Procurement Of Power And Control Cabels.-Karnataka

Karnataka Power Corporation Limited has published Procurement Of Power And Control Cabels.. Submission Date for this Tender is 20-05-2021. Coats and Jackets Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

27834702
Procurement Of Power And Control Cabels.
Open Tender
Indian
Karnataka
20-05-2021

Tender Details

Procurement Of Power And Control Cabels. 1. 3Cx70sqmm, Al, Zhfrls Cable 3C X 70 Sqmm, 1.1Kv, Stranded Compacted Sector Shaped Alluminum Conductor, Extruded Xlpe Insulated, Cores Laid Up, Extruded Frls-Zh Type St-8 Inner Sheathed, Galvanised Steel Round Wire Armour, Extruded Frls-Zh Type St-8 Outer Sheathed Cable, Generally Confirming To Is:7098 (Part-1) 1988 & Iec:60502-1, Packing Length Tolerance Shall Be +5Mtrs, Tests: The Cables Shall Be Offered For Tests On The Manufactured Length For The Customer Witness. The Tests Shall Include Routine, Flammability & Other Tests As Specified In Iec 60502-1, Printing: Manufacturers Name, Customers Name As Btps Kpcl, Date Of Manufacturing, No. Of Cores, Conductor Size, Voltage Grade, Insulation Type & Sequential Length At Every 1Mtr, Drum: Wooden Drum, Approval Of Guaranteed Technical Particulars Is Required For Manufacturing Clearance Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt, 2. 3.5Cx120sqmm, Al, Zhfrls Cable 3.5C X 120Sqmm, 1.1Kv, Stranded Compacted Sector Shaped Alluminum Conductor, Extruded Xlpe Insulated, Cores Laid Up, Extruded Frls-Zh Type St-8 Inner Sheathed, Galvanised Steel Round Wire Armour, Extruded Frls-Zh Type St-8 Outer Sheathed Cable, Generally Confirming To Is:7098 (Part- 1) 1988 & Iec:60502-1, Packing Length Tolerance Shall Be +5Mtrs, Tests: The Cables Shall Be Offered For Tests On The Manufactured Length For The Customer Witness. The Tests Shall Include Routine, Flammability & Other Tests As Specified In Iec 60502-1, Printing: Manufacturers Name, Customers Name As Btps Kpcl, Date Of Manufacturing, No. Of Cores, Conductor Size, Voltage Grade, Insulation Type & Sequential Length At Every 1Mtr, Drum: Wooden Drum , Approval Of Guaranteed Technical Particulars Is Required For Manufacturing Clearance, Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt, 3. 3Cx400sq.Mm Al. Cable 3Cx400sq.Mm Al. Cable Frls Insulated Extruded Pvc Inner Sheathed Flat Strip Gi Armoured Overall Pvc Sheathed Aluminium Conductor Power Cable Confirming To Is-7098 (Part-1) For Working Voltage Up To 1.1Kv Grade( Frequential Marking On Outer Sheath Regd.) Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt., 4. 3Cx300sqmm Pvc Frls Lt Cable 3C X 300 Sq. Mm, 1100 Grade, Lt Cable, Type Of Cable : Aywy Voltage Grade : 1100V Conductor Material : H4 Grade Aluminum As Per Class 2 Of Is: 8130/84, Latest. Max. D.C Resistance Of Conductor : 0.1 At 20Deg (Ohm/Km) Conductor Shape : Stranded Compact Sector. Insulation Material : Pvc Type A As Per Is: 5831/84 (Nominal Thickness 2.4Mm) Core Identification : By Colored Strips (Red, Yellow And Blue) Inner Sheath Material : Extruded Pvc Type St1 To Is 5831/84 (Min. Thickness 0.6Mm) Armouring Material : Galvanized Steel Type Of Armouring : Round Wire (Nominal Size 2.5Mm) Outer Sheath Material : Pvc Type St1 As Per Is: 5831/84 With Frls Properties (Min. Thickness 2.36 Mm) Frls Properties : Oxygen Index (Astmd 2863 77) Min. 29Percent Temp. Index (Astmd 2863 77) Min. 250Deg Smoke Density Rating (Astmd 2843) Max. 60Deg Hcl Gas Generation (Iec754 I) Max. 20Percent By Weight Electrical Parameters Max. A.C Resistance Of Conductor By 70Deg (Ohm/Km) : 0.122 Calculated Cable Reactance (Ohm/Km) : 0.0732 Impedance Of Cable (Ohm/Km) : 0.142 Approx. Cable Capacitance (Mfd/Km) : 1.35 Max. Conductor Temp. Under Normal Operating Condition : 70Deg Max. Conductor Temp. At The Termination Of Short Circuit : 160Deg Short Circuit Rating Of Conductor For Duration Of 1 Sec: 22.81 Ka Continuous Current Carrying Capacity : In Ground At 30Deg 305A, In Air At 40Deg 315A Standards To Which The Cable Confirms: Is 8130/84, Is 1554 Part1/88, Is 5831/84, Is 3975/88 Etc With Latest Up To Date Amendments Approx. Overall Diameter (Mm) : 58.5 Minimum Bending Radius : 12 Times Overall Diameter Printing : Year, Manufacturer Name, Kv Grade, Xlpe, Frls, Cable Size,Cable Type With Sequential Marking At Every One Meter Interval. Embossing : Year, Size In Sq. Mm, Grade Standard Drum Length : 500 Mtr+/- 5% Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt, 5. 3 1/2 C X 240 Sqmm U.G. Cable U.G Lt 1.1 Kv Class Multi Strand Xlpe Insulated Armoured Sheathed Aluminium Cable As Per Is-7098, Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt, 6. 3 1/2 C X 300 Sqmm U.G Cable U.G Lt 1.1 Kv Class Multi Strand Xlpe Insulated Armoured Sheathed Aluminium Cable As Per Is-7098, Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt, 7. 108710419R 3 1/2C X 35 Sqmm Ug Cable Type Of Cable : A2xwy Voltage Grade : 1100V Conductor Material : H4 Grade Aluminum As Per Class 2 Of Is: 8130/84, Latest. Max. D.C Resistance Of Conductor : 0.868(Main) 1.91(Neutral) At 20Deg (Ohm/Km) Conductor Shape : Stranded Compacted Sector. Insulation Material : Pvc Type A As Per Is:5831/84 (Nominal Thickness Main: 1.2Mm, Neutra: 1.0Mm) Core Identification : By Colored Strips (Red,Yellow And Blue) Inner Sheath Material : Extruded Pvc Type St1 To Is 5831/84 (Min. Thickness 0.3Mm) Armouring Material : Galvanized Steel Type Of Armouring : Round Wire (Nominal Size 1.6 Mm) Outer Sheath Material : Pvc Type St1 As Per Is: 5831/84 With Frls Properties (Min. Thickness 1.4 Mm) Frls Properties : Oxygen Index (Astmd 2863 77) Min. 29Percentage Temp Index(Astmd 2863 77) Min 250 Deg Smoke Density Rating(Astmd 2843) Max. 60Deg Hcl Gas Generation (Iec754 I) Max. 20Percentage By Weight Electrical Parameters Max. A.C Resistance Of Conductor By 90°C (Ohm /Km) : 1.04 Calculated Cable Reactance (Ohm /Km) : 0.082 Impedance Of Cable (Ohm /Km) : 1.04 Approx. Cable Capacitance (Mfd/Km) : 0.96 Max. Conductor Temp. Under Normal Operating Condition : 70°C Max. Conductor Temp. At The Termination Of Short Circuit: 160°C Short Circuit Rating Of Conductor For Duration Of 1 Sec : 2.66 Ka Continuous Current Carrying Capacity : In Ground At 30°C - 92 A, In Air At 40°C - 86A Standards To Which The Cable Confirms: Is 8130/84, Is 1554 Part1/88, Is 5831/84, Is 3975/88 Etc With Latest Up To Date Amendments Approx. Overall Diameter (Mm) : 27.5 Minimum Bending Radius : 12 Times Overall Diameter Printing: Year, Manufacturer Name, Kv Grade, Xlpe, Frls, Cable Size,Cable Type With Sequential Marking At Every One Meter Interval. Embossing: Year, Size In Sq. Mm, Grade Standard Drum Length: 500 Mtr+/- 5% Make:Kei/Polycab/Havells/Unistar/Finecab/Torrent/Ralicab/Universal/Rpg/Uniflex/Delton/Finolex/Lappindia/Cci/Sbee/Shyam/Imt,

Key Value

Document Fees
INR 550 /-
EMD
INR 9000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail