Repair Replacement Of Unsv Geysers Alongwith Connected Items At Various Md Otm Accn At Air Force Stn Gurgaon Under Age E M Af Gurgaon Of Ge Af Gurgaon- M&L For Taking Down Unsv Geyser Of 25 Ltr Capacity From Existing Position By Disconnecting Elect / Water Connectioions, From Any Position, Locations And Replacing The Following Unsv Parts As Mentioned Below: - 2 ( I ) S&F In Repairs Thermostat Suitable For 25 Ltr Storage Type Vertical Water Heater Isi Mark As Per Existing One Complete All As Specified And Directed. 3 ( Ii ) S&F In Repairs Led Indication Lamp Suitable For Geysers In Roud / Rectangular Shape Complete All As Specified And Directed. 4 ( Iii ) S&F In Repairs Geyser Assembly Suitable To Fix Thermostat, Heating Elements As Of The Existng Size Suitable For 25 Ltr Capacity Geyser Including Suitable Washers, Clamps With Bolts & Nuts Suitable For 06 / 09 Hole Complete All As Specified And Directed. 5 ( Iv ) S&F In Repairs Fusible Plug Suitable For 25 Ltr Capacity Geysers As Per Existing Complete All As Specified And Directed. 6 ( V ) Taking Down Unsv Bottom / Top Cover Plates ( 2 Haf ) And S&F With New Bottom / Top Cover Plates With Machine Coloumns Of Geyser 25 Ltr Capacity Complete All As Specified And Directed. 7 ( Vi ) S&F In Repairs Steel Water Tank Suitable For 25 Ltr Capacity Water Heater Vertical Type As Per Existing Model And Size Complete All As Specified And Directed. 8 ( Vii ) S&F Safety Plug Suitable For 25 Ltr Capacity Vertical Type Water Heater As Per Existing Model / Make Complete All As Specified And Directed. 9 ( Viii ) S&F In Replacement Of M S Heavy Duty Fabricated Frame Suitable For Holding Water Tank Of 25 Ltr Capacity Geyser, As Per Sample And Existng Shape And Size Including Suitable Hole For Mounting The Geyser Complete All As Specified And Directed.Note: Sample Can Be Taken For The Geyser By The Contractor From Concerned Je E / M Before Quoting The Rate. 10 ( Ix ) S&F In Replacement Heating Element 2 Kw Triangle Type Suitable For 25 Ltr Capacity Vertical Type Water Heater Isi Mark. 11 ( X ) S&F Glass Wool Heat Insulation Superior Quality Suitable For Geyser Ofcapacity 25 / 35 / 50 Ltr 12 ( Xi ) S&F Outer Cover In Replacement Suitable For 25 Ltr Capacity Vertical Water Heater As Per Existing Model Heavy Duty Complete All As Specified And Directed. 13 ( Xii ) M&L For Spray Painting To Water Heater Of Capacity 25 Ltr Capacity By Spray Machine With Two Coats Of Synthetic Enamel Paint After Filling Cavities With Filler And Cleaning Dust Etc Complete All As Specified And Directed. 14 ( Xiii ) Supply Only Nuts, Bolts, Washers Suitable Of Existing Size And Model Suitable For Fixing Of Geyser Assembly With Geyser Tank Complete. 15 ( Xiv ) S&F Pvc Connection Mesh Type For Hot / Cold Water Supply 2 Long Heavy Duty Isi Mark As Per Sample Complete All As Specified And Directed. 16 M&L For Point Wiring Complete With Stranded Copper Conductor 4 Sqmm Size ( Nominal Area ) Pvc Insulated Unsheathed Frlshcable 1100 Volts Grade Confirming To Is: 694 Drawn In And Including Medium Grade Concealed Pvc Conduit Confirming Toisi Marked Not Less Than 25Mm Dia With Concealed Sunk-In Pressed Steel Terminal Boxes Of Required Size Not Less Than 1.2 Mm Thick Factory Made And Painted With Stove Enamelled Black Paint Top Cover 2.80 Mm Thick Plastic Laminated Sheet Of Required Colour Fixed With Brass Screwes And Cup Washers Including Single Core Stranded Copper Conductor 4 Sqmm Pvc Insulated Unsheathed Cable As Earth Wire To Common Earth And Connected To Earth Dolly Drawn In Same Concealed Conduit Complete All As Specified For One 6 Pin Socket Outlet Two In One 16 / 6 Amps On An Independent Board. ( For Geysers Point ) Note : 1 ) For Item No 2, 5 & 6 Rates Are Deemed To Be Included For Chases Of Conduit And Sunking For Boxes Cutting And Making Holes In Wall / Floor For Passing In Or Through Conduit. No Extra Payment Will Be Done On This Account 2 ) The Work Is Of Day To Day Repair Nature. Contractor Has To Engage A Supervisor To Collect The Complaint Slips From The Department On Day To Day Basis And Complete The Job In 2 Days. 17 -Ditto- But With Cable 2.5 Sqmm And Earth Continuity Conductor Of 2.5 Sqmm Stranded Copper Unsheathed Complete All As Specified And As Directed. 18 Supply And Fix Switch In Repairs Socket Combination 5 Amps / 16 Amps, 5 In 1, Flush Type All As Specified And Directed At Site. 19 Supply And Fixing In Repairs Calling Bell Ding Dong, Ac 230 Volts, Single Pole Complete All As Specified And Directed At Site. 20 S&F Domestic Surface Mounting 2 Gang Box For Fixing Of Socket Outlet And Switches Complete All As Specified And As Directed. 21 S&F Domestic Surface Mounting 3 Gang Box For Fixing Of Socket Outlet And Switches Complete All As Specified And As Directed. 22 S&F Domestic Surface Mounting 4 Gang Box ( Double Domestic ) For Fixing Of Socket Outlet And Switches Complete All As Specified And As Directed. 23 S&F Domestic Surface Mounting 5 Gang Box ( Double Domestic ) For Fixing Of Socket Outlet And Switches Complete All As Specified And As Directed. 24 S&F Domestic Surface Mounting 6 Gang Box ( Double Domestic ) For Fixing Of Socket Outlet And Switches Complete All As Specified And As Directed. 25 Supply And Fix In Replacement Mcb, Db , Spn 8 Way Suitable For Single Phase 240 Volts With 100 Amps Rated Bus Bar, Double Door Type Suitable For Mounting Incoming And Outgoing McbS Single / Double Pole Complete All As Specified And Directed At Site. 26 Supply And Fixing In Replacement Of Mcb Signle Pole 5-32 Amps 230 Volts B Series Complete All As Specified And As Directed. 27 Supply And Fixing In Replacement Of Mcb Single Pole And Neutral 40 / 63 Amps 230 Volts B Series Complete All As Specified And As Directed At Site. 28 S&F Mcb Sp 32 Amps 230 Volts B Series Complete All As Specified And Directed. 29 Supply & Fix In Replacement Of Spn Enclosure With Two Pin And Earth Plug And Socket Complete With One Sp Mcb 20 Amps Complete All As Specified And Directed By Engineer-In-Charge. Make:- Model No 607841 Of Make Legrand Or Equivalent In Siemens / Hagger / L&T. 30 M&L For Point Wiring Complete With Stranded Copper Conductor 1.5 Sqmm Size ( Nominal Area ) Pvc Insulated Unsheathed Frls Grade Cable 1100 Volts Grade Confirming To Is: 694 For Phase And Neutral Drawn In And Including Medium Duty Concealed Pvc Conduit Confirming Toisi Marked Not Less Than 20Mm Dia With Concealed Sunk-In Pressed Steel Terminal Boxes Of Required Size Not Less Than 1.2 Mm Thick Factory Made And Painted With Stove Enamelled Black Paint Top Cover 2.80 Mm Thick Plastic Laminated Sheet Of Required Colour Fixed With Brass Screwes And Cup Washers Including Single Core Stranded Copper Conductor 1.5 Sqmm Pvc Insulated Unsheathed Cable As Earth Wire To Common Earth And Connected To Earth Dolly Drawn In Same Concealed Conduit Complete All As Specified For The Following :-Note: -This Is Maint Work For Routine Daily Complaints And Keeping In View The Factcontractors Has To Deply Elect & Helper To Complete The Daily Works Alloted And The Work Shall Be Completed Within 48 Hrs Failing Which Rs 200 / - Per Complaint / Day Shall Be Recovered From The Contractor. 31 One Light Point Controlled By One Switch With Cables 1.5 Sqmm Size All As Specified And Directed. 32 One Fan Point / Exhaust Fan Controlled By One Switch With Cables 1.5 Sqmm Size All As Specified And Directed. 33 One Bell / Buzzer Point Controlled By One Push Button On The Same Board With Other Switches Or Independent With Cables 1.5 Sqmm Size All As Specified And Directed. 34 One 5 Pin Socket Oulet 5 / 6 Amps On Same Board Including Single Core Stranded Copper Conductor 1.5 Sqmm Pvc Insulated And Unsheathed Cable Drawn In Same Conduit As Earth Wire To The Common Earth Andconnecting To Earth Dolly All Asspecified. 35 One 3 Pin Socket Outlet, 5 Amps, Independent, With Cables 1.5 Sqmm Of Size All As Specified And Directed. 36 One Light Point Controlled By Two 2-Way Switches, With Cables 1.5 Sqmm Size All As Specified And Directed. 37 M&L For Point Wiring Complete With Stranded Copper Conductor 1.5 Sqmm Size ( Nominal Area ) Pvc Insulated Unsheathed Fr Grade Cable 1100 Volts Grade Confirming To Is: 694 Drawn In And Including Medium Duty Pvc Casing Caping Confirming Toisi Marked Not Less Than 20Mmincluding Single Core Stranded Copper Conductor 1.5 Sqmm Pvc Insulated Unsheathed Cable As Earth Wire To Common Earth And Connected To Earth Dolly Drawn In Same Concealed Conduit Complete All As Specified For The Following :- 38 One Light Point Controlled By One Switch With Cables 1.5 Sqmm Size All As Specified And Directed. 39 One Fan Point / Exhaust Fan Controlled By One Switch With Cables 1.5 Sqmm Size All As Specified And Directed. 40 One Bell / Buzzer Point Controlled By One Push Button On The Same Board With Other Switches Or Independent With Cables 1.5 Sqmm Size All As Specified And Directed. 41 One 5 Pin Socket Oulet 5 / 6 Amps On Same Board Including Single Core Stranded Copper Conductor 1.5 Sqmm Pvc Insulated And Unsheathed Cable Drawn In Same Conduit As Earth Wire To The Common Earth Andconnecting To Earth Dolly All Asspecified. 42 One 5 Pin Socket Oulet 5 / 6 Amps On Independent Board Including Single Core Straned Copper Conductor 1.5 Sqmm Pvc Insulated And Unsheathed Cable Drawn In Nsame Conduit As Earth Wire To The Common Earth Andconnecting To Earth Dolly All Asspecified. 43 Supply And Fix In Repairsswitch Piano, Flush Type Single Pole, One Way, 5 Amps, 240 Volts All As Specified And Directed At Site. 44 Supply And Fix In Repairs Switch Piano, Flush Type Single Pole, Two Way, 5 Amps, 240 Volts All As Specified And Directed At Site. 45 Supply And Fix In Repairs Bell Pushflush Type Single Pole, One Way, 5 Amps, 240 Volts All As Specified And Directed At Site. 46 Supply And Fixing In Repairs Socket Outlet 2 In 1, 3 Pin 5 Amps All As Specified And Directed At Site. 47 Supply And Fix In Repairs Ceiling Roses, 3 Phase, Pvc / Polycarbonate, Isolated Body All As Specified And Directed At Site. 48 Supply And Fix In Repairs Stepped Type Electronic Fan Regulator Flush Type On The Existing Phenolic Laminated Sheet Etc As Required All As Specified And Directed At Site. 49 Supply And Fix In Replacement Of 20 Watt ( 4Ft Long ) Decorative Box Type Fitting With Blue Coloured End Caps For Led Tube Etc Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cablefrom Ceiling Rose To Terminal Block And Testing Complete All As Specified And Directed At Site. 50 Supply And Fix In Replacement Of 12 Watt 2 Ft Decorative Box Type Fitting With Coloured End Caps For Led Tube Etc Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Twin Core Twisted Flexible Copper Conductor Cablefrom Ceiling Rose To Terminal Block And Testing Complete All As Specified And Directed At Site. 51 Supply And Fix Lamp Holder, Pvc / Polycarbonate Type With Back Plate Suitable For Batten Fitting Including With One Number 12 Watt Led Lamp Complete All As Specified And Directed. 52 S&F In Replacement Of 3Mm Thick Hylum Sheet Top Cover Of Size 11 X 9 On Switch Boards Wherever Damaged The Switch Boards Including The Cutting, Fixing And Screwing Etc All As Specified And Directed At Site. 53 S&F In Replacement Of 3Mm Thick Hylum Sheet Top Cover Of Size 8X 5 On Switch Boards Wherever Damaged The Switch Boards Including The Cutting, Fixing And Screwing Etc All As Specified And Directed At Site. 54 S&F In Replacement Of 3Mm Thick Hylum Sheet Top Cover Of Size 4X4 On Switch Boards Wherever Damaged The Switch Boards Including The Cutting, Fixing And Screwing Etc All As Specified And Directed At Site. 55 Supply & Fixcapacitor Of 2.5 Mfd Complete All As Specified And Directed. 56 -Ditto- But 3.15Mfd Complete All As Specified And Directed. 57 -Ditto- But 4.0 Mfd Complete All As Specified And Directed. 58 Supply & Fixcapacitor Of 0.85 / 1.00 Mfd Complete All As Specified And Directed. 59 Supply & Fix In Replacement Of Plug And Socket For Metal Clad Box Complete All As Specified And Directed By Engineer-In-Charge. Make:- Legrand Or Equivalent In Siemens / Hagger / L&T. 60 S&F Submain Wiring Withunsheathed Multi-Stranded Frls Grade Copper Conductor Cable 1100 Volts Grade Drawn Through In And Including Pvc Rigid Conduit Medium Grade Of Not Less Than 25Mm Dia With Conduit Accessories And Concealed In Wall / Surface Of Ceiling For Two Runs Of 6 Sqmm Single Core Hr Grade And One Run Of 6 Sqmm Pvc Insulated Copper Conductor For Earth Continuity Wire Between Main Db To Sub Main Db Complete All As Specified And As Directed.Note :- Two Run Of Single Core Cable With One Run Of Earth Continuity Conductor And Pvc Conduit And Accessories Will Be Measured As One Length Including Cutting Chasing In Wall Complete.Note 1: Rates Are Deemed To Be Included For Chases Of Conduit And Sunking For Boxes Cutting And Making Holes In Wall / Floor For Passing In Or Through Conduit. 61 S&F Submain Wiring Withunsheathed Multi-Stranded Frls Grade Copper Conductor Cable 1100 Volts Grade Drawn Through In And Including Pvc Rigid Conduit Medium Grade Of Not Less Than 25Mm Dia With Conduit Accessories And Concealed In Wall / Surface Of Ceiling For Two Runs Of 4 Sqmm Single Core Hr Grade And One Run Of 1.5 Sqmm Pvc Insulated Copper Conductor For Earth Continuity Wire Between Main Db To Sub Main Db Complete All As Specified And As Directed.Note :- Two Run Of Single Core Cable With One Run Of Earth Continuity Conductor And Pvc Conduit And Accessories Will Be Measured As One Length Including Cutting Chasing In Wall Complete.Note 1: Rates Are Deemed To Be Included For Chases Of Conduit And Sunking For Boxes Cutting And Making Holes In Wall / Floor For Passing In Or Through Conduit. 62 Supply And Fix Pvc Insulation Tape 18Mm Width And 25 M Length Complete All As Specified And Directed. 63 Suply And Fixing And Connecting Flexible Copper Twisted Twin Core Of Size 23 / .00076 Complete All As Specified And Directed By Engineer-In-Charge. 64 S & Fheavy Duty Pvccable , 1100 Volts Grade Insulated Aluminium Stranded Conductor, Twin Core Wire Of Size 6 Sqmm Complete All As Specified And As Directed. 65 S & F Heavy Duty Pvc Cable, 1100 Volts Gradeinsulated Aluminium Stranded Conductor, Twin Core Wire Of Size 10 Sqmm Complete All As Specified And As Directed. 66 Supply And Fixingrubber Shackle Complete With Bolt, Nut, Split Pin Complete All As Specified And As Directed. 67 S&F Cable Copper Flexible 3 Core Cicular Type 2.5 Sqmm Heavy Duty Complete All As Specified And Directed. 68 S&F Cable Copper Flexible 3 Core Cicular Type 4 Sqmm Heavy Duty Complete All As Specified And Directed. 69 Supply And Fix Surface Mounting Frame Less Panel, Square In Shape, Abs Housing And Pc Diffuser, Inbuilt Driver, 12 Watts.Item Code : Ld00118018, Make : Polycab Or Equivalent Model In Cg / Bajaj / Havells. 70 S&F Water Heater Vertical Type Ivory In Colour Cat Part No. G51 / 3025, Rated Power 2 Kwmake: Havells Or Equivalent In Cg / Philips / Wipro 71 Supply And Fixingball Bearing Suitable For Ceiling Fan, Wall Mounted Fan, Exhaust Fan, Pedestal Fan Of Same Size As That Of Existing Defective One Complete All As Specified And As Directed. 72 Supply And Fixing Bush Bearing Suitable For Ceiling Fan, Wall Mounted Fan, Exhaust Fan And Pedestal Fans Complete All As Specified And As Directed. 73 M&L For Cleaning And Preparing The Surfaces Of Ceiling Fan, Wall Mounted Fan, Exhaust Fan, Pedestal Fan, Removing The Grease, Carbon Dust Over The Fans And Painting With One Coat Of Synthetic Enamel Paint Of Approved Colour With Brush Painting And Writing Mes Number On The Fan All As Directed By Engineer-In-Charge. 74 M&L For Rewinding The Stator Complete With Super Enamelled Bare Copper Conductor With The Same Size And Number Of Turns As That Of The Old Oneinsulating, Varnishing And Pre Heating For The Following :- 75 Ceiling Fan 1200Mm / 1400Mm Sweep 76 Exhaust Fan 200Mm / 300 Mm Sweep 77 Exhaust Fan Above 450Mm Sweep