Tender For Supply And Installation Central Oxygen Pipeline For Govt. Hospitals In Yavatmal District- 1 Central Oxygen Nitrous And Suction Pipeline System Amc Per Gas Out Let 2 Oxygen Manifold Servicing And Repairing Complete With Its Nrv 3 Semi Automatic Panel Servicing And Repairing Complete 4 Iox-14 Control Panel Regulator 5 Dual Manifold Nrv System Semi Automatic Panel 6 Automatic Control Panel Servicing And Repairing Complete 7 Winding Of 5Hp Motor For Vacuum Pump 8 5Hp Motor Barring Bushing 9 V-Belt For Prime Mover 10 Crank Shaft 11 Connecting Rod 12 Block Cylinder 13 Gasket Block Cylinder 14 Vacuum Pump Seat Ring Metal & Rubber With Gasket Set & Valve Set 15 Vacuum Pump Low Pressure Switch With Necessary Fitting Rt121 16 Air Compressor Motor Winding 5Hp 17 Air Pump Seat Ring Metal & Rubber With Gasket Set & Valve Set 18 Air Pump Oil Per Litter Vacuum Pump Oil Per Litter 19 Air Pump Low Pressure Switch With Necessary Fitting 20 Air Gauge For Pipe Line 21 Dual Block For Dura Can With Teal Pipe Regulator System 22 Atmspheric Vaprisercapacity 50Mm3 / Hrservice Oxygenworking Pressure 25Bar 23 Starters 5 Hp Pump 24 Two Way Switch 25 Tail Pipe Copper With Null Nut & Nipple 26 Tail Pipe Flexible With Null Nut & Nipple 27 Bull Nipple 28 5 / 8 Nut Nipple 29 3 / 8 Nut Nipple 30 Single Key For Ss Valve 31 Skp For Ss Valve 32 Safety Key Plugs ( Schrader Type ) ( Oxygen, Vacuum , Nitrous Oxide , Air ) 33 Providing Supplying And Installing In Position Ward Vacuum Unit 600 Ml With Regulator 34 Providing Supplying And Installing In Position Ward Vacuum Unit 1000 Ml With Regulator 35 Providing Supplying And Installing In Position Ward Vacuum Unit 2000 Ml With Regulator 36 Theatre Suction Trolley With Ward Vacuum Unit 2000 Ml Double Bottleswith Regulator 37 Pvc Pipe For Vacuum Jar For One Meter 38 Yankey Suction With Hand Instrument 39 Vacuum Regulator 40 Suction Jar 1000 Ml Without Regulator 41 Suction Jar 600 Ml Without Regulator 42 Isolation Valve With All Brass Fittings 28 Mm 43 Isolation Valve With All Brass Fittings 22 Mm 44 Isolation Valve With All Brass Fittings 15 Mm 45 Isolation Valve With All Brass Fittings 12 Mm 46 Flow Meter With “S” Humid Fire Bottlesspanner ( F.A. Valve ) 47 “S” Humid Fire Bottles 48 Semi Automatic Control Panel 49 Automatic Control Panel 50 Control Panel Regulator ‘Central’ 51 Control Panel Nrv System 52 Low Pressure Alarm Pipe Line 53 Low Pressure Alarm Control Panel 54 Bed Head Panels For Icu / Hdu Bed Head Panels Horizontal / Verticalit Should Have The Following Features-Minimum Length 1.2 Meter. Efficient, Safe & Robust Design In Extruded 19Luminium Section. Smooth Curved Surfaces, With Acceptable Colour Choice Should Have An Integrated Rail System To Mount Accessories Segregation Of Services I.E. Low Voltage Supplies, High Voltage Supplies, And Medical Gases Should Be Maintained Throughout. Entire Pipe Line Should Run In Continuous Horizontalpanels With No Break For Each Unit & Length As Per Area Where It Has To Be Installed. Facility As Per Under-Oxygen -2, Vacuum-1, Medical Air -1, Infusion Pump Mount Pole With Adopter For Mounting At Least Twopumps.- Electrical Outlets- 6. Combined 15 / 5 55 Iox-14 Mox Regulator For Control Panel 56 Iox-14 Mox Regulator With Cylinder Fitting 57 Single Stage Double Gauge Moxregulator 58 Single Stage Single Gaugemox Regulator 59 High Pressure Tubing 6Mm Id ( White, Yellow , Blue, Gray ) 60 Spanner ‘B’ Type 61 Key For Pin Index Cylinder 62 Key Foro2, Co2 No2 Cylinder 63 Both Side 28 No Spanner For Cylinder Bull Nut 64 Screwspanner 10” 65 Screwspanner 12” 66 Pressure Gauge For Pipe Line ( 0 To 250 ) 67 Low Pressure Gauge For Pipe Line ( 0 To 16 ) 68 High Pressure Contact Gauge Electrical Oxygen 69 High Pressure Contact Gauge Electrical Nitrous Oxide 70 Nrv For Teal Pipe 71 Nrv Of Vacuum Tanks 72 Nrv Of Air Tanks 73 Vacuum Pump 5 Hpproviding, Supplying And Installing In Positionequivalent Make, Air Cooled, Reciprocating Vacuum Pump As Per Specification Mentioned Below, Rate Includes All Accessories, Fittings And Fixtures Require To Make The System Functional. Etc. Complete.Conversions: Volume:1Cfm=28.32Lpm, 1M3 / Hr=0.5885Cfm, Pressure:1Kg / Cm2g=14.223Psig, 1Bar=14.5 Psigtechnical Specifications Details 74 Air Compressorproviding, Supplying And Installation Of Reciprocating Air Compressor With Oil Free 5Hp Air Compressor Of Make As Per Following Configurations.Conversions: Volume:1Cfm=28.32Lpm, 1M3 / Hr=0.5885Cfm, Pressure:1Kg / Cm2g=14.223Psig1bar=14.5 Psigtechnical Specifications Details 75 Vertical Cylindrical Tank Up To 500 Ltr For Vacuum 76 Drier For Air Line 77 Horizontal Cylindrical Tank Up To 180 Ltr For Air 78 Providing Supplying And Installing Medical Gas Area Line Pressure Alarm With All Necessary Supporting To Make System Functional. 2 Gas 79 Providing Supplying And Installing Medical Gas Area Line Pressure Alarm With All Necessary Supporting To Make System Functional. 3 Gas 80 Providing Supplying And Installing Medical Gas Area Line Pressure Alarm With All Necessary Supporting To Make System Functional. 4 Gas 81 Providing Supplying And Installing In Position As Per Approved Layout And Instructions Given By In-Charge, With All The Necessary Require Fixtures, Fittings, Support System Require To Install To Make System Functional Etc. Complete. 10 Mm Copper Pipe Od 0.7 Lloyd’S With All Imported Copper Fittings 82 Providing Supplying And Installing In Position As Per Approved Layout And Instructions Given By In-Charge, With All The Necessary Require Fixtures, Fittings, Support System Require To Install To Make System Functional Etc. Complete. 15 Mm Copper Pipe Od 0.9 Lloyd’S With All Imported Copper Fittings 83 Providing Supplying And Installing In Position As Per Approved Layout And Instructions Given By In-Charge, With All The Necessary Require Fixtures, Fittings, Support System Require To Install To Make System Functional Etc. Complete. For 22 Mm Copper Pipe Od 0.9 Lloyd’S With All Copper Fittings 84 Providing Supplying And Installing In Position As Per Approved Layout And Instructions Given By In-Charge, With All The Necessary Require Fixtures, Fittings, Support System Require To Install To Make System Functional Etc. Complete. Do As Above For 28 Mm Copper Pipe Od 0.9 Lloyd’S With All Copper Fittings 85 Providing, Supplying And Installation Of Two By Two Oxygen Manifold With Nrv Including 86 M.S. Frame Work For Manifoldhaving Capacity Per Cylinder Two By Two Required 87 Providing, Supplying And Installation Of Four By Four Oxygen Manifold With Nrv Including 88 M.S. Frame Work For Manifoldhaving Capacity Per Cylinder Four By Four Required 89 Providing, Supplying And Installation Of Ten By Ten Oxygen Manifold With Nrv Including All Necessary Accessories And Fittings Require To Make System Functional. 90 M.S. Frame Work For Manifoldhaving Capacity Per Cylinder Ten By Ten Required 91 Oxygen Hood 92 Oxygen Mask Single Use & Latex Free 93 Oxygen Nasal Cannula Single Use& Latex Free 94 Self Sealing Valve For O2, / Va / N2o / Air 95 100 Shade28mm 96 Area Two Gas Join-Box 97 Area Three Gas Join-Box 98 Area Four Gas Join-Box 99 Medicaloxygen Cylinderhigh Pressure Seamless Steel Gas Cylinderscapacity 46.7 Water Liters Mo2 Cylinder With Valve Without Capactualtesting Pressure -250Kg / Cm Squaretear Weight -52 Kg Approxworking Pressure -150 Barnormal Length -1365Mm ( Approx ) Out Side Diameter -232+-1%Bottom –Concaveneck Threadingis3224:2002 14Tpi Type 4 Size 2 100 Medicaloxygen Cylinderhigh Pressure Seamless Steel Gas Cylinderscapacity 10 Water Litters Mo2 Cylinder With Valve Without Capactualtesting Pressure -250Kg / Cm Squaretear Weight -10 Kg Approxworking Pressure -150 Barnormal Length -1365Mm ( Approx ) Out Side Diameter -232+-1%Bottom –Concaveneck Threadingis3224:2002 14Tpi 101 Medicaloxygen Ip 1320 Ltr Cylinder Refillingtransport Charges Extra Up To Hospital 102 Medicaloxygen Ip 7000 Ltr Cylinder Refillingtransport Charges Extra Up To Hospital 103 Dura Cylinder Refilling Liquid Oxygen Iptransport Charges Extra Up To Hospital