}

Provision Of Certain Special Items For Maritime Acquatic Water Training Facility And Other Allied Structures At Icgs Okha, OKHA UNDER GE I CG PORBANDAR-Goa

Statutory Bodies & Commissions/Committees has published Provision Of Certain Special Items For Maritime Acquatic Water Training Facility And Other Allied Structures At Icgs Okha. Submission Date for this Tender is 10-05-2021. Uniform Tenders in OKHA UNDER GE I CG PORBANDAR Goa. Bidders can get complete Tender details and download the document.




Tender Notice

27655354
Corrigendum : Provision Of Certain Special Items For Maritime Acquatic Water Training Facility And Other Allied Structures At Icgs Okha
Open Tender
Indian
Goa
Okha Under Ge I Cg Porbandar
10-05-2021

Tender Details

Provision Of Certain Special Items For Maritime Acquatic Water Training Facility And Other Allied Structures At Icgs Okha-14 Internal Electric Supply Ns & F 20 W Surface / Wall Mounted Led Batten Having High Efficiency Long Life Led Chips With Luminous Efficacy Of > 100 Lumen / W, Independent Isolated Smps Based Constant Current Electronic Led Driver With Thd < 20%, Surge Voltage Protection And Other Safety Tests As Per Is: 15885 ( Part-2 / Sec-13 ) : 2012, Polycarbonate Diffuser, Housed In Powder Coated White Extruded Aluminium Channel Housing And White Coloured Abs End Caps Having Input Voltage 220- 240 V, Input Frequency 50- 60 Hz, Pf > 0.95, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fixture Complete All As Specified And Directed. Nmake: Bajaj Cat-Part No. 112785 Bclab 20W Or Equivalent Model Of Havells, Philips Or Wipro 15 S & F 10 W Surface / Wall Mounted Led Batten Having High Efficiency Long Life Led Chips With Luminous Efficacy Of > 100 Lumen / W, Independent Isolated Smps Based Constant Current Electronic Led Driver With Thd < 20%, Surge Voltage Protection And Other Safety Tests As Per Is: 15885 ( Part-2 / Sec-13 ) : 2012, Polycarbonate Diffuser, Housed In Powder Coated White Extruded Aluminium Channel Housing And White Coloured Abs End Caps Having Input Voltage 220- 240 V, Input Frequency 50- 60 Hz, Pf > 0.95, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fixture Complete All As Specified And Directed. Nmake: Bajaj Cat-Part No. 112407 Bclsb 10 Wh Or Equivalent Model Of Havells, Philips Or Wipro 16 S & F 20 W Led Street Light Having High Efficiency Long Life Led Module With Smd Led Package Mounted On Mcpcb With High Led Efficacy Of = 100 Lumen / W, Integral Smps Based Constant Current Electronic Led Driver With Thd < 20%, Surge Voltage Protection And Other Safety Tests As Per Is: 15885 ( Part-2 / Sec-13 ) : 2012, Ip 66 Protection, High Effiency Polycarbonate Cover With Integrated Lens Housed In Pressure Die-Cast Aluminium Alloy Heat Sink For Effective Thermal Management, Sturdiness, Excellent Corrosion Resistance, Separate Optical And Control Gear Compartment & Top Opening For Easy Maintenance, Suitable For Side Entry, Pole / Wall Mounted With Bracket 1.5 M Long With Including Necessary Electrical Connection To The Fixture With 3 Core Flexible Cu Conductor Cable Of Appropriate Size And Light Grade Gi Pipe, Including Gi Clamps, Nuts, Bolts & Washers With Two Coats Of Synthetic Enemal Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed. Nmake: Bajaj Cat-Part No. Bajaj 169829 Bclst 20W Led I Or Equivalent Model Of Havells, Philips Or Wipro 17 S & F Bldc Five Star Rated Energy Efficient High-Speed Ceiling Fan Having 1200 Mm Blade Sweep, Air-Flow Not Less Than 210 Cmm, Operating Voltage 220-240 V And Frequency 50 Hz, Including A Downrod Of Suitable Size And Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fan Complete All As Specified And Directed. Nmake: Crompton Cat-Part No. Entrust50 Or Havells Cat- Part No. Es-50 Or Equivalent Model Of Usha Or Bajaj 18 S & F Engery Efficient Non-Metalic Fresh Air Fan Having Blade Sweep 250 Mm, Air Delivery Not Less Than 860 Cmh, Operating Voltage 220-240 V And Frequency 50 Hz, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fresh-Air Fan Complete All As Specified And Directed. Nmake: Crompton Cat-Part No. Ventilus 10 Or Equivalent Model Of Usha, Havells Or Bajaj 19 S & F Energy Efficient Metalic Exhaust Fan Having Blade Sweep 300 Mm, Air Delivery Not Less Than 900 Cmh, Operating Voltage 220-240 V And Frequency 50 Hz, Including Electrical Connection With 3 Core Flexible Cu Conductor Cable Of Appropriate Size From Ceiling Rose To The Fresh-Air Fan Complete All As Specified And Directed. Nmake: Crompton Cat-Part No. Trans Air 12 Or Equivalent Model Of Usha, Havells Or Bajaj 20 S & F Vertical Triple Pole & Neutral, Double Door, Metallic Modular Distribution Board Conforming To Iec 61439-3, Suitable For Flush / Surface Mounting With Provision For Mccb Up To 250 A As Incomer And Sp / Tp Mcbs As Outgoing, Reversible Metal Door, Fully Insulated 400A Copper Busbar For Each Phase, Two Fully Insulated & Shrouded Neutral Bars, Two Earthbars, Cable Ties For Cable Management, Prefitted Masking Sheet, Etc. Having Ik 09 & Ip 43 Protection Complete All As Specified And Directed. Nnotes: N [ I ] Mcbs / Rcbos / Mccbs Shall Be Measured And Paid In Revelant Items. N Vertical Triple Pole And Neutral Db, 4 Way Nmake: Legrand Ekinox³ Cat-Part No. 5077 25 Or Equivalent Model Of Schneider, Siemens Or Abb N N N N 21 S & F Mcb For Ac Applications Conforming To Is / Iec 60898-1-2002, Having Breaking Capacity Icn = 10 Ka, Sliding Bottom Clamp, Colour Coded On / Off Indication On Dolly, Biconnect Ip 20 Protected Lower Terminals And Sliding Shutters, Etc. Complete All As Specified And Directed By Engineer-In-Charge. Nmake: Schneider, Legrand, Havells N ( A ) 6 A, Sp Mcb, C- Curve N 22 ( B ) 16 A, Sp Mcb, C- Curve 23 ( C ) 20 A, Sp Mcb, C- Curve 24 ( D ) 20 A, Dp Rcbo, C- Curve 25 ( E ) 32 A, Tp Mcb, C- Curve 26 ( F ) 32 A, Tpn Rcbo, C- Curve 27 ( G ) 63 A, Tp Mcb, C- Curve 28 S & F Moulded Case Circuit Breaker ( Mccb ) , Four Pole, In Single Frame Size Up To 250 A With Thermal Magnetic Trip Unit ( Tmd ) , Compression Lug Connectors, Protection Against Overloads ( Ir Adjustable From 0.7- 1 X In ) , Protection Against Short Circuits ( Isd Adjustable From 1.5- 10 X Ir ) , Inbuilt Encapsulated Double Break Roto Active Type Instanteneous Protection, Earth Fault Leakage Protection, Etc. Having Ics = 100% Icu As Per Iec 60947-2 Complete All As Specified And Directed By Engineer-In-Charge. Nmake:Legrand, Schneider, Siemens, Abb N ( A ) 200 A, 415 V, 16 Ka, 50 Hz Fp Mccb 29 ( B ) 100 A, 415 V, 16 Ka, 50 Hz Tp Mccb 30 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode Of 60 Cm X 60 Cm X 6 Mm Size, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 M Below Normal Ground Level, Connected To Galvanised Iron Strip Of Size 32X6 Mm As Earth Lead, By Means Of Bolts, Buts, Check Nuts And Washers Of Galvanised Iron Or Steel, Galvanized Iron Pipe Of 40 Mm Diameter, Connected To Earthing Test Point, All As Shown In Electrical Plate No. 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion And Including Excavation, Earthwork, Pcc Earth Pit Of Dimensions 550 Mm X 550 Mm ( Outer ) And 300 Mm X 300 Mm ( Inner ) And 250 Mm Deep, With A 10 Mm Thick Ci Cover, Hinged To Ci Frame On Ground Level, Gi Watering Pipe, Funnel, Etc. As All Specified And Directed. 31 ( Road / Path / Culvert ) Ns & F 9 To 10Mm Thick Coloured Designer Heavy Duty Vitrified Non Skid Pavement Tiles Of Approved Pattern All As Specified And Directed. 32 Filtration System Nsupply, Installation, Testing & Commissioning Of Circulating Pumps Cast Iron Pumps 3000 R.P.M. Mechanical Seal In Stainless Steel. I.P.-54 Motor Protection. Stainless Steel Shaft. With Stainless Steel Strainer Basket. Conn. ( 2 Working 1 Standby ) Flow Rate : 80M3 / H @ 30M.Head. Nmake: Kirlosker, Jhonson, Wilo, Astral Pool. 33 M&L For Pn 1.6 Rated 200Mm Nb Polypropelene Vortex Inhabitor Suction Lift Conforming To Bs 4504 With Stainless Wire Mesh, Bolts, Nuts And Washers Etc Complete All As Specified And Directed By Engineer In Charge ( For Suction Side Balancing Tank ) . Make:- Frekline Hose / Tyco / Associated Enterprise 34 Providing And Fixing Multigrade Sand Filter Of Filter Flow Rate Of 80 M3 / Hr With A Filtration Velocity Of 15 M3 / Hr / M2 And Sized At 2400Mm Dia Filter Inlet And Outlet Ports Sized At 150Mm , 6Mm , 6 Mm Shell & Dish Thickness . Nmodel - Indion Mgf 2000 -2W Of Make Ion Exchange Nor Equivalent In Astral, Aqnanomis, Pent Air Nnotes: [ I ] Filtration Media Used For The Fine & Course Sand Media Combination Of Fine & Course / Pebbles - 5 Types Media, Specifically Suitable For Filtration With Uniform Coefficient Of 5 Layers Of Media – To The Quantity As Defined By The Filter Manufacturers-Total Media Quantity 9800 Kgs. N [ Ii ] Valve Battery - Frontal Piping Msep. N [ Iii ] Face Piping Of Msep With Butterfly Valves Of 150Mm Manually Regulated To Control Filtration Cycles. [ Make: Audco, Zoloto, Crawley & Ray, Thermax ] 35 Providing & Fixing Plumbing Work Consisting Of Upvc Pipes Sch-80, 10Kg / Cm2 With Pn 16 Grade Heavy Duty Fittings In To The Filtration Station And Discharge Pipework From The Filter To Floor Inlets Of The Pool Inlets Complete With All Heavy Duty Upvc Fittings And Adaptors Pasted Using Approved Solvent Cement & Testing To A Holding Pressure Of 3.5 Kg / Cm2 For A Period Of 6 Hours, As Per Specifications And Instructions Of The Engineer - In - Charge. Nmake: Finolex, Supreme, Prince N A ) 200Mm Nb 36 S & F Concrete Floor Inlet With Ss Screw Flow 12 M3 / Hr With 2 Female And Male Connection Pool Inlets White Abs Plastic Bottom Inlet For Concrete With S.S. Screws And Regulable Flow. Min. Flow / Inlet = 5, 000 Ltr / Hr Nmake : Astral Pool, Certikin, Ion Exchange. 37 Supply, Installation, Testing And Commissioning Of Main Drain Ss 304 Square Main Drain 450Mm X 450Mm With Main Frame Screwed On Base Frame Also In Ss 304 Duly Groutable On The Pool Bottom Deepest Part. The Drain Plate Should Be Able To Collect A Water Volume Of Not Less Than 35 M3 / Hr @ A Drain Velocity Of 1.0 M / Sec. The Hole Size On Drain Plate Not To Exceed 10 Mm And Qty Of Holes To Match The Said Flow. Contractor To Ensure That The Effective Surface Area Of Holes Shall Be Equal To Or More Than The Drain Pipe Size Effective Area Nmake : Astral Pool, Certikin, Ion Exchange 38 Hair & Lint Catcher - Hair Strainner - Size 500 Mm X 700 Mm - Ss 304 Make:- Ion Exchange / Uv Rich / Protcom / Astral Pool 39 Suction Trolly Sytsem, Trolly Mounted Suction Sweeper With , 600 Mm Ss Vaccum Head With - 2 Sets Of Nylon Brush & 30 Mt Long Vaccum Hose , Cleaning Accessaries- Algae Brush , Curved Brush, Leaf Rack , Leaf Skimmer , Starter , Cable & Starter . Etc. Complete. Make:- Astral Pool / Certikin / Pent Air / Ion Exchange 40 Supply, Installation, Testing And Commissioning Of Dosing Pump For Disinfectant Dosing Membrane Electronic Dosing Pump To Be Mounted Both On Its Base As Well As Hung On The Wall. Pumps Following Ce Regulations. Ip- 65 Protection. Required Power Connections Is 220 / 240V, 50 / 60 Hz. The Materials In Contact With Liquid Should Be : Polypropylene, Viton, Teflon And Pvc. Flow Rate Of Pump Shall Be 20Ltr / Hr @ 5 Bar. Nmake : Astral Pool, Certikin, Ion Exchange 41 Supply, Installation, Testing And Commissioning Of Solution Preparation Tank Semi-Transparent Polyethylene Tank With External Scale So That Levels Can Be Checked Easily, Capacity Of Tank Should Be 500 Litres Rested On The Finished Floor . The Above Doser Shall Suck The Chemicals From The Tank As Desired For The Pool Water Disinfection. Nmake : Astral Pool, Certikin 42 Supply, Installation, Testing And Commissioning Of Agitators For Easy Installation In The Tanks, Provided With Steering Grip In Bakelite, Rod And Propeller Arms In Pvc, Length Of Stirring Rod To Be Minimum 900 Mm Long So That The Chemicals In The Tank Can Be Stirred Properly. Nmake : Astral Pool, Certikin, Ion Exchange. 43 Chlorine / Ph Test Kit Along With Testing Liquid For Checking Ppm Level Minimum Quantity 12 Months On Basis 2 Test Per Day. Nmake : Astral Pool, Certikin, Ion Exchange, Uv Rich 44 Supply, Installation, Testing And Commissioning Ionization System For 8.0 Lacs Litres Of Water For Superior Control Of Algae And Bacterial Contamination In Pool Water By Introducing Copper And Silver Ions In Controlled Quantities By Electrolysis Method, With 2 Nos. Electrolyzing Chamber Ss-304 With Copper & Silver Electrode, Piping, Cabling & Equipped With An Electronic Control Panel Comprising Voltage Variation Devices, Ammeters, Auto Timers, Switches, Indicator Lights, Etc. Nmake : Astral Pool, Certikin, Ion Exchange, Uv Rich 45 Supply, Installation, Testing And Commissioning Of Overflow Gratings Overflow Gratings Of Size 250Mm Wide 24Mm Ht And Made In Abs / Pp And Able To Be Fixed On Straight As Well As Curved Channels . Corner Supports In Ss 304 To Be Supplied For Fixing At Four Pool Corners. Rate Shall Be Inclusive With Corner Supports Required In The Swimming Pool. Nmake : Astral Pool, Certikin, Ion Exchange. 46 Starting Blocks For Competition Pools. Adjustable Platform In Polyester And Fibreglass With Non-Slip Finish 500Mm X 500Mm. Complete With Fixing. Polished Finish With Height : 400Mm. Nmake : Astral Pool, Certikin, Ion Exchange. 47 Supply, Installation, Testing And Commissioning Of Factory Made, Cpri Type Tested, Indoor Cubical Compartmental Type Plant Room Panel Of Suitable Size, Conforming To Iec 61439-1 & 2 And Iec 61641, Having Both Sides Openable With Hinged Double Doors And Locking Arrangement, Ip 43 Protection Made Out Of 2.0 Mm Thick Mild Steel Crca Sheet, Supported And Fixed On Structural Frame Of Angle Iron Of Suitable Size, Including Earthing Stud, Labelling, Painting To All Internal & External Exposed Steel Surfaces With Powder Coating Paint ( 7 Tank Process ) , Duly Fixed In Ground With Pcc Foundation ( 1:2:4 ) Type B1, With Danger Notice Plate Of 1.6 Mm Thick Mild Steel Vitreous Enamelled ( White ) With Letters, Figures And Conventional Skull And Bones In Signal Red Colour Suitable For 3- Phase, 4 Wire System, 500 V Grade With Necessary Wiring, Pvc Sheathed Stranded Copper Conductor Of Appropriate Length And Size, Including Fixing Lugs, Bolts, Screws, Etc. Complete All As Specified And Directed By Engineer-In-Charge. Nmake: From Authorised Vender Of L & T, Schneider, Siemens, Legrand Nthe Panel Shall Comprise Of The Following: N [ A ] Busbar Chamber N [ I ] 01 Set ( 3L + N ) Of Copper Busbar Of Rated Capacity 160 A, Covered With Pvc Insulated Sleeves Including Insulator, Nuts, Bolts, Etc. With Complete Connection N [ B ] Incoming [ I ] 100 A, 415 V, Ics = 100% Icu = 25 Ka, 50 Hz Fp Mccb, Conforming To Iec 60947-2, Having Microprocessor Based Trip Unit, Adjustable Overload Setting ( 0.7 - 1 X In ) , Adjustable Short-Circuit Setting ( 5 - 10 X Ir ) , Adjustable Neutral Protection ( N, N / 2, Off ) , Front Indication Leds ( Ready, Overload And Pre-Alarm & Overload ) , Etc.- 01 Nos. N [ Ii ] Cl 1.0 Multi-Function Meter Capable Of Measuring V, A, F, Pf, W / Va, Wh / Vah, Runhrs. Onhrs & Interupts- 01 Nos. 48 [ Iii ] Led Phase Indicators ( Red, Yellow, Blue ) - 01 Set N [ B ] Outgoing [ I ] 40 A, 16 Ka, 415 V, 50 Hz Tp Mccb ( C -Curve ) , Front Indication Leds With Fully Automatic Star / Delta Starter Suitable For Main Circulating Pump, Complete With Contactors, Push Button ( S ) , Led Indicators, Auto / Manual Selector Switch, Overload Protection, Current Sensing Type Single Phase Preventer, Etc. Complete With All Accessories And Wiring, Etc.- 03 Nos. [ For Circulating Pump ] N [ Ii ] 32 A, 10 Ka, 230 V, 50 Hz Spn Mcb ( C -Curve ) - 01 Nos. [ For Plant Room Dbs ] N [ Iii ] 16 A, 10 Ka, 230 V, 50 Hz Spn Mcb ( C -Curve ) - 02 Nos. [ For Under Water Light ] N [ Iv ] 6 A, 10 Ka, 230 V, 50 Hz Sp Mcb ( C -Curve ) - 03 Nos. [ For Dosing Pump ] Nnotes: [ I ] 01 Nos. Of On / Off / Trip Status And Operations Counters As Well As Meters Shall Be Wired To Ethernet Gateway Part Of The Panel. N [ Ii ] The Bidder Shall Furnish Dimensional Drawings Of The Items Offered, Indicating All The Fittings, Dimensional Tolerances, Typical Gads, Etc. With Details Of Insulation At Each Point And Core Construction, Etc. For Approval Of The Garrison Engineer. N [ Iii ] The Bidder Shall Intimate The Garrison Engineer Of The Routine Tests In Accordance With Iec 61439-1 & 2 And Iec 61641 In The Oem Factory In Presence Of A Representative Nominated By The Garrison Engineer Before Dispatch. 49 M & L For 4 Core Pvc Insulated And Sheathed Industrial Flat Cables For Submersible Motor, Working Voltage Upto And Including 1100 Volts, As Per Is 694: 2010 ( For Panel To Motor Set Connecting ) Nmake : Rr Kabel, Havells, Finolex N ( A ) 4 Core, 16 Sqmm 50 M & L For Construction Of Fly-Ash Brick Masonary Valve Chamber Of Size 600 Mm X 600 Mm X 900 Mm ( Internal Dimenssions ) With Pcc Foundation 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate, 150 Mm Thick & 150 Mm Wide Offsets Around Over 100 Mm Thick Hardcore , 200 Mm Thick Fly-Ash Brick Masonry Walls Built In Cm 1:6, 100 Mm Thick Pcc 1:2:4 Type B1 Coping Finished Even And Smooth, Rendering 10 Mm Thick In Cement Mortar ( 1:6 ) Finished Even And Smooth, With Out Using Extra Cement Internally Including Top Of Floor Including Excavation Earth Work In Hard / Dense Soil 6 Mm Thick Ms Sheet Cover Fixed On 25 Mm X 25 Mm X 6 Mm Thick Angle Iron Frame With Hold Fasts Embedded In Pcc Coaping With Locking Arrangement, Mild Steel Handle And Painting To Steel Surfaces With Two Coats Of Synthetic Enamel Paint Over One Coat Of Primer Including Disposal Of Surplus Soil To A Distance Not Exceeding 50 M Etc Complete All As Specified And Directed. 51 External Water Supply Nsupply, Testing And Commissioning Of Centrifugal Pump Set Of Discharge Capacity 900 Lpm At 40 Mtr Head, Split Casing Type, 80X80mm Suction / Discharge And Coupled With Suitable Rating Induction Motor 3 Phase 415 Volts, 50 Hz Mounted On Ms Chanel / Common Base Plate And Fixed With Suitable Bolts, Grouted In Pcc Foundation, 30 Cm Above Floor Level Including Pvc Insulated Single Core Unsheathed Copper Conductor Of 06 Sqmm Size Drawn In Pvc Conduit For Connection From Starter To Motor Terminal. Make:- Kirloskar, Crompton Greaves, Beacon, Ksb. Note:- Provision For Priming System With 20Mm Gi Pipe And Control Valve Is Deemed To Be Included In Quoted Rate. N N 52 Supply, Laying And Jointing On Floor / Wall Class K9 Of Standard Length Double Flange ( Screwed ) Pipes, Internal Cement Mortar Coating An External Surface With Bituminous Paint Of Size 80 Mm Dia Isi All As Specified And Directed Nmake:Electrosteel / Jindal Saw / Tata Metaliks 53 Supply And Fix Foot Valve Ball Type Of 80 Mm Dia Flange Type Compele All As Specified And Directed. Make:- Kirloskar, Leader, Sant, Audco. 54 Supply, Laying And Jointing In Trenches Di Pipes Class K7 Of Standard Length Spigot And Socketed End Push Type Joint With Rubber Gasket As Jointing Material, Internal Cement Mortar Coating An External Surface With Bituminous Paint Of Size 100 Mm Dia Isi All As Specified And Directed. Nmake Electrosteel / Jindal Saw / Tata Metaliks 55 Material And Labour For Di Fittings And Fixtures Bends ( Any Type, Radius And Angle ) Tapers Any Type, ( Straight, Bend, Increasing, Decreasing Or Double Socket Etc. ) Tee Pieces Single Branch Y Junction, Double Branch, Cross ( All Sockets Or Socket And Spigot ) Collars, Cap And Plugs Upto 150Mm Bore 56 M&L For Lt Panel Board Cubical Kiosk Outdoor Type Compact 415 Vots Ac 50 Hz, 4 Wire +E, Fabricated Polycarbonate, Nominal Size 900Mmx600x660mm, Ral 7035 Finish Confirming To Ip 54 Complete Including Cu Bus Bar 100 Amps, 4 Strip Mounted On Porcelain Insulated Enclosed In Chamber, Bottom Cable Entry Comprising Of Foliowing N ( A ) Incoming Mccb 63 Amp 4 Pole With Microprocessor Based Release Having Breaking Capacity 36 Ka 01 Nos N ( B ) Outgoing Mccb 32 Amps 415 V, Triple Pole, 25Ka 02 No N ( C ) Digital Panel Meter For Amp, Volt, Kwh, Power Factor And Other Parameter Flush Mounting Of Size 96X96mm. N ( D ) Star Delta Starter Contactor, Push Buttons, Led Indicators Of Suitable Capacity Including Over Load Protection Single Phase Preventor Etc, Suiable For Pump Set - 02 Nos 57 S & F Ball Plug 200Mm Bore All As Specified & Directed. 58 S & F Well Cap 200Mm Size Threaded And Similar To Housing Pipe All As Specified & Directed N 59 S & F 2 Nos Ms Flat Iron 100Mm X 10Mm Thick Size Clamp For Holding With 250 Mm Bore Housing Pipe Including Casting Of Pcc Block Of Size 1200Mm X 1000Mm X 1000Mm In Pcc ( 1:2:4 ) Type B-1 Using 20 Graded Stone Aggregate Including 150Mm Bore Ms Pipe 2 No Each, 1.5 Metre Long With Cap Plug And Cap Top For Loading Pea Gravel For Each Bore Well As Specified And Directed. 60 Supply Only Strata Sample Box With Glass Cover 3Mm Thick Having Internal Dimension 100X100x600mm Made Out Of 20Mm Thick Wood With Hinges, Hasp And Staple Including Polishing Complete With Samples At Various Strata Met In Boring Including Strata Chartin Duplicate 61 Electric Logging In Pilot Bore For Precise Delineation Of Granular Zones As Also The Quality Of Ground Water Including Report Interpretation Complete As Specified Nnote: Electric Logging Shall Be Carried Out By Any Approved Govt Agency Or Geologist. 62 Material And Labour For Drilling Trial Bore Through Direct Hammering ( Dth ) Technique In Any Type Of Strata Consisting Of 250 Mm Dia Drill Bit For Depth Upto 200M In Sequence From Ground Level As Given Below For Bore Well Complete As Per Is-2800 Part-1 1991, The Following Tests And Reporting Will Be Carried Out By The Contractor And Approved By Ge As Per Is- 2800 Part 1 1991 :- N ( I ) Recording The Well Discharge During Drilling By A 90 Degree V Notch. N ( Ii ) Recording The Water Bearing Horizon. N ( Iii ) Taking The Samples From The Borewell Cutting For Every 3 Meter Interval And Every Change In Strata If Less Than 3 Meter. N ( Iv ) Preparation Of Litho Logs Based On These Samples. N ( V ) Drill Time Log To Be Prepared And Prescribed. N ( Vi ) Aquifer Performance Tests At Constant Discharge With Draw Down Nand Recovery Reading. N ( Vii ) Interpretation Of Data And Preparation Of Hydro Scientific Report For Designing Of Submersible Pump And Article Recharge Studies 63 Supply Assembling, Jointing, Lowering And Fixing In The Bore Hole Pvc Casing Pipe Of Nominal Dia 200 Mm ( Medium Well ) , 7.5 Mm Thickness Confirm To Is 12818-2010 Including Providing Pea Gravel Of 8Mm To 4.6Mm Size For Packing Around The Casing / Slotted Pipe In Bore Well As Specified And Directed Nmake : Astral / Ashirwad / Ajay 64 Supply Assembling, Jointing, Lowering And Fixing In The Bore Hole Upvc Slotted Pipe Of Nominal Dia 200 Mm ( Medium Well ) , 7.5 Mm Thickness Confirm To Is 12818-2010 Including Providing Pea Gravel Of 8Mm To 4.6Mm Size For Packing Around The Casing / Slotted Pipe In Bore Well As Specified And Directed Nmake : Astral / Ashirwad / Ajay 65 Developing The Tube Well By Means With 250 Psi Air Compressor All As Specified In Is-11180-1865 Para 4.3 And As Directed 66 Developing The Tube Well By Means Of Over Pumping All As Specified And As Directed. Nnote: Over Pumping Will Be Carried Out By Pumping The Well At Higher Capacity I.E. Not Less Than 50% Above The Yield Of Well 67 Yield Testing Of The Tube Well As Specified And Directed To Determine The Safe Pumping Capacity Of Tube Well 68 Supply, Installation / Lowering Submersible Pumpset, Discharge 150 Lpm And Head 80 M. Electric Driven, 415 V, Tp Suitable For 200 / 250 Mm Dia Borewell, Stainless Steel Body, Water Filled Fitted With Non Return Valve To Prevent Backflow, With Suitable Capacity Of Starter Panel And Submersible Copper Cable Of Rating As Per Manufacturer ( Trom Panel To Submersible Motor, Length Of Cable As Per Site Requirement ) All Specified And Directed By Engineer-In Charge. Nmake Crompton Greaves / Ksb / Kirloskar Brothers / Texmo 69 Supply & Fix Pump Guard Set With Flange 63Mm All As Specifed. 70 Supply, Assembling, Jointing. Lowering Lead Free Upvc Column Pipes Of Nominal Dia 65 Mm, Od 75 Mm ( Min ) , Non Toxic, Pressure 26 Kg / Cm2 With And Including Top And Bottom Adaptor ( Ss ) And Accessories Like Epdm Ring And Double Ss Stud All As Specified And Directed By Engineer-In-Charge. Nmake : Astral / Ashirwad / Ajay 71 Supply And Fix Pp-R Pipes Sdr 6 ( Pn-20 ) And Pp-R Plain Fittings In Trenches / Walls / Ceilings Or Laying In Floors Complete Of Following Sizes Including Fittiings N ( A ) 90 Mm Outer Dia 72 ( B ) 50 Mm Outer Dia 73 ( C ) 32 Mm Outer Dia 74 Material And Labour For Construction Of For Valve Pit / Chamber In Pcc Solid Block Masonry ( 1:5:8 ) Built In Cm 1:6 Over 150 Mm Thick Pcc Loundation 1:3:6 Type C2, 10Mm Thick Intemal Cm 1:6 & 12Mm Thich External Plaster In Cm 1:4 Provided With 3 Mm Thick Ms Sheet Cover And Ms Angle Iron Chamber Frame Fixed In Coping In Pcc 1:2:4 Type B-1 With Locking Arrangement And Handle, Painting Of Ms Work With One Coat Of Red Oxide Primer And Two Coat Of Synthetic Enamel Black Paint Complete Including Excavation & Earth Work In Any Type Of Strata Complete All As Shown An Drawing No.Ceaa / Td / 57 Sheet No 1 / 1, Dated 28 05.92 Amended Upto 31.12.92, But Of Internal Size 1050Mm ( L ) X 750Mm ( B ) X 1000Mm ( D ) Etc Complete All As Specified Arid Directed. N Note:- Excavation, Return Filling And Removal Of Soil Etc Is Deemed To Be Inclusive In Quoted Rate. 75 M & L For Geoelectric Investigation For Groundwater Assembly By Sophisticated Digital Deep Resistivity Monitors On Suitabie 3 Spot 150 M Depth To Delineate Saturated Thickness, Extent Of Fracturing At Deeper Level To Analyze Quantitative And Qualitative Potential Of The Area & To Including Calibration To Determine The Aquifer System Of The Area & To Determine Quantity And Quality At Each Side And Select Suitable Site For Tube Well With Salinity Level. Nnote Cost Of Mobilization Of Equipment / T & P And Preparation Of Report Included In Item Rate. N 76 External Electrification Nsupply And Lay Double Wall Corrugated ( Dwc ) High Density Polythene Pipes Of Nsize 90 Mm Od ( Nominal ) With All Fittings Having Corrugation On The Outer Wall And Plain Surface On The Inner Wall Confirming To Is 14930 ( Part I And Ii ) For Protection Of Underground Cables Laid In Trenches / Road / Nallah Or Fixed Along Wall, Poles Or Laid Under Floor Including Cutting Floor / Road And Making Good To Match With Existing Adjoining Surface Etc For Cable Protection All As Specified ( Excavation And Earth Work Shall Be Measured And Paid Separately ) N Make Rex / Poly / Gemini N 77 Supply And Fix Octagonal Hot-Dip Galvanized Street Light Poles Including Junction Box, Height 7 Mtrs, Top Dia 70Mm, Bottom Dia 130 Mm, Sheet Thickness 3 Mm, Base Plate 220X220x12, Foundation Nut Bolts As Per Manufacturer Recommendation Including Reinforced Cement Concrete Foundation And Hot Dip Galvanised Bracket Single Arm For Fixing Of Street Light And One No Of Mcb 6 Amp Including 25 Amp Four Way Terminal Block All As Specified And Directed. Nmake: Bajaj Surya / Philips / Utkarsh 78 Supply & Fix Led Lights, Nominal Watt 150 Watt, Nominal Lumen Efficancy 90 Lumen / Watt, High Pressure Die Cast Aluminium Housing, 140-270V, 50 Hz. Pf>0.95 Led Flood Light Luminaries Mounted On Wall Complete All As Specified And As Directed By Engr-In Charge. N Make: Philips / Wipro [ Skyline ) Lf20-192 060-57-Xx / Osram ( Strada Plus ) N 79 Supply & Fix Led Lights, Nominal Wat 30 Watt, Nominal Lumen Efficancy 90 Lumen / Watt, High Pressure Die Cast Aluminium Housing, 140-270V. 50 Hz. Pf>0.95 Led Street Light Luminaries To Be Mounted On Octagonal Hot-Dip Galvanized Street Light Poles Including 3 Core 1 Sqmm Pvc Insulated Copper Cable From Control Box To Fitting Complete All As Specified And As Directed By Engr-In Charge Nmake: Philips ) / Wipro ( Skyline ) Lro2-331 Xxx57 / Osram ( Strada Plus ) 80 Supply And Lay Double Wall Corrugated ( Dwc ) High Density Polythene Pipes Having Corrugation On The Outer Wall And Plain Surface On The Inner Wall Confirming To Isi 14930 ( Part I And Ii ) For Protection Of Underground Calbes Of Size 63 Mm Outer Dia With All Fittings. Laid In Trenches / Road / Nallah Or Fixed Along Wall Poles Or Laid Under Floor Including Cutting Floor / Road And Making Good To Match With Existing Adjoining Surface Etc For Cable Protection All As Specified ( Excavation And Earth Work Shall Be Measured And Paid Separately ) Nmake: Rex / Poly / Gemini 81 Supply And Fix Time Switches 415V 3 Phase 5 Kw With Contactor Fitted Inside Steel Enclosure Including Incoming And Out Going Mcbs, Power Contactors And Smc Enlosure For Encasing Complete 3-Phase Circuit Board Along With Nature Switch-02 All As Specified And Directed By Engineer-In-Charge. Nmake:- Swadeep, L&T, Abb, Bajaj 82 Outsourcing Of Services For Operation Of Swimming Pool Including Connected Machineries And Controlled Valves For Two Shifts And Each Shift Of 08 Hrs I.E. 0600 Hrs To 1400 Hrs And 1400 Hrs To 2200Hrs On All Working Days Including Sunday And Holidays With One Operator Per Shift And Keeping Installation Neat And Clean For Trouble Free Operation Including Maintaining Water In Appropriate Norms By Mixing Tcca-90, Calcium Hypochlorite, Alum, Copper Sulphate Etc An Cleaning The Bottom And Sides Of The Pool By Suction Sweeper Whenever Necessary All As Directed By Engr-In-Charge. Nswimming Pool Plant Details: Na ) Filtration Plant Capacity – 80 M3 / Hr Nb ) Centrifugal Pump ( 03Nos ) - 80 M3 / Hr Nc ) Sand Filter ( O2 Nos ) Nd ) Chlorine Dosing Pump ( 03 Nos ) Ne ) Centrifugal Pump 900 Lpm 30 M Head ( 02 ) Nos N Nnote:- N ( I ) Contractor Will Submit The Nominal Roll, Qualification Certificate / Experience Certificate Of Operator Before Commencement Of Outsourcing. N 83 ( Ii ) The Operator Shall Be Iti Qualified In Respective Trade Or Shall Have Minimum 2 Years Experience In Operation Of Swimming Pool. N ( Iii ) Contractors Will Ensure Attendance Of All Operators Shift Wise, If Any Operator Found Absent From Duty A Recovery Of Double The Rate Quoted By The Contractor Against Each Shift / Item Shall Be Made. N ( Iv ) The Tradesman / Operator Should Maintain Proper Hygiene Of Swimming Pool As Instructed By Je E / M In Charge. He Should Have Sufficient Knowledge About Pool Water Chemistry. The Operator Should Maintain The Daily Log Sheet Of The Pool As Instructed By The Concerned Je E / M. In Addition To Running The Plant His Duty Includes Mixing Of Sufficient Chemical In The Swimming Pool / Balancing Tank And Maintaining The Water In Its Standard Level By Controlling Ph Value Between 7.2 To 7.6 And Free Chlorine Value Not Less Than 1Ppm As Per Is 3928-1993. N ( V ) Necessary Pool Chemicals Such As Tcca-90, Calcium Hypochlorite, Alum, Copper Sulphate Etc Will Be Supplied By The Department As Supply Only. N N ( Vi ) All Necessary T&P Including Uniform Shall Be Provided By Contractor To The Operator At No Extra Cost. The Rates For The Same Are Deemed To Be Included In The Unit Rates Of The Item. N ( Vii ) The Contractor Will Provide All The Necessary Stationery Such As Log Book, Attendance Register Etc To The Operator For Maintaining The Plant Running Record. N ( Viii ) All Operator Shall Wear Proper Uniform. N

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-05-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-05-2021

Key Value

Document Fees
INR 2000 /-
EMD
INR 407000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail