| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-11-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-12-2020 |
| Name of Work: REPAIR/MAINT OF CERTAIN SUMMER APPLIANCES AND CONNECTED WORKS AT BAIRAGARH AND REPAIR/REPLACEMENT AND MAINT OF STREET LIGHTS/ SECURITY LIGHTS AT BAIRAGARH AND SI LINES UNDER GE BHOPAL. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Note: This work comprises of (i) Repair/maint of certain Summer appliances at Bairagarh (ii) Repair/replacement and maint of Street lights / security lights at Bairagarh and (iii) Repair/replacement and maint of Street lights / security lights at SI Lines.\nThe qty of individual part shall not vary beyond deviation limit specified in tender. | |||
| 2 | 2 | REPAIR/MAINT OF CERTAIN SUMMER APPLIANCES AND CONNECTED WORKS AT BAIRAGARH | |||
| 3 | 3 | M&L for cleaning down complete body including fitting and fixtures of desert cooler of capacity 4000 / 5000 Cum per hours of any make including removal of all sludges, loose paint dust, dirt, etc and preparing the surface for painting and applying two coats of synthetic enamel paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank including rewriting of MES No. etc complete all as specified and as directed. | 200 | EACH JOB | |
| 4 | 4 | M&L for taking out fan motor single phase 230 Volts, 1400 RPM, 3 speed 1/8 HP from desert cooler and rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bushes and reassembling and fixing in position complete all as specified and as directed. | 70 | EACH JOB | |
| 5 | 5 | S&F in repairs front grill / louvers to desert cooler made out from 0.8 mm thick GI sheet suitable for 5000 /4000 Cum / hrs capacity desert cooler of any make complete all as specified and as directed.. | 60 | EACH | |
| 6 | 6 | S&F in repairs PVC flexible pipe 16 mm outer dia with bends for desert cooler complete with PVC elbow complete all as specified and as directed. | 200 | EACH JOB | |
| 7 | 7 | S&F in repairs selector switches three way, 230 Volts single phase of standard quality fixed in desert coolers complete all as specified and as directed. | 120 | EACH | |
| 8 | 8 | S&F in repairs wood pad (Set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers complete all as specified and as directed. | 200 | SET | |
| 9 | 9 | S&F in repairs desert cooler motor of three speed, ISI marked, 1400 RPM, single phase with ring, side legs, necessary bolts and nuts of capacity 1/8 HP complete all as specified and as directed. \n[Make : Usha/ C&G/ Khaithan or equivalent as approved by GE] | 100 | EACH | |
| 10 | 10 | S&F in repairs plug top three pin 5 Amps complete all as specified and as directed.\n[Make: - ANCHOR / LEADER or equivalent as approved by GE]\n | 50 | EACH | |
| 11 | 11 | S&F in repairs switch piano type, 250 volts, singe pole, one ways, 5 Amps, fixed in desert coolers complete all as specified and as directed. | 50 | EACH | |
| 12 | 12 | S&F in repairs PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including necessary connection fixed in desert coolers complete all as specified and as directed. | 300 | RM | |
| 13 | 13 | S&F in repairs capacitor 4 MFD for fan motor of desert cooler complete all as specified and as directed.\n[Make:-EPCOS / SYSCAP / ASIAN or equivalent as approved by GE]\n | 50 | EACH | |
| 14 | 14 | S&F body of 22 gauge suitable for coolers of capacity 5000 Cum / hour complete all as specified and as directed. | 30 | EACH | |
| 15 | 15 | S&F body of 22 gauge suitable for coolers of capacity 4000 Cum / hour complete all as specified and as directed. | 30 | EACH | |
| 16 | 16 | S&F in repairs side shutter (Set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 4000 Cum / hrs capacity desert cooler complete all as specified and as directed. | 30 | SET OF THREE | |
| 17 | 17 | S&F in repairs side shutter (Set of three) made out from 0.80 mm thick galvanised iron sheet suitable for 5000 Cum / hrs capacity desert cooler complete all as specified and as directed. | 30 | SET OF THREE | |
| 18 | 18 | S&F in repairs float valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for 15 mm bore iron pipe, weight not less than 142 grams / each complete all as specified and as directed. \n[Make: - PRAYAG/POLYTUFF or equivalent as approved by GE] | 30 | EACH | |
| 19 | 19 | S&F in repairs sumbesable pump 230 Volts, 1/60 HP, ISI Marked for desert cooler including pump support plate fabricated with 0.4 mm thick GI sheet with fixing screws, nuts and bolts complete all as specified and as directed. \n[Make : Khaitan/Polar/GEC or equivalent as approved by GE]\n | 200 | EACH | |
| 20 | 20 | S&F in repairs plastic fan blade powder coated for fan motor of desert cooler 20 inch sweep complete all as specified and as directed. | 60 | EACH | |
| 21 | 21 | S&F in repairs cast iron ring of cooler fan motor with clamps suitable for desert cooler complete with nuts & bolts complete all as specified and as directed. | 100 | EACH | |
| 22 | 22 | S&F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut / screws complete all as specified and as directed. | 70 | EACH | |
| 23 | 23 | S&F in repairs 15 mm size stop cock of PTMT in any colour screwed for iron pipe and weight not less than 90 gram per cock | 30 | EACH | |
| 24 | 24 | S&F in repairs water tank suitable for desert cooler of cap 5000/4000 cum/hour, fabricated with 1 mm thick mild steel galvanized iron sheet including gas welding at joint and testing for water tightness of apply one coat of red oxide primer complete all as specified and as directed. | 50 | EACH JOB | |
| 25 | 25 | M&L for preparation of old painted surface of 40/80 Ltr capacity water cooler, externally and internally including compressor chamber, motor and applying synthetic enamel paint with spray machine including writing MES No. etc. complete all as specified and as directed. | 7 | EACH JOB | |
| 26 | 26 | All as per BOQ serial item No. 25.00 above but for water cooler capacity 60/120 Ltrs complete all as specified and as directed. | 7 | EACH JOB | |
| 27 | 27 | All as per BOQ serial item No. 25.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and as directed. | 7 | EACH JOB | |
| 28 | 28 | M&L for removing the condenser fan motor from water cooler of 40/80 ltrs capacity, rewinding the same with super enameled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush, side rubber packing and re-fixing of motor in original position with washer nuts and bolts complete all as specified and directed | 10 | EACH JOB | |
| 29 | 29 | All as per BOQ serial item No. 28.00 above but for water cooler capacity 60/120 Ltrs complete all as specified and as directed. | 8 | EACH JOB | |
| 30 | 30 | All as per BOQ serial item No. 28.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and as directed. | 8 | EACH JOB | |
| 31 | 31 | S&F in repairs Plastic fan blade suitable for water cooler of capacity 40/80 Litres complete all as specified and as directed. | 10 | EACH | |
| 32 | 32 | S&F in repairs Plastic fan blade suitable for water cooler of capacity 60 / 120 Ltrs complete all as specified and as directed. | 10 | EACH | |
| 33 | 33 | S&F in repairs Plastic fan blade suitable for water cooler of capacity 150/150 Litrs complete all as specified and as directed. | 10 | EACH | |
| 34 | 34 | S&F in repairs 15 mm size water tap, cast copper alloy, chromium plated push type suitable for water cooler of any capacity complete all as specified and as directed. \n[MAKE:-JAINKO/GEM/SOMA/ SHAKTI/CORONET or equivalent as approved by GE]\n | 40 | EACH | |
| 35 | 35 | S&F in repairs starting capacitor 2.5 MFD, 80/100 suitable for water cooler of any capacity complete all as specified and as directed.\n[Make:-EPCOS / USHA / ASIAN or equivalent as approved by GE] | 50 | EACH | |
| 36 | 36 | S&F in repairs running capacitor 2.5/10 MFD suitable for water cooler of any capacity complete all as specified and as directed.\n[Make:-EPCOS / USHA / ASAIN or equivalent as approved by GE]\n | 50 | EACH | |
| 37 | 37 | S&F in repairs thermostat suitable for water cooler of any capacity complete all as specified and as directed. \n[Make: Danfoss / Indfoss or equivalent as approved by GE]\n | 20 | EACH | |
| 38 | 38 | S&F in repairs waste water adaptor PVC, 32 mm size suitable for water cooler of any cpacity complete all as specified and as directed. \n\n | 15 | EACH | |
| 39 | 39 | S&F in repairs relay with Over Load Protector suitable for 40 to 150 liters capacity water cooler complete all as specified and as directed. | 20 | EACH | |
| 40 | 40 | S&F in repairs PVC drain out pipe, heavy duty 32 / 40 mm dia, wall thickness 2 mm complete with fittings such as nipple, clips etc fixed to water coolers of any capacity complete all as specified and as directed. | 20 | RM | |
| 41 | 41 | S&F Steel water tubes, medium grade, ISI marked, galvanised, 15 mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.\n[MAKE: TATA/ SURYA/ JINDAL/ PRAKASH or equivalent as approved by GE] | 40 | RM | |
| 42 | 42 | Transporting refrigerator of any make and capacity from MES Store Yard/site to contactor’s workshop for carrying out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations/MES store yard after repairing complete all as specified and directed. \nNOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.\n | 6 | EACH JOB | |
| 43 | 43 | M&L for cutting and removing unserviceable freezer unit of refrigerator capacity 165 / 170 / 175 litres of any make, and S&F new freezer unit with door and chill tray including jointing, brazing, recharging of refrigerant gas and testing for smooth functioning complete all as specified and as directed. | 10 | EACH JOB | |
| 44 | 44 | All as per BOQ serial item No. 43.00 above but for refrigerator capacity 286/300/310 Ltrs complete all as specified and as directed. | 5 | EACH JOB | |
| 45 | 45 | M&L for preparation of external old painted surface of refrigerator of capacity 286 / 300 / 310 litres of any make, including denting of minor patches and applying one coat of Duco paint with spray machine including polishing complete all as specified and as directed. | 5 | EACH JOB | |
| 46 | 46 | S&F in repairs thermostat suitable for refrigerator 165 to 130 liters capacity complete all as specified and as directed.\n[Make: Danfoss / Indfoss or equivalent as approved by GE] | 20 | EACH | |
| 47 | 47 | M&L in repairs for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into and including PVC casing capping, ISI marked, inclusive of all fittings such as tees, bends, junction boxes, etc. 25mm width and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire complete all as specified and directed.\n[Make of Cable : V-MARC/ Plaza/ Havells/Polycab as approved by GE]\nNote :\n(i) Wiring to be done as per approved colour code in IE rule. \n(ii) Two runs of 4.0 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.\n | 200 | RM | |
| 48 | 48 | Removing the unserviceable compressor sealed unit of any make from water cooler capacity 60 / 120 liters after cutting copper tubing without any damage to existing parts and M&L for replacing compressor with reconditioned compressor of same make with erection of compressor on base with suitable capillary, filter, etc jointing of copper refrigerant pipe line, charging gas to required level, complete including cleaning of fins, leakage testing, etc including testing for smooth functioning complete all as specified and as directed.. | 7 | EACH JOB | |
| 49 | 49 | All as per BOQ serial item No. 48.00 above but for water cooler capacity 40/80 Ltrs complete all as specified and as directed. | 7 | EACH JOB | |
| 50 | 50 | All as per BOQ serial item No. 48.00 above but for water cooler capacity 150/150 Ltrs complete all as specified and as directed. | 7 | EACH JOB | |
