Rate Contract Comprehensive Maintenance Of Dea Set Shifting Of Dea Sets And Rectification Of Initial Defects Of Dea Sets At Various Sites Under Bsnl Ed Amritsar . ( Phase-I ) Rate Contract Comprehensive Maintenance Of Dea Set Shifting Of Dea Sets And Rectification Of Initial Defects Of Dea Sets At Various Sites , Sub Head-I ( Comprehensive Maintenanace Work ) Providing Maintenance Free New Lead Acid Batteries As A Replacement Of Existing Old Batteries Of Following Types/Rating Complete With First Fill Of Electrolyte & First Charging I/C Replacement Of Leads , Nut Bolts , Terminals/Thimbles Complete As Reqd . , 15 Kva---1No . , 40 Kva--1 Nos , 60 Kva---1No . , 75 Kva--1 Nos , 82 . 5 Kva--1 No . , 100 Kva---2 Nos . , 125 Kva---1 Nos . , 150 Kva---1 Nos . , 220 Kva----1No . , 250 Kva----1 No . , 300 Kva----1 No . , Sub Head-Ii ( Servicing And Shifting Of Dea Set Works ) General Servicing Of Following Capacity Of Dea Sets Of Different Makes And Models Under Various Exchanges Comprising Of Following Jobs I/C Transportation , Labour Charges & Material Required For Servicing I/C Minor Material Required For Healthyness Of Dg Set Etc . As Reqd . ( I ) Cleaning & Greasing Of The Parts . ( Ii ) Tappet Setting As Per Standard ( Iii ) Fan Belt , Tensioner Pulley And Lever Adjustments . ( Iv ) Tightening Of All The Nuts , Bolts And Clamps . ( V ) Testing & Checking Of Ac & Dc Wiring . ( Vi ) Self & Charging Alternator Cleaning And Testing , Checking Of Working & Minor Fault Removal . ( Vii ) Checking Of Supply & Return Fuel Pipes From Fuel Tank To Engine . ( Viii ) Replacement Of Consumables Like Lub Oil , Diesel Filter , Oil Filter , Filter Element Of Air Cleaner & Coolant ( In Case Of Water Cooled Engines ) . ( Ix ) Checking Of Fip Timing By Fuel Cut Off Method . ( X ) General Servicing I/C Cleaning Of Dg Panel ( Xi ) General Servicing & Complete Cleaning Of Dg Set , 15 Kva , 20 Kva , 30 Kva , 40 Kva , 50 Kva , Shifting Of Dea Sets From Following Stand Alone Sites To Bts Hub Sites Including Dismantling The Dg Set From The Existing Foundation , Earthing , Electrical Cable , Loading The Dg Set Along With All The Associated Items With The Help Of Crane/Labour , Transporting The Dg Set Along With All The Accessories To The Desired Site Including Arranaging The Suitable Vehicle For Transportation And Unloading The Dg Set Along With All The Accessories With The Help Of Crane/Labour , Installation Of Dg Set On The Existing Foundation , Termination Of Earthing , Electrical Cable , Testing And Commissioning Etc . As Per Requirement At Site As Per Following . , Upto 50 Kva With Canopy ( Within 50 Km ) , Upto 50 Kva With Canopy ( Between 50 Km To 100 Km ) , Shifting Of Dea Sets From Following Stand Alone Sites To Bts Hub Sites Including Dismantling The Dg Set From The Existing Foundation , Earthing , Electrical Cable , Loading The Dg Set Along With All The Associated Items With The Help Of Crane/Labour , Transporting The Dg Set Along With All The Accessories To The Desired Site Including Arranaging The Suitable Vehicle For Transportation And Unloading The Dg Set Along With All The Accessories With The Help Of Crane/Labour Etc . As Per Requirement At Site As Per Following . , Upto 50 Kva Without Canopy ( Within 50 Km ) , Upto 50 Kva Without Canopy ( Between 50 Km To 100 Km ) , Above 50 Kva And Upto 100 Kva Without Canopy ( Within 50 Km ) , Above 50 Kva And Upto 100 Kva Without Canopy ( Between 50 Km To 100 Km ) , Above 100 Kva And Upto 250 Kva Without Canopy ( Within 50 Km ) , Above 100 Kva And Upto 250 Kva Without Canopy ( Between 50 Km To 100 Km ) , Installation Of Dg Set On The Existing Foundation , Fuel Tank Alongwith Fuel Pipe , Exhaust Pipe & Silencer Including Making Opening In The Wall For Passing The Exhaust Pipe And Making Good The Damages , Termination Of Nuetrla & Body Earthing , Electrical Cable , Testing And Commissioning Etc . As Per Requirement At Site As Per Following . , Upto 50 Kva Without Canopy , Above 50 Kva And Upto 100 Kva Without Canopy , Above 100 Kva And Upto 250 Kva Without Canopy , Sub Head-Iii ( Repairing Works Of Dea Sets ) Providing Maintenance Free New Lead Acid Batteries As A Replacement Of Existing Old Batteries Of Following Types/Rating Complete With First Fill Of Electrolyte & First Charging I/C Replacement Of Leads , Nut Bolts , Terminals/Thimbles Complete As Reqd . , 12 V , 150 Ah ( M/S Exide Express Model No . Fxpo-Xp1500 Or Equivalent Model Of Similar Superior Make ) , 12V , 130 Ah ( M/S Exide Express Model No . Fxpo-Xp1300 Or Equivalent Model Of Similar Superior Make ) , Supply Installation Testing Commissioning Of Super Capacitor Based Dg Cranking System Consisting Of Suitable Nos . Of Supercapacitors And Battery Cahrger . The Dg Cranking Device Shall Be Suitable For Starting Of Dg Sets Upto 25 Kva Capacity As Per Specification Attached . ( M/S Delta/ Intelux/Vnt Or Similar Superior Make ) , Replacement Of Following Defective Accessories In The Existing Dg Sets With New Accessories , Complete As Reqd . [Dismantled Defective Accessories Shall Belong To Vendor , Credit For Same Has To Be Considered While Quoting Rates . ] , Stop Solinoid 12 Volt ( Engine Shut Off Solenoid ) , Mechanical Type Rpm Cum Hour Meter , Rpm Cum Hour Meter Chain , 12 Volt Electrical Battery Charger ( Smps ) I/C Transformer , Rectifier Unit And Filter Circuit Etc . Complete As Reqd . , Oil Pressure Gauge , Oil Temperature Meter With Safety , Water Temperature Meter , Starting Key Switch , 100 Amps Mccb 25 Ka , Vaf Meter , 32 Amp 4 Pole Mcb , 63 Amp 4 Pole Mccb , Dc Voltmeter , Dc Ammeter , Auto / Manual Rotary Switch , Overspeed Safety , Sitc Of Automation Relay In Amf Panel For Following Rating Of Dg Set Compatible With All Makes Of Ea Sets Complete As Required ( Econ-Abt Model Of M/S Procom Or Equivalent Model Of Similar Superior Make ) , 15 Kva-50 Kva , Repairing & General Servicing Of The Existing Faulty Radiator In Existing Dea Set By Repairing Of Leakage And Cleaning Of Copper Tubes With Help Of Cleaning Agents , Dismantling Of Radiator Assembly Including Transportation , Brazing And Testing For Leakage And Re-Installation After Repairing The Same Etc . Reqd . , Upto 20Kva Dea Set . , Above 20Kva And Upto 50Kva Dea Sets , Above 50Kva And Upto 250Kva Dea Sets , Above 250Kva And Upto 500Kva Dea Sets , Servicing Of The Self Starter Of Dea Set I/C Dismantling , Cleaning Of Self With Petrol , Greasing And Oiling Of Bearing I/C Testing Etc Complete As Reqd . ( This Item Exclude The Cost Of Parts Associated With Self Starter . ) , Repairing Of Following Faulty Items In The Self Starter Of Dea Set I/C Dismantling Of Unserviceable/ Defective Items , Fixing With New One I/C Connection , Testing Etc Complete As Reqd . [Note: Labour Charges Already Covere