Item Description(Click Sheet 'SPEC' to view full specification)
Item Code / Make
Quantity
Units
1
1
Explosion Proof Zirconia Type Oxygen Analyser for CPP Flue gas\nMeasurement:\nAnalyser Type: Insitu Type (Non extractive type)\nService : RLNG Fired Heater Stack Flue Gas Oxygen Measurement.\nMeasurement Sensor: Zirconia Oxide cell (Diffusion type)\nInstrument Range : 0 to 25 % O2\nMin. Instrument Performance: 1.0 % accuracy in reading or <(><<)> 3%\nmeasurement drift per month.\nProcess Temp. : 25 to 400 ? (Min)\nAmbient Temp : 25 to 45 ?\nProbe length : 6.0 Ft (Direct insertion type).\nProbe Materials : Wetted parts :SS 316 or better.\nNon wetted parts :Mounting Flange: SS304 or better.\nMounting : Horizontal - Direct installation to Stack.\nStack Flange Size : 3 ANSI 150# RF.\nTransmitter Details:\nType : Smart Microprocessor based.\nMounting : Integral mounted on probe head.\nEnclosure Material: Aluminium alloy.\nEnclosure type : NEMA 4X, IP65, Exproof to Exd II B or better.\nCable Entry : 1/2 NPT\nPower Supply : 110 V AC 50 Hz.\nOutput signal : 4 to 20 mA DC with HART connectivity.\nCalibration Gas and reference gas connection : 1/4 NPTF or with\nsuitable adaptor for 1/4 connection.\nSelf Diagnostic : Required.\nCalibration : Semi Auto / Auto/Manual.\nReference Gas System: Instrument Air; 4.5kg/cm2 (Maximum).\nElectronic modules,Heater and T/C shall be repleaceable type: Yes\n\n
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.