| 1 | 1 | Material & Labour for General servicing of 1.5/2.0 TR capacity window type AC after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any including refixing the AC in same/ other location and connecting, commissioning complete all as directed by EIC. | | 80 | Job |
|---|
| 2 | 2 | All as per item No 1 here in above, but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 110 | Job |
|---|
| 3 | 3 | All as per item No 1 here in above, but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 85 | Job |
|---|
| 4 | 4 | All as per item No 1 here in above, but Water Cooler of capacity 40/40, 40/80 or 60/120 Litres | | 20 | Job |
|---|
| 5 | 5 | All as per item No 1 here in above, but Deep Freezer of capacity up to 420 Litres | | 1 | Job |
|---|
| 6 | 6 | All as per item No 1 here in above, but Refrigerator of capacity 165Ltrs to 310 Litres. | | 10 | Job |
|---|
| 7 | 7 | Material &Labour for General servicing of 1.0/1.5/2.0 TR capacity window type AC after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water at same location, replace the unserviceable parts if any including refixing the AC in same/ other location and connecting, commissioning complete all as directed. | | 100 | Job |
|---|
| 8 | 8 | All as per item No 7 here in above, but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 250 | Job |
|---|
| 9 | 9 | All as per item No 7 here in above, but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 275 | Job |
|---|
| 10 | 10 | All as per item No 7 here in above, but Air curtain of any capacity. | | 2 | Job |
|---|
| 11 | 11 | All as per item No 7 here in above but Water Cooler of capacity 40/40, 40/80 or 60/120 Ltrs.\nNote for item No. 1 to 11\nNote 1:- The quoted rate shall be deemed to include the cost of spare parts costing upto INR 250/-\nNote 2:- Replacing parts costing more than INR 250/- shall be measured and paid seperately under respective item. | | 50 | Job |
|---|
| 12 | 12 | Material & Labour for Leak testing of Window type Air Conditioner of capacity 1.0/1.5/2.0 TR including filling of nitrogen gas for pressure testing, finding leaks, Vacuumising the system, necessary brazing work, charging with refrigerant gas (R-22) of required quantity, testing for proper functioning all as specified and directed. | | 70 | Job |
|---|
| 13 | 13 | All as per item No 12 here in above but Split type Air Conditioner 1.5/2.0 Ton. | | 90 | Job |
|---|
| 14 | 14 | Supply & Fix in replacement, Hermatically sealed compressor unit suitable for Window / split type ACs of 1.5 Ton capacity in exchange of the existing unserviceable sealed compressor unit including connecting up complete all as specified & directed. | | 30 | Job |
|---|
| 15 | 15 | All as per item No 14 here in above but for 2.0 TR. | | 15 | Job |
|---|
| 16 | 16 | All as per item No 14 here in above but for split AC 2TR Inverter type. | | 5 | Job |
|---|
| 17 | 17 | All as per item No 14 here in above but for split AC 1.5TR Inverter type. | | 5 | Job |
|---|
| 18 | 18 | All as per item No 14 here in above but suitable for water cooler of capacity 40/40, 40/80 Litres. | | 10 | Job |
|---|
| 19 | 19 | All as per item No 14 here in above but suitable for Water Cooler of capacity 60/120 Litres. | | 2 | Job |
|---|
| 20 | 20 | All as per item No 14 here in above but suitable for Refrigerator of capacity 165 to 210 Litres. | | 2 | Job |
|---|
| 21 | 21 | All as per item No 14 here in above but suitable for Refrigerator of capacity 210 to 310 Litres. | | 2 | Job |
|---|
| 22 | 22 | All as per item No 14 here in above but suitable for Deep Freezer of capacity 420 Litres. | | 1 | Job |
|---|
| 23 | 23 | Supply & Fix Copper Condensing coil and aluminium fins suitable for 1.5TR capacity Window type Air conditioner including necessary brazing, gas charging, leak testing, Vacuumising etc including taking down old unserviceable condensing coil complete all as specified. | | 6 | Job |
|---|
| 24 | 24 | All as per item No 23 here in above but for 2.0 TR | | 6 | Job |
|---|
| 25 | 25 | All as per item No 23 here in above but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 10 | Job |
|---|
| 26 | 26 | All as per item No 23 here in above but cooling coil of Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 4 | Job |
|---|
| 27 | 27 | All as per item No 23 here in above but condensor coil suitable for Watercooler of capacity 40/40, 40/80 Litres | | 3 | Each |
|---|
| 28 | 28 | All as per item No 23 here in above but condensor coil suitable for Watercooler of capacity 60/120 Litres | | 2 | Each |
|---|
| 29 | 29 | Supply & Fix copper condensing coil and metallic fins suitable for 165 to 210 Litres capacity Refrigerator including necessary brazing, gas charging, leak testing, Vacuumising etc including taking down old unserviceable condensing coil complete all as specified. | | 2 | Each |
|---|
| 30 | 30 | All as per item No. 29 here in above but condensor coil suitable for refrigerator of capacity 210 to 310 Litres. | | 2 | Each |
|---|
| 31 | 31 | Supply and Fix in repair Evaporator coil made out of Copper tube suitable for Refrigerator of capacity 165 to 210 Litres all as per as specified and as directed | | 1 | Each |
|---|
| 32 | 32 | Supply and Fix in repair Evaporator coil made out of Copper tube suitable for Refrigerator of capacity 210 to 310 Litres all as specified and directed | | 1 | Each |
|---|
| 33 | 33 | Supply and Fix in repair Starting capacitor 120/150 MFD suitable for window/split AC all as specified and as directed | | 30 | Each |
|---|
| 34 | 34 | Supply and Fix in repair Running capacitor 45 MFD suitable for Window/Split type AC all as specified. | | 120 | Each |
|---|
| 35 | 35 | All as per item No 34 here in above but 36 MFD | | 120 | Each |
|---|
| 36 | 36 | All as per item No 34 here in above but 10 MFD | | 80 | Each |
|---|
| 37 | 37 | All as per item No 34 here in above but 8 MFD | | 70 | Each |
|---|
| 38 | 38 | Supply and Fix in repair Capacitor 6 MFD, 240V suitable for fan motor of Window / Split type AC all as specified and as directed. | | 70 | Each |
|---|
| 39 | 39 | All as per item No 38 here in above but 4MFD, 240 V. | | 50 | Each |
|---|
| 40 | 40 | All as per item No 38 here in above but 2/2.5MFD, 240 V. | | 100 | Each |
|---|
| 41 | 41 | All as per item No 38 here I above but 1.5MFD,240 V. | | 30 | Each |
|---|
| 42 | 42 | Supply and Fix in repair Fan motor 1/5 HP, 240V long shaft suitable for Window type AC of any capacity, make or model all as specified and as directed. | | 30 | Each |
|---|
| 43 | 43 | Supply and Fix in repair, blower motor for Indoor unit of any capacity suitable make or model complete all as specified and directed. | | 12 | Each |
|---|
| 44 | 44 | Supply and Fix in repair Fan motor 1/5 HP 240V suitable for outdoor unit of split type AC of any capacity make or model. | | 40 | Each |
|---|
| 45 | 45 | Supply and Fix in repair fan motor 1/35 HP 240V with leaf suitable for water cooler. | | 6 | Each |
|---|
| 46 | 46 | Supply and Fix in repair fan motor 240 V suitable for outdoor unit of inverter type Split AC of any capacity make or model. | | 8 | Each |
|---|
| 47 | 47 | Supply and Fix in repair Fan motor 240V suitable for indoor unit of inverter type Split AC of any capacity make or model complete all as specified and as directed. | | 8 | Each |
|---|
| 48 | 48 | Supply and Fix in repair Drain motor of Cassette type AC of any capacity complete all as specified and as directed. | | 3 | Each |
|---|
| 49 | 49 | Supply and Fix in repair Fan blade suitable for Window type AC of any capacity as per OEM, make or model complete all as specified and as directed. | | 50 | Each |
|---|
| 50 | 50 | Supply and Fix in repair Fan blade suitable for Outdoor unit of Split type AC of any capacity as per OEM, make or model complete all as specified and as directed. | | 40 | Each |
|---|
| 51 | 51 | Supply and Fixin repair Thermostat switch suitable for window type AC of any capacity, make or model complete all as specified and as directed. | | 50 | Each |
|---|
| 52 | 52 | Supply and Fix in repair Starting relay pin type suitable for Window / Split type AC of any capacity, make or model complete all as specified and as directed. | | 80 | Each |
|---|
| 53 | 53 | Supply and Fix in repair pre filter washable type suitable for Window type AC of any capacity, make or model complete all as specified and as directed. | | 40 | Each |
|---|
| 54 | 54 | Supply and Fix in repair pre filter washable type Fibre filter suitable for Split type AC of any capacity, make or model complete all as specified and as directed. | | 40 | Each |
|---|
| 55 | 55 | Supply and Fix in repair PVC float valve assembly 15mm bore suitable for water cooler complete all as specified and as directed. | | 30 | Each |
|---|
| 56 | 56 | Supply and Fix in repair15 mm bore lift cock tap suitable for water cooler complete all as specified and as directed. | | 30 | Each |
|---|
| 57 | 57 | Supply and Fix in repair 15 mm PVC connection 1 meter long suitable for water cooler complete all as specified and as directed. | | 20 | Each |
|---|
| 58 | 58 | Supply and Fix in repair 1 1/4\" flexible hose suitable for water cooler drain complete all as specified and as directed. | | 70 | RM |
|---|
| 59 | 59 | Removing old perished insulations and Supply and Fix nitrile rubber insulation of size 5/8\" for suction and liquid refrigerant line suitable for split type AC complete all as specified and directed. | | 200 | RM |
|---|
| 60 | 60 | Supply and Fix in repair Copper tube 3/8\" complete all as specified and directed. | | 240 | RM |
|---|
| 61 | 61 | Supply and Fix in repair Copper tube 5/8\" complete all as specified and directed. | | 240 | RM |
|---|
| 62 | 62 | Supply and Fix in repair Copper tube 3/4\" complete all as specified and as directed. | | 30 | RM |
|---|
| 63 | 63 | Supply and Fix in repair Copper tube 1/4\" complete all as specified and as directed. | | 180 | RM |
|---|
| 64 | 64 | Supply and Fix in repair Copper tube 1/2\" complete all as specified and as directed. | | 180 | RM |
|---|
| 65 | 65 | Supply and replace Prime Control Remote Board and temperature digital display sensor suitable for split type/Window AC of any capacity complete all as specified, as per site requirement. | | 60 | Each |
|---|
| 66 | 66 | Supply and replace Prime Control Remote Board and temperature digital display sensor suitable for 3 phase cassette type/Tower AC of any capacity, make or model complete all as specified, as per site requirement. | | 6 | Each |
|---|
| 67 | 67 | Supply and replace Prime Control Remote Board of inner unit and temperature sensor suitable for inverter type split type AC of 1.5/2 TR of any make or model of OEM complete all as specified, as per site requirement. | | 8 | Each |
|---|
| 68 | 68 | Supply and replace Prime Control Power Supply Board of outer unit suitable for inverter type split type AC of 1.5/2 TR, of any make or model of OEM all as specified, as per site requirement Notes For item 67 & 68: \nItem No 67 & 68 shall be procured and done through OEM authorised service centre only. | | 8 | Each |
|---|
| 69 | 69 | Supply and replace factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including necessary PCC work, making surface matching with existing etc. complete all as specified and directed. | | 40 | Each |
|---|
| 70 | 70 | Supply and fill Refrigerant Gas-R-22 . | | 382 | Kg |
|---|
| 71 | 71 | Supply and fill Refrigerant Gas-410a (Penta & Di Fluoroethane). | | 183 | Kg |
|---|
| 72 | 72 | Supply and fill Refrigerant Gas R- 32. | | 183 | Kg |
|---|
| 73 | 73 | Material & Labour in repair to voltage stabilizer 5 KVA by rewinding the main stabilizing unit and replacing PCB, sensing unit, power relay, connector piece and testing on completion complete all as specified and as directed | | 33 | Job |
|---|
| 74 | 74 | All as per item No 73 here in above but of 4KVA. | | 42 | Job |
|---|
| 75 | 75 | Supply & Fix in repair 3 Core multi stranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5 Sqmm. complete all as specified and as directed | | 270 | RM |
|---|
| 76 | 76 | All as per item No 75here in above but 4 core | | 90 | RM |
|---|
| 77 | 77 | Material & Labour for Sealed compressor unit suitable for 2.5/3 TR capacity 3 phase Tower /cassette type AC including first filling of refrigerant gas, compressor oil etc, testing and commissioning complete including taking down of old unserviceable one complete all as specified and directed. | | 2 | Job |
|---|
| 78 | 78 | Material & Labour for servicing of condenser coil of Tower split AC 2.5 / 5 TR capacity, Cleaning / Pressure washing of choked condenser fins, tubes etc. with water soluble material including leak testing complete all as specified and directed. | | 3 | Job |
|---|
| 79 | 79 | Material & Labour for servicing of condenser coil of cassette type AC 2.5 / 3/4 TR capacity, Cleaning / Pressure washing of choked drain lines, condenser fins, tubes etc. with water soluble material including leak testing complete all as specified and directed. | | 3 | Job |
|---|
| 80 | 80 | Supply & Fix in repair Fan motor suitable for outdoor unit of tower/cassette type AC of any capacity, make or model all as specified and directed. | | 6 | Job |
|---|
| 81 | 81 | Supply & Fix in repair Industrial type metallic 3 pin top 20 Amps 240v complete all as specified and directed. | | 50 | Each |
|---|
| 82 | 82 | Supply & Fix in repair 15 Amps 240 V Plug top Heavy Duty complete all as specified and directed. | | 50 | Each |
|---|
| 83 | 83 | Material & Labour for sub main wiring on wall /ceiling with two runs of 4 Sqmm single core PVC insulated un sheathed multi stranded copper conductor FR cable 1100V grade drawn through and including PVC conduit pipe of medium grade not less than 20mm dia and one run of 4 Sqmm cable single core 1100 V grade multi stranded copper conductor FR cable as earth continuity conductor and connecting with suitable size thimble including taking down of old one complete all as specified and directed\nNote: Two runs of sub main wire, One run of earth wire and PVC conduit with accessories shall be measured as One unit. | | 50 | RM |
|---|
| 84 | 84 | Supply & Fix in repair sheet metal enclosure single pole with a two pin and earth plug and socket complete with one single pole MCB 20 AMP, 240 v all as specified and as directed. | | 30 | Each |
|---|
| 85 | 85 | Supply & Fix in replacement of MCB SP 6 to 32 Amps \"C\" series 240v, complete all as specified and as directed | | 50 | Each |
|---|
| 86 | 86 | Material & Labour for spray painting single coat anti corrosive enamel paint to cover of window AC of any capacity complete all as specified and as directed | | 100 | Job |
|---|
| 87 | 87 | Material & Labour for spray painting single coat anti corrosive enamel paint to outer unit of split AC 1/1.5/2 TR capacity complete all as specified and as directed | | 200 | Job |
|---|
| 88 | 88 | Material & Labour for spray painting single coat anti corrosive enamel painting to water cooler of any capacity complete all as specified and as directed | | 20 | Job |
|---|
| 89 | 89 | Material & Labour for spray painting single coat anti corrosive enamel paint to cover of Refrigeration of any capacity complete all as specified and as directed | | 10 | Each |
|---|
| 90 | 90 | Wiring letters or figures for permanent marking of MES No with anti corrosive enamel paint not exceeding 03cm in height as numbers obtained from Engineer in charge in window AC/Split ACs inner and outer unit with thick approved colour paint complete all as specified and as directed | | 200 | Job |
|---|
| 91 | 91 | Supply & Fix of Stop valves of 15mm , chromium plate, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for CPVC pipe, unions and fixed complete all as specified and as directed. | | 15 | Each |
|---|
| 92 | 92 | Material & Labour for disconnecting the unserviceable stabilizer of any capacity 230 volts of any make from site and servicing complete and refixing back with necessary nuts/bolts fixed on walls and connecting up with A/C's drilling as per site requirement and all as directed by Engineer in charge. | | 20 | Each |
|---|
| 93 | 93 | Material & Labour for dismantling taking down after disconnection split A/C of capacity 1.5/ 2.0TR from existing location including indoor/ outdoor units along with its pipes, connecting cables, clamps/ stands, water drain pipes etc including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of A/C unit in all respect complete all as directed and specified by Engineer-in-charge | | 40 | Job |
|---|
| 94 | 94 | Amount of Credit Schedule shall be deducted to arrive the Contract Sum. | | | |
|---|