Repair / Maintenance And Improvement Of E / M Installation Repair Of Dg Sets Pump Motor And Misc E / M Equipments And Plants At Alhilal Mil Stn-1 Excavation In Trenches Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M In Depth For Foundation Etc Or For Laying Of Cables, Errection Of Poles, Struts / Stays Etc Including Taking Out Cable Cover Or Stone Slab, Not Exceeding 10 Sqm On Plan And Getting Out In Any Type Of Soil Complete All As Specified And Directed. 2 Excavation In Trenches Not Exceeding 1.5 M Wide And Exceeding 1.5 M But Not Exceeding3.0 M In Depth For Foundation Etc Or For Laying Of Cables, Errection Of Poles, Struts / Stays Etc Including Taking Out Cable Cover Or Stone Slab, Not Exceeding 10 Sqm On Plan And Getting Out In Any Type Of Soil Complete All As Specified And Directed. 3 Returning Filling In Including Spreading Leveling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Any Type Of Soil Complete All As Specified And Directed. 4 Removing Excavated Any Type Of Soil To A Distance Not Exceeding 50 M And Depositing Where Directed, At A Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified And Directed. 5 M&L Sand Cushioning To Undergound Cable With Using Fine River Sand And Gently Punning For Cushioning To Cable Complete All As Specified And As Directed. Nnote:-For The Purpose Of Payment Only Punned Thickness Will Be Measured. 6 M&L Old Size Brick Class B As In Cable Protection Laid Dry, Flat, Transversally Along The Length Of Cable On Sand Cushioning With Width Equalto Length Of The Brick Complete All As Specified And As Directed. N 7 M&L Pcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Crushed Stone Aggregate For Pedestal Including Necessary Formwork And Fair Finishing To Exposed Surface Without Using Extra Cement Complete All As Specified And Directed. 8 M&L Cement Concrete ( 1:3:6 ) Type C2 Using 40Mm Graded Crushed Stone Aggregates For Foundation Of Poles / Struts / Stays Etc Complete All As Specified And Directed. 9 S&F Steel Tubular Swaged Pole Complete With Cast Iron Base Plate, Finial Taper Plug, Bolt, Nut And Screws As Specified 410 Sp-31 ( 9 Mter Long ) Including Taking Down Old Damaged Pole Of Any Type And Size, Including One Coat Of Red-Oxide Zinc Chrome Primer And Two Coats Aluminium Paint On Surfaces, Exposed To View And Making 30Cm Wide Strips ( Total 5 Nos ) With Yellow And Black Paint Alternately On External Surface, Above Pcc Benching Including With Writing Of Pole No With Letters / Figures Of Size Not Exc 30 Mm With Black Paint On A Yellow Circle Of Dia 75 Mm After Painting Complete All As Specified And Directed. 10 Painting To Existing Steel Tubular Lt Poles, 9M / 11M Long Including Cross Arms, Channels, Angle Iron Support, Bracings, Clamps Etc, With Two Coats Of Aluminium Paint Superior Quality Of Approved Make On Surfaces Exposed To View And Making 30Cm Wide Strips ( Total 5 Nos ) With White And Black Paint Alternately On External Surfaces Above Pcc Benching Including Preparation Of Old Painted Surfaces By Scraping Etc Complete All As Specified & Directed. 11 Trimming Of Tree Branches From Lt Overhead Line To Branch 2 Mtr Up To Both Side & Re-Stretching Of Acsr Conductor And Earth Wire Of Any Size And Type On Lt Poles Including Disconnecting And Rebinding With Insulators With Suitable Size Of Binding Wire After Restretching, Connecting Jumpers, Adjusting Line Deviders And Disposal Tree Branches As Per Direction By Engr-In-Charge Complete Including Removing And Refixing Of Ug Cable / Service Wires To The Acsr Conductor Complete. ( Note- Pole To Pole Length Shall Be Measured And Paid As One Run ) 12 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 120Sq.Mm 3 1 / 2Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 13 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 95Sq.Mm 3 1 / 2Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 14 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 70Sq.Mm 3 1 / 2Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 15 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 50Sq.Mm 3 1 / 2Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 16 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 35 Sq.Mm 3 1 / 2Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 17 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 25 Sq.Mm 3 1 / 2Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 18 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 16 Sq.Mm 4 Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 19 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 10 Sq.Mm 4 Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 20 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 16 Sq.Mm 2 Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 21 Supply And Laying Or Fixing Or Passing Through Pipe Or Laid In Trenches, 1100 Volt Grade Heavy Duty Cable Xlpe Insulated, Armoured Electric Cable With Aluminium Conductor , Cross-Sectional Area 10 Sq.Mm 2 Core Including Taking Out Old Unserviceable Cable Complete All As Directed By Engineer-In-Charge. 22 S&F 80Mm Bore Galvanised Iron, Light Grade ( Isi Marked ) Laid In Trenches / Fixed On Wall / Poles Etc For Protection Of Cable, Including Taking Out Old Tubing Complete All As Specified And As Directed. 23 S&F 50Mm Bore Galvanised Iron, Light Grade ( Isi Marked ) Laid In Trenches / Fixed On Wall / Poles Etc For Protection Of Cable, , Including Taking Out Old Tubing Complete All As Specified And As Directed. 24 S&F 40Mm Bore Galvanised Iron, Light Grade ( Isi Marked ) Laid In Trenches / Fixed On Wall / Poles Etc For Protection Of Cable, , Including Taking Out Old Tubing Complete All As Specified And As Directed. 25 M&L 25X20cm Size Ht Danger Notice Plate Of 1.60Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters, Figures And Conventional Skull And Bones In Single Red Colour And Fixed With M.S Clamps, Bolts And Nuts Including Taking Down Existing Rusted Danger Notice Plate Complete All As Specified And Directed. 26 Cutting And Removing Existing Wild Grass, Vegetation, Creepers, Small Plants / Bushes Etc Clamping Up Towards The Poles And Stays Etc Including Cleaning Bottom Surface Area Of Pole &Stay Not Less Than 1M X 1M By Surface Dressing Of Earth Outside And Inside Substations, Perimeter Fencing Around Pump House Area, And In Drains Surrounding Area From Site Complete All As Specified And Directed By Engineer-In-Charge. 27 Supply And Replacement 3 Phase Highly Insulated Frp Telescopic Earth / Discharge Rod 11Kv With Following Specification Rods-03 Nos, Material-Frp Pultruded, Pross-Automatic Pultrusion Plant, Surface-Smooth And Glossy, Locking-Push Button Type Locking System, Total Section Of Each Rod-03 Section, Assembled Length-15 Feet H.V.Test 110Kv, Glass Content-65%, Top Section Dia 25Mm, Bottom Section Dia-45Mm, Earthing-Die Cast Aluminium.Earthing Instrument For 30Mm Dia, Cable-4Sqmm Copper Cable 06 Mtr Long, Clamp-Crocodile Grouting Clamp Including Cover Complete All As Specified And Directed. 28 Supply And Fix In Replacement Mccb, Ac, 415Volts, 63 Amp, 16Ka, 4 Pole, Adjustable Thermal Magnetic Release Including Making Necessary Connection In Existing Panel Complete All As Specified And Directed. 29 Supply And Fix In Replacement Mccb, Ac, 415Volts, 125 Amp, 25Ka, 4 Pole, Adjustable Thermal Magnetic Release Including Making Necessary Connection In Existing Panel Complete All As Specified And Directed. 30 Supply And Fix In Replacement Mccb, Ac, 415 Volts, 160 Amp, 25 Ka, 4 Pole, Adjustable Thermal Magnetic Release Including Making Necessary Connection In Existing Panel Complete All As Specified And Directed. 31 Supply And Fix In Replacement Mccb, Ac, 415Volts, 200 Amp, 35 / 36Ka, 4 Pole, Adjustable Thermal Magnetic Release Including Making Necessary Connection In Existing Panel Complete All As Specified And Directed. 32 Supply And Fix In Replacement Mccb, Ac, 415Volts, 250 Amp, 35 / 36Ka, 4 Pole, Adjustable Thermal Magnetic Release Including Making Necessary Connection In Existing Panel Complete All As Specified And Directed. 33 Supply And Fix In Replacement Mcb, Tpn 63 Amps, Ac, 415 Volts, C Curve, Including Making Necessary Connection In Existing Panel Complete All As Specified And Directed. 34 Supply And Spreding Graded Crushed Stone Aggregate 40Mm Size Around Two Pole / Four Pole Structure In 15 Cm Thickness After Cleaning Area By Removing Existing Wild Grass, Vegetation, Creepers, Small Plants / Bushes Etc Complete All As Specified And Directed. 35 M&L Preparation Of Old Steel Surfaces Of Any Description Not Otherwise Described, Over 10 Cm Width Or Girth And Applying One Coat Of Synthetic Enamel Paint Of Approved Tint, Complete All As Specified And Directed. 36 Supply, Fix , Connecting And Testing Of Energy Efficient, Decorative Post Top For Garden And Landscape Lighting Ip 66 Potection, Resistant To Impact And Corrosion Glare-Free And Batter Uniformityned With Heat Resistant Toughened Glass Led Light Luminaries 30Watt Including Taking Down Unserviceable Light Fitting Complete All As Specified And Directed By Engineer-In-Charge..Make : Havells, / Halonix / Bajaj / Philips / Cg 37 Taking Down Old Un-Serviceable Air Termination Rod, M&L Air Termination , Single Pointed Aluminium Rod 12Mm Dia And 300Mm Long Complete All As Specified And Directed. 38 Taking Down Old Un-Serviceable Insulator Of Any Type And Size, S&F Epoxy Base Insulator Of Size 40 Mm Fixed To Wall , Pcc Block Angle Iron Or Any Other Location Complete All As Specified And Directed. 39 Taking Down Old Un-Serviceable Aluminium Strip Of Any Type And Size , M&L Aluminium Strip 25X3.15Mm With Saddles And Fixing Screws Etc For Roof Conductors And Down Conductors Above Ground Level Complete All As Specified And Directed. 40 M&L Earthing Complete With Galvanized Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Ground Level ) With Top Edge Of Plate Not Less Than 1.5 Metre Below Normal Ground Level Connected To Galvanized Earth Lead Strip 32Mmx6mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No 3 Of Mes Ssr Part-I Connected To Main Switch Board Or Main Control Board All As Specified And Testing On Completion Including Provision Of Earth Strip Protected By Galvanized Iron 40 Mm Dia Light Grade Pipe And Watering Pipe Shall Be 20 Mm Bore Light Grade Including All Excavation And Earth Work In Any Type Of Soil, Pcc Pit With Pre-Cast Rcc Cover, Charcoal / Salt, Funnel Etc Including Taking Out Old Un-Serviceable Earthing, Complete All As Directed By Engineer-In-Charge. Nnote: ( I ) The Concrete Pit Shall Be Pcc 1:3:6 Type C-1, 40Mm Thick Pre-Cast Cover Slab Of Rcc ( 1:2:4 ) Type B-1 Using 20Mm Graded Crushed Stone Aggregate, Reinforced With 8Mm Tmt Bars @ 10 Cm C / C On Both Sides With Suitable Cast Iron Handle Shall Be Provided In Lieu Of Cast Iron Cover Shown In Electrical Plate No. 3 Of Mes Ssr Part-I., ( Ii ) Item Includes The Cost Of Gi Pipe Up To 7.5M Gi For Protection Of Earth Strip & ( Iii ) Pcc Pit Shall Be Provided At Least 500 Mm Away From The Pit And Not On The Earth Pit Itself And The Extra Cost Of Additional Length Of Watering Pipe, Bends, Elbow Etc Shall Be Deemed Included In The Unit Rate. 41 M&L , Monthly Inspection, Maintenance And Serviceing Of Dg Sets Of The Following Capacities Including Alternator, Electric Panel Board Connection To Dg Set For Routine Check ( A Check ) Of Dg Set For Smooth Functioning And Carrying Out Maintanance As Directed As Specified For The Following Dg Sets :- N ( A ) 62.5 Kva Capacity, Make: Cummins, - 01 No ( B ) 40 Kva Capacity, Make: Cummins-01 No N ( I ) Checking Engine Oil Level And Topping Up As And When Required . Note ( I ) Oil Shall Be Measures And Paid Separately ( Ii ) Checking And Adjusting The Belt For Tension And Replacement Of Belt. Note : Belt Shall Be Measured And Paid Seperately ( Iii ) Checking Of Air Filter Element N ( Iv ) Checking Of Exhaust System For Leakage N ( V ) Draining Of Sediment From Fuel Filter And Fuel Tank N ( Vi ) Cleaning Of Air Cleaner Element N ( Vii ) Checking Engine Alternator Coupling, Mounting Bolts And Alignment N ( Viii ) Tighting All Nuts, Bolts, In Altenator Terminal Block N ( Ix ) Checking Of Alternator Carbon Brush And Connections In Alternator N ( X ) Checking And Tighting Of All Connection In Dc Control Wiring. For Further Note Please Refer Ps 42 M&L Required For Inspection, Maintenance And Servicing Of Dg Sets Of Following Capacities Including Alternator, Electric Panel Board Connection To Dg Set For Routine Check ( B - Check ) Of Dg Set For Smooth Functioning And Carrying Out Maintanance Complete All As Directed And Specified. Nnote: ( I ) B-Check Once In Six Month Or 250 Hrs Running Of Dg Set Whichever Is Earlier. N ( Ii ) B- Check Of All Dg Sets Ones Shall Be Paid As One Job ( Iii ) All Spare Parts Required Shall Be Measured And Paid Separately As Supply Only N ( A ) 62.5 Kva Capacity, Make: Cummins, - 01 No ( B ) 40 Kva Capacity, Make: Cummins-01 No Nnote :For Further Note Please Refer Ps N N 43 Supply Only Diesel Filter ( Primery&Secondary ) Suitable For 62.5 Kva Dg Set 44 Supply Only Diesel Filter ( Primery&Secondary ) Suitable For 40 Kva Dg Set 45 Supply Only Engine Oil Filter Suitable For 62.5 Kva Dg Set 46 Supply Only Engine Oil Filter Suitable For 40 Kva Dg Set 47 Supply Only Fuel Flexible Pvc Pipe Wire Braded Of Existing Size And Make Approved Quality. 48 Supply Only Oil Pressure Gauge Of Approved Make. 49 Supply Only Oil Pressure Switch Of Approved Make. 50 Supply Only Water Temperature Gauge Of Approved Make. 51 Supply Only Ignition Switch Of Approved Make. 52 S&F Asbastus Rope, ( 8Mm Dia Of Superior Quality ) Wrapping To The Cylincer Pipe Of Dg Set Of Cap 62.5 Kva Including Winding With 2Mm Dia Gi Wire And Provide White Cement / Plaster Of Paris To Asbastus Rope For Smooth Finish Including Taking Down Old Unserviceable Rope Complete All As Specified And Directed. 53 Taking Out Fuel Injecting Pump From 40 / 62.5 Kva Dg Set And Complete Repair Of Pump And Re-Fix In Same Position And Testing Complete All As Specified And Directed. 54 Taking Out Self Starter From 40 / 62.5 Kva Dg Set And Complete Repair Of Pump And Re-Fix In Same Position And Testing Complete All As Specified And Directed. 55 Taking Out Dynmo With Assembly From 40 / 62.5 Kva Dg Set And Complete Repair Of Pump And Re-Fix In Same Position And Testing Complete All As Specified And Directed. 56 Servicing And Repair Self Starter 12 V For Dg Set Incl Replacement Of Parts Such As Corban Brushes, Solonaid, Rotor, Washer, Nut, Bolts Etc Assembling The Same And Testing Complete All As Specified And Directed By Engineer In Charge. 57 Dismantling The Radiator And Fan From The Engine For Cleaning Of Copper / Aluminium Tubes And Cooling Fins By Using Descaling Solution ( Mac Solution ) And Soldering, Patch Work If Required Including Repair Of Water Pump Assembly And Replacement Of Defective Parts Of Water Pump And Re-Assembliying, Testing Complete 62.5 / 40 Kva Dg Set Complete All As Specified And Directed By Engineer In Charge. Note : Fan Blade Shall Be Measured Seprately As Supply Only. 58 Supply Only Radiator Fan Blade Suitable For 40 / 62.5 Kva Dg Set Complete All As Specified And Directed. 59 M&L For Repair And Servicing Of Wate Pump For Radiator Of Dg Set Suitable For 62.5 Kva Dg Set Complete All As Specified And Directed. Note : All Spare Required For Repair Of Pump Included In This Item. 60 Supply & Fix In Replacement Of Unserviceable Battery 12 V, 180 Ah With Maintenance Free Battery 12 Volt Initially Charged. Nmake :- Exide / Amron / Luminous 61 Supply Only Battary Charger In Amf Panel Of Approved Make. 62 Supply Only Battery Terminal Heavy Duty Of Brass With Nuts And Bolts Of Approved Make. 63 Supply Only Distilled Water Of Approved Make. 64 Supply Only Coolant For Raditor Of Approved Make. 65 Supply Only 20W 40 / 15 W 40 Turbo Synthetic Superior Quality Engine Oil Nmake : Kirloskar / Catrol / Volvoline / Servo / Hp / Ioc Note:- Contractor Has To Supply Engine Oil Of Make As Recommened By Dg Set Manufacturer 66 Supply Only Fan Belt Of Suitable Size For 40 / 62.5 Kva Dg Set Compete All As Specified And Directed. 67 S&F Changeover Switch With Sheet Matel Encloser 4 Pole Flush Mountain, Front Openable 415 Volt, 125 Amp Including Taking Down Unserviceable Changeover Complete All As Specified And Directed. 68 Taking Out Submersible Pump From Bore Well , Dismantling Existing Pump Set, 7.5 Hp Electric Driven 3 Phase 415 Volts After Disconnecting Electric Connection And Transporting The Same Workshop For Repair And Lowering The Same After Repair And Making Electric Connection Including Testing Complete All As Specified And Directed By Engineer-In-Charge. Nnote: Replacement Items Shall Be Measured And Paid For Separately 69 Taking Out Burn Out Winding And Rewinding The Submersible Motor 7.5 Hp 3 Phase 415 Volts With Super Enameled Copper Wire Of Appropriate Gauge Including E Class Insulation Material, Varnishing And Balancing Rotor Connection And Testing To Entire Satisfaction Of Engineer-In-Charge. 70 M&L Submersible Flat Copper Conductor Cable 1100 Volts Grade To Is 694 / 1990 Size 6 Sqmm 3 Core Complete Including Taking Out Unserviceable Cable Complete All As Specified And Directed. 71 S&F Automatic Star Delta Starter For 15 Hp Motor With Overload Relay Of Range 10-16 Amps , Power Contractors Ml-1 And Single Phase Preventer Including Taking Down Old Unserviceable Starter Complete All As Specified And Directed. 72 S&F Dol Startr 3 Phase, 415 Volt Suitable For 5 Hp Electric Motor Including Taking Down Unserviceable Starter Complete All As Specified And Directed. 73 S&F Dol Startr 3 Phase, 415 Volt Suitable For 7.5 Hp Electric Motor Including Taking Down Unserviceable Starter Complete All As Specified And Directed. 74 Dismantling Existing Centrifugal Pump Set, 5 / 15 Hp Electric Driven 3 Phase 415 Volts From Foundation After Disconnecting Electric Connection And Transporting The Same Workshop For Repair And Refixing The Same After Repair And Making Electric Connection Including Testing Complete All As Specified And Directed By Engineer-In-Charge. Nnote: Replacement Items Shall Be Measured And Paid For Separately 75 Taking Out Burn Out Winding And Rewinding The Centrifugal Pump Set Motor 12.5 Hp 3 Phase 415 Volts With Super Enameled Copper Wire Of Appropriate Gauge Including E Class Insulation Material, Varnishing And Balancing Rotor Connection And Testing To Entire Satisfaction Of Engineer-In-Charge. 76 Taking Out Burn Out Winding And Rewinding The Centrifugal Pump Set Motor 5 Hp 3 Phase 415 Volts With Super Enameled Copper Wire Of Appropriate Gauge Including E Class Insulation Material, Varnishing And Balancing Rotor Connection And Testing To Entire Satisfaction Of Engineer-In-Charge. 77 Supply Only For Replacement Bearing Suitable For 5 Hp Motor 78 Supply Only For Replacement Bearing Suitable For 15 Hp Motor 79 Supply Only Pump Impeller Made Of Bronze Suitable Size For 5 Hp Centrifugal Pump Set. 80 Supply Only Pump Impeller Made Of Bronze Suitable Size For 15 Hp Centrifugal Pump Set. 81 Taking Down Old Un-Serviceable Panel Of Any Type And Size, Supply, Install, Testing & Commissioning Of Cpri Approved Powder Coated Lt Panel Board, Outdoor Type, Floor Mounted, Factory Made Suitable For 415 Volt, 3Ph, 4 Wire, 50 Hz, Ac Supply System Having Busbars Chamber With Copper Bus Bars 400 Amps Rating Mounted On Porcelain Insulators. The Panels Shall Be Factory Made, Double Door, Made Out Of 3.15 Mm Thick Ms Sheet ( Crca ) Totally Enclosed Dust, Vermin & Rust Proof Operated With Front & Rear Opening With Locking Arrangement Fixed With Ms Angle Iron Frame Of Size 40X40x6 Mm Including Internal Wiring With Multistranded Copper Condutor Cable Of Suitable Size Including Lugs And Cable Gland To Incoming And Outgoing Cable Etc Complete All As Directed And Comprising Of The Following :- ( A ) In Comming ( I ) Mccb Four Pole 415 Volts Ac Supply 125 A Thermal Magnetic Release Type 35 / 36 Ka-01 No ( Ii ) Panel Mounted Degital Multi Function Meter For Measuring Voltage ( 0-500 ) Volts Current ( 0-100 Amps ) And Frequency -01 No ( Iii ) Ryb Neon Indicating Lamp ( Set Of Three -01 No. ( B ) Out Going : ( I ) Mccb Four Pole 415 Volt 25 Ka 100 Amp Rating Thermal Magnetic Relase Type-02 Nos. ( Ii ) Fully Automatic Star Delta Starter Suitable For 35 Hp Motor. ( Iii ) Mcb Spn 240 Volt 10 Ka 20 Amp Rating C Curbe 02 Nos ( Iv ) Single Phase Prevantor-01 Nos. ( V ) Ammeter, 0-100 Amp 01 No And Volt Meter 0-500 Valts 01 No. 82 M&L 2Mx1m X19mm Synthetic Insulating Mat Including Taking Out Old Unserviceable Mat Complete All As Specified. 83 M&L Ms Sheet Cover Made Out Of 3Mm Thick Sheet And Angle Iron Frame 40X40x6mm Duly Welded As Per Site Requirement With Locking Arrangement And Handle And Apply Two Coat Of Synthetic Enamal Paint Over A Coat Of Red-Oxide Zinic Chrome Primer Including Taking Down Old Rusted Cover Complete All As Specified And Directed. 84 Brick Masonry Valve Pit Of Size 0.90 X 0.90 X 0.90 M ( Internal Dimensions Of Chamber ) Built In Cement Mortar 1:6, Plain Cement Concrete, M-10 ( Nominal Mix ) Type C-2 ( Using 40 Mm Graded Crushed Stone Aggregates ) As In Foundation Filling And Mass Concreting And Including 15Mm Thick Plastering Internally With Cement Mortar 1:6 And Flush Pointing Externally As The Work Proceeds In Same Mortar And Plain Cement Concrete, M-15 ( Nominal Mix ) , Type B-1, ( Using 20Mm Graded Crushed Stone Aggregates ) As In Coping Complete. 3.15 Mm Thick Ms Sheet Cover, Handle, Locking Arrangement Including Provision Of Angle Iron Frame 40X40x6 Mm For Cover And 2 Foot Steps Made Out Of Ms 16 Mm Dia Round Bars, Wash Out Pipe Made Out Of Gi Pipe Medium Grade, 50 Mm Dia Upto 1 Metre Length, Earth Work In Any Type Of Soil Including Removal To A Distance Not Exceeding 50 Metre And Painting Steel Surface With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer, Complete All As Specified And Directed. 85 S&F Energy Efficient 60W Led Street Light Fixtures With Sufficient Number Of Leds, Control Gear And All Other Associated Accessories And Colour Temperature More Than 6500 ºk And Conforming To The Degree Of Protection Ip - 66 Suitable For Pole Dia Ø 35 / 40 Mm On Existing Poles Complete Including Taking Down Old Unserviceable Street Light Fittings Of Any Capacity All As Specified And Directed . Make: Havells / Cg / Halonix / Bajaj / Polycab 86 S&F Energy Efficient 200W Led Flood Light Fixtures With Sufficient Number Of Leds, Control Gear And All Other Associated Accessories And Colour Temperature More Than 6500 ºk And Conforming To The Degree Of Protection Ip - 66 Complete Including Taking Down Old Unserviceable Flood Light Fittings Of Any Capacity All As Specified And Directed . Make: Havells / Cg / Halonix / Bajaj / Polycab 87 S&F Cast Iron Non Return Sluice Valve Long Body Type, Both Ends Flanged And Drilled, Of Size 80 Mm Bore, ( Isi Marked ) Conforming To Is-14846 -2000 With Pressure Rating Of Pn-1.6 With Steel Spindle And Iron Wheel Head Including Jointing Material Such As Nuts, Bolts, Washers And Rubber Gasket Etc, Including Taking Down Old Unservicealbe Sluice Valve Complete All As Specified And Directed. 88 S&F In Replacement Of Cast Iron Foot Valve Size Of 80 Mm Dia Bore, Confirming To Is-4038, Complete All As Specified And Directed. 89 Supply Only Coupling Bolt Suitable For 30 Hp Induction Motor Complete All As Specified And Directed. 90 Supply Only Coupling Suitable For 30 Hp Induction Motor Complete All As Specified And Directed. 91 S&F Cast Iron Sluice Valve Long Body Type, Both Ends Flanged And Drilled, Of Size 80 Mm Bore, ( Isi Marked ) Conforming To Is-14846 -2000 With Pressure Rating Of Pn-1.6 With Brass Spindle And Iron Wheel Head Including Jointing Material Such As Nuts, Bolts, Washers And Rubber Gasket Etc, Including Taking Down Old Unservicealbe Sluice Valve Complete All As Specified And Directed.