and guard bars, dovetailed or welded & PCC 1:3:6 type C0 using 12.5 mm graded crushed stone aggregate for embedding of holdfast, complete all as shown in Drg No CEUZ / TD / 1269 / 2008 Sheet 1/3 to 3/3 Dated 31 Oct 2008 & directed by Engr-in-Charge.Note:- Measurement shall be carried out for outer dimension of frame & quoted rate shall be deem to include for glazed shutter, wire gauged shutter & guard bar. |
| 19 | S&F for Box type steel ventilators with bottom hung or top hung shutters including projecting type hinges with steel handle, 100mm long and steel peg stay, complete with glazing and gauged pannel and guard bars, dovetailed or welded including & PCC 1:3:6 type C0 using 12.5 mm graded crushed stone aggregate for filling in hollow portion & embedding of holdfast, complete all as shown in Drg No CEUZ / TD / 1269 / 2008 Sheet 1/3 to 3/3 Dated 31 Oct 2008 & directed by Engr-in-Charge.Note:- Measurement shall be carried out for outer dimension of frame & quoted rate shall be deem to include for glazed shutter, wire gauged shutter & guard bar. |
| 20 | S&F Stainless steel wire cloth0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples |
| 21 | M&L for 3 mm thick sheet glass, ordinary quality and glazing with oil putty / wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for 03 mm thick sheet glass, figured glass (Frosted), pin head type and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S & F 0.63 mm thick, Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with fixed with L-type or J-type or cranked hook and washers, in roofs etc. with grade of zinc coating 275 including dismantling of old asbestos cement (corrugated, semi corrugated) sheets complete all as specified and directed by Engineer-in-charge . |
| 24 | S&F 0.63 mm thick, Galvanised, plain mild steel sheeting fixed with fixed with L-type or J-type or cranked hook and washers, in roofs for ridge etc. with grade of zinc coating 275 including dismantling of old asbestos cement ridge all as specified and as directed by Engineer-in-charge |
| 25 | M&L for Mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, Tee, angle, channel or flat section) including distance pieces, cleats etc, conforming to Gde Fe 410-W Gde E-250 including dismantling old steel truss /scanting etc complete all as specified and directed. |
| 26 | M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified |
| 27 | M&L for Preparation of new wooden or wood basedsurfaces of any description not otherwise described over 10 cm in width or girth and painting with two coats of synthetic enamel paint over one coat pink primer complete all as specified and as directed by Engineer-in-Charge. |
| 28 | M&L for applying 2 mm thick cement base wall care putty on plastered surface of wall, and making the surface even & smooth for receiving distemper / paint of any description all as specified & directed. |
| 29 | M&L forpreparation ofnew plastered surfaces of wall and applying two coats ofoil bound distemper over one coat of primer all as specified and directed.Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid separately |
| 30 | M&L for Complete removal of existing treatment fromPlastered surfaces of walls including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc and applying two coats of oil bound distemper over one coat of primer complete all as specified and directed by Engineer-in-charge. Note:- Cement base wall care putty where ever directed will be applied and will be measured & paid separately |
| 31 | M&L for preparation ofnew plastered surfaces of wall and applying two coats of cement based paint over one coat of primer. |
| 32 | M&L for complete removal of existing treatment from the plastered, concrete wall surfaces and applying two coats of cement base paint, over one coat of primer, complete all as specified and directed. |
| 33 | M&L for 75 mm thick PCC 1:3:6, nominal mix, type C1, using 20 mm graded crushed stone aggregate as in plinth protection, laid in bays not exc 2 Sqm each, surface finished even and smooth without using extra cement including providing 6 mm wide joint & filling the samewith bitumen mastic filling comprising of one part of heated bitumen 85 / 25 or 80/100 grade and three part of sand by weight, complete all as specified & directed. |
| 34 | Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge. |
| 35 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1: 6, using old size bricks complete all as specified and as directed by Engineer-in-Charge. |
| 36 | S&F aluminium powder coated (minimum thickness of powder coating 50 micron) snap grid frame work of T section (main & cross member) of size 25 mm x 25 mm x 1.5 mm thick in square pattern of grid size 600 mm X 600 mm . The aluminium fram work will supported on side wall with the used of aluminium \"L\" section of size 25 mm x 25 mm x 1.5 angles etc. Snap grid shall be supported with hangers of 4 mm dia. Galvanised iron wire adjusting level fixed to roof slabs / truss etc by means of ceiling cleats made out of Galvanised iron flat of size 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specifieddirected by the Engineer-in-Charge. |
| 37 | M&L for Non asbestos fiber cement building boards, manufactured from homogeneous mixture of cement, quartz and cellulose and cured with high pressure steam using auto claving process confirming to IS-14862, of size 600 mm x 600 mm x 4 mm thickin ceiling fixed to existing snap grid as per manufacturer instruction, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Demolition of floor, hearth or wall tiling or stone slab laid, bedded & pointed in any mortar including demolition of cement mortar bedding or backing coat complete. |
| 39 | M&L 15 mm thick screed or bedding layer in cement mortar (1:6) for laying floor finishes, complete all as specified. |
| 40 | M&L 10 mm thick rendering / backing coat in cement mortar (1:4) to receive wall tiles, complete all as specified. |
| 41 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqmin floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match, all as specified. |
| 42 | All as per Item No 40 above but fixing of tiles on vertical surfaces such as skirting / dado etc complete all as specified and directed . |
| 43 | M&L for Coloured Glazed ceramic tiles of size 300 mm x 600 mm x 7 mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or colour cement to matchwith tiles complete. |
| 44 | M&L for Chequered cement concretetiles of size 30 cm x 30 cm x 25 mm thick, with white cement and pigments, factory made, rubber molded, glossy finish, as in floor / path, set & jointed in neat cement slurry and pointed in white cement with pigment to match the tiles complete all as spd & directed . |
| 45 | Taking up or down steel tubing and connections, 15mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Taking up or down steel tubing and connections, 20mm bore fixed on walls, floors or ceiling etc complete all as specified and as directed by Engineer-in-Charge. |
| 47 | M&L for 15mm bore tubes, \"medium grade\", galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified. |
| 48 | M&L for 20 mm bore tubes, \"medium grade\", galvanised, with all fitting; ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified. |
| 49 | Refixing old steel tubing retrieved vide item No 44 above and connections in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge. |
| 50 | Refixing old steel tubing retrieved vide item No 45 above and connections in new or old position on walls, ceiling or floors etc of size 15 mm bore after cleaning including provn of new fittings all as directed by Engineer-in-Charge. |
| 51 | M & L for Lagging to pipes 15mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh complete including taking down of old lagging if required all as specified and directed by Engineer-in-Charge |
| 52 | M & L for Lagging to pipes 20mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh complete including taking down of old lagging if required all as specified and directed by Engineer-in-Charge |
| 53 | S&F Rotational molded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down ofexisting tank, complete all as specified and as directed by Engineer-in-Charge. |
| 54 | S&F Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe20 mm dia (minimum weight 210 gms) complete all as specified and as directed by Engineer-in-Charge. |
| 55 | S&F in repairs for 15 mm size bib taps, cast copper alloy chromium plated, with capstan head, screwed down, screwed for iron pipe or for brass ferrule and fixed, all as specified. |
| 56 | S&F in repairs for 15 mm size angle cock, chromium plated fancy type, cast copper alloy, screwed down, high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, all as specified. |
| 57 | S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified and as directed by Engineer-in-Charge. |
| 58 | S&F brass chromium plated shower roses with or without swivel joints of size 125 mm, including fixing to steel pipe or union, complete all as specified. |
| 59 | S&F PVC connection 15 mm size, of length 450 mm, with PTMT nutscomplete all as specified and as directed by Engineer-in-Charge |
| 60 | S&F in repair 15 mm size basin mixer cast copper alloy chromium plated with capstan heads, half turn type, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe with 450 mm braided connection pipe (without pop-up)complete all as specified. |
| 61 | S&F in repair 10 litre capacityPVC valve less, Syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets and PVC flush pipe etc complete all as specified and directed. |
| 62 | Supply and fix in repair white vitreous China wash hand basin (Flat back) of size 550 x 400 mm fixed on and including new brackets complete including, 32 mm size brass chromium plated waste coupling, chain and plug andporcelainstopper complete. |
| 63 | Supply and fix in repairs white vitreous china squatting pan ‘ORISSA’ pattern of size 580mm x 440 mm white with integral foot rests with ‘P’ or ‘S’ trap, front or back inlet including all connection and provision of lime concrete base complete all as specified and as directed.. |
| 64 | S&F in repair Vitreous China urinal half stall type, white, with grating and union for discharge pipe and including waste pipe(excluding flushing cistern), complete including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinals to plugs including 60 mm long brass screws including brass chromium plated urinal spreader for fixing with 15 mm dia pipe all as specified and directed by Engineer-in Charge |
| 65 | S&F in repair stainless steel chromium plated grating 100 mm dia complete all as specified and directed. |
| 66 | S&F in repair stainless steel chromium plated grating 125 mm dia complete all as specified and directed. |
| 67 | S&Fin repair 32 mm size PVC waste pipe, flexible pipe complete all as specified and directed by Engineer in Charge. |
| 68 | S&F in repair 600 mm x 450 mm size bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers\"complete all as specified and directed by Engineer in Charge. |
| 69 | S&F in repair 25 mm Stainless steel curtain rod with stainless steel bracket and stainless steel finils, fancy type as approved by GE, as in curtain rodsincluding taking down the old curtains rods complete all as specified and directed by Engineer-In-Charge. |
| 70 | M&L for machine cut & machine polished kota stone slab 18 to 20 mm thick as in floor laid over and including 20 mm thick screed bed in CM 1:6, jointed with grey cement slurry mixed with colour pigment to match the shade of the slab, rubbing and polishing including demolition of old flooring complete. |
| 71 | All as per item No 69 above but fixing of kota stone slab on vertical surfaces such as skirting / dado etc over backing coat 10 mm thick in CM 1:4 complete all as specified and directed . |
| 72 | Labour only for rubbing & mirror polishing of kota stone flooringwith polishing machine complete all as specified and directed by Engr-In-Charge. |
| 73 | M&L for Mild steel wind ties for roof sheet of any description including securing bolts and dismantling of old wind ties complete all as specified and directed by Engr-In-Charge. |
| 74 | S & F in repair second class soft wood Weather boarding, clean sawn, thickness 20 mm to 25 mm and rebated on thick edge to give 20 mm laps and fixed in eaves board etc up to 15 metres height, complete all as specified and directed by Engineer-in-Charge. |
| 75 | M&L for Preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat ofpink primer complete all as specified and directed by Engineer-In-Charge. |
| 76 | Taking down copper / aluminium point wiring (light, fan, socket & power) complete incl fixtures and fittings such as switches, ceiling rose, pendent holders, regulators, sockets, light fitting etc and making good disturbed surface of wall, floor etc complete as specified and directed. |
| 77 | Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC rigid conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box of suitable size for modular type switch with cover plate & frame complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) |
| 78 | All as per item No 76 above but point wiring for one 5 / 6 Amps socket outlet on independent board controlled by one-way switch. |
| 79 | All as per item No 76 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch. |
| 80 | All as per item No 76 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 81 | S&F modular one way switch 6 Amp 240 volt marked light / fan suitable for one module etc complete as specified and directed. |
| 82 | S&F Modular 6 Amp 5 pin universal socket suitable for two module , 250 volts complete all as specified and directed. |
| 83 | S&F modular switch one way 16 Amps 240 volts suitable for one module complete as specified and directed. |
| 84 | S&F Modular 6 cum 16 Amp socketsuitable for two module , 250 volts complete all as specified and directed. |
| 85 | S&F modular step type two module fan regulator suitable for 120 watt 250 volts complete as specified and directed. |
| 86 | M&L for ceiling rose with three terminal as per relevant IS complete as specified and directed |
| 87 | Taking down carefully by unscrewing from fitting and fixtures such as ceiling fittings, bulk head fittings, tube light fittings etc all as specified and directed. |
| 88 | S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200 mm (approx) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified and directed by Engg –in-charge. |
| 89 | S&F in repair energy efficient LED tube light fitting with built in LED & integral LED driver 10 watt, channel housing & diffuser of length 600 mm (approx) with all accessories, fixing arrangement internally pre-wired,fixed in position & connecting complete all as specified and directed by Engg –in-charge. |
| 90 | S&F Energy saving new generation 20 W LED IP 65 bulkhead luminaries with opal diffuser etc complete as specified and directed by Engr-in-charge Make -C&S model No LTB20WLED or equivalent of make CG / Havells / Wipro |
| 91 | Taking down carefully main switch boards / MCB DBs by unscrewing fromcomplete and making good disturbed surface by walls etc. |
| 92 | S&F epoxy powder coated or polystyrene insulated material sheet metal enclosure factory made (double door)4 way TPN (VTP) suitable for MCCB DB\"s 415 Voltswith 200 Amps rated bus bar, neutral & earthing link bar, flush/surface mounting complete all as specified anddirected. |
| 93 | S&F epoxy powder coated or polystyrene insulated material sheet metal enclosure factory made (double door)12 way SPN suitable for MCB DB\"s 240 Voltswith 200 Amps rated bus bar, neutral & earthing link bar, flush/surface mounting complete all as specified anddirected |
| 94 | S&F MCBsingle pole and neutral ISI marked `C\" seriesworking on 240 volts 50HZ AC supply for incoming & out going controlling system of capacity63 Amps 10 KA breaking capacity etc all as specified and directed. |
| 95 | S&F MCBsingle pole ISI marked `C\" seriesworking on 240 volts 50HZ AC supply for incoming & out going controlling system of capacity63 Amps 10 KA breaking capacity etc all as specified and directed. |
| 96 | S&F MCBsingle pole ISI marked ISI Marked `C\" series working on 240 Volts 50 HZ AC supply for incoming and out goingcontrolling circuit of capacity 6-32 Amp breaking capacity 10 KA etc all as specified and directed. |
| 97 | S&F MCCB\"s with electronic earth leakage model 125 Amps lcs=100 % lcu 4 pole 16 KA thermal magnetic setting Ics 100% lcu 415 V 50 HZ |
| 98 | Taking down carefully aluminum sub main wiring complete of any type (batten / surface conduit complete and making good disturbed surfaces complete all as specified and directed. |
| 99 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 100 | Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke, drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling, complete.Note: (i) 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment. |
| 101 | Taking down ceiling fan / Exhaust fan carefully by (disconnecting electrical connections) of any make and size, dismantlingblades washing of body and blades with proper detergent and applying one coat synthetic enamel paint, opening of fan motor and greasing & oiling of ball bearing and bushes respectively, reassembling the fan motor and testing complete including replacement of connection wire with 1 Sqmm size copper conductor cable PVC insulated & PVC sheathed, refixing the fan in same position |
| 102 | Supply andfixin repair exhaust fan 300 mm sweep, 900 RPM, AC, 240 volts, metal body, fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable including taking down old fan & depositing in store yard of EIC complete. Make Havells / Bajaj / Crompton / Usha |
| 103 | Supply and fix ceiling fan of 1200 mm sweep compete with blades, down rod canopy etc including hanging in position and connecting with 3 core, 0.50 Sqmm copper conductor PVC insulated and PVC sheathed round cable from ceiling rose to fan including taking down old fan & depositing in store yard of EIC complete. Make Havells / Bajaj / Crompton / Usha |
| 104 | Supply and fix in repair metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 20 Amps, 250 V, C type. |
| 105 | Supply and fix storage type water heater 150 liters capacity vertical floor mounting type made out of CRCA outer body, stainless steel storage tank, titanium enameled heating element, thermostat, thermal cutout, glass wool, fixed on and including PCC platform as per manufacturer\"s instruction, connecting with water, electric supply and writing the MES No etc complete as specified and directed by EIC .Make:- Havells / Jaguar / Crompton / Recold |
| 106 | Supply, laying & testing XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable confirming to IS 1554, with aluminium multi stranded conductor 1100 volt grade of size 16 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, including taking down old cable complete.Note : Earth work, sand cushioning, cable cover shall be measured & paid separately. |
| 107 | Supply, laying & testing XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable confirming to IS 1554, with aluminium multi stranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, including taking down old cable complete.Note : Earth work, sand cushioning, cable cover shall be measured & paid separately. |
| 108 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc, n exc 10 Sqm on plan area and getting out in any type soil. |
| 109 | Returning, filling in including spreading leveling watering and well ramming in layer n.exc 25 cm thick using excavated soil all as specified and directed. |
| 110 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point all as specified and as directed. |
| 111 | M & L for sand filling in trenches for cable cushioning with clean dry fine sand, including gently punning around cable complete all a specified and directed.NOTE:- Punned thickness of sand will be measured and paid. ) |
| 112 | S&F 40mm dia bore mild steel galvanized iron tubes, \"light grade\" with all fitting and laid in trenches or fixed to pole or laid in floors for protection of cable complete all as directed |
| 113 | M&L for well burnt brick sub classB (old pattern) laid flat for cable protection, width parallel to cable complete all a specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy