}

Dehumidification And Temperature Control In Equipments Of Refinery-Iii Units During Refinery-Iii M And I Shutdown-2021, CPCL, Manali - Chennai.-Tamil Nadu

Chennai Petroleum Corporation Limited has published Dehumidification And Temperature Control In Equipments Of Refinery-Iii Units During Refinery-Iii M And I Shutdown-2021. Submission Date for this Tender is 20-04-2021. Dehumidifiers Tenders in CPCL, Manali - Chennai. Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

27504905
Corrigendum : Dehumidification And Temperature Control In Equipments Of Refinery-Iii Units During Refinery-Iii M And I Shutdown-2021
Open Tender
Indian
Tamil Nadu
Cpcl, Manali - Chennai.
20-04-2021

Tender Details

Dehumidification And Temperature Control In Equipments Of Refinery-Iii Units During Refinery-Iii M And I Shutdown-2021 , Dehumidification And Temperature Control , Dehumidification And Temperature Control In Equipments Of Refinery-3 Process During Refinery-3 M&I Shutdown-2021 . , Hiring Of Dehumifier - Volumn Less Than 150 Cum Dehumidification & Temp . Control At Dr Volume Of Equipment Shall Be Less Than 150 Cubic Meter ( I . E 150Cubic Meter Is Excluded ) Dehumidifier And Temperature Control Unit To Control Moisture , Humidityand Temperature During Maintenance/Inspection Of Column . Relative Humidity Will Be Maintained In The Column Between 50% To 55%And Temperature From 26 To 28 Degree Celsius At The Outlet Of The Duct . , Mobilization Of Dehumidification System/Manpower ( For Volume Less Than 150 Cubic Meter ) Charges Are Inclusive Of Installation Of System And Trial Run ( If Any ) In Equipment , Boarding , Loading And Transportation Charges Of Manpower And All Other Incidental Expanses . Unit Of Measurement Is Each Which Implies That One Time Mobilisation Shall Be Considered As 1 For Each Dehumidification System . , De-Mobilization Of Dehumidification System/Manpower ( For Volume Less Than 150 Cubic Meter ) Charges Are Inclusive Of Removal Of System From Equipment / Cpcl Site , Removal Of Scrap If Any , Boarding , Loading And Transportation Charges Of Manpower / Equipment And All Other Incidental Expanses . Unit Of Measurement Is Each Which Implies That One Time Demobilisation Shall Be Considered As 1 For Each Dehumidification System . , Rental Charges For Dehumidification System / Man Power ( For Volume Less Than 150 Cubic Meter ) Rental Charges Of Machines /Manpower Will Be Counted For The Period Of Utilization Of Dehumidifcation System . Time Taken For To & Fro Transportation , Installation/De-Installation , Trial & Commissioning Of Machines Shall Not Be Considered For Payment Of Rental Charges . Period Of Utilization Shall Be Certified By Eic/Site Engineer On Daily Basis . Unit Of Measurement 01 Day = 24 Hrs . Utilization Of Each Dehumidification System Supplied By Vendor For Above Mentioned Volume Irrespective Of Number Of Columns Connected To That System . , Hiring Of Dehumifier - Volumn 150 Cum To 500 Cum Volume Of Equipment Shall Be From 150 To 500 Cubic Meter ( I . E 150 Cubic Meter Is Included And 500 Cubic Meter Is Excluded ) Dehumidifier And Temperature Control Unit To Control Moisture , Humidity And Temperature During Maintenance/Inspection Of Column . Relative Humidity Will Be Maintained In The Column Between 50% To 55% And Temperature From 26 To 28 Degree Celsius At The Outlet Of The Duct . , Mobilization Of Dehumidification System/Manpower ( For Volume From 150 Upto 500 Cubic Meter ) Charges Are Inclusive Of Installation Of System And Trial Run ( If Any ) In Equipment , Boarding , Loading And Transportation Charges Of Manpower And All Other Incidental Expanses . Unit Of Measurement Is Each Which Implies That One Time Mobilisation Shall Be Considered As 1 For Each Dehumidification System . , De-Mobilization Of Dehumidification System/Manpower ( For Volume From 150 Upto 500 Cubic Meter ) Charges Are Inclusive Of Removal Of System From Equipment / Cpcl Site , Removal Of Scrap If Any , Boarding , Loading And Transportation Charges Of Manpower / Equipment And All Other Incidental Expanses . Unit Of Measurement Is Each Which Implies That One Time Demobilisation Shall Be Considered As 1 For Each Dehumidification System . , Rental Charges For Dehumidification System / Man Power ( For Volume From 150 Upto 500 Cubic Meter ) Rental Charges Of Machines /Manpower Will Be Counted For The Period Of Utilization Of Dehumidifcation System . Time Taken For To & Fro Transportation , Installation/De-Installation , Trial & Commissioning Of Machines Shall Not Be Considered For Payment Of Rental Charges . Period Of Utilization Shall Be Certified By Eic/Site Engineer On Daily Basis . Unit Of Measurement 01 Day = 24 Hrs . Utilization Of Each Dehumidification System Supplied By Vendor For Above Mentioned Volume Irrespective Of Number Of Columns Connected To That System . , Hiring Of Dehumifier - Volumn 500 Cum To 1200 Cum Volume Of Equipment Shall Be From 500 To 1200 Cubic Meter ( I . E 500 Cubic Meter Is Included And 1200 Cubic Meter Is Excluded ) Dehumidifier And Temperature Control Unit To Control Moisture , Humidity And Temperature During Maintenance/Inspection Of Column . Relative Humidity Will Be Maintained In The Column Between 50% To 55% And Temperature From 26 To 28 Degree Celsius At The Outlet Of The Duct . , Mobilization Of Dehumidification System/Manpower ( For Volume From 500 To 1200 Cubic Meter ) Charges Are Inclusive Of Installation Of System And Trial Run ( If Any ) In Equipment , Boarding , Loading And Transportation Charges Of Manpower And All Other Incidental Expanses . Unit Of Measurement Is Each Which Implies That One Time Mobilisation Shall Be Considered As 1 For Each Dehumidification System . , De-Mobilization Of Dehumidification System/Manpower ( For Volume From 500 To 1200 Cubic Meter ) Charges Are Inclusive Of Removal Of System From Equipment / Cpcl Site , Removal Of Scrap If Any , Boarding , Loading And Transportation Charges Of Manpower / Equipment And All Other Incidental Expanses . Unit Of Measurement Is Each Which Implies That One Time Demobilisation Shall Be Considered As 1 For Each Dehumidification System . , Rental Charges For Dehumidification System/ Man Power ( For Volume From 500 To 1200 Cubic Meter ) Rental Charges Of Machines /Manpower Will Be Counted For The Period Of Utilization Of Dehumidifcation System . Time Taken For To & Fro Transportation , Installation/De-Installation , Trial & Commissioning Of Machines Shall Not Be Considered For Payment Of Rental Charges . Period Of Utilization Shall Be Certified By Eic/Site Engineer On Daily Basis . Unit Of Measurement 01 Day = 24 Hrs . Utilization Of Each Dehumidification System Supplied By Vendor For Above Mentioned Volume Irrespective Of Number Of Columns Connected To That System .

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-04-2021 Corrigendum No.1 for Dehumidification and Temperature Control in Equipments of Refinery-III Units during Refinery-III M and I Shutdown-2021 Date 20-04-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail