Supply, Installation, Testing And Commissioning Of: A ) “Cctv Surveillance System”, B ) “Fire Detection / Alarm System & Public Address System” For Newly Constructed State Cancer Institute Block At Skims Soura-2 Supply, Installation, Testing & Commissioning Of Indoor Ip Based Fix Type Dome Camera 2 Mp Or Higher, With 1 / 2.8 Inch Ccd High Resolution For All Guest Elevators With Power Supply, All Ancillary And Accessories Complete Etc As Required. 3 Supply, Installation, Testing And Commissioning Of Ip Based Indoor Bullet Camera 2 Mp Or Higher, With Vari-Focal Lens ( 3 - 10 ) Mm With Power Supply, All Ancillary Equipment & All Accessories Complete Etc As Required. 4 Supply, Installation, Testing And Commissioning Of 2Mp Or Higher, Ip Based Ptz Camera Ul / Fcc Listed Ip 18 X Optical And 12 X Digital Pan / Tilt / Zoom Cameras Including Integrated Housing ( Dome Type ) . Connectors, Lens. Camera Mounts, Power Supply And All Ancillary Equipment & All Accessories Complete Etc As Required. 5 Supply, Installation, Testing And Commissioning Of Keypad For Controlling Ptz Cameras Complete Etc As Required. 6 Supply, Installation, Testing And Commissioning Of 16 Channel Network Video Recorder To Be Supplied With Minimum 24 Tb Hdd And Shall Have Minimum Storage Of 30 Days Internal Hard Disk, Dvd / Usb Writer And As Per Technical Specifications Complete Etc As Required. 7 Supply, Installation Of 24 Port Layer - 2 Active Switch With ( Poe ) With Minimum 2 Fiber Port With Complete Accessories, As Per Specification Complete Etc As Required. 8 Supply, Installation Of 12 Port Layer - 2 Active Switch With ( Poe ) With Minimum 2 Fiber Port With Complete Accessories, As Per Specification Complete Etc As Required. 9 Supply, Installation, Testing And Commissioning Of Wall Mountable 55 Full Hd Led Monitor As Per Tender Specifications Complete As Required. 10 Supply & Laying Of 2 Core 1.5 Sq Mm Twisted Pair Cable For Ptz Camera Power In 25 Mm Dia. Ms Conduit Complete Etc As Required. 11 Supply & Laying Of Cat 6A Cable For Communication In Existing Dia. Ms Conduit Complete Etc As Required. 12 Supply And Fixing Of 16 Gauge Ms Conduit In Following Sizes, Including Cost Of Junction Boxes, Bends, Elbows, Sockets, Tees Etc. Laying In Slab Cutting Chassis And Making Good Or Surface Mounted Including All Fixing Hardware Complete Etc As Required. 13 25 Mm Dia. 14 32 Mm Dia. 15 Supply And Fixing Of Pvc Conduit Of Following Sizes Including Cost Of Junction Boxes, Bends, Elbows, Tees, Sockets Etc. Laying In Slab Cutting Chassis, Floor Cuttings And Making Grooves In Walls Etc. As Required. 16 25 Mm Dia. 17 32 Mm Dia. 18 Supply, Installation, Testing And Commissioning Of Network Rack’S Of 19” Wall / Floor Mounted With Complete Accessories Like Wire Manger, Hardware, Fan Tray With Fan’S, Power, Strip, Front Glass Door & Back Ms Doors Complete Etc As Required. 19 9 U Rack 20 12 U Rack 21 42 U Rack 22 Sub-Head ( B ) -1. Fire Detection / Alarm System 23 Supply, Installation, Testing & Commissioning Of Microprocessor Based Networkable Analogue Addressable Upto 200 Nodes 4 Loop With 4 Loop Card Fire Alarm Control Panel With 640 Character Lcd Touch Screen Display, The Panel Should Be Equipped With Sufficient Nos. Of Loops. Each Loop Shall Have A Capacity Of Min. 127 Analogue Addressable Devices In 1 Loop. Three Access Levels, Capable Of Taking En-54 Vds Approved Devices. Eprom Sufficient Nos. Of Programmable Relay Control For Controlling All Ahus, Pressurization Fans, Ventilation Fans At Fire Pump Room, Monitoring Of Fire Sprinkler & Fire Hydrant Pump, 240 V Ac Power Supply, Automatic Battery Charger, 24 V Sealed Lead Acid Batteries Sufficient For 24 Hours Normal Working & Then Be Capable Of Operating The System For 24Hours During An Emergency Conditions As Required. The Panel Shall Have Bacnet / Modbus. The Panel Shall Be Fully Expandable Up To 32 Loops, Power Supply And Charger To En-54 Part4, Dedicated Rs232 Serial Port For Direct Pc Or Modem Connection, Optional Remote Printer. 24 Supply, Installation, Testing & Commissioning Of Analogue Addressable Heat Sensor With Inbuilt Isolator Or Isolator Base / Module Having Removable High Performance Chamber With Twin Fire Leds Allow 360 Degree Viewing, Lock Mechanism ( Sensor To Base ) , Variable Sensitivity, Electronically Addressed, Approved By Vds. 25 Supplying, Installing, Testing & Commissioning Of Intelligent And Electronically Addressable Multi Sensor Detector With Microprocessor In Head And Including The Base With Led Etc. As Required. 26 Supply, Installation, Testing & Commissioning Of Analogue Addressable Loop Powered Wall Sounder Providing 8 Volume Levels & 51 Tones With A Maximum O / P Of Up To 102 Db ( A ) With Low Current Consumption, Can Be Fitted On Isolator Type Base Which Is Fully Compatible With Esp Analogue Addressable Protocol, User Selectable Modes, Electronically Addressed, Approved By Vds. 27 Supply, Installation, Testing & Commissioning Of Analogue Addressable Manual Call Point Esp Analogue Addressable Protocol Having Status Led For Alarming & Standby Mode, Electronically Addressed, Approved By Vds. 28 Supply, Installation, Testing & Commissioning Of Analogue Addressable Isolator Base Fully Monitored For Short / Open Circuit Compatible With Esp Analogue Addressable Protocol, Electronically Addressed, Approved By Vds. The Fault Isolator Shall Be Provided In Detection Lines As Per Ul Guidelines. 29 Supplying, Installing, Testing & Commissioning Of Analogue Addressable Response Indicator, Approved By Vds. 30 Supply & Laying Of 2 Core X 1.5 Sq Mm Annealed Copper Conductor Silicon Rubber Insulated Along With Tinned Annealed Copper Earth Conductor Covered With Electrostatic Screen Of Aluminum / Polyester Tape, Outer Sheathed With Low Smoke Zero Halogen ( Lszh ) Fire Survival Cable / Fire Resistant Conforming To Bs-6387 Cwz, Lpcb / Vds In Existing Conduit / Suface Certified Complete With Connectors Etc. As Required 31 Supply And Fixing Of 16 Gauge Ms Conduit In Following Sizes, Including Cost Of Junction Boxes, Bends, Elbows, Sockets, Tees Etc. Laying In Slab Cutting Chassis And Making Good Or Surface Mounted Including All Fixing Hardware Complete Etc As Required. 32 25 Mm Dia. 33 32 Mm Dia. 34 Sub-Head ( B ) -2 Public Address System 35 Amplifiers: Supplying, Installing, Testing & Commissioning Of 6 Zone Pa Controller With Required Amplifier + Digital Player, 2 Aux Input And Cd / Stereo Music Input, Built-In Mp3 Player With Remote Control And Lcd Display For Usb Sd / Mmc Card Reader, Line Input And Output On Each Zone For Connecting To A Mixer Or Booster Amplifier Respectively Etc. As Required. 36 Announcement Points: Supplying, Installing, Testing & Commissioning Of Pa Call Station Microphone, High Output Neodymium Cartridge, Excellent Intelligibility & Wide Frequency Response, Attractive Appearance Etc. As Required. 37 Speakers: 38 Supplying, Installing, Testing & Commissioning Of 6 W / 100V Ceiling Mounted Speaker, Aesthetically Designed Plastic Grille And Easy Mounting With Spring Loaded Clamps Etc. As Required. 39 Supplying, Installing, Testing & Commissioning Of 15 W / 100V Wall Mounted Column Speaker, Indoor & Outdoor Applications, Aluminum Extruded Cabinet With Die-Cast Aluminum Covers Etc. As Required. 40 Supplying And Drawing Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 41 2 X 1.5 Sq. Mm