| 51 | 51 | Removing the unserviceable compressor sealed unit of refrigerator of capacity 286 / 300 / 310 liters of any make and M&L for replacing the compressor with reconditioned compressor of same make & model complete, installing in original position with all accessories like relay with Over Load Protector, filter & recharging of refrigerant complete including testing for smooth functioning complete all as specified and as directed. | 6 | EACH JOB | |
| 52 | 52 | All as per BOQ serial item No. 51.00 above but for refrigerator capacity 165/175 Ltrs complete all as specified and as directed. | 6 | EACH JOB | |
| 53 | 53 | S&F in repairs condensing coil suitable for water cooler of capacity 150 / 150 liters complete all as specified and as directed. | 7 | EACH | |
| 54 | 54 | S&F in repairs condensing coil suitable for water cooler of capacity 60 / 120 liters complete all as specified and as directed. | 7 | EACH | |
| 55 | 55 | S&F in repairs condensing coil suitable for water cooler of capacity 40 / 80 liters complete all as specified and as directed. | 5 | EACH | |
| 56 | 56 | Supply only refrigerant gas R-22 for charging complete all as specified and as directed. | 2 | KG | |
| 57 | 57 | M&L for servicing of Deep freezer of capacity 265 / 320 / 492 ltrs of any make, checking / testing all parts for its serviceability, oiling / greasing of condenser motor including replacing bushes / rubber packing / gasket and insulating material and including repairing door and replacing handle, hinges, nut, bolts, washers etc, checking of refrigerant standing pressure and tapping of refrigerant up to the required level complete including testing for smooth functioning complete all as specified and as directed. | 15 | EACH JOB | |
| 58 | 58 | M&L for preparation of external old painted surface of Deep freezer of capacity 405 / 492 liters of any makes including denting of minor patches and applying one coat of Duco paint with spray machine complete all as specified and as directed. | 2 | EACH JOB | |
| 59 | 59 | Removing the unserviceable compressor sealed unit of Deep freezer of capacity 320 liters of any make and M&L for replacing the compressor with reconditioned compressor of the same make of model complete re-installing in original position withal accessories like relay with over load protector & recharging of refrigerant complete including testing for smooth functioning complete all as specified and as directed. | 3 | EACH JOB | |
| 60 | 60 | S&F in repairs condensing coil suitable for Deep freezer of capacity 325 Liters complete all as specified and as directed. | 5 | EACH JOB | |
| 61 | 61 | S&F in repairs single pole and neutral enclosure with two pin and earth, plug and socket, single phase, 240 V with & including 1 No single pole MCB, capacity 20 amps, `C` charactristic, breaking cap 10 KA and industial plug top complete all as specified and directed. \n[MAKE:-Legrand (Cat no. 607841) or equivalent in Siemens/ Schinder/L&T/ ABB/Havells]\n | 25 | EACH JOB | |
| 62 | 62 | S&F in repairs stand made of MS angle of size 60 x 60 x 5 mm by necessary cutting weding and grouting as required at site and applying one coat of red oxide primer below two coats of synthetic enamel paint complete all as specified and as directed. | 50 | KG | |
| 63 | 63 | M&L for finding out the leakage with the pressure test of the condenser or cooling coil of water cooler 150/150 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and as directed. | 6 | EACH JOB | |
| 64 | 64 | All as per BOQ serial item No. 63.00 above but for water cooler capacity 120/80 Ltrs complete all as specified and as directed. | 6 | EACH JOB | |
| 65 | 65 | All as per BOQ serial item No. 63.00 above but for water coolercapacity 60/40 Ltrs complete all as specified and as directed. | 6 | EACH JOB | |
| 66 | 66 | M&L for finding out the leakage with the pressure test of the condenser or cooling coil of Rerigerator of capacity 300/310 litres storage/cooling capacity and dismantling the same for repair, reassembling the same after repair the leakage point by brazing/soldering including charging the gas R-22/R-134 and testing the water cooler complete all as specified and as directed. | 5 | EACH JOB | |
| 67 | 67 | All as per BOQ serial item No. 66.00 above but for refrigerator capacity 165/170/175 Ltrs complete all as specified and as directed. | 5 | EACH JOB | |
| 68 | 68 | Removing defective window/Split type air conditioner of any make and capacity from various locations fixed on walls, windows, etc and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site complete all as specified and directed. \nNOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.\n | 24 | EACH JOB | |
| 69 | 69 | Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary / new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. \nNote:-\n(a) Sealed unit compressor shall be measured and paid separately as supply only\n(b) If any item required to made equipment functional like capillary tube, copper pipe, etc is deemed to be included in quoted unit rate. | 15 | EACH JOB | |
| 70 | 70 | Taking out window/split type Air conditioner of any make and capacity from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. \nNOTE:- All spares such as compressor, fan motor, relay, capacitor, over load, etc shall be measured and paid separately as supply only.\n | 40 | EACH JOB | |
| 71 | 71 | Taking out package type Air conditioner of any make and capacity 5 Ton from position and cleaning the cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner, checking of electrical connections and re-fixing the same at its original position and testing complete all as specified and directed. \nNOTE:- (i) Rewinding of bloewer motor, cooling tower motor, etc shall be measuredand paid seperately. (ii) All other spares required for making the plant serviceable shall be deemed to included in the quoted unit rate. | 2 | EACH JOB | |
| 72 | 72 | S&F in replacement power contactor (as per existing) for stater panel board of package type AC complete all as specified and directed. \n[Make :- L&T/ Legrand/ Seimens/ Schinider or equivalent as approved by GE] | 2 | EACH | |
| 73 | 73 | M&L for rewinding of stator of blower motor of package type AC with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed. | 1 | EACH JOB | |
| 74 | 74 | M&L for rewinding of motor of cooling tower of package type AC with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint and complete servicing of the cooling tower complete all as specified and directed. | 1 | EACH JOB | |
| 75 | 75 | Supply only the folowing items for AC complete all as specified and directed. \nNOTE:-\n(a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items.\n(b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. \n(c) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months for all such replacement. If any compressor is burnt during the guaranty period the same shall be replaced by contractor without taking any extra cost including supply & charging refrigerent gas.\n | |||
| 76 | 75.01 | New hermitically sealed / Rotary type compressor of Capacity 1.5 TR\nMake: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.\n | 8 | EACH | |
| 77 | 75.02 | New hermitically sealed / Rotary type compressor of Capacity 2.0 TR\nMake: Emerson /Tecumesh /Carrier /Hitachi / Blue Star or equivalent as approved by GE.\n | 7 | EACH | |
| 78 | 75.03 | FHP motor of capacity 1/5 to 1/18 HP, single phase, 920 RPM with starting and running capacitor suitable for window type AC. \nMake : AUE/Air master or equivalent as approved by GE.\n | 10 | EACH | |
| 79 | 75.04 | Starting capacitor 80-100 MFD /100-120 MFD /120-150 MFD. \nMake: Keltronor/Epcos as per recommanded by manufacturer or equivalent as approved by GE.\n\n | 15 | EACH | |
| 80 | 75.05 | Running Capacitor 45/50 MFD.\nMake : EPCOS or as per recommanded by manufacturer or equivalent as approved by GE.\n\n | 15 | EACH | |
| 81 | 75.06 | Starting relay suitable for 1.0 /1.5 /2.0 TR compressor Make: HI-tech/Classic or as per recommanded by manufacturer or equivalent as approved by GE.\n | 15 | EACH | |
| 82 | 75.07 | Rotary/Push type selector switch suitable for 1.5/2.0 TR window type AC. | 4 | EACH | |
| 83 | 75.08 | Thermostat suitable for window / Split type A/C\nMake : INDFOSS/Godrej or as per recommanded by manufacturer or equivalent as approved by GE.\n | 4 | EACH | |
| 84 | 75.09 | Cover outer of GI Sheet heavy duty with painted for window type AC of capacity 1.5 / 2.0 TR \n | 2 | EACH | |
| 85 | 75.1 | Front grill for window type AC of any model all as required at site. Make: LG/ Lancer/ Blue star/ Fedder Lloyed/ Carrier | 2 | EACH | |
| 86 | 75.11 | Condenser/cooling fan blade suitable for window type AC of any make & capacity.\n | 5 | EACH | |
| 87 | 75.12 | Blower fan Motor suitable for split AC of any capacity & make. | 5 | EACH | |
| 88 | 75.13 | Remote PCB for a split type AC of any capacity & make. | 2 | EACH | |
| 89 | 76 | M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920 RPM with super quality of copper wire of existing size with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as specified and directed. | 4 | EACH | |
| 90 | 77 | Charging of refrigerant gas R-22 in window / split type air conditioners 1.5 / 2.0 TR at site/contractor’s workshop including all necessary work such as cost of refrigerant, welding to refrigerant pipe line, copper pipe, etc and testing complete all as specified and directed. \n | 80 | KG | |
| 91 | 78 | M&L for preparation of steel surfaces, removing of minor dents, making good with putty and applying one coat of spray painting on window type Air conditioners complete internally and externally with suitable super enameled synthetic enamel paint of approved colour complete all as specified and directed. \n | 10 | EACH JOB | |
| 92 | 79 | Taking down unserviceable voltage stabilizer of capacity 0.5 KVA to 5 KVA from site or MES store and and transporting to MES/ contractor workshop to carry out necessary repair as mentioned in respective item including replacement of un-serviceable spares parts and re-fixing at various locations after repairing or depositing to MES store yard including testing on load at site complete all as specified and directed. \nNOTE:- \n(a) If the transformer is found burnt, the same shall be re-winded in the workshop of contractor as directed.\n(b) All spares such as relay, PCB, transformeer, etc shall be measured and paid separately as supply only.\n | 10 | EACH JOB | |
| 93 | 80 | Supply only the folowing items for voltage stablizers complete all as specified and directed. \nNOTE:-\n(a) The element of fixing is deemed to be included in respective Schedule ‘A’ Items.\n(b) If any item is not executed/consumed during the contract period the same shall be taken on ledger charge through Receipt Voucher if Required. \n | |||
| 94 | 80.01 | Main relay 24 Volts, 25 Amps make as per OEM | 5 | EACH | |
| 95 | 80.02 | Main Control circuit (PCB) | 4 | EACH | |
| 96 | 80.03 | Output terminal, 32 Amps | 5 | EACH | |
| 97 | 80.04 | Replacement of Censor Transformer make as per OEM | 5 | EACH | |
| 98 | 80.05 | Voltmeter make as per OEM | 4 | EACH | |
| 99 | 80.06 | Time delay 2-3 minutes, low voltage-180 volts AC and high voltage 260-Volt AC make as per OEM | 3 | EACH | |
| 100 | 81 | S&F in repairs single core PVC insulated FRLS cable 1100V unsheathed with stranded copper conductor of 2.5 sqmm nominal cross section area complete all as specified and directed. \n[Make: V-MARC/ Plaza/ Havells/Polycab as approved by GE]\n\n | 300 | RM | |
| 101 | 82 | S&F in repairs plug top three pin 15 Amps, 240V complete all as specified and as directed. \n[Make: - ANCHOR / LEADER or equivalent as approved by GE]\n | 20 | EACH | |
| 102 | 83 | S&F in repairs Industrial type three pin metal clad socket of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser complete all as specified and as directed.\n[MAKE:-Legrand/ Siemens/ Schinder/L&T/ ABB/Havells or equivalent as approved by GE]\n\n | 30 | EACH | |
| 103 | 84 | REPAIR/REPLACEMENT AND MAINT OF STREET LIGHTS/ SECURITY LIGHTS AT BAIRAGARH | |||
| 104 | 85 | Taking down defective 40/150/250/400 watt SV/MH street light fittings, security light, CFL/flourescent tube light fittings (ant type & size), LED light any type, through ladders, mounted on any typr of poles/bldgs (upto 13 mtr height) with bracket, disconnecting, testing all components, dismantling for replacemnt defective components such as choke, ignitors, holders, capacitors, lamps, driver, etc and providing suitable new PVC cable for internal wiring, including cleaning of cover, connection with supply and testing the light fitting after fixing of new components and then mounting to its original position and making the fitting functional complete all as specified and directed. \nNote : \n(i) No T &P will be issued by the Department. \n(ii) Spares parts such as choke, ignitor, lamp holder, cable, lamps, etc shall be paid and measured separately.\n(iii) Rates also include repairing of defective street light timers, fault in street light feeders, etc \n(iv) During period of currency of CA any fitting will be not considered for more than once for payment purpose. | 300 | EACH JOB | |
| 105 | 86 | Taking down defective 150/250/400 watt SV/MH/LED lamp type light fittings (aprox 6 to 9 Nos in each fitting), integral/ non integral type flood light fitting, aviation light, etc, any type, mounted on semi high mast pole 12 tp 20 mtr height fixed on brackets/round ring (cage), disconnecting, testing all components, dismantling for replacement of defective components such as choke, ignitors, holders, capacitors, etc and providing suitable new PVC cable for internal wiring, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional complete all as specified and directed. \nNote : \n(i) No T &P will be issued by the Department. \n(ii) Spares such as choke, ignitor, lamp holder, cable, lamps, etc shall be paid and measured separately.\n(iii) Rates also include repairing of defective street light timers, fault in street light feeders, etc \n(iv) During period of currency of CA any fitting will be not considered for more than once for payment purpose. | 6 | EACH JOB | |
| 106 | 87 | S&F in repairs 400 watt HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin, terminal block with tapping for 220/240 volt, 50 Hz complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 8 | EACH | |
| 107 | 88 | S&F in repairs 150 watt HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin, terminal block with tapping for 220/240 volt, 50 Hz complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS/LUKER as approved by GE.] | 12 | EACH | |
| 108 | 89 | S&F in repairs 400 watt MH lamp SE/DE tubular suitable for integral / non integral street/flood light luminairs complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS/LUKER as approved by GE.] | 20 | EACH | |
| 109 | 90 | S&F in repairs 150 watt MH lamp SE/DE tubular suitable for integral / non integral street/flood light luminairs complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS/LUKER as approved by GE.] | 40 | EACH | |
| 110 | 91 | S&F in repairs 150 watt HPSV/MH open construction electromagnetic ballast consisting of high quality silicon steel lamination, super enamelled copper wire, vacuum impriganated with white resin, terminal block with tapping for 220/240 volt, 50 Hz complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS/LUKER as approved by GE.] | 10 | EACH | |
| 111 | 92 | S&F in repairs electronic ballast 2 x 14 watt suitable for 14 Watt CFL/ FTL-T5 tube light fitting 240 V complete all as specified and directed.\nMake: Bajaj Cat Part No 530065 Regular electronic ballast 2 x 14 W having THD < 30 %, and PF > 0.95 OR Wipro Cat Part No. WBF90214 or equivelent in Philips/CG/Havells. | 10 | EACH | |
| 112 | 93 | S&F in repairs T5 lamp 1 x14 watt, sleek size T5 tube, 240 V, complete all as specified and directed.\nMake: Wipro or equivelent in Philips/CG/Havells. | 50 | EACH | |
| 113 | 94 | S&F in repairs electronic ignitors suitable for 150/250/400 watt SV/MH street light fitting 240V, 50 Hz suitable for 5 mtr striking distance complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS/LUKER as approved by GE.] | 40 | EACH | |
| 114 | 95 | S&F in repairs LED driver suitable for 25 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed.\n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 40 | EACH | |
| 115 | 96 | S&F in repairs LED driver suitable for 70 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 12 | EACH | |
| 116 | 97 | S&F in repairs LED driver suitable for 100 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 15 | EACH | |
| 117 | 98 | S&F in repairs LED driver suitable for 150 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 15 | EACH | |
| 118 | 99 | S&F in repairs LED tube lamp 20/21Watt (LED retrofit tube, T8 pattern, single side connection), 240V, PV > 0.90, colour Temp 6500 K, system luminious efficancy >100Lm/W to be fixed in existing or new batten including taking down of existing fitting and changing the wiring according to T8 LED retrofit lamp in existing T8 street light fitting (box type) with G13 lamp holder complete complete all as specified & directed. \n[Make: Bajaj/ Philips/Wipro/Crompton/Syska/Havells/Luker as approved by GE]. \n | 60 | EACH | |
| 119 | 100 | S&F cable PVC insulated and PVC multisheathed size 6 Sqmm twin core stranded aluminium conductor complete all as specified and directed .\nNote:- Conductor fitted on LT pole for street light in 1.5 to 2 mtr length. | 300 | RM | |
| 120 | 101 | S&F in repairs Street light brackets made out of GI tubing, light grade, 32 mm bore 1200mm long, bent to shape at 120 degree, fixed on pole by providing MS clamp made up of flat iron 40 x 5 mm including bolts, nuts and washer of suitable size incuding painting the bracket & clamp with two coats of aluminium paint over a coat of primer complete all as specified and directed. | 30 | EACH | |
| 121 | 102 | Taking down existing street light fitting any type and S&F Integral LED Street light luminaire of 25 W, comprising of pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses, LED street light luminaires with IP 65 protection and with all fixing arangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed. \n[MAKE: Wipro(Cat no. LR02-291-XXX-57-XX) or equivalent in Philips/ Crompton/Bajaj/Havells/LUKER as approved by GE.] | 20 | EACH | |
| 122 | 103 | Taking down existing street light fitting any type and S&F Integral LED Street light luminaire of 45 W, comprising of pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses, LED street light luminaires with IP 65 protection and with all fixing arangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed. \n[MAKE: Wipro(Cat no. LR02-501-XXX-57-XX) or equivalent in Philips/ Crompton/Bajaj/Havells/LUKER as approved by GE.] | 20 | EACH | |
| 123 | 104 | Taking down existing flood light fitting any type and S&F Integral LED flood light luminaire of 150 W with secondary optics made in pressure die cast housing & heat sink in aluminium extrusion with IP 66 protection with all fixing arangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed.\n[MAKE: Wipro(Cat no. LF20-192-060-57-G2) or equivalent in Philips/ Crompton/Bajaj/Havells/LUKER as approved by GE.] | 6 | EACH | |
| 124 | 105 | Taking down existing flood light fitting any type and S&F Integral LED flood light luminaire of 100 W with secondary optics made in pressure die cast housing & heat sink in aluminium extrusion with IP 66 protection with all fixing arangement, nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole, testing on completion, complete all as specified and directed. \n[MAKE: Wipro(Cat no. LF20-122-060-57-G2) or equivalent in Philips/ Crompton/Bajaj/Havells/LUKER as approved by GE.] | 6 | EACH | |
| 125 | 106 | S&F in repairs 3 Pole contactor of AC 3 rating 25 Amp, 3 Phase, 415 V as per IS 13947-4-1 suitable for nature time switch (Model- Swadeep 02) complete all as specified and directed. \n[MAKE: BCH/L&T/SCHNEIDER as approved by GE.] | 3 | EACH | |
| 126 | 107 | M&L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed. including necessary form work complete all as specified and directed. \n | 0.5 | CUM | |
| 127 | 108 | Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 25 sqmm, 3.5 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. \n[MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE] | 100 | RM | |
| 128 | 109 | Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 16 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. \n[MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE] | 100 | RM | |
| 129 | 110 | Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 10 sqmm, 2 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. \n[MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE] | 300 | RM | |
| 130 | 111 | M&L for Painting to the LT PCC poles with strips in alternate from bottom to top (up to 1.5 Mtrs) with three strips of black synthatic paint & two strips of fluorescent white paint through out the circumference of pole ( width of each strip shall be of 30 cm), including one coat of lime wash on PCC copping of pole and two coat of aluminium paint to channels, cross arm, clamps and pipesfixed/ mounted on pole after scraching out old paint, cleaning and making exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 20 cm dia yellow circle with number writting with black syenthic paint complete all as specified and directed. | 10 | EACH | |
| 131 | 112 | M&L for Painting of steel pole High mast Pole up to 13 mtr height with luminarie mounting ring with two coat of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking including one coat of lime wash on PCC copping of pole complete all as specified and directed. | 10 | EACH | |
| 132 | 113 | Taking down u/s automatic street light switch and Supply, fixing testing and comissioning, of automatic street light switch of capacity 5 KW in three phase, using Nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contractor, MCB and support terminals enclosed in pole/ wall mounted enclouser made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories all as specified and directed by EIC. Make:- KAKATIYA ENERGY SYSTEM LIMITED Model No. SWADEEP - 02EC5KW3P, The automatic switching unit shall comprising of following: \n(i) Contractor rating (AC3) 25Amp 4 Pole or 3 Nos 25Amp 1 Pole: Make : BCH/L&T/Schneider\n(ii) MCB 32Amps(SP),10 KA ,240 volts (SP 3Nos) Make : Scheinder/ Legrand/ L&T\n(iii) NATURESWITCH-01 Make: KAKATIYA ENERGY SYSTEM LIMITED or equivalent as approved by GE\n | 3 | EACH | |
| 133 | 114 | S&F MCCB, 200 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range 160-200 Amp including spreader terminals and phase barriers complete all as specified and directed.\nMake :- L&T (d - sine) Cat No. CM90642OONO or equivelent in Scheinder/ Legrand. | 1 | EACH | |
| 134 | 115 | S&F MCCB, 160 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range 125-160 Amp including spreader terminals and phase barriers, complete all as specified and directed.\nMake :- L&T (d - sine) Cat No. CM90642OOMO or equivelent in Scheinder/ Legrand. | 2 | EACH | |
| 135 | 116 | S&F MCCB, 100 Amp, 4 Pole, 25 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , with thermal release range 80-100 Amp including spreader terminals and phase barriers, complete all as specified and directed.\nMake :- L&T (d - sine) Cat No. CM90642OOLO or equivelent in Scheinder/ Legrand. | 2 | EACH | |
| 136 | 117 | M&L for providing ACSR overhead lines on existing LT PCC poles/steel tubular poles with aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete after dismentling and taking down old ACSR conductor of any size and make, complete all as specified and directed. | 1 | QTLS | |
| 137 | 118 | Cutting of bituminous road/PCC hard standing/road/floor for laying of GI pipe upto 80mm dia (trench not more than 0.3m x 0.3m) for passing of cable including making good the disturbed surfaces all as per existing complete all as specified and directed. \nNote:-GI pipe shall be measured & paid separately under relevant items of this schedule. | 10 | RM | |
| 138 | 119 | M&L for tightening and re stringing of existing ACSR over head conductor of any size/type on HT/LT over head line with the help of rope/line wise and tighting the conductor to permissiable sag with and including new aluminium tape/aluminium wire complete all as specified and as directed. (each conductor to be measured seperatly) | 350 | RM | |
| 139 | 120 | Dismantling of ACSR conductor of any type and size complete all as specified and directed. | 1 | QTLS | |
| 140 | 121 | S&F in repairs Analog time switch (FM series) all as per existing complete all as specified and directed. \n[MAKE: L&T (Model- GIC) /SCHENIDER/BCH as approved by GE.] | 4 | EACH | |
| 141 | 122 | Dismantling of LT insulator of any type any size complete all as specified and directed | 24 | EACH | |
| 142 | 123 | S&F pin type, porcelain, vitreous white/ brown insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150mm height, 150mm dia for 1100 volts grade complete all as specified and directed. | 12 | EACH | |
| 143 | 124 | S&F shackle type, porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps, washers, insulator bolts, washers and nuts; 75mm height, 90mm dia for 1100 volts grade complete all as specified and directed. | 12 | EACH | |
| 144 | 125 | Taking down existing old LED light fitting any type and deposited to AGE E/M office Fixing only in replacement LED light luminaire any type any size with all fixing arrangement, nut , bolt and washer connecting to electric system with 1.5 sqmm PVC Aluminium stranded conductor 2 core of required length from light fitting to street light control box on pole , testing and completion, complete all as specified and directed at site. \nNote:- Street light shall be issued under schedule\"B' free for fixing. | 90 | EACH | |
| 145 | 126 | M&L for servicing of stand alone solar LED light, 11 watt by making it functional by carrying out complete servicing, addition of distled water in battery, putting white jelly on battery terminal, checking of PCB, battery charging circuit and carrying out repairs in circuit complete all as specified and directed.\nNOTE:- Replacemnt of battery will be measured and paid seperately | 50 | EACH JOB | |
| 146 | 127 | COMMON ITEMS FOR REPAIR/REPLACEMENT AND MAINT OF STREET LIGHTS/ SECURITY LIGHTS AT BAIRAGARH AND SI LINES | |||
| 147 | 128 | Taking down defective 150/250/400 watt SV/MH/LED lamp type light fittings (aprox 6 to 9 Nos in each fitting), integral/ non integral type flood light fitting, aviation light, etc, any type, mounted on semi high mast pole upto 12 mtr height fixed on brackets/round ring (cage), disconnecting, testing all components, dismantling for replacement of defective components such as choke, ignitors, holders, capacitors, etc and providing suitable new PVC cable for internal wiring, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional complete all as specified and directed. \nNote : \n(i) No T &P will be issued by the Department. \n(ii) Spares such as choke, ignitor, lamp holder, cable, lamps, etc shall be paid and measured separately.\n(iii) Rates also include repairing of defective street light timers, fault in street light feeders, etc \n(iv) During period of currency of CA any fitting will be not considered for more than once for payment purpose. \n(Qty : Bairagarh - 8.00 ; SI Lines - 14.00) | 22 | EACH JOB | |
| 148 | 129 | S&F in repairs LED driver suitable for 45 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.]\n(Qty : Bairagarh - 40.00 ; SI Lines -21.00) | 61 | EACH | |
| 149 | 130 | M&L for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including filling at road cuttings or making pillars for supporting pipe including necessary form work complete all as specified and directed. \n(Qty : Bairagarh - 0.50 ; SI Lines - 1.00) | 1.5 | CUM | |
| 150 | 131 | Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, armoured, heavy duty cable with aluminium conductor of size 16 sqmm, 4 core, 1100 volts grade, laid in trenches, passing through pipes/ducts, etc including taking out old unserveciable cable, any type complete all as specified and directed. \n[MAKE:- POLYCAB /HAVELLS INDIA LTD/V-MARC as approved by GE]\n(Qty : Bairagarh - 100.00 ; SI Lines - 200.00) | 300 | RM | |
| 151 | 132 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft/loose soil complete all as specified and directed. \n(Qty : Bairagarh - 45.00 ; SI Lines - 40.00) | 85 | CUM | |
| 152 | 133 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. \n(Qty : Bairagarh - 15.00 ; SI Lines - 25.00) | 40 | CUM | |
| 153 | 134 | Removing excavated soil not exceeding 50m and depositing where directed. at a level not exceeding 1.5m above the starting point complete all as specified and directed. \n(Qty : Bairagarh - 30.00 ; SI Lines - 15.00) | 45 | CUM | |
| 154 | 135 | M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. \n[Note:-Compacted/punned thickness shall be measured & paid]\n(Qty : Bairagarh - 28.00 ; SI Lines - 12.00) | 40 | CUM | |
| 155 | 136 | Supplying and laying sub class 'B' bricks (modular) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.\n(Qty : Bairagarh - 2.50 ; SI Lines - 1.00) | 3.5 | Per 1000 Nos | |
| 156 | 137 | S&F 50mm GI tubing light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer including taking down old rusted pipe complete all as specified and directed. \n[MAKE:-TATA / JINDAL / PRAKASH / SWASTIK as approved by GE]\n(Qty : Bairagarh - 12.00 ; SI Lines - 30.00)\n | 42 | RM | |
| 157 | 138 | M&L for painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/street light with two coats of aluminium paint after scratching out old paint, cleaning the existing surface rust free, preparation of the surface including marking pole numbers in a 20 cm dia yellow circle with number writing with black synthetic paint & painting strips in alternate from bottom to top with three strips of black synthetic paint & two strips of white fluorescent paint (up to 1.5 mtr height) throughout the circumference of pole ( width of each strip shall be of 30 cm), including one coat of lime wash on PCC copping of pole complete all as specified and directed.\n(Qty : Bairagarh - 10.00 ; SI Lines - 100.00)\n | 110 | EACH | |
| 158 | 139 | Taking down u/s automatic street light switch and Supply , fixing testing and comissioning, of automatic street light switch of capacity 5KW in single phase, using Nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contractor, MCB and support terminals enclosed in pole/ wall mounted enclouser made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete acessories all as specified and directed.\nMake:- KAKATIYA ENERGY SYSTEM LIMITED Model No. SWADEEP - 02EC5KW1P, The automatic switching unit shall comprising of following: \n(i) Contractor rating (AC3) single phase 50-60 Amp : Make : BCH/L&T/Schneider\n(ii) MCB 63 Amps(SP),10 KA ,240 volts. Make : Schinder/ Legrand/ L&T\n(iii) NATURESWITCH-01 Make: KAKATIYA ENERGY SYSTEM LIMITED\n(Qty : Bairagarh - 5.00 ; SI Lines - 12.00)\n\n | 17 | EACH | |
| 159 | 140 | M&L for servicing of stand alone solar LED light, 18 watt by making it functional by carrying out complete servicing, addition of distled water in battery, putting white jelly on battery terminal, checking of PCB, battery charging circuit and carrying out repairs in circuit complete all as specified and directed.\nNOTE:- Replacemnt of battery will be measured and paid seperately.\n(Qty : Bairagarh - 40.00 ; SI Lines - 10.00)\n | 50 | EACH JOB | |
| 160 | 141 | S&F in replacement of Battery 12 volt, 100 Ah, maintenance free, with minimum 18 months warranty suiatble for solar LED lights complete all as specified and directed.\nMake:- Amron, Exide, Tata, as approved by GE.\n(Qty : Bairagarh - 46.00 ; SI Lines - 12.00)\n | 58 | EACH | |
| 161 | 142 | REPAIR/REPLACEMENT AND MAINT OF STREET LIGHTS/ SECURITY LIGHTS AT SI LINES | |||
| 162 | 143 | Taking down old defective /unservicable HPSV/MH street light fitting/ Led light fitting of any wattage for replacement with new fitting , including provision for new LED drivers for servicable LED fittings through ladder/motorised /manual system, mounted on pole/bldg, on bracket complete all as specified and directed.\nNote : (i) No T &P will be issued by the Department.\n(ii) While execution of work, contractor must be ensure proper safety precaution be followed.\n(iii) The cost for new LED drivers / new LED fittings will be measured and paid seperately under respective items. | 120 | EACH | |
| 163 | 144 | S&F in repair Integral LED Street light luminaire of 90W, comprising of epoxy powder coated housing, enclosed with glass cover in frame ,IP 66 protection and with all fixing arangement , nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core upto require length,on pole , testing and completion, complete all as specified and directed.\nMake: Havells CAT NO -ENDURAPEARLPLUSSL90WLED757P or equivelant in Bajaj . | 21 | EACH | |
| 164 | 145 | S&F in repair Integral LED High mast / flood light luminaire of 120W, comprising of epoxy powder coated housing, enclosed with glass cover in frame ,IP 66 protection and with all fixing arangement , nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core upto require length,on pole , testing and completion, complete all as specified and directed.\nMake: Havells CAT No :JETAIRISFLS120WLED757SYMLTG OR equivalent in Bajaj. | 14 | EACH | |
| 165 | 146 | S&F in repair Integral LED Street light luminaire of 45W, comprising of epoxy powder coated housing, enclosed with glass cover in frame ,IP 66 protection and with all fixing arangement , nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core upto require length,on pole , testing and completion, complete all as specified and directed\nMake: Havells CAT NO -ENDURAPEARLPLUSSL90WLED757P or equivelant in Bajaj . | 10 | EACH | |
| 166 | 147 | S&F in repair Integral LED Street light luminaire of 60W, comprising of epoxy powder coated housing, enclosed with glass cover in frame ,IP 66 protection and with all fixing arangement , nuts, bolts and washer connecting to electric system with 2.5 sqmm PVC Aluminium stranded conductor 2 core upto require length,on pole , testing and completion, complete all as specified and directed.\nMake: Havells CAT NO -ENDURAPEARLPLUSSL90WLED757P or equivelant in Bajaj . | 15 | EACH | |
| 167 | 148 | S&F in repairs LED driver suitable for 90 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 30 | EACH | |
| 168 | 149 | S&F in repairs LED driver suitable for 60 watt LED light (to suit as existing light fitting of any make) complete all as specified and directed. \n[MAKE: WIPRO/BAJAJ/CROMPTON/HAVELLS/PHILIPS as approved by GE.] | 23 | EACH | |
| 169 | 150 | S&F in repairs Coral post top lantern fitting 15 Watt , energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with complete accessories complete all as specified and directed.\nMake: Havells , Cat NO: CORALMINIPT15WLED75PSSYMTOPC or equivalent in Bajaj. | 30 | EACH | |
| 170 | 151 | S&F in repairs PVC insulated , fire resistant round sheathed copper conductor cable of size 2 core 6 sq mm conductor complete with accessories such as clamps, bolts to be fixed on wall / floor, complete all as specified and directed. \nMake : Havells or equivalent as approved by GE. | 196 | RM | |
| 171 | 152 | S&F in repairs of MCCB TPN 200 amps, 415 volts, 36Hz 25KA, complete all as specified and directed\nMake : Havells / Legrand / ABB / HPL / C & S/ as approved by GE. | 5 | EACH | |
| 172 | 153 | S&F in repairs of MCCB TPN 250 amps, 415 volts, 36Hz 35KA, complete all as specified and directed.\nMake : Havells / Legrand / ABB / HPL / C & S/ as approved by GE. | 5 | EACH | |
| 173 | 154 | Deduct schedule of credit (calculation will be done off line) Rs. 151444.00 |