Servicing And Routine Maintenance Of Air Conditioners , Servicing Of Existing Installed Wtac/ Stac/Cgac Of 1 . 5 Tr & 2 . 0 Tr Capacity Ac And Water Coolers Of 80/150/250 Lph , Checking For Unit , Inspection Greasing , Oiling Etc . I/C Chemical Cleaning Of Condensing & Cooling Coil With High Pressure Pump Changing The Air Filter , Checked & Tightening All Electric Connections , Testing The Machine Etc . As Reqd . ( Tentative Service Period From 10 . 03 . 2021 To 30 . 03 . 2021 ) . , Supply & Charging R-22/410/407/32/134A Gas In The Existing Wtac/Stac / Of 1 . 5/2 . 0 Tr Unit I/C Pressure Testing , Flushing The System And Gas Charging Complete As Reqd . , Replacement Of Following Capacity Compressor In The Existing Wtac/Split Ac Making Copper Pipe Connection , Brazing Pressure Testing And Supplying And Charging Refrigerant Gas I/C Cutting The Copper Piping Dismantling Of The Old Compressor Complete As Reqd . ( Make:- Hitachi/ Whirlpool/ Kirloskar As Per Compatibility Of Air Conditioner ) , A ) 1 . 5 Tr , B ) 2 . 0 Tr , Providing & Replacement Wtac/Stac/ Ctac Fan Motor Capacity 1/4 To 1/8 Hp Including Dismantling The Burned Motor From The Existing Unit & Fixing Of New Motor , Making Connections Testing , Commissioning Etc . As Reqd . ( Make:- Lg/ Voltas/ As Per Compatibility Of Air Conditioner ) , Supplying & Fixing 25 Mm Diameter Pvc Heavy Duty Pipe For Drainage In The Existing Split Type Ac Unit With Supporting Clamps Etc . Complete As Reqd . ( Make :- Polycab/ Finolex/ Akg ) , Supplying , Fixing , Testing And Commissioning Of Interconnecting Copper Refrigerant Pipe Of Size Of 1/4 Discharge Side & 1/2 Suction Side From Indoor Unit To Outdoor Unit Alongwith Closed Cell Nitrite Rubber Insulation As Per Specification Properly Supported With Clamps Etc . Complete As Reqd . ( Make :- Mandev / Malaysia ) , Providing And Fixing Of ( 3X2 . 5 Sq . Mm ) Pvc Insulated & Pvc Sheathed Copper Conductor Circular Flexible Cable And Commissioning Etc . As Required . ( Make:-Finolex/Rr Kable/ Skytone/ Havells/ Polycab/Ralison / Bencab ) , Relocating Of Existing Installed Stac Of 1 . 5 Tr & 2 . 0 Tr Capacity With Outdoor Unit , From Its Location To Another Location , I/C Testing & Commissioning Etc . As Required . , Supplying And Replacement Of Following Defective Spare Parts In The Existing Ac Unit I/C Connection Testing Etc . Complete As Required . ( Dismantle Material Retained By Contractor ) ( Make:- Shiva/ Tibkon/ Shrada/ Havells ) , A ) Running Capacitor - 36 Mfd/45 Mfd , B ) Starting Capacitor- 80/100 Mfd , Repair Of Damaged Pcb Of Indoor & Outdoor Unit Including Tightening The Loose Connection , Testing The Machine Etc . As Reqd . , Supplying & Replacement Of Remote Control System With Remote ( Wireless/With Wire Remote ) In The Existing Installed Window/Split Type Ac I/C All Interconnection , Testing And Commissioning Complete As Reqd . ( L . G/ Azure/ Voltas Or Different Suitable Make ) , Supplying And Replacement Of Wornout/Defective Copper Condenser Coil With Same Size Of Design Suitable For Following Capacity Split Type Ac Out Door Unit I/C Breezing The All Copper Pipe With All Distribution Joints Of Make Sure The Connection With Capillary Tube Linking Dryer Duly Proper Etc Pressure Testing Leak Detection , Vaccumizing The Unit , Gas Charging Etc Complete As Reqd . ( Dismantle Retaine By Contractor ) , A ) 1 . 5Tr Capacity , Providing , Fixing Suction / Discharge Valve Of 5/8 Inch And 1/4 Inch Of Split Air Conditioner Unit Including Brazing The Valve With Compressor Suction And Discharge Line Etc . As Required . , Supplying & Replacement Of Following Capacity Split Type Ac Indoor Unit I/C Testing , Commissioning Etc . As Required . , A ) 1 . 5 Tr , B ) 2 . 0 Tr , Supplying And Replacement Of Following Capacity Split Type Ac Outdoor Unit . , A ) 1 . 5 Tr , B ) 2 . 0 Tr , Comprehensive & Routine Maintenance Of Wtac/Stac/ Unit & Water Cooler I/C Attending Day To Day Complaints From 9Am To 5Pm & Rectifying The Defects , Supplying & Replacement Of Worn Out Parts Such As Capacitors , Starting Relays , Selector Switches , Sleeves , Knobs , Front Grills Connectors Etc . Which Required To Be Replace During Routine Maintenance & Monthly Cleaning Of Filters Etc . ( Replacement Of Compressor , Condenser Fan , Blower , Fan/Blower Motor , Coils , Main Lead , Gas Charging Etc . Not Covered Under Routine Maintenance ) Complete As Per Terms & Condition And Direction Of Engineer-In-Charge . ( 102 Nos . X 7 Months=714Nos . ) ( Note:-The Comprehensive Maintenance Will Start After 01Month Of Servicing Of Acs ) , Credit For Dismantle Material . , A ) Worn Out 1 . 5/2 . 0 Tr Capacity Compressor , B ) Burn Out Fan Motor 1 , 1/2 , 1/4 , 1/8 , , C ) Refrigerant Copper Pipe , D ) Worn Out Condenser Coil , E ) Running/Starting Capacitors , F ) Split Type Ac Indoor Unit 1 . 5/2 . 0Tr , G ) Split Type Ac Outdoor Unit 10 . 5/2 . 0Tr , H ) Suction /Discharge Valve