Providing Medical Equipments To Maternity Hospital In Yeshwanthapura At Ward No.37 1. Adult Resuscitation Kit And Pediatric Technical Specifications Emergency Resuscitation Kit Adult And Pediatric 1.Adult Ambu Bag: 500Ml And 1500 To 2000Ml Capacity, Latex Free Silicon Make, Autoclavable, Self Inflating Bag With Non Breathing Valve With 22 Mm Od / 15 Mm Id Patient Connection. Oxygen Reservoir Bag With Valve And 1 Meter Oxygen Tubing. Silicon Make Adult Face Mask (Autoclavable). Anatomical Face Mask. No 0 To 5 Sizes: Silicon Make Face Mask No 0 To 5 Sizes (Autoclavable). Oropharyngeal Airways. 0 To 5 Sizes 0 To 5 Sizes 1 Each Disposable. Laryngoscope Macintosh Type Green Line Standard Handle With Set Of 3 Compatible Blades (1 Each Of Infant, Child And Adult Size) With One Extra Large Blade. 5.Laryngoscope Straight Blade (Paediatric). Pvc Endo Tracheal Tu.S 3 Set Each, Size 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6,6.5, 7, 7.5, 8.0 And 8.5 Each Disposable Variety 2 Dozen Each. Naso Pharyngeal Airways Large And Small Made Up Of Silicon (Autoclavable). Laryngeal Mask Airway Size 3And 4, Disposable (1 Dozen Each). Manual Suction: Foot Operated With .Llows. Supraglottic Airway Device: With Preformed / Inflated Cuff And Port For Suction/ Nasogastric Tu. Insertion Standard Adult Sizes One Of Each Size. Emergency Chest Draine Kit Disposable Set (3 Set) .Mini Tracheostomy / Cricothyrotomy Kit: Disposable Kit (Withknofe, Wire And Dilator). Magills Forceps Adult Size Metallic Autoclavable Stainless Steel. Bains Circuit And Jr Circuit Pvc Disposable Of Standard Size With Rebreathing Wire. Shall . Padlocking Facility, Handle Grip. Styllete (Set Of 3 Pcs) (Paediatric And Adult) Boojiepaediatric And Adult 3 Set Each.Mucus Extractor 2 Pcs.Face Mask Round Shape 1 Set (Size 00, 0, 1,).Oxygen Hood Round Jointless 1Set, 2. 5).Anesthesia Work Station Anesthesia Work Station With Ventilator Specification For Anesthesia Workstation With 1 Vaporizeradvanced Three Gas Anesthesia Workstation With An Integrated Ventilator For Adult To Infants And Integrated Airway Monitor For Airway Pressure, Volume, Fio2. The Machine . . Suitable For Low And Minimal Flow Anesthesia Application With Compliance Compensation Of Breathing Circuit, Fresh Gas Decoupling, And Breathing System Heater System . . Fda Approved And Confirm To En 60601-2-13 (Requirement For Safety And Essential Performance Of Anaesthesia System)Gas Delivery System . . Pin Index Yokes For Oxygen And Nitrous Oxide .Sides Separate Non Interchangeable Connection For Central Gas Supply For Oxygen, Nitrous Oxide And Air. The Machine . . Pressure Gauges For Cylinders And Central Supply Lines Mounted On Front Of Anaesthesia Machine For .Tter Visibility. Automatic Cutoff Of N2o By Oxygen Pressure Failure.Hypoxic Guard For Linear Regulation Of Minimum Oxygen Concentration At 21% Volume And Must Ensure A Minimum Oxygen Flow Of 200 Ml At Low Fresh Gas Flow Settings Even .Low Total 500 Ml Fresh Gas Flowaudio/Visual Oxygen Failure Alarm For Seven Seconds Emergency Oxygen Flush At 30 To 70 L/Min Bypassing The Vaporizer.Electronic Measurement Of Each Gas Of Fresh Gas Flow And Visualized By A Digital System Mechanical Backup Flow Tu. For Total Fresh Gas Vaporizer Machine . . Possibility To Mount Two Quick Mount Type Vaporizer For Easy Interchangeability. Interlocking To Allow Use Of Only One Vaporizer At A Time. Provided With A Temperature / Pressure Compensated And Flow Independent Vaporizer For Isoflourane And Sevoflurance .Vaporizer . . Extended Delivery Range From 0 To 6 Vol. % The Vaporizer Design . . Maintenance Free. Breathing System Fresh Gas Decoupled Semi Closed Circle Absor.R System. Adjustable Pressure Relief Valve From 5 To 75 Mbar. Change Over From Spontaneous To Bag Ventilation With Single Switch. Optimized Absor.R Canister Approx 1.5 Ltr. . . An External Fresh Gas Outlet For Connecting Magill Or Bains Circuit, 3. Specification For A Scan Lcd Monitor 220V 50 Hzusb Port For Pc Printerspro.Frequency 11 Mhzdiameter Of Tip 6 Mm Methodcontact, Immersiofocus .Amledlectronic Resolution0.04 Mmdepth 45 Mm Axial Length Measurementstypes Of Measurementanterior Cham.R, Lens, Vitreous, Total Length, Automatic Calculation Of The Standard Deviation And Averageresultsauto, Auto Plus Save, Manual (Foot Pedal)Automatic Detection Of Sclera Spikeformulas Includedformulas For Implant Calculation: Srk T, Srk Ii, Holladaybinkhorst Ii,Hoffer Q, Haigisscreen Display Of 2 Different Implant Alculationsimplant Values Available In Increments Of: 0.25D Cr 0.50Dspecifications, 4. Aspheric Lenses 90 D Lensfield Of View 4 Deg/89 Deg Image Mag 0.76Xlaser Spot 1.32 Xworking Dist. 7Mm, 5. Auto Refractometer With Keratometer Measurable Range Spher25.00 D To Plus 22.00 D (Vd =12Mm)(0.12D / 0.25Dincrements)Cylinder 0D To Plus Or Minus12d(0.01/0.12/0.25D Increments)Axis 0 Deg To 180Deg (1Deg/5Deg Increments)Measurable Minimum Pupil Diameter 2Mmauto Keratometermeasurable Rangeradius Curvature5.00 To 10.00 Mm( 0.01 Mm Increments)Refractive Power33.75D To 67.50 D(N= 1.3375)(0.12D/ 0.25D Increments)Stigmatism0d To Plus Or Minus 10.00 D/ 0.12D/ 0.25D Increments)Axis 0Deg To 180Deg /5 Deg Increments)Pd Measurable Range20 To 85 Mm ( 1Mm Increments)Auto Tracking And Auto Shooting X Y Z Directions, Auto Shooting Chart Scenery Chart Or Equivalentdisplay Colour Lcdprinterbu In Thermal Type Line Printer(Easy Loading And Auto Cutter)Power Supplyac 100 To 240 V Plus Or Minus 10%, 50/ 60 Hz, 6. ). Autoclave (Horizontal 9Kv) Horizontal Model For Easy Loading And Unloading Of Materials Strictly Fabricated To Astm Standard Section 8 As Per Pressure Vessel Norms. All Welding Are Done By The Process Of Tig And Tested By In House Radiography And Die Penetrate Test. Inner Cham.R : Ss 304/316 Steam Jacket : Ss 304Working Pressure : 1.2Kg/Cm2 And 2.1Kg/Cm2working Temperature : 1210C / 1340Cdoor : Sliding Door / Double Doordoor Operation : Manual Radial / Sliding / Hinged Doormode Of Control : Multiport Valve / Automaticgasket : Silicon Expansion Typeoptional :High Vacuum With Vacuum Pumpfully Automatic Ss Trolley And Ss Voltage440 Vpower Kw 12Door Lock, 7. Autoclave Indicator Tapes (As Per Standard Specification), 8. Autoclave Machine Big Verticalvertical Autoclave (Isi) Markingdouble Walled Construction Working In The Principle Of Upward Displacement Of Air( Gravity ),Suitable For Only Wet Sterilization Like Preparing Media And Other Microbiology Activities.The Cham.R And Outer Insulation Cover Made Of Quality Ss Material. The Door Can . Hinged Or Pedal Lifting Type And Locking With Wingnut Or Radial Type. The Maximum Working Temp 121Deg To 134 Deg The Maximum Working Pressure 1Kg(15 Psi) - 2.2 Kg(32 Psi)Optional : Digital Temperature With Timer And Solenoid Valve The Maximum Working Temp 1210C To 1340Cthe Maximum Working Pressure 1Kg(15 Psi) - 2.2 Kg(32 Psi)Optional : Digital Temperature With Timer And Solenoid Valveham.R (Mm)450 X 650 Volume Ltr 95 Voltage Power4 Kw, 9. ).Autoclave Machine Small Verticalsemi-Automatic Electric Autoclave Tabletop Modelcham.R Apacity 20 > Litrescham.R Made Of Type 304 Stainless Steelwith Manual Door Closing System Double Locking Safety System And Pressure Activated Lock With Automatic Shut Off In Case Of Overheating Including The Following Safety Systems: Thermostat, Pressure Switch, Valves Set Of Filters For Air Intake System Temperature For Autoclaving: 121Degc And 134Degc Complete With Set Of Approx. 4 Type 304 Stainless Steel Instrument Trays Dimensions Are Approx. (L X W X H) 600 X 450 X 500 Mm, 10. Baby Incubator Incubator Single Wall Canopy Swivelling Doors With 2 Portholes On Front Panel And 2 Portholes On Rear Panel Baby Tray With Facility Head Up/Down Air Mode Control Range: < 28 Degc To > 38 Degc, With Resolution .Low 0,1Degc Skin Mode Control Range: < 34 Degc To > 38 Degc, With Resolution .Low ,1Degccontroller With Lcd And Brightness Control Reusable Skin Pro., Skin Temperature, Relative Humidity, And Oxygen Concentration And Heater Poweralarms For Controller Failure, Sensor Module Out Of Position, High/Low Skin Temperature, Motor Failure, Sensor Disconnected, Heater Failure And Key Stuckvariable Heightmanual And Servo-Temperature Controlwith Servo-Humidity, Range Of >45 - < 90 %Two Swivel Drawers And One Single Drawer On The Other Sidewith Iv Pole Mounting Optionmattress Made Of Flame Retardant, Washable Antibacterial Material, Resistant To Corrosion, Water, Detergents And Alcoholincluding .D/ Mattress (L X W) >550 X 340 Mattress, 11. Beside Locker Size: H32 Inch X W16inch X D16inch Size Of The Cupboard: H16inch X W14inchx D16inch Located In The Centre Cupboard Made Of Crca Steel Sheet With Double Hinged Door And Locker Facility Locker Top To . S.S. Sheet Super Imposed With Raised Edges On Three Sidesframework Of 1Inch Square M.S. And Legs With Rub.R Feet. Full Frame And Cupboard To . Powder Coated In Seamens Grey Colour With 50 Microns Coating.. . Isi / Ce Certified, 12. Bio Safety Cabinet (As Per Standard Specification), 13. Boyles Apparatus Product Specificationusage/Application Medical Usepositioning Trolley, Portableautomation Grade Emiautomaticpower Electricproduct Descriptiondetails:Two Gases Rotameter Oxygen And Nitrous-Oxidestandard Fresh Gas Outlet.Change Over System Open Circuit To Close A Circuit.Emergency Flush Valve.Goldman Type Halothane Vaporizer.Non Return Cum Pressure Relief Valveblows Off Valve When The Pressure Exceeds 200Cm Of Water Column Fittedprovision To Fit Ventilator.Provision To Fit Carbon Dioxide Absor.R.An Extended Platform At Rear For Two B Type Cylinders.One Spacious Drawer On A Smooth Runner.Four Castor Trolley With Front Two Lockable Wheels.High Efficiency Regulators For Reliability Two Each For O2 And N2o.Safety Features:N2o Cut Off In Case Failure Of Oxygen Supply.Low-Pressure Oxygen Audible Alarm.Optional:Circle Absor.R.Anesthesia Ventilator.Vaporizer.Mox Regulator.Monitor.Cylinder, 14. Bp Apparatus (As Per Standard Specification), 15. Bp Apparatus (Mercury Free) (As Per Standard Specification), 16. Cautery Machine. Technical Specificationhf Cautery Machine Designed At 500Khz(460 Khz) Frequency Microcontroller Based Isolated Electrosurgical Generator Having Both Monopolar And Bipolar Outputs Designed For All Surgical Procedures.Smart Generator . . Able To Monitor Changes In Tissue Impedance Continuously And Adjusts Power.Monopolar Outputs . . Three Cutting Modes:Low Cut For Delicate Tissue Or Laproscopic Cases Having Maximum Power Of 300W.Pure Cut For Clean, Precise Cut In General Surgery Having Maximum Power Of 200W.Blend Mode For Cutting With Homeostasis Having Maximum Power Of 200W.All Cut Modes . . Able To Adjust Output Power Depending On Tissuedensity By Less Than 15% Or 5W, Whichever Is Greater.It . . Three Coag Modes With Maximum Power Of 120 To 450 Wdesiccate Mode For Low Voltage Contact Coagulation Suitable For Laproscopic And Delicate Tissue Work.It . . Three Bipolar Modes With Maximum Power Of70w It . . Patient Plate Monitoring Facility And . Giveaudiovisual Alarm And Deactivate Output If Contact .Tweenpatient And Patient Plate Is Not Proper To Eliminate The Risk Ofpatient Burns.The Unit . . Two Hand Switching And Two Footswitchmonopolar Outputs And One Hand Switching And Footswitchingbipolar Output.It . . Membrane Keyboard For Power Settings.The Unit . . Individual Digital Display Of Power Forbipolar, Monopolar Cut And Monopolar Coag.The Unit . Not . Rf Leakage Current More Than150ma.Accessories: Monopolar Footswitch: Bipolar Otswitch:Reusable Hand Switching Pencil: Reusable Patient Plate Bipolar Forceps: Forceps Corduniversal Adaptor, 17. Centrifuge Speed Regulator, Digital Speed Meter And 0 To 60 Min Timer Rotor 32 X 5 Ml Angle Head With Polypropylene Tu.S Easy Lid Lock, Elegant Front Panel, Safety Fuse, Stepless Speed Regulator.Maximum Speed 5000 To 5200Rpm Maximum Rcf (Relative Centrifuge Force) 3000 To3600g Maximum Capacity 250-300 Mlcalibration Certificate . . Produced At The Time Of Installation, 18. Crash Cart Trolley Crash Cart/Drug Trolley Stainless Steel Frame With Six Smooth Running Drawers. Mobile On 12.5Cm. Swivel Castors With I.V. Rod, Lamp, Massage Board; Six Hand Out Bins, Cylinder Cage. Fixed With Buffers. Size: (71W X 40D X 152H) Cm. Epoxy Powder Coated With Black Colour With 50 Microns Minimum Coating, 19. Defibrillator Defibrillator With Cardiac Monitor Biphasic, Manual And Aed With Voice Prompt, Compact And Light Weight Energy Selection 5J To 200J In Steps. Momentary Energy Selection Access On Front Panel. Adult And Pediatric Paddles Integrated On Same Handle. Momentary Charge Key On Front Panel And On The Apex Hand. Monitor . Display Selected And Delivered Energy Disarm Facility. Energy . . Delivered Within 30Ms After The Detected R Wave In Synchronization Mode. Charging Time Maximum 5 Sec For 200J. . . Battery Back Up For 50 Discharges Of 200J. . . Ecg Inputs Through Paddles Or 3 Lead Cables. . . Display For Selected Ecg Input Source(I, Ii, Iii, Paddles) Lead Off Message . Appear With Alert Tone. Amplitude Gain Of Ecg Waveform . . Adjustable Display For Heart Rate. Alarm For High And Low Hr An Inbuilt Thermal Recorder. Enable/Disable Option For Printer Supply 2 Bottle Of Jelly, 12 Roll Of Thermal Paper. Three Pairs Of Aed Pads . Operate On Mains 230V, 50Hz, 20. Dental Chair With X Ray Unit Dental Chair With Unit Dental Unit And Chair And Dental X Ray Fully Loaded Dental Chair Mount Unit With Operating Stool: Description: Compact Dental Clinic Will . Dental Unit Attached To The Dental Chair. Dental Unit Consisting Of Various Gadgets For Performing Various Dental Treatments. Mainly Consists Of Good Light Adjustable Instrument Tray Consisting Of Rotary System, Suction System And Drainage System With Spittoon, Air And Water Spray System, Uv Light For Airing Epoxy Resins In Oral Prophylaxis. Power Supply 200 To 240 Volts Ac, 50 Hz. Specification For Compact Dental Clinic Consisting Of Chair:Base Made Of Strong And Rust Proof Material. Electrically Operated All Position Chair. Body Controlled Top With Adjustable Arm Rest. Articulated Head Rest. Good Halogen Light With 2 Intensities. Euro Moulded Seat And Adjustable Backrest. Suction And Drainage System:Auto Water Connection For Spit Ton And Tumbler. Motorized Suction High And Low Vacuum. Self Drain And Self Motorized Flush System. Modular System: Micro Motor, Brush Less Type Giving At Least 45,000 Rpm Coreless Type. Contra Angle And Straight Hand Piece With Minimum 25,000 Rpm Speed. Air Rotor Hand Piece With Speed Of Approx. 4, 00,000.00 Rpm. Three Way Syringe. X Ray Viewer. Scalar Unit (Ultra Sonic Easy Type Scalar Unit With Hand Piece With 4 Tips). Light Cure Unit With Gun. Ocusing Tip, Filler, Bulb, Eye Protection. Air Compressor:Oil Free Medical Grade Mono Blocks 1.0 Hp Air Compressor With 100 Liter Displacement Of Air / Minute And Pressure Of 100 Psi With Less Noise. Drain Valve. Safety Release Valve. Automatic Cut Off. Thermo Cut Out. Auto Head Air Release System. Epoxy Powder Coated Tank. Dental Operator Stool: Made Of Strong Rust Proof Material. Moving On 5 Wheels With Euro Moulded Seat, Backrest, And Pneumatic System For Upward And Downward Movements, 21. Digital Pure Tone Audiometer Wide And Narrow Band Masking And Speech Band Masking. . . Supplied With Hd-01 As Standard And . Accept Both 8 And 10 Ohms Headphones. Tone Decay Test . . Available Along With Pulse Tone Warble Tone And + 10Db Facility. Special Filter . . In Speech Mode (Off / 2K / 4 K And 6 K). Digital Calibration . . Calibrated From Front Panel With Combination Of Keys (No Moving Any Part Inside The Audiometer). There . . Socket For External Battery Input. Technical Specification :Input Voltage : Ac 230 Volts 50 Hz / Dc 12 Volts. Pure Tone Frequencies : Air Conduction : 125 Hz To 8 Khz (Maximum 120 Db). Speech : 100 Db.Bone Conduction : 250 Hz To 6 Khz (Maximum 70 Db). Noise : Wide, Narrow And Speech Band. Attenuator (Masking) In Steps Of 5Db. Masking Range 0 Db To 100 Db.Weight : 1.5 Kg Nett. With Bag 4 Kg (Approx) .Dimensions In Cm : 20 Cm X 27 Cm X 8.5 Cm. Accessories : Audio Cups, 22. Digital X Ray (300Ma And Cr Mamogram Compatible 40 / 60Kv ,300 Khz High Frequency Dental X Ray System. The Very High Frequncy Of The System Reduces Radiation Exposure Upto 30% Compared To The Standered Generator. The Very Simple Electronic Timer Helps To Select The Correct Exposure Setting Easily. This System Operates Well With Both Film And Digital Adiography.Specificationx-Ray Generator 300Khz High Freqency.Focal Spot 0.7 Mm Cei.Tu. Current 60Kv.Mounting Option All/Ceiling /Mobile/Floor.Arm Lengths Short (170 Cm/67 In)Standard (188 Cm/84 In)Long (205 Cm /81 In)Timer Manual Time Setting, Film Or Digital Mode, 23. Direct Laryngoscope Adult Pedic Neuolaryngoscope Adult And Pediatric . Supply 4 Different Size Standard Blades And One Handle For Adult And Pediatric Separately And One Short Stubby Handle . . Stainless Steel Matt Finished. . Provide Curved Blades For Both Adult And Pediatric. An Extra Large Blade . . Supplied Along With Each Scope. Laryngoscope Neonatal Different Size Standard Blades And One Handle. Stainless Steel Matt Finished. Provide Straight Blades, 24. Direct Ophthalmoscope Specifications Rechargeable Battery With Charger/Mains Operated.. . Halogen/Led Light Source. Red Free Filters. Small And Large Spot Zes, Ationtargets, Slitaperture ,Hemi-Spot And Cobalt Blue Filter. Wheel Controlwith Power Ranging From Plus 20D To Minus35 In Single Diopter Steps Up To 10D And 5D Steps Above That. Illuminated Lens Dial. Rub.R Brow Rest. Dust Free Optics And A Spherical Optical System Supplied With A Carrying Case, 25. Dressing Trolley (As Per Standard Specification), 26. Ecg Machine (12Channels) Technical Specifications Ecg Recording With 12 Leads Standard Leads (The Limb Leads Or Bipolar Limb Leads: I, Ii And Iii) Augmented Limb Leads (Avl, Avr And Avf) Chest Leads ( The Unipolar Or V Leads)- From V1 To V6 Simultaneous Acquisition From 12 Leads Recording Speed Selection Of 25 Mm/ Sec And 50 Mm/ Secwith Facility For Speed Selection Automatic Adjustment Of Baseline For Optimal Recording. . Different Filters Like Baseline Filter, Emg Filter And Ac Filter Multiple Operating Modes Automatic, Manual And Rhythm -Common Mode Rejection Ratio >90Db4 Builtin Ecg Parameters Measurement And Interpretation-Built-In Ecg Auto Measurement Including: Hr, P R Interval, P-Duration, Qrs Duration, Q-T Interval, Q-Tcf (Friedericia), P Axis, Qrs Axis, T Axis, R(V5), S(V1), R(V5) Plus S(V1) Qtcf Interval Reading/ Measurement . Also . Available With Limb Leads Alone . 5 Printing And Communication High Resolution Thermal Printing Array System Built In Printer . Work With Standard Universal Thermal Printer Paper, Standard Accessories The Machine . . Supplied With Power Cord , Patient Cable, User Manual And Warranty Card, Operation Manual With User Demonstration Video Cd, Interpretation, 27. Electrolyte Analyser . . Capable Of Measuring Sodium, Potassium, Chloride, Calcium Or Sodium, Potassium, Chloride Electrolyte Tests From Whole Blood, Serum, Plasma Or Urine. Analyzer . . Able To Measure At Least Four Parameters At A Time. Analyzer . . Based On Ise Technology. Or More Following Parameters . . Measured Directly: Required Rangena Blood 20 -200Mmol/L Urine 25 -1000Mmol/L K Blood 0.2 - 40Mmol/L Urine 1.0 -500Mmol/L Cl Blood 25-200Mmol/Lurine 25-500Mmol/L Ca++ Blood 0.1- 6.0Mmol/L Analyzer . . Operated On Sample Size Of 150 µl For Whole Blood Serum Or Plasma Samples 400 µl For Pre-Diluted Urine Samples. End User . . Able To Take Print Of Any Desired Parameters. Analyzer . . Measure Results In Not Less Than 55 Seconds And 90 Seconds For Urine Samples. Analyzer . . Facility For Automatic Calibration. The Sample And Reagent Handling Module . . Such That They Are Totally Enclosed Change Individual Electrode. Single Plug In Disposable Reagent And Waste Module System. Analyzer . . Able To Store Results Of At Least 125 Patients. The Electrodes Placement . . Vertical / Horizontal. Store At Least 20 Qc Samples For All Three Levels Capillary And Syringe Sampling Facility . In Built Printer And A Rs232 Port For Interfacing Perform One Point Calibration With Every Sample Run To Ensure Accurate And Precise Results Internal Sample Counter To Know No. Of Samples Performed Along With The Lot No. Of The Reagent Pack. The Pack Size Of Reagent Pack . . Bigger, At Least 800Ml Or Above For Low Inventory Maintenance. Concentration Of Sodium, Potassium, Chloride, Calcium, In Calibrant A And Calibrant B . . Specified On The Reagent Pack, 28. Elisa Reader With Washer Technical Specification 96 Wells And . . Reading Capability Of 1 To 96 Wells Individually. A Linear Measurement Range Of 0 To 3.000 Abs Wavelength Range From 400 To 750Nm. A Photometric Accuracy Of Plus Or Minus3% Or .Tter A Resolution Of 0.001Abs. Variable Speed Plate Shaking Capability Easy Access 8 Position Filter Wheel Machine . . Supplied With 4 Standard Filters. Automatic Filter Selection Automatic Calibration .Fore Each Reading. At Least 6 Second Reading Speed. Facility For Storage Of Calibration Curves. Capable Of Doing Multi Standard Tests And Controls. Different Types Of Blanking Facility Like Air Wise And Well Wise Capable Of Reading U, V And Flat Type Wells Capable Of Reading 8 Or 12 Well Strip Plates. Use Halogen Light Source And Two Spare Bulbs . . Provided. . Internal Thermal Printer And 5 Rolls Of Thermal . . Supplied With The Unit.. . External Printer Connectivity Option. Work With Input 200 To 240Vac 50 Hz Supply., 29. Emergency And Recovery Trolley Emergency Recovery Trolley The System Consists Of Two Under Carriages And One Stretcher. Overall Approx. Size Of The Stretcher On Trolley 2030Mm L X 560Mm W X 900Mm H. Ms Tubular Frame Mounted On Four Swivel Castors, 200Mm Dia. The Under Carriage Over From One Carriage To Another On Roller Stretcher Can . Raised At One End On Ratchet. Ss Iv Rod With Two Locations In Each Unit. Gas Cylinder Provision In On Under Carriage. Pretreated And Powder Coated Seamens Gray Minimum 50 Microns, 30. Ent Operating Microscope Technical Specifications Of Operating Microscope Ent. Floor Stand Rollable Floor Stand On Base With Lockable Castors, Carrier And Swivel Arms With Large Reach Of 1.30 M Or Higher, . . Free Float Magnetic System With Six Magnetic Brakes Three Brakes For Microscope Body And Three For Microscope Stand With, Release Of Magnetic Brakes By Handgrips.Manipulation To Any Position With Locking Microscope Body Motorized Zoom Magnification System With Advanced Apochromatic Optics. Zoom Magnification Factors 0.4X To 2.4X Activation By Handgrip And Foot Control Panel. Total Magnification Range 2 X To 18 X Or .Tter Activated By Hand Grip And Foot Control Without Exchange Of Objective Lens. Integrated Continuously Variable Illumination Field From 60Mm-15Mm Or Less. Internal Motorized Fine Focusing System Activated By Hand Grip And Foot Control Continuously. Adjustable Working Distance From 200-225 Mm To 500-525 Mm Or More Without Exchange Of Objective Lens, Integrated Continuously Variable Illumination Field Spot Sizebinocular Tu. 180 Degree Or More Tilt Able Binocular Tu. With Focal Length F= 200 Mm Or Moregraduated Knob For Continuous Adjustment Of Inter-Pupillary Distance From 55 Mm To 75 Mm. Eye Piece Pair Of Wide Field Push In Eye Piece 10X With Magnetic Locks Diopter Setting From -8 D To +5 D, Also Suitable For Spectacles Wearers Illumination System Coaxial Xenon Illumination Minimum 300 Watt With A Back Up Quick Easy Lamp Changer Halogen Or Xenon Bulb Handgripseasily Adjustable Handgrips With Keys For Zoom And Focus, Illumination And Magnetic Brakesprogramming For Magnetic Brake For Control Of Stand And Microscope Body Brakes Fine Easy Auto-Balance Function With Touch Of A Button/Touch Screen Panel., 31. Examination Lamp, Mobile Led Lamp With Articulated Arm With Autoclavable Handle Mobile On 5 Castors Of Approx. 60 Mm Light Head Approx. 300 Mm Light Intensity >15.000 Lux At 1 Meter Colour Temperatures, Approx 3.500, 4.000 And 4.500 Kelvin Working Distance From Approx. 500 - 1500 Mm Led Or Halogen Light Source Lifetime Of Led Light Is At Least 20.000 Hours Integrated On/Off Switch Button, 32. Examination Table With Examination Table With Under Table Cabinet. Rectangular Frame Four Strong Legs With Connecting Rods And Pvc Shoes. All Components . . Thoroughly In House Pretreated Chemically To Remove Rust, Grease, Oil, Etc. By Dip Tank Processes, Including Separate Degrasing, Pickling, Phosphating Each Followed By Water Rinsing Passivating And Hot Air Drying To Give Phosphate Coating Mattress Of Suitable Size With Good Quality Rexine Cover.183Cm Lx76cm Bx7cm W. Three Drawer And Three Cabinet (With Locks) Under The Table Inbuilt Foot Step, 33. Finger Tip Pulse Oxymeter (As Per Standard Specification), 34. Three Part Differencial Hemotology Cell Counter Echnical Specification For 3 Part Hematology Analyzer No Particulars . . Double Cham.R . . Measuring Time: 60 Seconds/ Sample . . Results: 18 Parameters With 3 Histogram. . To Save 1, 00,000 Patient Data. . Minimum 7 Inch Display With Touch Screen Operation. . Sample Volume: Must . Less Than 12µl For Whole Blood . . Reagents: Instrument . Operate With Only 2 Reagents. . Support Lis . Support External Laser Jet Printer, Without The Computer . . Barcode For Samples And Reagents . . Cyanide-Free Method For Hemoglobin Measurement . . Qc Review Option With Lj Graph For 3 Levels, 35. Foetal Dopler Technical Specifications . . Handy, Work On Rechargeable Battery . . An On/Off Switch . . An Lcd Display For Fhr . . Auto Counting. . . Pro. Storage Facility To Avoid Accidental Falling . . Facility To Control The Volume Of Fhr Sound . Provide Rechargeable Battery Along With Echarging Unit. . . Automatic Power Off Facility. Battery Level Indication10.. . Supplied With A Carry Pouch., 36. Foot Step Foot Step-Double Overall Size: 18Inx9inx20in Top Sheet: 18 Gauge S.S. Design: Top Fitted With Aluminium Tread Flats. Height 9Inch And 20Inch 1Inch Sq.16 Swg Ss Pipes To . Used. 4 Nos. Nylon Feet, 37. Fully Automated Biochemistry Analyser Optical System Of Static Photometer With 8 Filterstriple Cuvette System Two Levels Of Quality Control With Levy Jennings Plot 150 Open Test Programs, Selectable Through Keypad Optical System Of Static Photometer With 8 Filters Automatic Calibration Against Standard High Resolution Lcd Display With Backlit View Product Applications: Clinical Chemistry Tests Including Electrolytes, Mmunoturbidimetric Assays, Coagulation Test Technical Specification Test Programme: 150 Totally Open Test Programs, Directly Selectable Through Keypad Ptical System: Static Photometer Filters: 8 Interference Filters (340, 405, 450, 505, 546, 578, 630 And 670 N.M.) Photometric Range: 0-3.0 Od With Resolution Of 0.0001 Abs. Precision: .Tter Than 1 % Cv Light Source: Halogen Lamp 12V / 20 Wattsdetector: 8 Silicon Uv/Vis Photodiode Array Cuvette: Unique Triple Cuvette System, 18µl Flow Cell Cuvette, Rectangular Polystyrene Cuvette, Round Glass Tu. For Coagulation Aspiration Volume: From 300 µl To 999 µl Zero Set: Automatic Temperature Control: Microprocessor Controlled Peltier Element, Programmable At 25Degc, 30Degc And 37Degc And Off Memory Storage: 1000 Results, 2 Levels Monthly Q.C. Data, Reagent Blank Calibration: Automatic Against Standard On-Board Self-Test: Software Driven Self-Diagnosis For Easy Maintenance Keyboard: 24 Keys, Rugged, Water Proof, Tactile Legend Membrane Panel Display: High Resolution Graphic Lcd 240 X 64 Dots With Backlit View Area 134 Mm X 40 Mmpower Requirements: 115/230 V Ac (Plus Or Minus10%), 50/60 Hz, 38. Fumigator (Fogging Machine) Particle Size 1-30Microns ( Convertible For Dry Fog Wet Fog)Power Input 220-240 Volts, Ac, With Liquid Flow Rate 1.5-9 Ltr/ Hr, Timer- Adjustable. Air Velocity 130 M/Sec., Throw Area 30-40 Ft. And 20-25 Feet Height Area Coverage More Than 12000 Cubic Feet.Motor Speed- Approx. 22000 Rpm (Approx.). Machine . . Stainless Steel (Autoclavable) Tank With More 5 Liters Capacity. Tank Gasket . . Silicon Grade., 39. General Surgery Laparoscope Set (As Per Standard Specification), 40. Glucometer Portable Hand Held Glucometer 1.1 Clinical Purpose It Intended To . Used Together For Testing, Either At The Point-Of-Care Or Inself-Testingbyalayperson,Forthequantitativemeasurementofglucoseand/Or Ketonesin Awhole Blood Clinica Spec Used By Clinical Department/Ward Technical Characteristics (Specific To This Type Of Device) . . Reading Range/Linearity From 20 To 600 Mg/Dl; . . A Maximum Reading Time Of Less Than 10 Seconds; . Use A Minimum Blood Sample Less Than 1.5µl; Easy Code Entry Techniqueanddisplayof Sugarinmg / Dlandnotinmilimoles. Users Interface Lcd Display, 41. Gonio Lens 4 Mirror G-4 High Mag Field Of View 4 X 64Degimage Magnification 1.5 X3 Mirror Goniolens, 42. Head Mirror Led . . Comfortable And Mobile Led Head Light And Eay To Use Without Any Cables . . Maximum Luminous Intensity Of Around 50,000 Lux Or More . . Color Temperature Of 500K. . Minimum Battery Service Life Of 6 Hours After Full Charge Batteries . . Capable Of .Ing Charged Easily Without Powering Off . . Integrated Battery Status Indicators . . Comfortable Through A Removable, Washable Headband, 43. Hot Air Oven Hot Air Oven Microprocessor Based, Pid Digital Temperature Indicator Cum Controller, Resolution: Plus Or Minus0.1Degc.Pt-100 Sensor. Temperature Range: Ambient+5Degc Up To 200Degc, Accuracy: Plus Or Minus2degc.Rced Air Circulation For Uniform Temperature. Inner Cham.R Made Of Stainless Steel 304 Grade. Outer Made Of Mild Steel, Powder Coated. Insulation: Glass Woolhandle Cum Lock For Positive Closure. Door Sealing With As.Stos Gasketwith Ss Meshed Trays. Specimen Protection Is Provided., 44. Icu Cots . . A Height Adjustable, Manually Operated, Four Section Cots With Perforated Top. The Size . . Approximately 2250Mm Length, 1015Mm Width And An Approximate Height Adjustable From 520 To 820Mm With Plus Or Minus 5% Tolerance . . A Trendelenburg And Reverse Trendelenburg Movements. . . Swiveling Non-Corrosive, Fi.R / Synthetic Wheels Of 125Mm Dia. 2 With Brake And 2 Without Brake. Provide With A Detachable And Collapsible Railing Made Of Stainless Steel Of Minimum 19Mm Diameter And 18 Gauge Tu.S Housed In Mild Steel Tubular Frame, With A Locking Facility For Raised Position. . . A Provision To Fix On All Four Corners Of The .D And In The Middle Of The .D On Either Side . . Provided With Mattress Of 4 Section, 4Inch Thick Pu Foam Of 40 Density And Pillows Covered With Soft Water Proof Material, Pvc Rexin. . . Supplied With Mattress Size . . Approximately 2010Mmx910mmx100mm With 10% Tolerance. Icu .D . . Of Minimum 130Kg Weight ., 45. Icu Cots With .D With Ivs Pole Four Sections. Top Flat Platform . . Made Of Perforated Crc Sheet Of Thickness Of 16G Or .Tter. Frame Must . Sturdy And Stable To Support Weight Of At Least 200 Kg. The Rame Structure . . Made Up Of At Least 16 G Crc, Rectangular / Circular Pipe Of 100 Mm X 30 Mm. Frame Mounted On Trolley Base Made Up Of 100Mmx30mm Cr C Rectangular Pipe Of 16 Gauge All Adjustments For Fowler Position Must . Obtained From Crank Shaft, Manually Operated With Stainless Steel Foldable Andle On Both The Shaft. The Finished .D Must . Rust Proof, Pretreated And Polished Stainless Steel. Telescopic Side Rails Of Stainless Steel Of 22 Gauze With Spring Loaded Locking Arrangement On Both Sides . . Easily Removable Head And Foot Panels Made Up Of Abs Plastic. Fowler .D . . Of Following Dimension: Mattress Area Of Length 2000 To 2010 M M X Width 900 To 910Mmheight: 500 To 550Mm (Without Mattress) . . Strong And Good Quality Doubled Wheeled Total Locking Type Swivel Castors Of 125 To 150 Mm Diameter With Breaks On Both Sides For Stabilized Position.There . . Suitable Buffer Mechanism To Avoid Hitting Of The .D To The Wall From All Sides. . . Provision Of Fixing Suitable Rod For Hanging Intravenous / Irrigation Fluid Bottle On Both Sides At Head End And Foot End. Each .D . . Supplied With 2 Nos. Good Quality Telescopic I.V. Rods With Four Hooks On Each. . . Hooks On .D Frame On Both Side For Holding Urine / Rainage Bag (At Least 4 Nos. On Each Side). Hooks . . In Turned To Prevent Injury To Bystander, 46. Icu Cots With Hydraulic .. . Divided Into 2 Sections Provides For Two Different Position Adjustments.Single Crank Mechanism With A Non-Detachable And Single Inward Folding Ss Handle For Backrest.The Uniformly Perforated 2 Section Mattress Area Dissipates Heat And Moisture, Ventilates The Mattress And Facilitates Hygiene. S S Framed Head And Foot Bows With Laminated Panels To . Provided For Ease Of Access And For Aesthetic Look. Corner Buffers To . Provided To Absorb Impact And Reduce Damage In Handling.Saline Stand Provision To . Provided At Four Locations. .D Frame To . Supported By 4 Legs With Rub.R Shoes Covering The Ends To Prevent Rusting.Urine Bag Holder To . Provided On The .D. The Complete Metal Components To . Pre- Treated And Powder Coated. Overall Size To . 2165X920x610 Mm. Back Rest Tilt To . 70 Degrees , With Hydraulic, 47. Impedence Audio Meter Impedance Audiometer 1.Pro. Tone: 220 Or 226 Hz/678Hz/1000Hz (For Pediatric Testing Also) Pro. Assembly With Contralateral Test Facility (With Supra Aural Earphones: Tdh 39/Tdh39a/Tdh49/Tdh49a/Tdh 50 With Mx 41 Ar Ear Cushions Or Insert Earphones (Er Tone 3A) 3. Test Cavities (0.5, 2, 5 Cc) Pro. Tips Assorted . . Printer Tests Required A. Compensated Tympanometry (Ear Canal Volume And Tympanometric Peak Pressure) B. Ipsilateral And Contralateral Acoustic Reflexes C. Eustachian Tu. Function Tests Intact And Perforated Air Pressure Range: Plus 200Da Pa To 400 Da Pa Stimuli For Acoustic Reflexes: A. Type: Pure Tones B. Frequencies: 500Hz, 1000Hz, 2000Hz And 4000Hz Ic. Ntensity : Up To 120 Db Hl Power Supply: Battery Operated And Main 10. . Operate In 200 To 240 V Ac 50 Hz, 48. Incubator Microprocessor Based, Pid Digital Temperature Indicator Cum Controller,Resolution: Plus Or Minus0.1Degc.Pt 100 Sensor.Temperature Range: Ambient+5Degc Up To 70Degc.Temperature Control Accuracy: Plus Or Minus 1Degc, Plus Or Minus1 Digit. Orced Air Circulation For Uniform Temperature.Nner Cham.R Made Of Stainless Steel 304 Grade. Outer Made Of Mild Steel, Powder Coated. Insulation: Glass Woolmagnetic Gasket, Handle Cum Lock On Door.Glass Window On Door For Viewing The Cham.R. Built In Lighting Arrangement.With Ss Meshed Trays.Automatic High Temperature Safety Cut Off, 49. Infusion Pump Operated On Drip Rate Peristaltic Finger Pump Method. . Compatible With Most Of The Iv Set (Macro/Micro Drip Sets). . . The Following Flow Rates.Iv Set Ml/Hr Drops/Min15 Drops/Ml 3~450Ml/Hr 1~100Drops/Min 20Drops/Ml 3~450Ml/Hr 1~100Drops/Min60drops/Ml 1~100Ml/Hr 1~100Drops/Min . . A Flow Rate Accuracy Of Plus Or Minus10% And Drip Rate Accuracy Of Plus Or Minus2%. . . A Volume Infused Display From 0 To 999.9Ml. . . A Audible And Visual Alarm For Occlusion Pressure, Air Alarm, Door Open, Empty, Low Battery. . . A Lcd Display With Backlight And Graphical Display Of Infusion . . A Minimum 2Hr Battery Back Up At Highest Delivery Rate.. Work With Input 200 To 240Vac 50 Hz Supply., 50. Instrument Trolley Overall Approx Size: 680 Mm Lx 450 Mm W X 900 Mm H. Sturdy Frame Work Made Up Of 16 Gauge S.S 304 1Inch Tubular Frame Mounted On Four Castors Of 100 Mm Dia. Two Stainless Steel 16 Gauge 304 Grade, Double Press .Nt, Mirror Polished Shelves With 10 Mm. Ss Rod, 51. Jaundice Meter Specification For Jaundice Meter . Jaundice Meter . . Of Following Specifications Non Invasive Measurement With No Consumables. . Use A Light Source Preferably Pulse Xenon Arc Lamp To Carry Out Readings Detectors Silicon Photodiodes . . Light Weigh Not More Than 210 Gm With Integrated Rechargeable Battery . . Capable Of Doing At Least 250 Measurements On A Full Charge. Battery . . Easily Rechargeable (2Hrs) . . A Choice Of Taking Readings, .Tween Single, 2-5 Measurements As An Average . . An Internal Memory Backup Of At Least 100 Readings . . Connectivity For Electronic Medical Record (Emr) For Data Transfer J. . Provide Fast, Accurate Entry Of Nurse And Patient Identification Information, Barcode Scanner Can . Optional . Charging Station To Check Calibration On Light Wavelength. Work With All Skin Colour M.Measuring Range 0.0 Mg/Dl To 20 Mg/Dl. Or 0 340 µmol/L, 52. Labour Cot (Fully Automatic With Remote With Panel And Remote) It . . An Electro Hydraulic Table, Capable Of Operation By A Hand Remote Control Unit There . . An Override Controls On The Column Of The Table. Stable Base Construction With 4 Double Swivel Castors For Easy Motion And Manoeuvring (Locking Of The Double Swivel Castors Via A Foot Pedal) Inbuilt Battery With A Capacity Of One Week Battery Life Lectro Hydraulically Operated Movements Of Height, Tilting, Back Plate And Trendelburg Base Cover Made Of Glass Fi.R Reinforced For Resistant To Cracks/ Breakages And Disinfectantstable Top Padding . . Multi Layered, Min 75 Mm Thick To Avoid Pressure Related Complications. Reverse Positioning Of Patients On A Special .Er Plate That Can . Connected At The Foot End Of The Table Top The Line Power Supply 100 To 240 Vac, Frequency Of 50 Hz Ength Of Table Top : 2100 Mm Or Above Width Of Seat/Lower Back Plate Without Side Rails : 520 Mm Or Above Width Of Seat/Lower Back Plate With Side Rails: 560 Mm Or Above Max. Patient Weight - 360 Kg Or Above. Following Electro Hydraulic Adjustments:Via Corded Hand Control Or Override Control Panel, With Status Indicators For Battery Charge Level And Base Brake Feature, Located At The Column Head. Height Without Padding: 590 940 Mm Or .Tter Trendelenburg/Reverse Trendelenburg: + 23Deg / - 23Deg Or .Tter Ateral Tilt :12Deg Or .Tter Lower Back Plate: + 70Deg / - 35Deg 0-Position (Horizontal Alignment Of The Table Top) From Hand Control.Standard Accessories To . Supplied With The Table From The Same Manufactur Arm Board With Ball And Socket Joint With Clamps Qty 2 Nosbody Strap With 2 Clips For Fastening Side Rails -1Set Lithotomy Leg Holder Pair With Clamps -1Set.Dual Abductable Leg Plate For Gynecologic Laparoscopic Surgery -1No., 53. Lamp Floor Model Led Lamp With Articulated Arm With Autoclavable Handle Mobile On 5 Castors Of Approx. 60 Mm Light Head Approx. 300 Mm Light Intensity >15.000 Lux At 1 Meter 3 Colour Emperatures, Approx 3.500, 4.000 And 4.500 Kelvin Working Distance From Approx. 500 - 1500 Mm Led Or Halogen Light Source Lifetime Of Led Light Is At Least 20.000 Hours Integrated On/Off Switch Button With Integrated Transformer, 54. Led Vision Chart (Snellen Chart) Display 24 Inch Led Backlite Resolution 1920 X 1080 @ 75 Hz Chart Window Size 534 X 300Mmncontrast/ Bright 1000:1/250 Cd/M2 Standard Chart Type Letters, Num.Rs, Tumbling E, Paediatric, Landolt C, Languages, Contrast,Log Mar, Snellenchart, Crowding Bar, Single Row, Single Column, Single Letter. Range 1Ft To 0Ft (1Mt To 6Mt) Special Chart Type Astigmatism, Fixation Target, Fixation Disparity, Amsler Grid, Polarization Test, Vernier Acuity, Pelli-Robson Contrast Test, Lea Symbols, Lea Num.Rs, Kay Pictures, Phoria Test, Singal Test, Hotvx Test,Worth 4 Dot, Cross Cylinder Test, Fan And Block Test, Dot Chart, Anisekonia,Ishihara, Etdrs Chart, Duo Colour For All Charts Etc. Mutimedia Images, Video, Animation (Usb Support) Distance Of Installation 1M 6M (Step By 1 Meter) Chart Change Over Device Remote Control, 55. Lensometer Accurate Measurements With External Power Reading Dual Power Supply System . . Clear Green Illumination Target . . Energy Efficient Led Illumination Possibility Of Accurate Centering And Marking Of Lenses Lens Meter Light Weight Thermal Printer Colour Monitor Compatible Power Supply Contact Lens Stand, Rolls Of Printing Paper, Measurement Range Lens Power Minus 20 To Plus 20 D Or More (Sphere) Minus 10 To Plus 10 D Or More (Cylinder) 0 To 5 P D Or More (Prism) Measurable Lenssingle, Multifocal, Progressive Frame Lenses And Hard And Soft Contact Lensesstep 0.25 D In 0 D To Plus Or Minus10 D 0 .50 D In Plus Or Minus10 To Plus Or Minus25 D Cylinder Axis 1Deg To 180Deg In 1Deg Step Prismatic Power 0 Prisim To 6 Prism In 1 Prism Step Other Parameters Eyepiece Adjustment Minus 5 D To Plus 5 Dacceptable Lens Diameter㸠20 Mm To ø 80 Mm Light Source 3 V, 20 Ma Green Led, 56. Microscope Binocular Specifications Binocular Fram Coaxial Coarse/Fine Knobs : Tension Adjustment On The Right Side Fine Focus Knob Graduated Stage Movement (Xy Direction ) On Rack And Pinion Quadruple Revolving Nosepiece (Fixed) Plane Stage 120 X 132 Mm With Right Hand Mechanical Stage Ab. Condenser N.A. 1.25 (Oil Immersion), With Aperture Iris Diaphragmblue Filter Universal Power Supply (100 V To 240 V) For 6V 20 W Illuminator 8Cc Immersion Oil Dust Cover Mirror Unit(Plano Concave) Observationtu.Binocular Observation Tu. (Inclination 45 Degree, Interpupillary Distance Adjustment Range 53 To 75Mm ), Diopter Adjustment On The Left Trinocular Observation Tu. (Inclination 45 Degree ), Diopter Adjustment On The Left Objectives 4X(Anti Fungus) 10X(Anti Fungus) 40X(Anti Fungus) Spring 100X(Anti-Fungus) Spring,Oil Eyepieceicwhk 10X (Lb Eyepiece 10 X), F.N. 18 Mm, (Anti Fungus) (X2) Lamp6v 20 W Halogen Lamp (X2)Power Cord, 57. Microscope Labadvanced Features:Antifungus Optics (Sealed Optical Parts),Interchangeability Of Optics.Ab. Condenser And Light Relay System Are Fitted With High Performance Aspheric Lenses For Bright And Crisp Image.Illumination System Through Smps Circuit Etc. In-Built 6V, 20W Halogen Light Lluminator.Coaxial Coarse And Fine Roller Guide (Comfortable Position Of Focusing Knobs). Tension Adjustment On Ight. Quadruple Revolving Nosepiece.Large Stage 120X132mm.With Mechanical Stage Right Hand Drive. Ab. Condenser 1.25, With Aperture Iris Diaphragm, Blue Filter. Anti-Fungus Achromatic Objectives: Ine 4X, Ine 10X, Ine 40X (Spring), Ine 100X (Spring, Oil Immersion). Paired Eyepiece Wide Field Icwhk 10X. In Thermocole Pack, 58. Mobile Ot Lights Specifications: Intensity: 80,000 Lux Plus Or Minus10%Size Of Light Field: 12-30 Cmcolour Temperature: 4000-5000 Kcolour Reduction Index: 93 Ra Led Life: >50000 Hrs.Diameter Of Light 600Mmbrightness Control Capacitive Touch Panel Power Supply: 220V/50Hz Acfocusing Adjustable, 59. Modular Medical Gas Pipe Line Systems( As Enclosed Detailed Specification), 60. Modular Monitor With Etco2 Specification Of Portable Type-Patient Monitor (Ecg,Resp,Spo2,Nibp, Temp, 2Ibp,Etco2) True Modular Vital Sign Monitor Suitable For Use In Advanced Surgical Procedures, Clinical Investigations And Research With Scope For Future Up-Gradation . . Quoted Advanced Modular Patient Monitor Having Integrated Basic Measurements And Features With Capability To Provide Additional Clinical Measurements By Attaching Interchangeable Single/ Dual/ Multi-Parameter Modules/ Servers The Monitors . . Bright, Highly Visible, Minimum 12 Inch Colour Touch Display For Easy Viewing From A Distance In A Large Intensive Care Unit.The Unit Must . A Inbuilt Continuous Battery Backup Of Minimum 3 Hours . . The Capability To Display At Least 6 Real Time Waveforms Along With Related Numerical Parameters On A Single Screen The Monitor . . 12 Lead Ecg Display (Simultaneous) With Capability To Derive 12 Leads With 5/6 Lead Ecg Cable Only With Graphical Representation Of 12 Lead St Segment Analysis. - The Size Of The Numeric . . Adjustable And Capable To .Come Bigger For Viewing From Very Long Distance. The Size Adjustment . . Easily Done Using The Keys On The Screen By The User.- The Monitor . . The Capability To . Operated Through Full Touch Screen Operation. The Monitors . . The Capability To Monitor Ecg, Respiration, Nbp, Masimo Set Spo2, 2 X Invasive Pressure.-Mainstream Etco2 With Inspiratory And Expiratory Measurement 5 Nos Interchangeable Modules To . Supplied With Complete Supply . . Capability To Get Upgraded To Connect Third Party Devices Such As Ventilators, Syringe Pumps Etc.- The Monitor . . Capable To Display 48 Hours Trends For All Monitored Parameters. Time Resolution For Trends . . Selectable.- It . . The Capability To Provide Event Review Based On The Events Defined By The User Of The Monitor As Per The Specific Condition Of The Patient.-The Monitor . . Able To Work On Mains Even If Batteries Need To . Removed.- All Standard Accessories Required To Run All The Parameters Mentioned Above To . Provided With The Unit, 61. Modular Ot With Laminar Floor Modular Wall Panel Supply And Installation Of 0.6Mm Thick Ss Matt Finish Skin On One Side And Other Side 0.6Mm Thick Gi Powder Caoted,Puf As Infill With Density Of 20Kg/M3 Wall Panel With Supporting Tracks,Fixing Accessories And The Panel Thickness Shall . 100Mm.Modular Ceiling Panel Supply And Installation Of 0.6Mm Thick Ss Matt Finish Skin On One Side And Other Side 0.6Mm Thick Gi Powder Caoted,Puf As Infill With Density Of 40Kg/M3 Ceiling Panel With Supporting Tracks,Fixing Accessories And The Panel Thickness Shall . 50Mm. Aluminium Powder Coated Coving Supply And Installation Of 50Mm Radius Aluminium Powder Coated Coving With Back Supports. Ss 3D Corners Supply And Installation Of Ss 3D Corners For All Corners Of Cleanroom Epoxy Flooring Supply/Installation Of 3Mm Thick Epoxy Flooring. Epoxy Coving Suply And Installation Of Epoxy Coving Ot Room Doors Supply And Installation Of 0.8Mm Skin Thck Ss Honeycomb As Infill Single Leaf Door.Including Ss Dorma Make Door Closer,Ss Push Plate,Hinges,Handle Etc And Door Frame Shall . 1.2Mm Thick. Size: 1800X2100mm Return Air Risers Supply And Installation Ss Made Return Air Risers Of 800X3000mm With An Grill Of 00X150mm Air Handling Unit Supply, Installation,Testing And Commissioning Of Re-Circulatory Type Floor Mounted Double Skinned Air Handling Unit, Made Out Of 0.6Mm Pre Coated Outer And Inner Skin With 43+/-2 Mm Thick Hallow Extruded Aluminium Profile System With Puf Insulated Of 40 Kg/MⳠEnsity.Filtration Level Will . 10 Microns Pre Filter Section, 3 Micron Fine Filter Section Unit To Consider,Ss-304 Drain Tray For Dx Type Cooling Coil ,Blower Section With Backward Curved .Lt Driven Type Centrifugal Fan With Suitable Rated(Nflp)Motor And Necessary Electrical Controls,Complete Units Shall . Mounted On A Common Base Frame And Suitably Rated Neoprene Pads,Vibration Isolators, Inspection Doors,Limit Witch,View Lamps And Accessories.Gi Volume Control Damper For Supply, Return And Fresh Air. Ahu Of 4000 Cfm @ 125Mm Static , 8.5Tr Refrigeration System Supply /Installation/Testing/ Commissioning Of Air Cooled Condensing Unit Of Scroll Type Compressor With Suitable Piping(.Low Given Sizes) ,Hp Lp Control Automation Etc .Capacity 8.5 Tr Copper Piping Of Size 3/8( Apprx.10Rmt Each) Copper Piping Of Size 5/8 ( Apprx.10Rmt Each)Expansion Valve Drier Temperature Controller R-134A Gas Pvc Drain Pipe Oudoor Stands Ducting Supply And Installation Of Hand Fabricated Ducting Using Gi Sheet With Nut,Bolt,Gasket And All Joints Will . Sealed By Sealant. 24 G Insulation Supply And Installation Of Cross Linked,Closed Cell Structure Fr Xlpe Fire Retardant Class 1 Insulation Witha Density Of 30Kg/Cum With Aluminium Foil For Supply And Return Air Ducts With Suitable Adhesive. 13Mmthick Tmrsc Module With Hepa Filter Supply And Installation Of Tmrsc Hepa Module With Hepa Filters Of 99.97% Efficiency Down To 0.3 Micron With Room Side Operating Damper And Ss Perforated Sheet( For Maintaning Iso 7 Inside The Room Area). Fan Filter Unit Supply And Installation Of Fan Filter Units With An Inbuilt Blower With Motor And Heap Filter Of 99.997% Of Efficiency Down To 0.3 Micron With Ss Plenum Of Size : 2X4-2Nos 2X2-2Nos( For Maintaianing Iso 5 On Ot Table And Surgical Team). Flexible Duct Supply And Installation Of Flexible Duct Of 250Mm Dia With Rockwool Insulation Volume Control Dampers Supply And Installation Of Gi Made Volume Control Damper Of For Duct Branches And Ahu Supply Fire Damper Supply/ Installation Of Fire Damper With Fusible Link For Air Handling Units Heaters Supply And Installation Of Duct Mounted Heaters For Maintaining Erelativehumidity B/W 40 To 60%. Magnahelic Gauges Supply And Installation Of Magnahelic Gauges With Suitable Gi Powder Coated Box And P U Tu.. Range Of Gauges 0 To 50 Pascals Electrical Parelectrical Control Panel Supply / Installation/ Testing /Commissiong Of 16G Gi Powder Coated Electrical Control Panel With Dol Starters For Ahu Mccb ,Individual Mcb For Ahu And Condensing Unit .Phase Indicator, Ammeter And Voltmeter,On/Off Switch For Condensing Unit,Hp/Lp Control For Outdoor Units, Auto/Manual Switch With Temperature And Rh Controlling Sensors Etc. Cables Supply And Laying Of 4Sqmm X 4 Core Alumnium Armoured Cable From Control Panel To Ahu. Supply And Laying Of 1.5Sqmm X 4 Core Copper Flexible Cable From Control Panel To Ahu Limt Switch And Lam Supply And Laying Of 4 Sqmm X 4 Core Alumnium Armoured Cable From Condensing Units To Control Panel. Supply And Laying Of 1.5Sqmmx 2 Core Copper Flexible Cable From Temperature Sensor To Control Panel .(3 Runsx30x2).2.5 Sqmm Flxible Cable For Lightings With Conduit And Other Fitting Accessories Cable Tray Upply And Installation Of Gi Cable Tray With All Supporting Accessories Size : 50X50x100mm For Ahu, Outdoor To Control Panel Ot Room Light Fixtures Supply And Installation Of Clean Room Light Fixtures.Size 2X2 Feet Capacity Of 3X36 Watts.Make : Starlite/Pierlite Switch And Sockets Supply And Installation Of 2Switch And 2Sockets Board For Clean Rooms With Necessary Wiring And Controls. Make : Roma/.Lls/Equalant Ot Room Interior Validation Of Clean Room Which Consists Of Air Velocity Test, Filter Leak Test,Particle Count ,Recovery Test And Temperature,Rh Monitoring. Documentation Consist Of Ahu Ga Drawing,Ducting Drawing,Qualification Documents(Dq,Iq,Oq And Pq), 62. Multipara Monitor (17 )With Iabp (7) Multipara Monitor Multiparameter Monitor For Monitoring Adult, Paediatric And Neonates Basic Monitor Unit .Monitor . . Modular, With Capability Of Accepting At Least 4 Modules. It . . A Minimum 10 Or More Inch Tft Colour Display. . . Capable Of Displaying 24 Hour Trends For The Monitored Parameters User . . Able To Set Alarms For All Parameters . . Capable Of Accepting Up To 3 Invasive Pressure Modules At A Time. . . Able To Display At Least 4 Waveforms, With Facility Of Overlapping Pressure Waveforms. . Capable Of Numerically Displaying Information Of All Parameters For Which Waveforms Are .Ing Displayed, As Well As Displaying Numeric Values Of Additional Parameters If More Than 4 Modules Are .Ing Used At A Time. . . Dicom Facility And Connectivity To Computer Local Area Network (Lan) - (Preferable). Wall Mounting . . Provided. Modules :- It . . Possible For Each Monitor To Accept Modules Ecg + Respiration One Oxygen Saturation (Pulse Oximeter) One Non-Invasive Blood Pressure One Invasive Pressure Three Temperature Two Cardiac Output By Thermodilution One End-Tidal Co2 Monitoring One C)Ecgnumeric Display Of Heart Rate Range 20-300.Ats Accuracy + 1 .At Per Minute Lead And 3 Lead Ecg Cables (Two Of Each) . . Provided With Each Monitor. . . Able To Mention The Arrhythmia Type. Nibp . Measure Systolic, Diastolic And Mean Pressure Mode Of Operation : Manual, Automatic And Stat Cuff Inflation / Deflation Automatic Inflation Pressures . . Automatically Released If Error Measurement Range : 20 250 Mmhg Measurement Interval: 2 Minutes To 2 Hours (User Can Select Interval) Reusable Blood Pressure Cuff For Adults, Pediatric, Neonatal Use . . Available.( 12 Adult Cuffs, 6 Paediatric Cuffs And Two Neonatal Cuffs . . Provided. Extra Large Adult Cuff . . Provided For O.Se Patient. Pulse Oxymeter O2 Saturation: Range 1 To 100% Accuracy: + 2% .Tween 50 And 99% Motion Artifacts . Not Affect Readings Reusable Adult Or Paediatric Pro.S (Finger Pro.S 2 Nos, Multisite 2 Nos) As Required . . Provided With Each Monitor Respiration . . Part Of Ecg Module Range 0 To 150 Breaths Per Minute Resolution One Breath Accuracy: + 2 Breaths Apnea Alarm: Selectable Invasive Pressure Module: Three Modules With Eachmonitor . . Provided. Display Of Systolic, Diastolic And Mean Pressures Scale Range: 30 To 300 Mmhg (User Selectable) Measurement Range: 0 To 300 Mm Hg Pulse Rate Range: 25 To 300 .Ats Per Minute Zero Adjustment: Range + 200 Mmhg, Accuracy + 1 Mmhg. Alarm Limits: 0 To 300 Mmhg Reusable Pressure Monitoring Transducer Kit One With Each Module To . Provided Disposable Domes: 50 Pressure Domes To . Provided With Each Module. If 7 And 8 Not Possible Then Disposable Transducers 150 With Continuous Flashing System And Three Reusable Cables . . Provided. Cardiac Output Cardiac Output By Thermo Dilution Injectate Volume: 5 And 10 Ml Injectate Temperature: 0 To 27Oc Cardiac Output Range: 0.1 To 15 Litres/Minute Instrument Accuracy: + 3% Instrument Repeatability + 3% Compatible With All Ommonly Available Brands Of Pulmonary Artery Catheters. Facility To Average 5 .St Readings To Obtain Cardiac Output. Cables For Connecting Pa Catheter And Temperature Pro.S . . At Least 2 Metres Long. Temperature: Each Monitor . . Two Temperature Modules. Simultaneous Monitoring Of 2 Channels Range: 15 To 44Oc Resolution: 0.1Oc Accuracy: + 0.2Oc Skin Pro. 1 Num.R (To . Provided With Each Module) Rectal Pro. 1 Num.R (To . Provided With Each Module) End-Tidal Co2 Main Stream Monitoring Of Co2 Display Of Pco2 (Mmhg) And Concentration (%) Averaging: Breath To Breath Sampling Tu.S: 10 Num.Rs To . Provided With Each Module Printer: A Single Central Printer . . Provided Which . . Able To Print Data From Selected Monitor. . . Capable Of Printing Graphical And Tabular Trends. Able To Print Real-Time Or Saved Output Of 3 Channels E.G. Ecg And 2 Invasive Pressure. Power Supply: 230 V + 15%, 50 Hz + 3% With Built In Battery Charger And Rechargeable Battery, 63. Nebulizor Nebulizer, Ultrasonic Compressor Based Nebulizer Continuous Medication Of Babies, Children And Adults Nebulisation Of Approx. 0,4 L/Min Particle Size Mmad Approx. 3 Micro Meter, 70 % Of Particles Less Than Or Equal To 5 μm All Accessories Are Included; Power Cord (Greater Than 2M), Tu. (Greater Than 2M), Nebuliser Kit, Air Filters, Inhalation Attachments (Mouthpieces, Nosepieces, Adult Masks, Child Masks) Accessories Are Reusable And Autoclavable Stationary As Well As Portable Usage On Mobile Base With 5 Castors Of Approx. 60 Mm, 64. Nst Machine Specification For The Nst Machine: Atleast 7Inch Wide Tft Color Lcd Screen For Fetal Heart Rate , Uterine Contraction And Fetal Movement It . . Display Modes Of Trend Mode, Num.R Mode And Graph Mode. It . . Alarm Functions In All Movementit . . Facility To Increase / Decrease / Mute Alarm Sounds It . . Automatic Track And Hold Facility It . . High Sensitivity Less Than 1 Mhz Fhr Upper Limit . . 130 240 Bpm And Lower Limit . . 30 150 Bpm Fetal Heart Rate And Uterine Pressure Automatic And Manual Fetal Movement Detection Inbuilt Thermal Recorder Battery Backup For 30 Mins A Builtin Emory. Twin Fetal Monitoring Systemhr And Uc Pro.S . . A Slot Guided Connecting Mechanism To The Main Unit Print Speed Of 1, 2 ,3 Cm/Min . Automatic Paper Feeding Function Standard Accessories Us (Fhr) 4 Nos Toco Pro. 1 No Event Maker Jack 1 No Print Paper 10 Rollspower Adapter And Cord 1 No Pro. .Lt 5 Nos G. Stabilizer 1 No H. Stand For Wall Mounting Us (Fhr) Pro. Rates For 10 Years To . Quoted Separately And Fixed In The .Ginning. Power Supply 3.1. Power Input To . 220 To 240Vac, 50Hz Fitted With Indian Plug 3.2. In Built Rechargeable Battery Backup That Is Concealed In The Unit And Recharges Automatically When Connected To Ac Mains., 65. O2 Concentrator (As Per Standard Specification), 66. O2 Hoods (As Per Standard Specification), 67. Ophthalmic Unit Chair Smooth-Rotating, Well Balanced Sliding Table Top With Ample Space For Two Instruments. Automatic, Under-The-Table Connection For Slit Lamp Touch-Activated Safety Switch To Stop Inadvertent Chair Movements Integrated, Centralized Control Console With Touchstone Keys Strong Pole To Support Lamp, Phoropter, Projector And Near Vision Holder Convenient Instrument Holder Tray. Dust Free, Enclosed Trial Lens Rack With Straight, Unobtrusive, In And Out Sliding Movement, 68. Indirect Ophthalmoloscope With 20D Lens.Brilliant White Light Uniform, Well Illuminataion (Led)Full Pupil Featurestereo Optical Systemcobalt Blue And Green Filters Interpupilary Distance Djustable From 50 To75 Mm Illumination Area (1.5Mt) : 80Mm Power Supply 1/P 100V 240Vac 50Hz / 60Hz 5.3V Dc, 1 Watt Led (White Light Power Led)Battery Rechargeable.3.7V Dc 900 Mah. Li Ion Marking Pencilfundus Chart A Padscleral Depressordc Power Supply, Adaptor Co Observantion Mirrorcarrying Case20d Lens Good Quality Opticsdouble Aspheric Glass Opticsfield Or View 46 To 60, 69. Ot Light (Led) Technical Specification Ot Light Led Without Camera Led Without Camera Led Without Camera . . A Surgical Light Unit Incorporating The Latest Led Technology Shadowless Operating Light Field With The Following Specifications. . . Single Colour High Performance Leds With Life Time More Than 40,000 Hours. . . A Dual Dome And The Main Light And Satellite . . The Following Specifications Lux Intensity 1,10,000 Lux And Satellite 1,10,000 Lux Or Above. Light Field Diameter Shall . Above 24 Cm Or .Tter. Colour Temperature . . .Tween 4000 To 4500 Degree K Colour Rendering Index . Not . Less Than 95 Depth Of Illumination . Not . Less Than 100 Cm. Illumination Adjustment 30% To 100% The Light Dome Shall . Compatible For Laminar Air Flow. The Leds Must . Of A Single Color Suitable For Long Term Maintenance And Ease Of Replacement. Temperature Rise At The Surgeon Head Level . . Less Than 2 Degree C. . . Control Panel For Light Focusing Adjustment Fixed On The Dome Or Arms. . Supply Autoclavable Handle For Each Dome Unit . Function With 200 To 240Vac, 50/60 Hz Input Power Supply., 70. Ot Pendents Technical Specification Anesthesia Pendent 1 Anesthesia Pendent Systems . . The Facility To Provide Convenient Positioning Of Medical Equipment, Medical Gas Terminal Units, Electrical And Specialty Services In Operation Theatre. 2 Pendant Shall . Single Arm, Movable, Ceiling Mounted And . Modular Head 3 . . Aluminium Powder Coated Rectangular Body With One Monitor Mounting Facility And Inspection Door At Back Side. 4 Shall . Provided With Electrical 5 And 15 Arms Socket, Switch With Indicator 8 Nos. . . Provision For Gas Outlets Oxygen 2Nos., Medical Air (4 Bar) 2Nos.,Vaccum 2Nos.,Nitrous Oxide 1Nos. Complete With Hose Assemblies Can . Accommodate Within The Pendan Shall . Provided With 2Nos. Of I.V Pole With Bracket Carrying Capacity Of The Arm Will . Not Less Than 150Kgs Shall Provide A Clearance Of 1.65 To 1.95 M Above Finished Floor Level Each Pivot Point Will Rotate Up To 330Degree Pre Installation Requirements To . Submitted In Technical Bid. Supplier . Connect The Pendant To The Existing Medical Gas Pipeline System. Supplier . Supply The Necessary Accessories Required For Connect To Theanesthesia Machine . Supply 1 Nos. Of Theater Vacuum Unit (Trolley Model) With 2 X 2 Ltr. Capacitypoly Carbonate Bottle (With Safety Valve) With Hose Aong With Each Pendant . Supply 1 No. Of Oxygen Flow Meter With Humidifier As Per The Following Specification . . Back Pressure Controlled Body . . Chromium Plated Metering Tu. And Cover Made Of Unbreakable Poly Carbonate Flow Adjustment By Needle Valve Equipped With Inlet Filter 100 Micro Meter Flow Rate Range 0 15 Litres / Minute Inlet Pressure 60 Psi, 71. Ot Table (Hydraulic Table) Specification For Labor Cot And Cpr Function . . Hydraulic Up And Down, Suitable For Patient Stay And At The Time Of Need Convertible To Delivery Table All Required Ccessories I.E. Patient Hand Grips, Leg/Calf Rest, Foot Rest . . Integrated To .D And Can . Rotate And Fix. Sections Of The Delivery .Seat Part Can . Independent Motorized Tilt For .Tter Coccyx Elevation Of Mother And Comfort For Doctor/Midwives For After Delivery Tear Surgery All Sections . To . Compact, Closed, Without Sharp Edges Foot Rest Has To .: Fully Manual Adjustment .It Remains Attached To Foldable / Swivel Adjusted In Horizontal Position Possible To Hide Under The Seat Part (With The Upholstery) Angle Of The Foot Rest Adjustment: 0Deg 22Deg Leg Holders (Pair) . To .: Integrated Leg Rests May . Used As Feet Support (Foot Rest Position), In The Gynaecologic Position And In The Horizontal Position To Maximize The .D Surface Side Away For Easy Access Of Staff To The Woman In Labour (0Deg-143Deg) With Upholstery The Firm Conception Of Leg System Easy To Adjust . . Removable Headboard For Anesthesiologist . . Integrated Plastic Or Stainless Steel Bowl And Possible To Hide Under The Seat Part Remote Hand Controller With The Spiral Wire Optional. . Integrated And Foldable Side Rails With Control Panel From Patient Side . . Control Panel Em.Dded On The Side Of Controlsenabled: High And Tilt Adjustment Trendelenburg Position Lockout Position Under .D Light Nurse Call (Optional) 4 Castors With Diameter 150 Mm With A Braking System For Min. 3 Castors And One Steering Castor Integrated Holders For The Infusion Stand On The Both Sides Of The .D Within The Shape Of .D Upholstery (Mattress) : Back Part And Seat Part (One Piece) With Thickness: 100/130Mm. . . Eamless, Fully Removable. Foot Rest Mattress: Thickness: 65Mm, Seamless, Fully Removable Compact Surfaces For Easy Cleaning Maximum Patient Load 240 Kg Electric Power: 230V Back-Up Battery, 72. Oto Acoustic Emision (Oae) Oae Analyser Otoacoustic Emissions (Oae) System: Facility For Doing Teoae, Dpoae Teoae Specifications:Facility Of Click Stimulus And Tone Burst Stimulus Configurable Stimulus Intensity Band Analysis From 1 Khz To 5 Khz Or More Reproducibility In Half Octave Bands Suppression Facility Full Cross Correlation, Frequency Analysis With Reproducibility And Signal To Noise Data On Single Test Or .Tween Test Pairs Customized Teoae Protocol Dpoae Pecifications: 1. Frequency Range Minimum Of 500-10,000 Hz. 2. Num.R Of Test Points Per Octave: Minimum 30 Points Per Octave 3. Intensity: F1 And F2 Levels From 0 To 70 Db Spl, 73. Otoscope A Convenient Pocket Type Otoscope. Provided With A Halogen Light Source. Able To Detach The Otoscope Head. Provide No Reflections And Obstructions. Provide Detachable Accessories Of Various Sizes. In Built Rechargeable Battery. Recharge . . Possible With Irect Mains Supply, 74. Pulse Oxymeter . Plethismographic Wave Form With Numeric Display For Spo2 And Heart Rate On Lcd/Tft Display. . . A Spo2 Range Of 0 To 100%. . . Spo2 Accuracy Of Plus Or Minus2%. . Provide Bar Graph For Pulse Strength. Audio And Visual Alarm For Both Upper And Lower Spo2, Heart Rate. . Provide With Adult Andpeadiatric Reusable Finger Pro.S With Technology From Standard Reputed Companies...Ep Sound And Alarm Sound . . Separate Volume Control . . A Minimum Of 2 Hours Back-Up Time. . . A Portable, Light Weight And Desktop Model. 10.. Work With Input 200 To 240Vac 50 Hz Supply, 75. Patient Chair (As Per Standard Specification), 76. Pediatric Weighing Scale (As Per Standard Specification), 77. Pediatric(Steth) (As Per Standard Specification), 78. Phototherapy Unit (Double Surface Led) Phototherapy Lamp On Mobile Stand With Two Surface Infrared Light For Heat Transfer To Muscles Including Spare Light Source Height Adjustable, 1000 2000 Mm Electric Clock For Measuring Total Operational Time, And Treatment Time With Zero Reset Frame Made Of Powder Coated Steel On 5 Swivel Castors Of Approx. 60 Mm, Two With Brakes, 79. Radiant Warmer With Resuscitation Specifications : Microcomputer Controlled Radiant Heat Warmer (Servo Controlled) . Provide Controlled Warmth During Resuscitation Of Newborn Babies.Complete Stainless Steel Fabrication Including Trolley User Friendly Feather Touch Control Switches Bright Emperature Display Separate Set Temperature Display. Set Temp Range 34-38Deg C (>37.0Deg Override). Skin Temp Display 18-43Deg C. Accuracy Plus Or Minus 0.2Deg C (31Deg C To 37Deg C) Display For % Of Heater Output. Heater Output 0-100%, 10% Increments Control Mode : Air Mode/ Pre-Warm Mode And Skin Mode Pre-Warm Mode With Time Programmable, Heater Output Settable, Over Temperature Safety Cut Off. Apgar Timer : Alerts At 1, 5 And 10 Minutes. O Alarm Volume Control Preferable Ety Alarms : Pro. Failure, >10 C Of Set Temperature, <10 Of Set Temperature, >390C Airtemperature, Power Failure. Safety High Skin Temperature Cut Off At 390 C Heater Box . Consist Of Ceramic Infrared Heater The Source Box . . Swivel Type To Take X-Ray Examination Quartz Lamp 50 W With Illumination >0.11 Lumens/Cm2 (100 Ft. Candles). Attached Baby .D With Following Facilities Minimum 6Mm Thick Collapsible Side Supportsii. Baby Tray With Head Up/Down Facility Upto 45 Degrees With Thick Cushion Mattress Iii. Separate X-Ray Guide For Positioning The Cassette Iv. Open Shelves, 2 Nos. Patient Gas Supply Flow Control Range 0-15 Lpm Airway Pressure Limit- Adjustable 0-50 Cm H20. Autobreath Infant Resuscitator Adjustable Breath Rate Range 18-60 Bpm (+/-10% Of Setting)Ii. I:E Ratio Fixed At 1:2 Nominal Iii. Pressure (Peep) 0-18 H20 (0-1.77 Kpa). Gas Bleed 5 Lpm Max V. Precision Blender (Optional) 21-100% O2 +/-3% 02 Oxygen Regulator With Hose Pipe, Holding To Keep Oxygen Cylinder Of Medium Size ( 5 Liters), Flow Meter, Humidifier Bottle With Silicon Tubings Electrically Operated Suction Unit . Provide Safe Settable Suction( 0-150 Mm Hg) Required For Neonates Power Supply : 230 V Ac + 10%, 50 Hz, 80. Rebound Tonometer Specifications It . . Based On Rebound Technology. Measurement Range: 7-50 Mmhg Display Range: 0- 99 Mmhg (Iop Estimation .Yond The Measuring Range) Accuracy: (95% Tolerance Interval Relative To Manometry) Plus Or Minus 1.2 Mmhg (< 20 Mmhg) Repeatablity (Coefficient Of Ariation) :<8% Accuracy Of Display : 1 Mmhg Display Unit: Millimeter Mercury (Mmhg) There . . No Electrical Connections From The Tonometer To The Patient The Device . . B- Type Electric Shock Protection. Storage/Transportation Environment : Temperature : + 5 To 40 Degree C Rel. Humidity 10 To 80% (Without Condensation), 81. Specifications For Trial Set With Trial Frame Refraction Set All The Lenses . . Reduced Aperture With Clear Lenses Mounted On Metal Rims And . Come In Proper Holders In A Wooden Box Plus Or Minussphere Plus Or Minus Cylinder Prism Accessories List Nos. List Nos. List Nos. List Nos. List Nos. 0.12 D 2 4.50 D 2 0.12 D 2 0.50 D 1 Occluder 2 0.25D 2 5.00 D 2 0.25 D 2 1.00 D 1 Red Filter 1 0.50 D 2 5.50 D 2 0.50 D 2 2.00 D 1 Green Filter 1 0.75 D 2 6.00 D 2 0.75 D 2 3.00 D 1 Slit 1 1.00 D 2 7.00 D 1 1.00 D 2 4.00 D 1 Pin Hole (1Mm) 1 1.25 D 2 8.00 D 2 1.25 D 2 5.00 D 1 Maddox 1 1.50 D 2 9.00 D 2 1.50 D 2 6.00 D 1 1.75 D 2 10.00 2 1.75 D 2 8.00 D 1 2.00 D 2 11.00 2 2.00 D 2 10.00 D 1 2.25 D 2 12.00 2 2.25 D 2 12.00 D 1 2.50 D 2 13.00 2 2.50 D 2 2.75 D 2 14.00 2 2.75 D 2 .00 D 2 16.00 2, 82. Ro Filters Storage Capacity (Liters) 60-80, Nominal Cooling Capacity (Liters/Hr) 40 No. Of Faucets 2, Dimension (Mm) Width 660,Depth 475,Height 1215,Weight (Kg) 62,Normal Demand (Glasses Per Hr) 200 Refrigerant R-134A,Current (Amps) 2.78,Water Over Flow (Connections) 1/2 Bsp,Type Of Compressor Rotary, All-Stainless Steel Body, 83. Saline Stand Adjustable From 60 To 90 Central Stand-16 Gauge Erw 1 Sq. Pipe 4 Winged Base Each Wing Having A Length Of 9, Base Of 2 X 1 Cross Section. 10 Gauge Rectangular Tu. On 2 Swivelling Nylon Castor Wheels. A Telescopic ½ Dia S.S.304 Grade Rod With Double Hooks. Locking Hook (Grip) Ad Of Ss Stud Fitted With Bakelite Knob For Holding Saline Rod In The Position. Epoxy Powder Coated In Seamens Grey Colour With Minimum 50 Microns., 84. Semi Folar Cots With Iv Pole And .D - Adult Steel Sheet Cotsize-78Lx36Wx24H, 1 ¼ Dia 14 Swg Tubular Head And Leg Bows Erw Tu.. The Head Bow And Leg Bows Are 42 And 36 Height Respectively. Head And Leg Bows . . 14 Gauge, 1 Dia Erw Cross Bar And ½ Dia 16 Gauge Erw Three Vertical Support Bars. Top Sheet 16 Swg Crca Sheet, Double Press .Nt Uniformly On All The Four Sides, 2 Vertically And ¾ Further Inside. A 6 Broad X 2 Deep Full Length 16 Gauge Square Cross Section Rib . . Reinforced To The Top Sheet 2 Nos. M.S. Gages Using 10 Swg, 4 Broad X 6 Length To . Welded On Each Side Of The Bows For Fixing The Cot Top Steel Sheet To The Frame By Using 8 Nos. Zinc Plated ½ Nuts And Bolts With Mosquito Net Poles To . Provided On The Side Of The Bows. Epoxy Powder Coated With Seamens Gray Colour With 50 Microns Minimum Coating.With Iv Infusion Stand-10, 85. Single Mobile Led Light Lamp, Examination, Wall Mounted Led Examination Light With Spring-Arm Colour Temperature Approx. 4.000 K Light Intensity Approx. 5.000 Lux At 500 Mm Wall Mounted, 86. Spiro Meter Hand-Held Equipment For Checking Lung Conditions With Usb / Pc Conectivity. . Connect It To Your Pc. Print-Outs Can . Taken By Attaching Any Printer Main Features: Forced Vital Capacity (Fvc), Forced Expired Volume In One Second (Fev1), The Ratio Of Fev1 And Fvc (Fev1%), Peak Expiratory Flow (Pef), 25% Flow Of The Fvc (Fef25), 75% Flow Of The Fvc(Fef75) And Average Flow .Tween 25% And 75% Of The Fvc (Fef2575) . . Measured. The Results Condition Can . Shown As Ratio Of The Measured Value And The Predicted Value. Flow Rate-Volume Chart, Volume-Time Chart Display.Data Memory,Delete, Upoad And Review. Trend Chart Display. Scaling(Calibration). Information Prompts When Volume Or Flow Goes .Yond The Limits. Automatic Power Off When There Is No Operation In One Minute. Rechargeable Lithium Battery And With Charging Tips. Battery Power Display, 87. Stethoscope Patient Friendly Non-Chill Rim Solid Stainless Steel / Anodized Aluminium Chest Piece Frame . . Stainless Steel Excellent Acoustic Diaphragm And Comfortably Fit With Soft Sealing Ear Tips Anatomically Correct Headset And Comfortably Angled Single Lumen Tubing In A Variety Of Popular Colours Y Pvc Tubing, 88. Streak Retinoscope Halogen Lamp Or Led Lampexternal Focusing Sleeve- Unique Planetary Gear System Which Allows For Easy Adjustment No Matter What Size Hand Or How Instruments Is Held.Continuous 360Deg Rotation.. Maintain The Same Plane Of Focus During Rotation.Dust- Free Optics Housings And Glass Cover On The Front Keep The Instrument Cleaner Longer.Crossed Linear Polarizing Filter Which Reduces Glare From Lenses Allowing Retinoscopy To . Performed Closer To The Axis Of The Correcting Lenses.Fixation Cards Must Provide Cards That Easily Attach To Increase The Ease With Which Dynamic Retinoscopy Is Performed. Optics Glare And Shadows . . Eliminated For A Clearer And More Precise View.Interchangeability By Simple Changing The Lamp, The Streak Retinoscope . . Converted To A Spot Retinoscope, 89. Suction Apparatus Technical Specificationsvolt- 230 Vacrating Of Motor- Continuoussuction Bottle Capacity- 2 X 2000 Ml Minimum (With Safety Valve)Guage- 0 To760 Mm Hgpump- Oil Lubricates Rotary Pumpsuction Tubings- Id 7 Mm, 5M Long And Non-Collapsible, 90. Suction Apparatus(Abs Panel) Suction Apparatus Ac / D.C And Manual1 . . Less Than Or Equal To 5Kg2 Canister Double Jarcapacity Minimum 1000 Ml Overflow Protection Mechanism Bacteria Filter Auto Clavable Spare Canister Polycarbonate Or Abs Plastic3 Vacuum Range: 3.1 Minimum Not More Than 50 Mmhg3.2 Maximum Not Less Than 500 And Not More Than 600 Mm Of Hg 3.3 Desirable To . Vacuum Range Indicators For Pediatric Flow Rate: 4.1 25 To 30L/Min Noise Level: Not More Than 60Db Power: . Run On Ac (120 To 240 V; 50/60Hz) And Dc (12V) Suction Tubing . . Compatible To . Attached To Yankauer Catheter, 91. Syringe Pump . . Easy To Use And Nurse Friendly. . . Automatic Syringe Size And Model Detection. . Large Format Lcd/Tft Display.. . A Minimum Flow Rate Range From 0.1 1200 Ml/Hr For 50Ml Syringe, 0.1 100 Ml/Hr For 20Ml Syringe And 0.1 60 Ml/Hr For 10Ml Syringe. Syringe Range From 20-50/60 Ml.. . A Flow Rate Accuracy Of Plus Or Minus2% . . A Bolus Rate Up To 1000Ml/Hr For 50 Ml Syringe. . . Automatic And Manual Bolus. . . At Least 3 Levels Of Programmable Occlusion Pressure.10.. . Automatic Bolus Reduction System To Avoid Accidental Bolus Delivery After Occlusion Incident.. A Rechargeable Battery With Back Up Time Of Minimum 3 Hours. Pump Must Triger Following Alarms With Visual Indication:-Occlusion Pressure Alarm Kvo Or 3 Min Pre- Alarm Syringe Empty And Volume Infused Alarm Internal Malfunction And Battery Charge Low Alarm Syringe Disengaged And Incorrectly Placed Alarm Alarm Loudness Control.No Mains Line Disconnected (Rapid Pressure Drop). Work With Input 200 To 240Vac 50 Hz Supply, 92. Thermometer (As Per Standard Specification), 93. Three 3 Step Slit Lamp Ans Tonometer Magnification Selection 3 Steps By Rotation Drum Magnification 10X, 16X, 25X Eyepiece 12,5X Diopter Adjustment Minus 5D To Plus 3Dtotal Magnification (Field Of View) 10X (22.5 Mm) / 15.98X (14.1 Mm)/ 25.53X (Dia 8.8 Mm)Illumination Led Lamp Slit Width Continuous From 0 To 14 Mm Slit Length Continuous From 1 To 14 Mm Aperture Continuous From 1 To 14 Mm, Dia 0.3, 1,5,10, 14Mm Slit Angle 0 Deg To 180 Degfilter Blue, Red Free Light Source Led Power Input (Primary) Ac 100 To 240V 50 To 60 Hz Power Consumption 40Va Mount Motorized Table, 94. Tongue Depresser (As Per Standard Specification), 95. Tuning Fork (As Per Standard Specification), 96. Ultra Sound With Color Doppler And Ecospecification For Portable Ultrasound Scanner For Er With Gynec Capability 3 Pro.S System Shall Provide All Digital Broadband .Amforming With Maximum Display Depth Shall . At Least 30 Cm. The System . . Capable Of Supporting Extreme Resolution Adaptive Image Processing Technique That Performs Analysis At The Pixel Level Eliminating Speckle Noise Artifact And Dynamically Enhancing Tissue Textures, Margins And Borders. The System . . Minimum 60000 Digitally Processed Channels Per Image Frame.. Support Broadband Phased Array, Convex, Linear And Tvs Transducers. . Capable Of Supporting Adaptive Image Processing Technique That Performs Analysis At The Pixel Level Eliminating Speckle Noise Artifact And Dynamically Enhance Tissue Textures, Margins And Borders. Specify The Technology.. Capable Of Supporting Compound Imaging Using Computed .Am Steering Technology. Specify The Technology. The System . . Free Hand 3D With Normal Pro.S And It . . Upgradable For 4D Imaging And Stic For Fetal Echo When Purchased With . The Machine . . Digitally Controlled, 19 Inch Flat Panel Monitor With Tilt And Swivel Facility. It . . Slide Pot Tgc And Lgc Gain Controls With Pre Defined Curves. Support Tissue Harmonic Imaging In Phased Array, Linear Array Convex Array And Volume Array Transducers.The System . . In Built Image Management System With At Least 300 Gb Hdd, Cd Writing Facility And Direct Paper Printout Of Images. 2D, Cw, Pw, Color Doppler, Thi, Color Power Doppler, M Mode, Pulse Inversion Harmonic Technology. The Machine Must . Anatomical M Mode, Automatic Doppler Analysis, Intelligent 2D Scan Facility, Intelligent Doppler Scan Facility, An Acquisition Frame Rate In 2D Of Atleast 1000 Frames/Second. Acquisition Frame Rate . . Clearly Mentioned In The Technical Quote. System . . A Very High Dynamic Range Of At Least 250 Db Or Morethetrapezoidal/Extended Imaging . . Available As Standard In The Machine. Panoramic Imaging . Also . Available.Following Transducers And Accessorizes To . Quoted As Standard: 2 To 5Mhz (Plus Or Minus 1 Mhz) Broadband Curved Array Transducer 5 To 9Mhz (Plus Or Minus 1Mhz) Broadband Curved Array Transducer For Transvaginal Application With Minimum 180 Deg Fov Or More. 3 To12 Mhz Broadband Linear Array Transducer Along (Optional) 2 To 5Mhz (Plus Or Minus 1 Mhz) Curved Array 4D Volume Transducer (Optional) Sony Thermal B/W Printer, 97. Urine Analyser Large Lcd Touch Screen Is Convenient For Users Operation. Builtin Thermal Printer Can Print Results Automatically. Environmentally Friendly Used Strip Collection And Disposal System. 4Wavelength Cold Light Source Ensures The Results Accuracy. 514 Samples Per Hour.Up To 14 Test Parameters Which Are Optional. 2000 Result Data Memory Is Convenient For Review.Technical Specifications: Test Parameters : Urobilinogen, Billirubin,Ketones, Blood, Protein, Nitrite, Leukocytes, Glucose, Specific Gravity,Ph,As Corbic Acid And (Microalb)Test Wavelength 525Nm,572Nm,610Nm,660Nm Test Principle: Photoelectric Colorimetry.Suitable Strips:Uts 8 10,11 And 11Ma (Micro Albumin) Strips Test Throughput: 514Strips/Hdata Memory:2000 Patient Results And 50 Q.C Resultscomputer Interface: Rs-231 Ports, Parallel Printer Interface. Display: 5.7Inches Lcdpower Supply: 100 To 240Vac ,50Hz/60Hz, 98. Vaccum Extractor Standard Features: Housing: Abs Plastic Moulded Capacity: 600 Mm Hg Plus Or Minus 10 , 12 Ltrs/ Min Pump Type: Piston Pump Jars: 1 X 1 Ltr Polycarbonate Jar Filter: Bacterial Filter Autoclavable/Reusable Tubing: 8 Mm Id X 2 Mtr. (Pvc) Vacuum Gauge: 5 Cm Dia 0 To 760 Mm Hg Calibration. Power: 220 V Ac, 50 / 60 Hz, 90Watt (110V On Request) Noise Level: 55 Db A Plus Or Minus 3 Dimension And Weight: 30 X 14 X 33 Cms, 4.5 Kg Overflow Safety: Mechanical Venteuse Cup: Silicone 50, 60 And 70Mm : Minimizes Risk Of Trauma And Cephalohematoma Of Fetal Cranium, 99. Technical Specifications Ventilator (Neonatal And Pediatric) Technical Characteristics (Specific To This Type Of Device) Facility For Invasive And Non Invasive Ventilation. Microprocessor Control Suitable For Neonatal And Pediatric Ventilation;Modes Of Ventilation Equipped With Newer Modes Of Ventilation: 3.1) Assist/ Control 3.2) Volume Control 3.3) Pressure Control 3.4) Pressure Support 3.5) Simv With Pressure Support (Pressure And Volume Control)3.6) Peep 3.7) Inverse Ratio Ventilation 3.8) Noninvasive Ventilation Bipap, Cpap 3.9) Apnea Ventilation, User Selectable, Volume And Pressure Control; Built In Color Screen Tft/Lcd Display Of Minimum 8 (Inch) For Display Of Waveforms 6.1) Airway Pressure (Peak And Mean) 6.2) Tidal Volume (Inspired And Expired) 6.3) Minute Volume (Inspired And Expired) 6.4) Respiratory Mechanics 6.5) Spontaneous Minute Volume 6.6) Total Frequency 6.7) Fio2 Dynamic 6.8) Intrinsic Peep 6.9) Plateau Pressure 6.10)Resistanceand Compliance 6.11)Use Selector Alarms For All Measured And Monitored Parameters 6.12)Occlusion Pressure 6.13)Pressure Flow And Volume Curves; Automatic Compliance And Leakage Compensation For Circuit And Et . . Facility Of Log Book, For Events And Alarms With Date And Time;. . Following Setting; 9.1) Tidal Volume (Minimum 2Ml, Maximum Up To 2000Ml); Pre Set Range For Both Neo Natal And Pediatric Modes To . Provided 9.2) Inspiratory Pressure (Up To 60Cm Of H2o); 9.3) Respiratory Rate 1 To 80 Bpm; 9.4) Apnea Back Up Rate; 9.5) Cpap/Peep; 9.6) Pressure Support; 9.7) Fio2 Setting Range .Tween 21% And 100%; 9.8) Pause Time; 9.9) Pressure/Flow Trigger; 9.10)Inspiratory Flow Up To 120 Lpm; Alarm Volume Min. 65Db Mobility: Trolley Type Power Requirements: Input Voltage 220 Vac, 50Hz; Full Face Mask 5 Nos Each Of 0,1, 2And 3 Nasal Cannula For Neonates 5 Nosreusable Breathing Circuit Of Silicone Material (5Nos), Disposable Breathing Circuit (50No.S) Air And Oxygen Hose 1 Each Catheter Mount, 100. Vortex Mixer Vortex Mixer 2800 Rpm An Extremely Sturdy And Reliable Unit Ideal For Extended Use In Research And Clinical Labs. With 3 Attachments For Shaking Tu.S, Flasks And Micro Centrifuge With Speed Regulator And Switch For Constant On And Touch On. Heavy Metal Base And Rub.R Feet Prevents Movement Of The Shaker During Use. Maximum Speed: 3000 Rpm, 101. Water Bath 12 Holes Water Bath 12 Holes . Double Wall Electrical . An Excellent Water Bath For Serological Studies In Labs. . Fully Stainless Steel Construction, Including Bottom, . Gmp Standard And Total Rust Proof. Compact Design And Superior Temperature Control Are Some Of The Plus Points Of This Unit. . Optional Gabled Lid Of Stainless Steel, Specially Designed So That The Condensate Drips On Sides. Digital Controller Cum Indicator - 1Degc Resolution. Easy To Set And Use - Direct Digital Setting And Readout. Temperature Range: Ambient + 5 To 65Degc, 102. Weighing Scale General Use Clinical Purpose To Measure Body Mass Of The Neonateused By Clinical Department/ Ward Nicu/Sncu Overview Of Functional Requirements Table Top, Light And Portable.Built In Rechargeablebattery.Easy To Clean Baby Tray(Acrylic). Zero Weight Adjustment Facility. Quick, Clear Digital Eadouts. Measurement Doesnot Change Withpositiono Fbabyonthe Pan. Provision Tomeasure The Heigh Tof The Baby Initslaying Position. Accuracy: 5G, Resolution: 1G , Limit: 10Gm To 15Kg.Settings Autosettingto 0.00Onceathe Machine Is Switched On Or When No External Weighthas.Enputon.Users Interface Lcd Display. Power Requirements 230 V Ac, 103. Weighing Balance (Analytical And Electronic) (As Per Standard Specification), 104. Wheel Chair Floor To Seat Height:650 Mm To 720 Mm.Overall Size Width:1000 Mm To 1100 Mm. Length 910 Mm To 950 Mm. Height 480 Mm To 510 Mm. Design: 1Inch Diameter 16 Swg Erw Tubular Frame Fitted With Metal Seat And Back. Adjustable Horizontal Aluminium Foot Rest 90Deg - 120Deg With Tread Flats. Half Round Wooden Hand Rest With 1Inch Cushion. Solid Rub.R Tyre Wheels 24Inch X 1 W Fitted With Self Propelling Hoops And Brake Arrangement. 8Inch Diameter Swivelling Castors In Front. Full Length Axle . . Provided To Fix The Rickshaw Wheel. Epoxy Powder Coated With Seamens Grey Colour With Minimum 50 Microns, 105. X-Ray View Box Technical Specification For Led Film X-Ray View Box .Ultra-Thin X Ray Film Illuminator Using Light A Thickness Of 29 Mm Suitable For Viewing 14X17 Filmthe Led Light Must . A Life Span Of More Than 1,00,000 Hours. Easy Insertion And Removal Of The Film Homogeneous Illumination More Than 95% And Maximum Intensity Of Over 10,000 Lux. . An On-Off Switch Along With Digital Feather Touch Dimmer And A Button To Set The Intensity 8. It . . Fully Electronic Continuous Brightness Control, With Adjustment Range Of Approximately 90%. . Directly Connectable To Power Supply Without Any External Adapter. Flicker Free High Frequency Light For Reduction Of Eye Strain. . External Fuses For Protection Against Power Surge.10 Step Digital Dimmer Facility With Step Up/Step Down Intensity Of 400 Luxautomatic Film Sensor Facility To Switch On Only The Section Where The Film Needs To . Viewed,