Supply And Installation Of Laboratory Equipments For Centre For Vocational Studies - 1 Uv Spectro-Photometer Make: Thermo-Fisher, Agilent, Biorad, Jenway, Eppendorf ) Nwavelength Range : 190-1100Nm Nspectral Bandwidth : 2Nm ( 5Nm, 1Nm Optional ) Nwavelength Accuracy : ±0.5Nm Nwavelength Reproducibility : 0.2Nm Nphotometric Accuracy : ±0.5%T ( 0-100%T ) , ±0.002A ( 0-0.5A ) , ±0.004A ( 0.5A-1A ) Nphotometric Reproducibility : 0.2%T Nnoise : ±0.001A ( At 500Nm, After Warming Up ) Ndisplay : Lcd Display Ndetector : Silicon Photo-Diode Ndimensions : 530×410×210Mm Nfeatures N• Scan Type Spectrophotometer With Wide Wavelength Range From 190-1100Nm. N• Options For Spectral Bandwidth Selection: 5Nm, 2Nm, 1Nm, Made According To Application Need N• Manual 4-Cell Holder Accommodates Long Path Length Cells Up To 100Mm. N• Optimized Optics And Electronics Design, Light Source And Detectors ( Silicon Photo-Diode ) To Ensure High Performance And Reliability. N• Rich Measurement Methods: Wavelength Scan, Time Scan, Multi-Wavelength Determination, Multi-Order Derivative Determination, Double / Triple -Wavelength Method Etc. N• Data Output Can Be Obtained Via A Printer Port And A Rs- 232 Interface ( Rs485 And Usb Port Optional ) And Laptop Should Be Provide For Data Storage. N• Electric Power Should Be 220V Ac, 50 / 60 Hz N• The Compliance Statement Of Specifications Offered By The Quoted Model Must Be Submitted With The Deviations Clearly Marked And Mentioned Towards Its Non-Compliance. N 2 Pipettes ( 10-100Ul, And 100- 1000 Μl ) Make: ( Gilson, Eppendorf, Himedia, Tarsons ) Nvolume Adjustable Nvolumes, 10Μl-100Μl, 100Μl-1000Μl Nit Should Be Highly Resistant To Heat, Acids And Alkalis, Mildew, Bleaches, Aging, Sunlight And Abrasion Npositioned For Perfect Ergonomics Nejector: Very Low Ejection Force And Positioned For Perfect Ergonomics. Nquick Connection Clip: Remove Lower Part Easily. Nshould Be Supplied With Factory Calibration Certificate. Neuropean Cu Certified Nwarrant =1 Year And From The Date Of Installation And Amc Per Year After The Expiry Of Standard Warranty N 3 Table Top High Speed Non -Refrigerated Centrifuge N ( Eppendorf, Thermo Fisher, Sorvall ) Nmaximum Speed Of 30, 130Xg / 14000 Rpm, With A Brushless Motor Nspeed Setting Should Be Possible In Both Rpm And Rcf Nrotors To Be Supplied With Centrifuge Should Have Minimum N30x1.5Ml Nit Should Be Possible To Store 50 Programs With 5 Quick Access Program Keys Nshould Possess A Separate Short Spin Key For Brief Spin Nrotor Lids Should Have A Quick Lock-System For Secure Lid Closing And Opening Noise Levels Should Be ?54 Db ( A ) Nit Should Be Possible To Operate The Centrifuge At Set Rpm, For Short Spin Protocols Ninstrument Should Be Ce Certified, Ivd Conformity N N 4 Protein Electrophoresis System ( Tarsons, Biorad, Sigma, Himedia And Thermo Fisher ) Ngel Tank Should Be Compatible With Both Homemade As Well As Readymade Gels Ngel Tank Should Be Compatible With Running As Well As Transfer Module Ngel Tank Should Accommodate Up To Four Or More Gels Per Run. Nshould Supply Power Supply Adapters To Connect The Covered Power Leads Of Electrophoresis Units To Power Supplies Made By Other Companies Nshould Supply Gel Handcast System. Nthere Should Be At Least 2-Handcast Stations Nhandcast System Should Include: 2-4 Sealing Pads, 2-4 Glass Plate Sets, Gel Combs ( At Least 2 Each: 10 And 15 Well ) Nthe Blotting Module Should Be A Wet Transfer Device N 5 Multi-Functional Iv Training Arm Injection Nshould Have 8 Vena Of The Vascular System Of The Arm Nshould Provide A Good Training Of Injection, Infusion And Phlebotomization Nskin Color Npvc Material Nrating Should Be Above 4 Star Neuropean Ce Certification Nwarrant =1 Year And From The Date Of Installation And Amc Per Year After The Expiry Of Standard Warranty N 6 Agarose Gel Electrophoresis Unit Tarsons, Biorad, Sigma, Himedia And Thermo Fisher ) Ngel Tank Should Have A Volume Of 400-500 Ml And Compatible Homemade Gels Ngel Tank Should Accommodate Up To Two Or More Gels Per Run. Nshould Supply Power Supply Adapters To Connect The Covered Power Leads Of Electrophoresis Units To Power Supplies Made By Other Companies Nshould Supply Gel Handcast System. Nthere Should Be At Least 2-Handcast Stations Npower Supply Should Have Constant Voltage Or Current Settings Npower Supply Should Have Built-In Timer For Walk-Away Gel Electrophoresis Npower Supply Should Have 2-4 Sets Of Output Jacks That Are Compatible With Most Electrophoresis Devices. Ntwo Boats ( Dams ) Large And Small Nhandcast System Should Include: Gel Combs At Least 2 Each: 5, 10 And 15 Well. Nsuitable For Electric Supply Of 220-240V Neuropean Ce Certification Nwarrant =1 Year And From The Date Of Installation And Amc Per Year After The Expiry Of Standard Warranty N 7 Fridge N ( Samsung, Lg And Whirlpool ) Ncapacity Should Be 300- 340 Liters Ntemperature Range Of 1 ° C To 10 ° C N4-7 Shelves, Adjustable Nfree-Standing Or Horizontal Nsolid State Digital Temperature Controller With Alarm Nstandard Single Or Double Door Nstabilizer Required: No Nsuitable For Electric Supply Of About 220-240V ( Low Energy Consumption ) N 8 Elisa Reader N ( Make: Thermo Fisher, Biorad, Agilent ) N800ts: 6- To 96-Well Plates, 400 To 750 Nm Detection, Shaking Ndetection Modes: Absorbance Nread Methods: End Point. Kinetic, Well Area Scanning ( Under Computer Control ) Nmicroplate Types: 6- To 384-Well Plates Ntemperature Control: To 50 °C ( “I” Configuration ) Nshaking: Yes ( Except 800Tsnb ) Nread Speed: 11 Secs / 96 Wells ( Sweep Mode ) Nsoftware: Gen5 Reader Control Software Gen5 Microplate Reader And Imager Software ( Optional ) Nabsorbance Nlight Source: Tungsten Halogen Nwavelength Selection: Filters Nwavelength Range: 400 – 750 Nm 340 – 750 Nm ( “Uv” Confirgurations ) Ndynamic Range: 0 To 4.0 Od ( Normal And Rapid Read Modes ) 0 To 3.0 Od ( Sweep Read Mode ) Nresolution: 0.001 Od ( Standalone Mode ) 0.0001 Od ( Via Gen5 Control ) Nfilter Wheel Capacity: 5 Positions Nfilters Supplied: 405, 450, 490, 630 340, 405, 450, 490, 630 ( “Uv” Configurations ) Nfeatures: N• Versatile For Many Applications, Including Elisa, Protein And Other End Point Assays, Plus Kinetics And Cell-Based Assays Ncolor Touchscreen For Quick Programming And Simple Operation N• Usb Flash Drive For Convenient Data Export, Gen5 Import For Analysis N• High Precision And Accuracy For Reliable Results N• Durable And High Quality Design From Biotek, The #1 Microplate Reader Brand N N 9 Sphygmomanometer Nmake ( Omron, Dr Morepen, Withings Bpm Connect Nmanual Nshould Have Universal Cuff Naccuracy Should Be Within 5 Mmhg Neasy To Use N 10 Sphygmomanometer Nmake ( Omron, Dr Morepen, Withings Bpm Connect Nautomatic And Digital Nfor Adult Npressurization Through Internal Motor Pump Noscillometric Nautomatic Adjustment Of Cuff Pressure And Exhaust Speed Nmeasurement In Mm Hg Nmeasurement Range Of Heart Rate From 40-180 Or More Naccuracy Of Pulse Rate Measurement ± 2% Nlcd Display N