| 1 | 1 | Labour for attending GI pipe 15 mm to 40 mm dia pipe line complaints (break downs) upto G+3 floor, terrace and plane area including cutting and threading of pipes as per requirement of site.Note: GI Pipe and fittings shall be measured and paid separately under relevent items.\n | | 150 | Job |
|---|
| 2 | 2 | Labour for attending GI pipe 50mm to 80 mm dia pipe line break downs (plain area) including cutting threading of pipes as per site requirement.\nNote: GI Pipe and fittings shall be measured and paid separately under relevent items \n | | 80 | Job |
|---|
| 3 | 3 | Labour for attending GI pipe 50mm to 80 mm dia pipe line line complaints (break downs) in multi storage building upto G+9 floor including cutting and threading of pipes as per requirement of site including necessary scaffolding and safety measures.\nNote: GI Pipe and fittings shall be measured and paid separately under relevent items | | 10 | Job |
|---|
| 4 | 4 | Supply only GI tubing medium grade, galvanised of following sizes. Make: TATA/Zindal \nNote: The Quoted rate shall be deemed to include repairs and fittings and fixtures. | | | |
|---|
| 5 | 4.01 | 15 mm bore | | 25 | RM |
|---|
| 6 | 4.02 | 20 mm bore | | 25 | RM |
|---|
| 7 | 4.03 | 25 mm bore | | 50 | RM |
|---|
| 8 | 4.04 | 40 mm bore | | 40 | RM |
|---|
| 9 | 4.05 | 50 mm bore | | 100 | RM |
|---|
| 10 | 4.06 | 80 mm bore | | 100 | RM |
|---|
| 11 | 5 | Supply and fix gun-metal gate valves, with iron wheel head, screwed both ends of size 25 mm dia. Make: Leader/Zoloto | | 20 | Each |
|---|
| 12 | 6 | Supply and fix gun-metal gate valves, with iron wheel head, screwed both ends of size 40 mm dia. Make: Leader/Zoloto | | 4 | Each |
|---|
| 13 | 7 | Supply and fix gun-metal gate valves, with iron wheel head, screwed both ends of size 50 mm dia. Make: Leader/Zoloto | | 25 | Each |
|---|
| 14 | 8 | Supply and fix gun-metal gate valves, with iron wheel head, screwed both ends of size 80 mm dia. Make: Leader/Zoloto | | 15 | Each |
|---|
| 15 | 9 | Supply and fix GI tubes 20mm bore, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laying in floors including taking down the existing GI pipes. | | 50 | RM |
|---|
| 16 | 10 | Supply and fix GI tubes 25mm bore, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laying in floors including taking down the existing GI pipes. | | 175 | RM |
|---|
| 17 | 11 | Supply and fix GI tubes 40mm bore, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laying in floors including taking down the existing GI pipes. | | 50 | RM |
|---|
| 18 | 12 | Supply and fix GI tubes 50mm bore, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laying in floors including taking down the existing GI pipes. | | 200 | RM |
|---|
| 19 | 13 | Supply and fix GI tubes 80mm bore, medium grade, galvanised with all fittings and fixed complete to walls and ceilings or laying in floors including taking down the existing GI pipes. | | 205 | RM |
|---|
| 20 | 14 | M&L for cement concrete PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in including necessary form work. | | 2 | Cum |
|---|
| 21 | 15 | M&L for masonary valve chember of size 600x600x600 mm (Internal dimensions) including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15mm thick in cement mortar 1:4, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping, 50x50x6mm mild steel angle iron, 5 mm thick mild steel plate cover complete with locking arrangement painting steel and iron surfaces with synthetic enamel paint two coats aover a coat of zinc chrome primer compete all as specified. | | 4 | JOB |
|---|
| 22 | 16 | M&L for masonary valve chember of size 900x900x900 mm (Internal dimensions) including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15mm thick in cement mortar 1:4, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping, 50x50x6mm mild steel angle iron, 5 mm thick mild steel plate cover complete with locking arrangement painting steel and iron surfaces with synthetic enamel paint two coats aover a coat of zinc chrome primer compete all as specified. | | 4 | JOB |
|---|
| 23 | 17 | M&L for masonary valve chember of size 1200x1200x1200 mm (Internal dimensions) including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 foundation, brick work in cement mortar 1:6, plastering internal and external surface 15mm thick in cement mortar 1:4, PCC 1:3:6 type C1 (using 20mm graded stone aggregate) coping, 50x50x6mm mild steel angle iron, 5 mm thick mild steel plate cover complete with locking arrangement painting steel and iron surfaces with synthetic enamel paint two coats aover a coat of zinc chrome primer compete all as specified. | | 4 | JOB |
|---|
| 24 | 18 | Taking up or down steel tubing 15/20 mm bore and connections complete all as specified and directed by Engr-in-charge. | | 100 | RM |
|---|
| 25 | 19 | Taking up or down steel tubing 25 mm bore and connections complete all as specified and directed by Engr-in-charge. | | 295 | RM |
|---|
| 26 | 20 | Taking up or down steel tubing 40/50 mm bore and connections complete all as specified and directed by Engr-in-charge. | | 590 | RM |
|---|
| 27 | 21 | Taking up or down CI/MS/GI Pipe 80 mm bore and connections complete all as specified and directed by Engr-in-charge. | | 415 | RM |
|---|
| 28 | 22 | Supply & fix 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 & SDR 11 UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings with connected accessories of outer dia 32mm. | | 70 | RM |
|---|
| 29 | 23 | Supply & fix 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 & SDR 11 UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings with connected accessories of outer dia 40mm. | | 200 | RM |
|---|
| 30 | 24 | Supply & fix 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 & SDR 11 UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings with connected accessories of outer dia 50mm. | | 200 | RM |
|---|
| 31 | 25 | Supply & fix 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 & SDR 11 UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings with connected accessories of outer dia 63 mm. | | 240 | RM |
|---|
| 32 | 26 | Supply & fix 3 layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 & SDR 11 UV Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene including all random fittings with connected accessories of outer dia 90mm. | | 110 | RM |
|---|
| 33 | 27 | S & F PP-R gate valve (Brass Insert) of 25mm bore (outer dia) including taking down old gate valve complete all as specified and as directed . Make :- SFMC or equivalent | | 10 | Each |
|---|
| 34 | 28 | S & F PP-R gate valve (Brass Insert) of 32mm bore (outer dia) including taking down old gate valve complete all as specified and as directed . Make :- SFMC or equivalent | | 10 | Each |
|---|
| 35 | 29 | S & F PP-R gate valve (Brass Insert) of 40mm bore (outer dia) including taking down old gate valve complete all as specified and as directed . Make :- SFMC or equivalent | | 10 | Each |
|---|
| 36 | 30 | S & F PP-R gate valve (Brass Insert) of 50mm bore (outer dia) including taking down old gate valve complete all as specified and as directed . Make :- SFMC or equivalent | | 2 | Each |
|---|
| 37 | 31 | S & F PP-R gate valve (Brass Insert) of 63mm bore (outer dia) including taking down old gate valve complete all as specified and as directed . Make :- SFMC or equivalent | | 12 | Each |
|---|
| 38 | 32 | M&L for fabrication for errecting/ fixing mild steel (plain or chequered) plates square cut to made mild steel framed flash mixture for clarifier bridge of as existing with out any altermates conforming to Fe410W (Gde E-250) Quality A incl removing and plates all as directed by Engineer-in-Charge | | 1500 | kg |
|---|
| 39 | 33 | Excavation in trenches n.exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out in soft / loose soil for foundation, pipe lines etc, | | 200 | Cum |
|---|
| 40 | 34 | PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) in bases / pedestals for pipe lines, mud stops or chamfered on edges and including demolition of existing PCC complete all as specified and directed by Engr-in-Charge. | | 2 | Cum |
|---|
| 41 | 35 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in hard/dense soil. | | 164 | Cum |
|---|
| 42 | 36 | Removing surplus excavated soil n. exc. 50 m and depositing where directed at a level n-exc 1.5 m above the starting point. | | 36 | Cum |
|---|
| 43 | 37 | M & L for preparation of bottom surface of filter bed backwash drain valve by grinding and cutting edges to provide smooth surface for jointing with the new rubber sheet of 6mm thick and fixing new SS nut & bolts complete. Note :- high density rubber sheet for pressure rating 10 Kg/sqcm | | 2 | Each Job |
|---|
| 44 | 38 | Supply and fabricate MS 40mm thickness rod with necessary fabrication work rolling transportation insertion of batten new MS plate 8 mm thickness necessary foundation work to place filter bed backwash drain valve commissioning and testing and arresting the water leakages from the bottom of filter bed & plainting the same rubber coated paint over a coat of primer complete. | | 4 | Each Job |
|---|
| 45 | 39 | M&L for cleaning inlet gallery pipes size 150mm and 300mm dia buried in ground by injecting high pressure air to the pipes by using heavy duty pneumatic diesel driven air compressor of 600 CFM capacity in each jack wells complete all as specified and directed by Engr-in -charge . | | 3 | Each Job |
|---|
| 46 | 40 | M &L for Cleaning off mud & sluge and bushes trees cutting at out side around the jack wells with under water divers complete all as specified and directed by Engr-in -charge . | | 3 | Each job |
|---|
| 47 | 41 | Labour only for attending break down of pipe line bursting / cracks and including cleaning / removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes, DI Collar / mechanical Joints etc as per site requirement, testing for leakages of lead joints, testing and necessary dewatering by using necessary dewatering pumps, JCB's, Cranes complete all as specified and directed by Engr-in-Charge, for the following sizes:- \nNote 1 :- The quoted rate is deemed to be include the following:-\n(i) Arrangement of suitable Pump sets for dewatering at the time of attending break down. (ii) Necessary labour/trade men for attending break down. (iii) Labour element required for Dismantling /fixing CI/DI/MS pipes, specials, fittings etc.\nNote 2 :- Earth work, Supply only (as for site , as per types , as per size) pipes, specials, fittings will be measured and paid seperately under relevant items. | | | |
|---|
| 48 | 41.01 | 100/80 mm bore DI/MS pipe | | 7 | Job |
|---|
| 49 | 41.02 | 150 mm bore DI/MS pipe | | 11 | Job |
|---|
| 50 | 41.03 | 200 mm bore DI/MS pipe | | 4 | Job |
|---|
| 51 | 41.04 | 300 mm bore DI/MS pipe | | 4 | Job |
|---|
| 52 | 41.05 | 400 mm bore DI/MS pipe | | 4 | Job |
|---|
| 53 | 42 | Supply only MS ERW pipe of 200mm dia, all as directed by Engr-in-charge. | | 24 | RM |
|---|
| 54 | 43 | Supply only MS ERW pipe of 150mm dia, all as directed by Engr-in-charge. | | 60 | RM |
|---|
| 55 | 44 | Supply only MS ERW pipe of 100mm dia, all as directed by Engr-in-charge. | | 30 | RM |
|---|
| 56 | 45 | Supply only MS ERW pipe of 80 mm dia, all as directed by Engr-in-charge. | | 80 | RM |
|---|
| 57 | 46 | Supply only DI K9 water supply pipe lines of size 400mm bore and including taking down old DI water mains with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and directed by Engineer-in-Charge. \nNOTE: (i) Earth work will be measured and paid seperately.\n(ii) Labour required for fixing of DI pipe rate is included in Sl. item No. BOQ. | | 6 | RM |
|---|
| 58 | 47 | All as per Sl. item No.46 above but for 300 mm bore | | 12 | RM |
|---|
| 59 | 48 | All as per Sl. item No.46 above but for 200 mm bore | | 24 | RM |
|---|
| 60 | 49 | All as per Sl. item No.46 above but for 150 mm bore | | 75 | RM |
|---|
| 61 | 50 | Supply and replace damaged/ defective/ unserviceable Fire brigade inlet connection \n4 way all as directed by Engr-in-charge | | 2 | Each |
|---|
| 62 | 51 | Supply and replace damaged/ defective/ unserviceable Fire brigade inlet connection \n2 way all as directed by Engr-in-charge. | | 4 | Each |
|---|
| 63 | 52 | Supply and replace damaged /defective /unserviceable fire hydrant landing valve type A (single head outlet) of 63 mm dia with new hydrant conforming to IS- 5290, SS material complete all as directed by Engr-in-charge. | | 4 | Each |
|---|
| 64 | 53 | Supply and replace damaged /defective /unserviceable fire hydrant landing valve type B (double head outlet), of 63 mm dia with new hydrant conforming to IS- 5290, SS material complete all as directed by Engr-in-charge. | | 2 | Each |
|---|
| 65 | 54 | Supply and replace damaged/ defective/ unserviceable ABS plastic 3/4\" shut off nozzle suitable for 19/20 mm hose all as directed. | | 4 | Each |
|---|
| 66 | 55 | Repair/servicing of fire hydrant landing valve type 'A/B' of 63 mm dia, including spindle thread maching, washers replacement, checknut, packing serving complete to arrest leakage and proper function of valve all as directed. | | 4 | Job |
|---|
| 67 | 56 | M&L for providing leak proof joints at MS flanges with hydrant washers and ruber gaskets 10 mm thick, bolts, nuts, washers for 100 /150 mm bore MS pipe complete all as specified and directed by Engineer - in - Charge. | | 4 | Job |
|---|
| 68 | 57 | All as per Sl. item No. 56 above but of 80 mm bore | | 2 | Job |
|---|
| 69 | 58 | Supply and replacement of Gun metal nozzle suitable for 63 mm bore hose complete all as directed by Engr-in-charge | | 10 | Each |
|---|
| 70 | 59 | Supply and replacement of 63 mm bore15 m long hose conforming to IS with male and female coupling complete all as specified and directed by Engineer - in - Charge.\n | | 3 | Each |
|---|
| 71 | 60 | Supply and replacement Hose box out door type made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed by Engineer - in - Charge. | | 4 | Job |
|---|
| 72 | 61 | Supply and replacement of 4 mm thick sheet glass for fire hose boxes of size 0.20 x 0.20 m complete all as specified and directed by Engineer - in - Charge. | | 10 | Each |
|---|
| 73 | 62 | Supply and fix hose reel of 20 mm dia and 30 mtr length conforming to IS-5132 including gun metal hose reel cap (shank) suitable for double hydrant control valve all as directed. | | 3 | Each |
|---|
| 74 | 63 | Supply and replacement of single hydrant stand post made of MS pipe of size 80 mm bore heavy grade, 1.50 m height with 90°, duck foot bend both end flanged and including welding if required to suit single fire hydrant valve and testing complete all as specified and directed by Engineer - in - Charge. | | 3 | Each |
|---|
| 75 | 64 | M&L for dismantling the pump portion which is coupled with electric motor/Alternator of 105 BHP to 173 BHP capacity by removing the coupling and foundation bolts etc.Carrying out the overhauling of the pumpset including replacement of unserviceble minor spares/ parts such as impeller nut,keys,lock washer, gasket and gland packing to arrest the leakages from pump and greasing etc. complete cleaning, painting and reassembling in position, testing and commissioning up to satisfaction level complete all as directed by Engr-in-charge. | | 2 | Job |
|---|
| 76 | 65 | All as per Item No. 64 above but 60 HP to 100 HP capacity complete all as directed by Engr-in-charge. | | 2 | Job |
|---|
| 77 | 66 | Supply and filling Engine oil 15 W 40 Grade Castrol CRB for topping up (including draining out old oil from Gen Set) complete all as specified and directed.\nMake : Servo/ Valvoline/ HPCL | | 50 | Litre |
|---|
| 78 | 67 | M&L for Repair and Calibration of turbo super charger suitable for DG set of capcity upto 100 KVA as per calibration procedure, norms and as per manufacturer's guide lines including replacement of turbo supply hoses, discharge hoses, clamps and de-scaling of turbo charger complete all as specified and directed. | | 2 | Job |
|---|
| 79 | 68 | All as per SL item No.67 above but DG set of capacity 125 KVA to 200 KVA | | 2 | Job |
|---|
| 80 | 69 | All as per SL item No.67 above but DG set of capacity 250 KVA to 500 KVA | | 2 | Job |
|---|
| 81 | 70 | M&L for descaling of radiator suitable for DG set of capcity upto 100 KVA by dismantling the upper and lower tank, cleaning the core pipes and components with cleaning chemicals, arresting the leaking core by brazing/ dummy with lead including cleaning of upper and lower tanks, replacing the upper and lower tank gaskets and required nuts, bolts, painting with one coat of synthetic enamel paint of approved colour, refixing the same including testing complete all as specified and directed. | | 2 | Job |
|---|
| 82 | 71 | All as per SL item No.70 above but DG set of capacity 125 KVA to 200 KVA | | 2 | Job |
|---|
| 83 | 72 | All as per SL item No.70 above but DG set of capacity 250 KVA to 500 KVA | | 2 | Job |
|---|
| 84 | 73 | Supply and replace Radiator water hose kit including necessary SS clamps suitable for DG set of capacity 12.5 to 40 KVA complete all as specified and directed. | | 1 | Set |
|---|
| 85 | 74 | All as per SL item No.73 above but DG set of capacity 50 KVA to 125 KVA | | 2 | Set |
|---|
| 86 | 75 | All as per SL item No.73 above but DG set of capacity 200 KVA to 500 KVA | | 2 | Set |
|---|
| 87 | 76 | Supply and replace copper battery terminals set of 2 complete all as specified and directed.\n | | 10 | Set |
|---|
| 88 | 77 | Supply and replace diesel hose kit including necessary SS clamps suitable for DG set of capacity 12.5 to 40 KVA complete all as specified and directed. | | 1 | Set |
|---|
| 89 | 78 | All as per SL item No.77 above but DG set of capacity 50 KVA to 125 KVA | | 2 | Set |
|---|
| 90 | 79 | All as per SL item No.77 above but DG set of capacity 200 KVA to 500 KVA | | 2 | Set |
|---|
| 91 | 80 | M&L for cleaning of diesel tank of DG set of capacity 12.5 to 62.5 KVA, replacement of diesel measurement scale including painting the tank with one coat of synthetic enamel paint complete all as specified and as directed | | 2 | Job |
|---|
| 92 | 81 | All as per SL item No.80 above but DG set of capacity 82.5 KVA to 200 KVA | | 2 | Job |
|---|
| 93 | 82 | All as per SL item No.80 above but DG set of capacity 250 KVA to 625 KVA | | 2 | Job |
|---|
| 94 | 83 | M&L for servicing of alternator of any make suitable for DG set of capcity upto 100 KVA by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed. | | 2 | Job |
|---|
| 95 | 84 | All as per SL item No.83 above but DG set of capacity 125 KVA to 200 KVA | | 2 | Job |
|---|
| 96 | 85 | All as per SL item No.83 above but DG set of capacity 250 KVA to 500 KVA | | 3 | Job |
|---|
| 97 | 86 | M & L for repairs and calibration of main fuel injection pumping system of Diesel Engine of any make connected to 40 KVA to 82.5 KVA DG Set by replacing necessary packing /pipe on engine manifolds, filter housing etc complete all as directed.\nNote:- Quoted rate is inclusive of spare parts as required. | | 2 | Job |
|---|
| 98 | 87 | All as per SL item No.86 above but 100 to 200 KVA DG set | | 2 | Job |
|---|
| 99 | 88 | All as per SL item No.86 above but 250 to 500 KVA DG set | | 2 | Job |
|---|
| 100 | 89 | Supply and replacement of Copper cable single core 16 Sqmm connected to the battery charging system of DG set complete all as directed. | | 60 | RM |
|---|
| 101 | 90 | Supply and replace Solenoid Valve of capacity 24 Volts connected to DG Set of any capacity complete all as directed by Engr-in-charge. | | 2 | Each |
|---|
| 102 | 91 | All as per Sl. item No.91 above but 12 Volts capacity | | 2 | Each |
|---|
| 103 | 92 | Repair to the self starter of capacity 24 Volts connected to DG Sets of capacity 12.5 to 100 KVA including replacement of defective winding etc complete all as directed by Engr -in Charge. | | 2 | Job |
|---|
| 104 | 93 | All as per Sl. item No.93 above but DG Sets of capacity 125 to 250 KVA | | 3 | Job |
|---|
| 105 | 94 | All as per Sl. item No.93 above but DG Sets of capacity 320 to 625 KVA | | 2 | Job |
|---|
| 106 | 95 | Repair to the self starter of capacity 12 Volts connected to DG Sets of capacity 12.5 to 100 KVA including replacement of defective winding etc complete all as directed by Engr -in Charge. | | 2 | Job |
|---|
| 107 | 96 | Repair to Dynamo of capacity 24 Volts connected to DG Sets of any capacity including replacement of defective spare parts and winding complete all as directed by Engr-in-charge. | | 2 | Job |
|---|
| 108 | 97 | All as per Sl. item No.96 above but 12 Volts capacity | | 3 | Job |
|---|
| 109 | 98 | Supply and fix fan belts suitable for DG Sets of capacity 50 to 100 KVA Capacity including removing the existing unserviceable one complete all as specified and as directed. | | 2 | Each |
|---|
| 110 | 99 | All as per Sl. item No.98 above but 320 KVA Capacity | | 2 | Each |
|---|
| 111 | 100 | All as per Sl. item No.98 above but 500 KVA Capacity | | 4 | Each |
|---|
| 112 | 101 | M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) inclusing taking out old unsv existing pole of any size. Note: Excavating & PCC work shall be measured and paid separtely under relevent item. | | 6 | Each |
|---|
| 113 | 102 | M&L for earthing complete with galvanised steel earth plate electrode size 60cmX60cmX6mm thick burried directly in ground (earth pit not less than 2.25mtrs) deep below ground level with top edge of the plate not less than 1.5mtrs below normal ground level connected to galvanised iron wire 4mm by means of bolts, nuts, checknuts and washers of GI steel all as shown in electric plate No-5 of SSR - 1991 connected to earthing test point as as specified or indicated including watering arrangement with PCC 1 : 3 : 6 type C1 Chamber , MS Funnel , RCC 1:2:4 type B1 , 50mm thick for earth pit cover with 6 Nos of 8 mm dia CTD bars etc, including necssary excavation in any type of soil, returning , filling in, removal of surplus soil to a distance not exceeded 50m including charcoal and salt complete all as specified or indicated and testing on completion\n Note : The quoted rate is inclusive of necessary Excavation, earth work , RCC Cover and earthing lead upto 7.5m. | | 6 | Each |
|---|
| 114 | 103 | Supply and laying XLPE FRLS cable, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 16 sqmm 4 core complete all as specified and as directed. | | 120 | RM |
|---|
| 115 | 104 | Supply and fixing in replacement LED street/building security light 150 W of New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver suitable for pole dia upto 40mm including GI pipe bracket made of 40mm dia pipe light grade of length not less than 1.2m bent to shape as required fixed with and including necessary MS clamps, bolts, nuts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old fittings complete all as specified and directed by the Engineer-in-Charge. [Make: Bajaj cat no 169820 /Surya Roshini / Philips / CG / Havells / Wipro / GE] | | 10 | Each |
|---|
| 116 | 105 | Supply, fix, testing and commissioning new 12 Volts, 180 AH In-built Battery charger including removing existing unserviceable one complete all as directed | | 4 | Each |
|---|
| 117 | 106 | Supply, fix, testing and commissioning new 24 Volts, 180 AH In-built Battery charger including removing existing unserviceable one complete all as directed | | 3 | Each |
|---|
| 118 | 107 | Repair to AMF panel of 40 to 82.5 KVA DG Set, by tracing out the defects and replacing unserviceable parts including control wiring complete all as specified and directed by Engr-in-charge. \nNote: Spares shall be measured and paid separately under relevent items of BOQ and labour element for fixing parts shall be deemed to be included in the quoted rate. | | 2 | Job |
|---|
| 119 | 108 | All as per item No.107 above but AMF panel of 100 to 200 KVA DG Set | | 2 | Job |
|---|
| 120 | 109 | All as per item No.107 above but AMF panel of 250 to 500 KVA DG Set | | 2 | Job |
|---|
| 121 | 110 | Supply, install, commissioning and testing Capacitor bank for 3 phase, 415 V & 50 Hz system of capacity 50 KVAR all as specified and directed by the Engineer-in-Charge | | 1 | Each |
|---|
| 122 | 111 | Supply, install, commissioning and testing Capacitor bank for 3 phase, 415 V & 50 Hz system of capacity 30 KVAR all as specified and directed by the Engineer-in-Charge | | 1 | Each |
|---|
| 123 | 112 | Supply, install, commissioning 3 phase, 415 V & 50 Hz system of capacity star delta starter for 50HP vertical pumpset with suitable contractor complete all as directed . | | 1 | Each |
|---|
| 124 | 113 | Supply, install, commissioning 3 phase, 415 V & 50 Hz system of capacity star delta starter for 40 HP vertical pumpset with suitable contractor complete all as directed . | | 1 | Each |
|---|
| 125 | 114 | Contactor MCX - 32 \nMake:- Cat No CS97019 of L&T or its equivalent in ABB, BCH, Siemens , C&S Electric Ltd, Schneider | | 2 | Each |
|---|
| 126 | 115 | Contactor MCX - 34 \nMake:- Cat No CS97022 of L&T or its equivalent in ABB, BCH, Siemens , C&S Electric Ltd, Schneider | | 2 | Each |
|---|