}

Procurement Of Hospital Equipments And Accessories, HCL-ICC, MOUBHANDAR-Jharkhand

Hindustan Copper Limited has published Procurement Of Hospital Equipments And Accessories. Submission Date for this Tender is 13-03-2021. Industrial Trucks Tenders in HCL-ICC, MOUBHANDAR Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

26911672
Corrigendum : Procurement Of Hospital Equipments And Accessories
Open Tender
Indian
Jharkhand
Hcl-Icc, Moubhandar
13-03-2021

Tender Details

Procurement Of Hospital Equipments And Accessories - 1 Supply And Installation Of Auto Analyzer. Detail Specification Of Semi Auto Analyze Ni. 7 Inches Tft Touch Screen And Pop Up Keypad Nii. 2 Test Mode –Flow Cell Or Cuvette Niii. External Keyboard Or Mouse Support Via Usb Niv. User-Friendly Interface And Multilanguage Operation Software Build In Thermal Printer N 2 Supply And Installation Of Cardiac Monitor Cum Defibrillator With Recorder. Detail Specification Of Cardiac Monitor Nmultipara Meter 12.1 Inches’ Color Tft Patient Monitor Ni. Super Ability In Against Electrosurgical Interference, Ecg Wave Form And Hr Can Be Influence, Especially Suitable For Use In Emergency Or Operating Room. Nii. 12.1 Inches’ Color Tft Lcd Screen, High Brightness, Wide Viewing 8 Wave Form Can Be Display On The Same Screen, Lightness And Volume Are Adjustable Independently. Niii. Stream Line Out Line Design With Sense Of Times And Foldable Handle. Niv. Multilanguage Interface Selection. Nv. User-Friendly Men Machine Dialogues Interface With Pop Up Manual Dialogues Boxes, Rotary Mouse Etc. Nvi. Low Power Consumption Design With Standby Mode Rechargeable High Energy Build In Battery. Nvii. Blood Pressure Measurement Fast And Accurately, With Venipuncture Function Nviii. Advanced Digital Technology Accurately Measures Spo2 In Low Perfusion Saturation Nix. Drug Calculation, St Segment Detection, Pace Maker And Arrhythmia Analysis Nx. Can Store Five Kinds Of User Defined Display Format Nxi. Sound And Light Integrated Alarm, Alam Parameter Can Be Adjusted For Upper Or Lower Nxii. Suitable For Adult, Pediatric And Neonates Nxiii. Applications In Bedside And Delivery Monitoring Widely Used In Patient Room, Emergency Room, Operation Room, Icu, Ccu Etc. Nxiv. Printing Of Data, Wave Form, Trained Tables And Trained Diagram. Nxv. Optional Co2 Detection Function. Nxvi. Ce And Fda Approved N 3 Supply Of Pulse Oxymeter 4 Supply And Installation Of Autoclave Machine, Electrically Operated ( Alluminium ) . Detail Description : Nsize: 12” X 12” Npressure Chamber: Nthe Pressure Chamber Is The Main Component Of A Steam Autoclave Consisting Of An Inner Chamber And An Outer Jacket. Nlid / Door: Nthe Next Important Component Of An Autoclave Is The Lid Or Door Of The Autoclave. The Purpose Of The Lid Is To Seal Off The Outside The Atmosphere And Create A Sterilized Condition On Ht Inside Of The Autoclave. Npressure Gauge: Na Pressure Gauge Is Present On The Lid Of The Autoclave To Indicate The Pressure Created In The Autoclave During Sterilization. The Pressure Gauge Is Essential As It Assures The Safety Of The Autoclave And The Working Condition Of The Operation. Npressure Release Unit : Na Whistle Is Present On The Lid Of The Autoclave Is The Same As That Of The Pressure Cooker. Nsafety Valve : Na Safety Valve Is Present On The Lid Of Autoclave, Which Is Crucial In Cases Where The Autoclave Fails To Perform Its Action Or The Pressure Inside Increases. Nthe Valve Has A Thin Layer Of Rubber That Bursts Itself To Release The Pressure And To Avoid The Danger Of Explosion. Nsteam Generator: Nan Electrical Steam Generator Or Boiler Is Present Underneath The Chamber That Uses An Electric Heating System To Heat The Water And Generate Steam In The Inner And The Outer Chamber. The Lavel Of Water Present In The Inner Chamber Is Vital As If The Water Is Not Sufficient; There Are Chances Of The Burning Of The Heating System. N 5 Supply Of Ecg Machine With Standard Accessories. Detail Specification Of Ecg Machine Ni. Ecg Machine Complete With Accessories ( 3 Channel ) Nii. 3 Channel Ecg Recording With 12 Lead Niii. Large Color Lcd Display Enabling Preview Of Ecg And Preview Of. Niv. Auto Mode Arrhythmia Detection Nv. Color Lcd Display Ensuring Preview Ecg And Patient Information. Nvi. Internal Memory Storage Of Up To 200 Ecg. N 6 Supply Of Crash Cart Trolley 7 Supply And Installation Of Defibrillator Cardio Machine Biphasic With Monitor, Printer, Overall Accessories Including Rechargeable Battery, Minicable, Disposable Electrode, Cardijelly, Defibrilator Paddles ( Adult & Paedriatic ) , Model: Df 2617 Bpl. Detail Specification Of Dc Cardioversion ( Defibrillator ) Ni. 7 Inches’ Color Display With Build In Printer Nii. Charging Time 6 Second On Mens Niii. Offers Variable Energy Label Selection Niv. Battery Capacities – 70 To 100 Shocks On Single Charge Nv. Adult And Pediatric Paddle Support Nvi. Compact And Lite Wet Nvii. 2 Inches’ Printer N 8 Supply And Installation Of Digital X-Ray Machine. Detail Specification Of X Ray Digitalization Ni. Computed Radiography ( Cr ) System With Dry Laser Printer / Imager– 01 No. Nii. 14”X17” Cassette & Ip – 2 Nos. Niii. Throughput: 40 Cassettes / Hr. Or More For The Cassette Size Of 14”X17” Niv. Resolution: 6 Pixels / Mm Or More Nv. Workstation Pc Should Be Branded Like Dell / Hp With Minimum 19” Lcd / Led Monitor, 1Tb Hard Disk And 4Gb Ram. Nvi. Image Processing Algorithms Are Based On Multi Frequency Processing Type Nvii. Software Automatically Masks The Area Outside The Collimation Edges For Better Productivity. Nviii. System Must Be Capable To Connect To Pacs Through Dicom Store Nix. System Must Be Capable To Print To Dry Laser Printers Through Dicom Print Nx. System Has The Capability To Connect To Existing Ris / His System And Communicate Through Hl7 Protocol Nxi. System Must Be Capable Of Burning Patient Images On Cd / Dvd Nxii. Patient List Can Be Created Either Form The Main Workstation Or From A Web Client Remotely Connected Nxiii. System Should Have Optional Feature Of Reports Can Be Created Either From The Main Workstation Or From Any Web Client Remotely Connected Nxiv. Images And Reports Can Be Distributed Across Web Clients Connected To The Main Workstation Nxv. Minimum Number Of Concurrent Web Clients Supported Should Be 4 Nxvi. System Must Be Able To Print Images Through Standard Paper Printers Networked To The Main Workstation Nxvii. System Offers The Capability To Crop Images, Zoom And Print, Free Image Rotation. Nxviii. System Allows To Add Patient Picture To Demographic Screen Nxix. Dry Laser Printer With Minimum 500 Ppi Resolution, 2 Trays Online, Capable To Print All 4 Sizes ( 14”X17”, 10”X12”, 11”X14” And 8”X10” ) Without Any Hassle. Nxx. 3 Kva Online Ups With Minimum 15 Minutes Battery Backup – 01 No For Cr System And Printer. Nxxi. Cr System And Dry Laser Printer Should Be Us Fda Approved Model N 9 Supply And Installation Of Boyels Apparatus Complete Set. Detail Specification Of Boyel’S Apparatus Ncomplete Set. N

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-03-2021 Date Corrigendum of Tender No. 12913-OPEN-HOSP-PSD-Extn-2, dated 03-Mar-2021. Date 13-03-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail