}

Installation Of Current Weather Instrument System At B.M.Airport,, AAI,B.M.Airport, Ranchi-Jharkhand

Airports Authority Of India has published Installation Of Current Weather Instrument System At B.M.Airport,. Submission Date for this Tender is 11-03-2021. Earth Moving Machinery Tenders in AAI,B.M.Airport, Ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

26789242
Corrigendum : Installation Of Current Weather Instrument System At B.M.Airport,
Open Tender
Indian
Jharkhand
Aai,B.M.Airport, Ranchi
11-03-2021

Tender Details

Installation Of Current Weather Instrument System At B.M.Airport, - 2 Sitc Of 3.0 Kva Online Ups Suitable For Outdoor Applications With Input Voltage Range 150-280 V Ac, Single Phase, 50 Hz And Output Voltage Of 230 V Ac, Single Phase, 50 Hz With Back Up Not Less Than 15 Minutes With Harmonic Distortion < 2-3 % For Linear Loads, Having Protection Over Short Circuit, Overload, Battery Deep Discharge & Overcharge Protection Along With 06 Nos. Of Batteries Of Capacity 26Ah, Necessary Inter-Connections, Wiring Etc. Complete As Required. 3 Supplying And Fixing 8 Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, Ip 54 Protection, 240 V, On Surface / Recess, Earth Bar, Din Bar, Interconnections With Wire, Powder Painted Including Earthing Etc. As Required. ( With C Curve Mcbs As Following ) N ( I ) 20 A Dp Mcb - Incomer N ( Ii ) 5 A Sp Mcb - 3 Nos. N ( Iii ) 10 A Sp Mcb - 1 No. N 4 Supplying And Fixing 18 Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 5 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections With Wiring But Excluding Modular Plate Etc. As Required. N ( I ) 5 / 6 A Switch 6 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections With Wiring But Excluding Modular Plate Etc. As Required. N ( Ii ) 3 Pin 5 / 6 A Socket Outlet 7 Design, Manufacturing, Supply, Installation, Testing And Commissioning Of Enclosure Of Size 1000Mm X 1000Mm X 750Mm Made Of Modular Polycarbonate Thermoplastic, Ip 66 Enclosures Suitable For Housing 3.0 Kva Ups Alongwith Batteries, 8 Way Spn Db & Power Point Board Mentioned At Item No. 1, 2 & 3 As Above On Frangible Base Of Minimum 1.2 Metre Height Or As Per Site Requirement As Per Direction Of Engineer-In-Charge. 8 Supply Of Xlpe Insulated & Extruded Pvc Inner Sheath And Pvc Outer Sheath Power Cable Of Aluminum Conductor, Armoured, 1.1Kv Grade Conforming To Is :7098 Part I With Upto Date Amendments In Following Sizes. N ( A ) 3 Core 35 Sq. Mm. 9 Supply Of Pvc Insulated And Pvc Sheathed Multistranded 12 Core And 1.0 Sqmm Copper Cable. 10 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc. As Required. N ( A ) Upto 35 Sq. Mm 11 Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc. As Required. N ( A ) Upto 35 Sq. Mm 12 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Rcc / Hume / Metal / Hdpe Pipe As Required. N ( A ) Upto 35 Sq. Mm 13 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In The Existing Masonry Open Duct As Required. N ( A ) Upto 35 Sq. Mm 14 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. N ( A ) Upto 35 Sq. Mm 15 Supplying And Making End Termination With Double Compression Brass Cable Gland ( Flameproof ) And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. N ( A ) 3 Core 35 Sq.Mm. 16 Supply Of Hdpe Pipe Pn-8, Pe-100 Grade Of Following Size Dia As Per Specification Enclosed In Tender Document Etc. As Required. N ( A ) 110 Mm Dia 17 Making Horizontal Boring By Hdd Method For Crossing Of Taxiway Track, Road Including Laying Of Hdpe Pipe Of 110 Mm Dia At The Depth Of 1.5 Mtrs To 3 Mtrs From The Top Surface, Interconnections Of Hdpe Pipe For Laying Complete As Required. 18 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 19 Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. 20 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 21 Providing And Fixing 4.00 Mm Dia Copper Wire On Surface Or In Recess For Loop Earthing As Required. 22 Constructing Brick Masonary Manhole Chamber Of Min. Inner Dimension 1.0 M X 1.0 M X 1.0 M With Medium Class Bricks In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) R.C.C. Top Slab Of 100 Mm Thick With Mix 1:3:6 Cement Concrete ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Of Aggregate 20Mm Nominal Size ) , Foundation Concrete 1: 3: 6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Of Aggregate 40Mm Nominal Size ) In Side Plastering 15 Mm Thick With Cement Plaster 1:4 ( 1 Cement : 4 Fine Sand ) , 01 Nos Of Rcc Slab / Covers Should Be Provided In A Ms Angle Frame Work Of Size ( 40M X 40 X 3Mm ) At The 04 Nos. Of Edges On Top And Bottom Of The Slab Including Ms Handle For The Slab. The Concrete Manhole Chamber Shall Be Constructed After Excavation For Necessary Foundation Including Dressing Of Sides, Ramming Of Bottoms And Filling Available Excavated Earth ( Excluding Rock ) In The Sides Of Foundations Etc. And Consolidating Each Deposited Layer By Ramming And Watering And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Meters. 23 Sitc Of Advanced Lightning Arrester With Non-Corroding Air Terminal, Cpri Tested Early Streamer Emission Lightning Conductor ( Eselc ) , Having Minimum 62 M Radius Of Protection When Installed At A Mast Of 10M, With Necessary Mounting Arrangements As Required On The Mast As Required. ( Make : Tercel, Tz50 Or Equivalent ) . 24 Sitc Of Lightning Transient Event Counter Resettable ( Multi Digit ) Lcd Display With In Built Lithium Battery In Ip67 Rating Enclosure With Transparent Lid, Mounting Arrangements Etc. As Required ( Make Equivalent : Tercel, Ilco1or Equivalent ) 25 Supply And Laying Of 1X70 Sqmm. Copper Flexible Wires Conforming To Is:694 With Up To Date Ammendment As Down Conductor From Air Terminal To Earth Pit. 26 Providing Earth Pits Material Using Isogel Earth Enhanced Compound Of 20 Kgs, Isorod Advanced Chemical Earth Rod Made With K Type Copper Tube Of 2.5 Dia, 8 Ft. Long, 1.6 Mm Thick Installed Vertically Complete With Flanges Bends Top Cover Heavy Duty Plastic Inspection Chamber Including Excavation And Refilling Etc As Required. 27 Sitc Of 2Mtr. Frp Supporting Structure Of Outer Dia 68Mm And Inner Dia 60 Mm For Installation Of 8 Mtr. Gi Mast ( 2 Inch Dia ) Along With All Other Accessories For Installating Lightening Arrestor, Support Wires, Pcc Foundation Etc. As Per Site Requirement And As Directed By Engineer-In-Charge. 28 Sh-Ii : Cns Items 29 Laying Of Of 12 Core Armored Ofc Cable With Hdpe Through Digging, Trenching Including Supply And Back Filling With Sand & Brick, As Required For 5Ft. Depth ( Cable Marking At Every 200Mts ) 30 Supply And Laying 40 Mm ( Inner ) Dia Pvc Hdpe Pipe 31 Supply Laying , Termination & Testing Of 12 Core Outdoor Single Mode Armoured Ofc Cable 32 Fixing, Termination, Testing And Commissioning Of Fully Loaded Liu For 12 Core Ofc Including Sc Single Mode Pigtail Adopter And 3 No. Of Sc-Lc Connectors Single Mode Patch Cords ( For Each Liu Panel ) , Splicing & Marking. 33 Supply & Installation Of All Weather Proof Outdoor Box Complying To Ip66 / Ip67 Standards. 34 Supply Installation And Testing Of Media Converter Optical To Ethernet ( With 4 Ethernet Port ) 35 Supply Installation And Testing Of 16 Port L2 Fully Managed Poe Switch With 16 Nos Of 1G Copper Port And 2 No.S 1G Sfp Slot Fully Loaded With 2 Nos. Of Compitable Sfp Module ( For Each Switch ) . 36 Supply Installation & Testing Of Complete 9U Rack Wall Mounting With All Accessories ( Rack Power Supply Strip, Cable Manager, Rack Door Etc. ) 37 Splicing & Testing Of 24 Nos. Of Fiber. 38 Supply And Laying Of Network Cable I.E. Of Cat 6A Utp Cable Withing Ats Complex And Providing The Required Number Of Points As Per The Requirement Of Wx Data Display And Dissemination Within The Ats Complex To Different Units Like Acc, Fiic Approach, Communication, Iaf Etc. Including Following : N ( A ) Supply , Installation & Testing Of Cat6a I / O Module = 30 Nos. N ( B ) Supply , Installation & Testing Of Single Face Plate = 30 Nos. N ( C ) Supply , Installation Of Pvc Back Box = 30 Nos. N ( D ) Supply And Crimping Of Rj45 Connector = 100 Nos. N ( E ) Supply , Installation & Testing Of Cat6 24 Port Jack Panel ( Fully Loaded ) = 2 Nos. N ( F ) Supply Of Cat6 Patch Cord 1Mtrs. = 32 Nos. N 39 System Configuration Documentation Testing And Commissioning Of Project ( Sitc Of Project ) 40 Sh-Iii : Civil Items 41 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Meansin Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Gettingout The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. Nall Kinds Of Soil. N 42 Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Nnot Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Up To 50 M And Lift Up To 1.5 M. Nall Kinds Of Soil N 43 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding Nthe Cost Of Centering And Shuttering - All Work Up To Plinth Level : N1:1½:3 ( 1 Cement: 1½ Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nnominal Size ) N 44 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding Nthe Cost Of Centering And Shuttering - All Work Up To Plinth Level : N1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 20 Mm Nnominal Size ) N 45 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : N1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) N 46 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : Nfoundations, Footings, Bases Of Columns, Etc. For Mass Concrete N 47 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : Ncolumns, Pillars, Piers, Abutments, Posts And Struts N 48 Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size / Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding / Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Nextra Sand. Complete All As Per Direction Of Engineer-In-Charge. N80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern. N 49 Providing And Fixing Aluminium Extruded Hollow Profile Section At The Side Of Road For Maintenance Vide Met List Of Works As Per Direction And Satisfaction Of Engineer-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-03-2021 Corrigendum - IV Date 11-03-2021
2 11-02-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-02-2021
3 18-02-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-02-2021
4 25-02-2021 Corrigendum-III Date 04-03-2021

Key Value

Document Fees
INR 1120 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail