}

Bids Are Invited For Dismantling Of Bcu - Scope Includes Dismantling Of Batch Controller Unit By Proper Removal Of All Cables From Bcu, Dismantling Of Existing Structural Frame Of Bcu And Stacked At The Designated Place Advice By Hpcl. , Instln And Comm-Kerala

Statutory Bodies & Commissions/Committees has published Bids Are Invited For Dismantling Of Bcu - Scope Includes Dismantling Of Batch Controller Unit By Proper Removal Of All Cables From Bcu, Dismantling Of Existing Structural Frame Of Bcu And Stacked At The Designated Place Advice By Hpcl. , Instln And Comm. Submission Date for this Tender is 13-10-2021. Coats and Jackets Tenders in Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

29346421
Corrigendum : Bids Are Invited For Dismantling Of Bcu - Scope Includes Dismantling Of Batch Controller Unit By Proper Removal Of All Cables From Bcu, Dismantling Of Existing Structural Frame Of Bcu And Stacked At The Designated Place Advice By Hpcl. , Instln And Comm
Open Tender
Indian
Kerala
13-10-2021

Tender Details

Bids Are Invited For Dismantling Of Bcu - Scope Includes Dismantling Of Batch Controller Unit By Proper Removal Of All Cables From Bcu, Dismantling Of Existing Structural Frame Of Bcu And Stacked At The Designated Place Advice By Hpcl. , Instln And Commng Of Bcu - Installation Of Bcu On Structural Frame Including Termination And Glanding Of All Cables And Power On The Bcu Under The Supervision Of Oem. , Dismantling Of Rit - Scope Includes Dismantling Of Rit ( Remote Interaction Terminal ) By Removal Of All Cables And Glands From Rit, Dismantling Of Existing Structural Frame And Stacked At The Designated Place Advice By The Hpcl , Instln And Commng Of Rit - Installation And Commissioning Of Rit ( Remote Interaction Terminal ) : Installation Of Rit On Structural Frame Including Termination And Glanding Of All Cables And Power On The Rit Under The Supervision Of Oem. , Dismantling Of Card Reader - Scope Includes Dismantling Of Card Reader By Removal Of All Cables And Glands From Card Reader, Dismantling Of Existing Structural Frame And Stacked At The Designated Place Advice By The Hpcl. , Instln&Commng Of Card Reader - Installation And Commissioning Of Card Reader On Structural Frame Including Termination And Glanding Of All Cables And Power On The Card Reader Under The Supervision Of Oem. , Dismantling Of Earthing Relay - Scope Includes Dismantling Of Earthing Relay By Removal Of All Cables And Glands From Earthing Relay, Dismantling Of Existing Structural Frame And Stacked At The Designated Place Advice By The Hpcl. , Instln&Commng Earthing Relay - Installation And Commissioning Of Earthing Relay On Structural Frame Including Termination And Glanding Of All Cables And Power On The Earthing Relay Under The Supervision Of Oem. , Dismantling Of Mfm Transmiter - Scope Includes Dismantling Mfm Transmiter By Removal Of All Cables And Glands From Mfm Transmiter. Dismantling Of Existing Structural Frame And Stacked At The Designated Place Advice By The Hpcl. , Installtion Of Mfm Transmiter - Installation And Commissioning Of Mfm Transmiter On Structural Frame Including Termination And Glanding Of All Cables And Power On The Mfm Transmiter Under The Supervision Of Oem. , Sup 2Px1.5 Sq Frls Signal Cable - Cable, Electrical, Armoured; Application:Signal & Communication; Voltage Rating:1100 V; Construction: Stranded7x0.53 Mm Dia; Material, Conductor:Tinned Copper; Material, Insulation :Extruded Pvc Type C; Material, Inner Sheath:Polyvinyl Chloride; Material, Outer Sheath:Polyvinyl Chloride; Standard / Frls:Frls; Material, Armouring:Galvanised Steel Wire; Colour:Black ( +Ve ) & Light Blue ( -Ve ) ; Number Of Cores: 2 Pair; Cross Section, Cores:1.5 Sq, Mm; Twisted Pair: Minimum 10 Twist Per Meter, Diameter, Galvanised Steel Wire: 1.6 Mm, Shielding: Aluminium Mylar Tape ( Individual And Overall ) , Screening: 100 % Coverage With 25 % Overlap, Conductor Standard: Is-8130, Insulation Standard: Is 5831, Inner Sheath: Frls Pvc / Black ( St-2 Is 5831 / Iec-502 ) , Outer Sheath: Frls Pvc 1.6 Mm Thickness / Light Blue ( St-2 Is 5831 / Iec-502 ) , Applicable Standard: Bs 5308 Part-Ii / 1986, Core Identification: As Per Oem / Hpcl Standard. , Sup 12Cx2.5 Sq Frls Power Cable - Cable, Electrical, Armoured; Voltage Rating:1.1 Kv; Material, Conductor:Annealed Stranded Copper ( Class-2 ) ; Material, Insulation:Extruded Pvc Type A; Standard / Frls:Frls Properties; Armouring:Galvanised Steel Flat Strip; Number Of Cores:12; Cross Section, Cores:2.5 Sq.Mm; Tce-5318A-B-733-207, As Per Standard: Is:3975, Conductor Material As Per Standard: Is:8130 / 84, Insulation Material As Per Standard: Is:5831 / 84, Type: Fxy ( P ) , Sup 4Cx1.5 Sq Frls Control Cable - Cable, Electrical, Armoured; Voltage Rating:1.1 Kv; Material, Conductor:Copper; Material, Insulation:Cross Linked Polyethylene; Material, Outer Sheath:Polyvinyl Chloride; Material, Armouring:Steel Round Wire / Steel Strip; Number Of Cores: 4 Core; Cross Section, Cores:1.5 Sq.Mm; Design Spec:Is:7098 ( Part-1 ) 1988, Standard:2Xwy / 2Xfy, Standard Class 2 Annealed, Cores Laid Up, Type St-2 Inner Sheath, Overall Extruded Frls Pvc Type St- 2 Outer Sheathed Cables, Low Voltage, Cores Of The Cables Upto 5 Cores Shall Be Identified By Colouring Of Insulation. Red, Yellow, Blue, Black And Grey.For Cables Having 6 Cores And Above, Be Identified With Prominent And Indelible Numerals On The Outer Surface Of The Insulation.Conductor Lay - Cores Lay Up With Non Hygroscopic Fillers, To Protect The Cables Against Rodent And Termite Attack, Suitable Chemicals Shall Be Added Into The Pvc Compound Of The Outer Sheath. Temperature Rise Of Conductor On Continuous Load 70 Deg Centigrade , Sup 2Cx1.5 Sq Frls Control Cable - Cable, Electrical, Armoured; Application:Control; Voltage Rating:1100 V; Construction:Stranded 7 X 0.43 Mm Dia; Material, Conductor:Tinned Copper; Material, Insulation:Low-Density Polyethylene; Material, Inner Sheath:Polyvinyl Chloride;Material, Outer Sheath:Polyvinyl Chloride; Standard / Frls:Frls; Material, Armouring:Galvanised Steel Wire; Colour:Black ( +Ve ) & Light Blue ( -Ve ) ; Number Of Cores:2 Core; Cross Section, Cores:1.5 Sq, Mm; Diameter, Galvanised Steel Wire: 1.6 Mm, Shielding: Aluminium Mylar Tape ( Overall ) , Screening: 100 % Coverage With 25 % Overlap, Conductor Standard: Is-8130, Insulation Standard: Is 6474, Inner Sheath: Frls Pvc / Black ( St-2 Is 5831 / Iec-502 ) , Outer Sheath: Frls Pvc 1.6 Mm Thickness / Black ( St-2 Is 5831 / Iec-502 ) , Applicable Standard: Is 1554 Part-I / 1988, Core Identification: As Per Oem / Hpcl Standard , Dismantling Of Cable Tray Up To 100Mm - Scope Includes Dismantling Of Existing Cable Tray Upto Size Of 100 Mm Along With Cover, Clamps And Bolts And Placed At Designated Placed Advice By Hpcl , Dismantling Of Cable Tray Up To 200Mm - Scope Includes Dismantling Of Existing Cable Tray Upto Size Of 200 Mm Along With Cover, Clamps And Bolts And Placed At Designated Placed Advice By Hpcl , Laying Of Cable Tray Up To 100Mm - Scope Includes Laying Of Either Supplied Or Free Issue Cable Tray Upto Size Of 100 Mm Along With Cover, Clamps And Bolts. , Laying Of Cable Tray Up To 200Mm - Scope Includes Laying Of Either Supplied Or Free Issue Cable Tray Upto Size Of 200 Mm Along With Cover, Clamps And Bolts , Dismantling Of Cables Up To 10 Sq.Mm - Scope Includes Dismantling Of Existing Cable Upto Total Size Of 10 Sq.Mm From Cable Tray Or Without Cable Tray, Jbs Or Any Other Equipment. , Dismantling Of Cables Up To 20 Sq.Mm - Scope Includes Dismantling Of Existing Cable Upto Total Size Of 20 Sq.Mm From Cable Tray Or Without Cable Tray, Jbs Or Any Other Equipment. , Dismantling Of Cables Up To 40 Sq.Mm - Scope Includes Dismantling Of Existing Cable Upto Total Size Of 40 Sq.Mm From Cable Tray Or Without Cable Tray, Jbs Or Any Other Equipment , Laying Of Cables Up To 10 Sqmm - Scope Include Laying Of Cable Either Supplied Or Free Issue Of Total Size Upto 10 Sq.Mm Along With End To End Termination And Glanding. , Laying Of Cables Up To 20 Sqmm - Scope Include Laying Of Cable Either Supplied Or Free Issue Of Total Size Upto 20 Sq.Mm Along With End To End Termination And Glanding. , Laying Of Cables Up To 40 Sqmm - Scope Include Laying Of Cable Either Supplied Or Free Issue Of Total Size Upto 40 Sq.Mm Along With End To End Termination And Glanding. , Sply&Fixg Frls Earthing Wire6 Sq.Mm - Supply And Fixing Of 6 Sq.Mm Copper Multistrand Frls Earthing Wire ( Green / Yellow ) . Its Include 4 Sq.Mm Copper Ring Lug Conf:1100 Volt Is 604 , Supply Of Dc Cable Gland 1 / 2 ( Od 15 To 18 ) - Cable Gland; Type:Flameproof / Weather Proof; Type, Cable:Light Duty; Mat, Glands:Stainless Steel 304; Sealing Area ( S ) :Double Compression; Ingress Protection:Ip 66; Size:12 Mm; Threaded, Fixing Component:Npt; Diameter, Od, Cbl I / S, Max:10 Mm;Diameter, Od, Cbl O / S, Max:15 Mm; Group Iic & Ccoe Certified , Supply Of Dc Cable Gland 3 / 4 ( Od 18 To 21 ) - Cable Gland; Type:Et, Flp-Wp, Double Compression; Classification, Hazard Areas:Group Iic & Ccoe Certified;Mat, Glands:Stainless Steel 304; Sealing Area ( S ) :Double Compression; Size:3 / 4 In , Supply Of Dc Cable Gland 1 ( Od 21 To 24 ) - Cable Gland; Type:Flameproof / Weather Proof; Type, Cable:Light Duty; Mat, Glands:Stainless Steel 304; Sealing Area ( S ) :Double Compression; Ingress Protection:Ip 66; Size:25 Mm; Threaded, Fixing Component:Entry Thread; Diameter, Od, Cbl I / S, Max:23Mm;Diameter, Od, Cbl O / S, Max:25.6 Mm; Group Iic & Ccoe Certified , Cable Termination Per Core - End Termination Of Any Cable With Double Compression Flp Gland And Crimping Sockets Complete In All Aspect. Payment Will Be Made Per Core Terminated. , Supply & Instl Of Anchor Bolt - Providing And Fixing Electroplated Steel ( Heavy Duty ) Mechanical Anchor Fasteners Of Hpcl Approved Make And Installed As Per Manufacturer’S Specification, Drawing And As Directed By Hpcl Eic. ( Indicative Quantity ) Hst M20 / 30 , Supply & Instl Of Gi Clamp Up To 2 - Providing And Fixing Of Galvanized Iron Clamps Support Size Up To 40 Mm To The Pipelines Leaving A Clearance From The Wall If Required As Advised By Engineer-In-Charge. This Will Be Paid Only When The Clamping Is Done Separately And No Pipeline Is Replaced. , Supply & Layig Of Gi Strip 50X6 Mm - Hot Dip Galvanized G.I. Earth Strips With Min 100 Micron Coating: 50Mm X 6Mm Gi. Strip , Supply & Layig Of Gi Strip 25X3 Mm - Supply, Laying, Connection & Testing Bare Earthling Conductor For Inter-Connecting The Earthing Stations And Various Equipment In Built Up Trenches, Walls / Ceiling, Buried In Ground Generally Or As Specified And Shown On The Drawing Complete With All Accessories 25X3 Gi Flat. , Dismn & Instln Of Main Frame - Scope Includes Dismantling Of 2Mx1.5 M Strututal Frame Provided At Each Bay Of Tt Gantry For Mounting Bcu, Rit, Card Reader & Other Junction Boxes Etc. Job Icludes Remoavl Of All Fixtures On The Frame, Dismantling Of Existing Structural Frame And Installation Of The Same At Designated Space Advised By Hpcl Eic With Anchor Bolt. , Instn & Comm. Rack Monitoring Unit - Installation Of Rack Monitoring Unit On Structural Frame Including Termination And Glanding Of All Cables And Power On The Rack Monitoring Unit Under The Supervision Of Oem. For Testing Of Rack Monitor Installed At Ttg For Overfill Protection System Used In Bottom Loading Tts. , Fabrication Of Steel Structure - Fabrication Of Structures And Plates ( Includingsupply ) : The Scope Of Job Includes Fabrication Of Structures ( Materials Aprovided By Hpcl ) , Erection, Installation, And Commissioning Of The Entire Structure As Required By Officer-In-Charge , Liasioning Job–W&M Stamping - Liasioning For Stamping And Re-Verification Of Flow Meters Form Weight And Measure Department. All Necessary Technical Support For Stamping / Calibration Of Flow Meters Shall Be Provided By Party. The Liasioning Charges Excludes The Actual Government Fee And Same Shall Be Paid By Hpcl , Dismantling Of Structure - Dismantling Of Mild Steel Structures. All Works For Dismantling Of Mild Steel Structures At Work Site At Ground Level And Upto 1.5 Meter Height, Handling, Hauling, Loading, Unloading, Transportation, Staking Upto 150 Meter From Work Site, All As Directed By Owner. Scope Includes All Consumables, Tools, Tackles, Equipment, Manpower, Supervision. , Galnding Of Cable 1 - Cable Glanding Upto 1 In Of Instrument Cablesscope Of Work:1. Services For Cable Glanding Upto 1 Inch.2. Material Hpcl Scope3. Payment Will Be Made As Per Cable Size I.E, , Galnding Of Cable 3 / 4 - Cable Glanding Upto 3 / 4 In Of Instrument Cablesscope Of Work:1. Services For Cable Glanding 3 / 4 Inch.2. Material Hpcl Scope3. Payment Will Be Made As Per Cable Size I.E, , Galnding Of Cable 1 / 2 - Cable Glanding Upto 1 / 2 Inch Of Instrument Cablesscope Of Work:1. Services For Cable Glanding 1 / 2 Inch.2. Material Hpcl Scope3. Payment Will Be Made As Per Cable Size I.E , Supply Of Cable Tray 200X50x2mm - Cable Tray; Type:Perforated; Material:Hot Dip Galvanized Iron; Dimension:200 X 50 X 2 Mm; With Cable Tray Cover Of 1.6 Mm , Supply Of Cable Tray 100X50x1.6Mm - Cable Tray; Type:N / A; Material:Galvanised Iron; Dimension:100 X 50 X 1.6 Mm; Pregalvanised, With Zinc Bath Concentration As Per Is 2629 With Cable Tray Cover Of 1.6 Mm. , Sup 6Px1.5 Sq Frls Signal Cable - Cable, Electrical, Armoured; Application:Signal Cable; Voltage Rating:1100 V; Material, Conductor:Annealed Bare Copper; Material, Insulation:Extruded Ldpe; Material, Inner Sheath:Extruded Pvc St2; Material, Outer Sheath: Extruded Frls Pvc St2; Standard / Frls:Frls; Armouring:Galvanised Steel Strip; Number Of Cores:6 Pair; Cross Section, Cores:1.5 Mm2; Cable Marking: Sequential Marking For Every Meter, Quantity Tolerance:+ / - 5%, Cable Type:Pairs, Number Of Strands:7, Conductor Type:Multi Strand, Insulation Material Standard:Is 5831 / 1985, Insulation Thickness, Min:0.5 Mm, Insulation Color:Blue & Black With Numbering, Number Of Twist / Meter:10, Individual Shielding Requirement:Yes. More Details As Given In Tender Document , Sup 3Cx2.5 Sq Frls Power Cable - Cable, Electrical, Armoured; Voltage Rating:1.1 Kv; Material, Conductor:Copper; Material, Insulation:N / A; Material, Inner Sheath:Extruded Pvc; Material, Outer Sheath:Frls; Armouring:Steel; Number Of Cores:3 C; Cross Section, Cores:2.5 Sq.Mm; Type: Ywy, With Stranded Conductor, Confirming To Is: 7098 Part-I And As Per Detailed Specification Of Tender Attachments. Total Quantity : 1

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-10-2021 13-10-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail