}

Restoration Of 200 T Eot ( Electric Overhead Travelling ) Cranes- Supply Of Spares , Its Installation , Testing And Commissioning Of 02 Nos . 200T Eot Cranes Of Power House Of Parbati He Project ( Stage-Ii ) ( Proc-1854 ), Power House of PHEP-II,Sainj,Kullu(H.P.)-Himachal Pradesh

National Hydroelectric Power Corporation Limited has published Restoration Of 200 T Eot ( Electric Overhead Travelling ) Cranes- Supply Of Spares , Its Installation , Testing And Commissioning Of 02 Nos . 200T Eot Cranes Of Power House Of Parbati He Project ( Stage-Ii ) ( Proc-1854 ). Submission Date for this Tender is 02-06-2021. Footwears Tenders in Power House of PHEP-II,Sainj,Kullu(H.P.) Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27741509
Corrigendum : Restoration Of 200 T Eot ( Electric Overhead Travelling ) Cranes- Supply Of Spares , Its Installation , Testing And Commissioning Of 02 Nos . 200T Eot Cranes Of Power House Of Parbati He Project ( Stage-Ii ) ( Proc-1854 )
Open Tender
Indian
Himachal Pradesh
Power House Of Phep-Ii,Sainj,Kullu(H.P.)
02-06-2021

Tender Details

Restoration Of 200 T Eot ( Electric Overhead Travelling ) Cranes- Supply Of Spares , Its Installation , Testing And Commissioning Of 02 Nos . 200T Eot Cranes Of Power House Of Parbati He Project ( Stage-Ii ) ( Proc-1854 ) , Lt Gear Box Oil Seal ( 04 Nos Gear Box ) As Per Sl . No . -1 Of Ts , Lt Brake Drum Eht As Per Sl . No . -2 Of Ts , Lt Brake Drum Dcem As Per Sl . No . -3 Of Ts , Lt Brake Liner With Shoe As Per Sl . No . -4 Of Ts , Lt Dcem Brake As Per Sl . No . -5 Of Ts , Lt Eht Brake As Per Sl . No . -6 Of Ts , Lt Full Gear Coupling As Per Sl . No . -7 Of Ts , Lt Limit Switch As Per Sl . No . -8 Of Ts , Ct Gear Box Oil Seal ( 02 Nos Gear Box ) As Per Sl . No . -9 Of Ts , Ct Brake Liner With Shoe As Per Sl . No . -10 Of Ts , Ct Dcem Brake Liner As Per Sl . No . -11 Of Ts , Ct Limit Switch As Per Sl . No . -12 Of Ts , Ct Eht Brake As Per Sl . No . -13 Of Ts , Ct Dcem Brake As Per Sl . No . -14 Of Ts , Ct Brake Drum For Eht As Per Sl . No . -15 Of Ts , Ct Brake Drum For Dcem As Per Sl . No . -16 Of Ts , Ah Gear Box Oil Seal As Per Sl . No . -17 Of Ts , Ah Brake Liner With Shoe As Per Sl . No . -18 Of Ts , Ah Dcem Liner As Per Sl . No . -19 Of Ts , Ah Motor Bearing As Per Sl . No . -20 Of Ts , Ah Counter Weight Limit Switch As Per Sl . No . -21 Of Ts , Ah Limit Switch As Per Sl . No . -22 Of Ts , Ah Eht Brake As Per Sl . No . -23 Of Ts , Ah Decm Brake ( In Built Rectifier ) As Per Sl . No . -24 Of Ts , Ah Brake Drum Eht As Per Sl . No . -25 Of Ts , Ah Decm Brake Drum As Per Sl . No . -26 Of Ts , Mh Gear Box Oil Seal As Per Sl . No . -27 Of Ts , Mh Brake Dcem ( In Built Rectifier ) As Per Sl . No . -28 Of Ts , Mh Brake Eht As Per Sl . No . -29 Of Ts , Mh Eht Liner With Shoe As Per Sl . No . -30 Of Ts , Mh Dcem Liner With Shoe As Per Sl . No . -31 Of Ts , Mh Brake Drum Eht As Per Sl . No . -32 Of Ts , Mh Limit Switch As Per Sl . No . -33 Of Ts , Mh Counter Weight Limit Switch As Per Sl . No . -34 Of Ts , Lt Wheel Bearing ( Drive ) As Per Sl . No . -35 Of Ts , Lt Wheel Bearing ( Idle ) As Per Sl . No . -36 Of Ts , Ct Wheel Bearing ( Drive Side ) As Per Sl . No . -37 Of Ts , Ct Wheel Bearing ( Idle Side ) As Per Sl . No . -38 Of Ts , Ah Dbr As Per Sl . No . -39 Of Ts , Protective Panel Main Contactor As Per Sl . No . -40 Of Ts , Mh/Ah Main Contactor ( For Mh/Ah Ac Drive: 75Kw , Rating: 140A , Type: Pf-700 ( 20Bc170a2aynanco ) As Per Sl . No . -41 Of Ts , Ct Main Contactor ( For Ct Ac Drive: 7 . 5Kw , Rating: 17A , Type: Pf-40 ( 22Bd017n104 ) As Per Sl . No . -42 Of Ts , Lt Main Contactor ( For Lt Ac Drive: 18 . 5Kw , Rating: 37A , Type: Pf-700 ( 20Bc037a2aynana0 ) As Per Sl . No . -43 Of Ts , Lt & Ct Limit Switches As Per Sl . No . -44 Of Ts , Mh/Ah/Ct/Lt Master Controller As Per Sl . No . -45 Of Ts , Contactor As Per Sl . No . -46 Of Ts , Contactor As Per Sl . No . -47 Of Ts , Contactor As Per Sl . No . -48 Of Ts , H . R . C Fuse As Per Sl . No . -49 Of Ts , H . R . C Fuse As Per Sl . No . -50 Of Ts , H . R . C Fuse As Per Sl . No . -51 Of Ts , Contactor As Per Sl . No . -52 Of Ts , Contactor As Per Sl . No . -53 Of Ts , Contactor As Per Sl . No . -54 Of Ts , Ct Ac Drive As Per Sl . No . -55 Of Ts , Grease Nipple As Per Sl . No . -56 Of Ts , Panel Lock All Panel As Per Sl . No . -57 Of Ts , Lt Main Mccb As Per Sl . No . -58 Of Ts , Ct Dbr As Per Sl . No . -59 Of Ts , Lt Dbr As Per Sl . No . -60 Of Ts , Mcb /Ct As Per Sl . No . -61 Of Ts , Mh Power Switch Fuse Unit As Per Sl . No . -62 Of Ts , Pp Main Isolating Switch As Per Sl . No . -63 Of Ts , Mh Dbr As Per Sl . No . -64 Of Ts , Ct Ac Drive As Per Sl . No . -65 Of Ts , Ct Mcb As Per Sl . No . -66 Of Ts , Lt Motor ( S . Q Cage ) Bearing For De & Nde As Per Sl . No . -67 Of Ts , Monorail Ct Motor ( S . Q Cage ) Bearing For De & Nde As Per Sl . No . -68 Of Ts , Monorail Hoist Motor ( S . Q Cage ) Bearing For De & Nde As Per Sl . No . -69 Of Ts , Installation , Testing And Commissioning Charges For Eot Cranes

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 19-05-2021 Corrigendum No. 1 Date 02-06-2021

Key Value

Document Fees
INR 1180 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail