}

Supply Of Expendable Medical Stores, Miltary Hospital Jabalpur-Madhya Pradesh

Statutory Bodies & Commissions/Committees has published Supply Of Expendable Medical Stores. Submission Date for this Tender is 03-03-2021. Medicine Tenders in Miltary Hospital Jabalpur Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27142625
Supply Of Expendable Medical Stores
Open Tender
Indian
Madhya Pradesh
Miltary Hospital Jabalpur
03-03-2021

Tender Details

Supply Of Expendable Medical Stores , Medicines : , Hip Drape , 1 . 116 In . X 88 In . X 131 In . 2 . Arm Board Covers 3 . 8 . 5 In . X 8 . 5 In . Conformable Teardrop Fenestration 4 . Sms Fabric Reinforcement 5 . Tube Holders 6 . Ce Certified , Aami L-4 Compliance & Usfda , Impervious Stockinette , Medium 1 . Made Up Of Poly Film With Cotton Inner Layer 2 . Impervious Stockinette , 9 In . X 44 In . , Sterile 3 . Ce Certified , Aami L-4 & Usfda , Basic Surgical Gown Xl With 1 . Sms Fabric 2 . Raglan Sleeves 3 . Colour Coded Neck Binding 4 . Adjustable Hook & Loop Neckline 5 . Low Linting Fabric 6 . Book Fold 7 . Ce Certified & Usfda , Orthopedic Tear Resistant Gloves Size 8 . 0 ( Ultrathick 0 . 33 Mm; 40% Thicker Than Regular Gloves ) With Textured Surface And Dark Color To Decrease Reflective Glare In Plastic Peel Off Pack Only , Uncemented Total Hip Replacement System Consisting Of ; Primary Uncemented Fully Ha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Delta Ceramic Head . Primary Uncemented Acetabular Shell 46 Mm With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner . ( All Implant Sizes With Compatible Instrumentation And Drill Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified ) , Uncemented Total Hip Replacement System Consisting Of; Primary Uncemented Fully Ha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Biolox Delta Ceramic Head . Primary Uncemented Acetabular Shell With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell 48Mm With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner ( All Implant Sizes With Compatible Instrumentation And Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified ) , Uncemented Total Hip Replacement System Consisting Of; Primary Uncemented Fully Ha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Biolox Delta Ceramic Head . Primary Uncemented Acetabular Shell 50Mm With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner ( All Implant Sizes With Compatible Instrumentation And Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified ) , Uncemented Total Hip Replacement System Consisting Of; Primary Uncemented Fullyha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Biolox Delta Ceramic Head . Primary Uncemented Acetabular Shell 52Mm With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner ( All Implant Sizes With Compatible Instrumentation And Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified ) , Uncemented Total Hip Replacement System Consisting Of; Primary Uncemented Fullyha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Biolox Delta Ceramic Head . Primary Uncemented Acetabular Shell 54Mm With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner . ( All Implant Sizes With Compatible Instrumentation And Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified ) , Uncemented Total Hip Replacement System Consisting Of; Primary Uncemented Fullyha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Biolox Delta Ceramic Head . Primary Uncemented Acetabular Shell 56Mm With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner . ( All Implant Sizes With Compatible Instrumentation And Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified ) , Uncemented Total Hip Replacement System Consisting Of; Primary Uncemented Fully Ha Coated Double Taper Hip Stem- Collarless , Reduced Lateral Shoulder Double Taper Wedge Titanium Stem With Slim Ap Dimension Proximally Coated Available In Standard And Extended Offset With Compatible Biolox Delta Ceramic Head . Primary Uncemented Acetabular Shell 58Mm With Poly Liner Consisting Of: Titanium Coated Primary Acetabular Shell With Highly Crosslinked / Epoly Polyethylene Liner In Taper Lock Design And Two 6 . 5 Mm Cancellous Screws . Should Be Supplied With Dome And Screw Hole Caps / Solid Option . Should Be Compatible With A Ceramic Liner . ( All Implant Sizes With Compatible Instrumentation And Saw System To Be Provided At The Time Of Surgery , Implant Should Have Registry Follow Up Data . Usfda Approved / Eu-Ce Certified )

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail