Re E Tender For Procurement Of Consumable Items For Two Years From The Date Of Award Of Contract ( Aoc ) -1 ABSORBABLE GELATINE SPONGE 20cm x 7cm x .05cm 2 ABSORBABLE GELATINE SPONGE 07cm x 5cm x 1cm 3 ABSORBABLE GELATINE SPONGE 7cm x 5cm x 0.1cm 4 ABSORBABLE GELATINE SPONGE ANAL 0.3cm x 8cm 5 AMBU Bag (Resuscitation Bags)- 500ml Quantity Technical Specification: 1. Self inflating bag 2. Provided with closed ended reservoir with two valves 3.Face masks: 3 sizes: 00, 01 & 02: 2 of each size per bag making 2 set 4.Its fitted with safety valve set at 40 cm H2O, has an outlet for pressure monitoring 5.Bag should be made of sterilizable synthetic material like silicone 6.Patient valve should be well sealed, have minimum dead space and no forward or backward leaks 7.The bag should have an oxygen inlet which fits into the standard oxygen tubing both from a cylinder and central supply. 8.Reusable face masks should be transparent, fit the patient outlet of the bag easily and have minimum dead space. 9.The system should with stand washing scrubbing and autoclaving procedures, chemical sterilization. 6 Amplatzer extra stiff type guide wire. • Length should be 180 cm & 260cm. • Dia should be 0.038” & 0.035”. 7 ANTIBIOTIC TULLE DRESSING IMPREGNATED WITH WHITE PARAFFIN WAX 10 X 10 CM 8 Arterial Lines : Polyethylene/ Polyeurathene Arterial lines (SingleLumen 18G - Length-15CM/10CM/8CM/6CM/4CM) with Seldinger Technique 9 Arterial Lines : Polyethylene/ Polyeurathene Arterial lines (SingleLumen 22G - Length-15CM/10CM/8CM/6CM/4CM) with Seldinger Technique 10 Access guidewire - Nitinol core wire. Straight Tip with hydrophilic coating. Working Length : 450 cm, Outer Dia : 0.035 11 Adhesive (Copolymer) based Silk Tape, non-elastic tape with strong tensile strength, 1.25 cm (minimum.) X 9 m (minimum). 12 Adhesive (Copolymer) based Silk Tape, non-elastic tape with strong tensile strength, 2.50 cm (Minimum) x 9m (minimum) . 13 Adhesive (Copolymer) based Silk Tape, non-elastic tape with strong tensile strength, 5.00 cm (Minimum) x 9m (minimum) . 14 Adhesive, sterilized umbilical cotton tape width 3 mm , length 75 cm 15 Adhesive, Transparent film Dressing with window frame delivery style, Waterproof, sterile, Bacterial and viral barrier, high adhesive but skin friendly with easy stretch and release technique for removal (14cm - 16 cm X 19cm - 21cm) 16 Bacteria Viral Filters for ventilator Adult size 17 Bacteria Viral Filters for ventilator Paediatric size 18 BLEACHED BANDAGE CLOTH 19 BLEACHED GAUZE CLOTH 20 Blood Pressure Equipment, Anaroid Type (Sphygmomanometer, Aneroid Type) 21 Bone cement 40 gm Pack (Regular Viscosity & Low Viscosity) with Gentamycin : Methyl Methacrylate / Methyl acrylate copolymer blend Sterilised using ethylene oxide gas. . 22 Bone Wax, Sterilised 23 Bulldog Clamp (Micro), Curved 3.5 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 24 Bulldog Clamp (Micro), Curved 4 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 25 Bulldog Clamp (Micro), Curved 6 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 26 Bulldog Clamp (Micro), Curved 7.5 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 27 Bulldog Clamp (Micro), Curved 9 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 28 Bulldog Clamp (Micro), straight 3.5 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 29 Bulldog Clamp (Micro), straight 4 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 30 Bulldog Clamp (Micro), straight 6 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 31 Bulldog Clamp (Micro), straight 7.5 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 32 Bulldog Clamp (Micro), straight 9 cm lengths, Single use bulldog clamps are a lightweight radiopaque plastic construction. Colour coded according to clamp size and pressure. Atraumatic Jaw designs. Parallel clamp designed for maximum occlusion and atraumatic pressure. Latex-safe. 33 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – BLACK SIZE – SHOULD BE MATCH WITH 30 LETRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 34 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – BLACK SIZE – SHOULD BE MATCH WITH 50 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 35 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – YELLOW SIZE – SHOULD BE MATCH WITH 30 LETRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 36 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – BLACK SIZE – SHOULD BE MATCH WITH 100 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 37 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – YELLOW SIZE – SHOULD BE MATCH WITH 50 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 38 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – YELLOW SIZE – SHOULD BE MATCH WITH 100 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 39 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – RED SIZE – SHOULD BE MATCH WITH 30 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 40 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – RED SIZE – SHOULD BE MATCH WITH 50 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 41 BAG, BIOMEDICAL WASTE CARRYING BAG COLOUR – RED SIZE – SHOULD BE MATCH WITH 100 LITRES BIN SPECIFICATIONS – • VIRGIN PLASTIC NON CHLORINATED POLYMER MADE. • SPECIALLY DESIGNED BIODEGRADABLE WASTE COLLECTION BAGS. • WITH EASY TO HOLD. • WITH PLASTIC CABLE BREAK AWAY LOCK / COLLAR TIE / KNOT ARRANGEMENT. • ALL BAGS ARE TO BE CUSTOMIZED WITH BIO-HAZARD SIGN AND PRE-PRINTED AS PER WBPCB NORMS. • THICKNESS OF THE PLASTIC SHOULD BE MINIMUM 55 MICRONS. • SHOULD BE LEAK PROOF. • PUNCTURE RESISTANT. • SHOULD HAVE UNIFORM DENSITY WITHOUT DEFECTS LIKE TEARS, HOLES OR WEAK AREAS. • BIS 9738:2003 CERTIFIED. 42 Bag, Colostomy/Ilestomy one-pc transparent bag with oval shaped spiral adhesive including flex zones, hide away outlet and integrated charcoal filter-- custom cut 12-75 mm 43 BAG, DISPOSABLE, THORACIC DRAINAGE SYSTEM 44 Bain circuit (adult), Manually adjustable non metallic APL valve for MRI compatibility 45 Bain circuit (paediatric), Manually adjustable non metallic APL valve for MRI compatibility 46 Battery Operated Sternal Saw Sysytem Specification :- • All attachment should be made of stainless steel. • Should be fully autoclavable. Reciprocating Saw hand Piece: • Should have sternum guard • Should have minimum 1500 CM • Weight of hand piece with battery should be not more than 3.5 IBS • Saw noise level Should not more than 93 dp • Should be autoclavable except battery • Should be supplied with 2 blades of sternotomy surgery-effective length 34-43 mm, width-1.3mm-9 mm. Saggital Saw handpiece (Redo sternum saw) • The Oscillating saw head should be 360 deg rotatable in eight steps. • Power – More than 220 W • CPM - 0-15,000 • Amplitude - 4°47 • Weight – Less than 1650 gm including battery & lid • Should be supplied with 2 blades for TJR surgery – Effective Length 85-95mm, Width 19-25mm, Thickness 0.89 – 1.37mm • Should be supplied with 2 blades for General Traumatology – Effective Length 35 – 65 mm, Width 10-50mm, thickness 0.5 – 0.9mm Battery • It should be NiMH/NiCd/Lithium Ion Battery. • The Battery should be of more than 1.7 Ah. Lid • Should have quick locking facility. Sterile Funnel • Should be made of PEEK. Battery Removal Device • For Intra operative removal of Battery. • Should be made of PEEK. Battery Charger • The Battery charger should have 4 charging station. with electronically controlled charging process and automatic switch to maintain the charge. • It automatically should indicate when the battery needs to be replaced. Sterilization Basket • The system should be supplied with perforated basket made of stainless steel. • It should proper holding slots for handpiece & attachment. Sterilization Container • Should be made of aluminum. • The container lid should have reusable PTFE Permanent bacteria filter. The PTFE Bacteria filter last up to 1000 sterilization cycles. 47 Beaker Glass, Graduated, 1000ml, High-quality Borosilicate Glass that can be heated directly in an open flame 48 Beaker Glass, Graduated, 250ml, High-quality Borosilicate Glass that can be heated directly in an open flame 49 Beaker Glass, Graduated, 500ml, High-quality Borosilicate Glass that can be heated directly in an open flame 50 Beaker Glass, Graduated, 750ml, High-quality Borosilicate Glass that can be heated directly in an open flame 51 Biopsy Needle with gun, Disposable, Size 14G/16G, Length - 10/16 CM 52 Biopsy Needle with gun, Disposable, Size 18G Length - 10CM 53 Biopsy Needle with gun, Disposable, Size 18G Length - 16CM 54 Biopsy Needle with gun, Disposable, Size 18G Length - 20CM 55 Biopsy Needle with gun, Disposable, Size 18G Length - 25CM 56 Biopsy Needle with gun, Disposable, Size 20G, Length - 10/16/20 CM 57 BLADES, STAINLESS STEEL SAFETY RAZOR BLADES 58 Cannula, Aortic Arch Cannula - Neonatal : Straight Tip, Soft Flexible bodyenables easy poioning yet resist kinking, 8Fr ( 2.7 mm), 1/4 Connector, CE / USFDA Certified. 59 Cannula, Aortic Arch Cannula - Paediatric : Straight Tip, Soft Flexible bodyenables easy poioning yet resist kinking, 16Fr, 1/4 Connector, CE / USFDA Certified. 60 CANNULA, AORTIC ARCH CANNULA WITH METAL LEGS, CE / USFDA Certified. 61 Cannula, Vessel Cannula : Clear body, soft plastic tip, female luer lock. Size : 3 mm Blunt tip 62 CAPD Catheter Tench koff Curved 62cm. 63 CAPD Catheter Tench koff Straigth 42cm. 64 Cardiac Pacing Wire (Electrode), Temporary, Sterile, Cir,Tapercut, 26 mm needle with self retaining system 65 Catheter Permanent /Tunnelled/cuffed (Paediatric) 66 Catheter Permanent /Tunnelled/cuffed 19cm 67 CATHETER, AORTIC BALLOON VALVOPLASTY CATHETER 68 CATHETER, CARDIAC CATHETER INTRODUCER SHEATH WITH NEEDLE (FEMORAL) - 5F/6F/7F 69 CATHETER, FOGARTY ARTERIAL EMBOLECTOMY CATHETERS SIZE 3Fr - 7Fr 70 CATHETER, MITRAL BALLOON ANGIOPLASTY CATHETER 71 CATHETER, PULMONARY BALLOON ANGIOPLASTY CATHETER 72 CATHETER, SUBCLAVIAN CATHETER INTRODUCER SET 45 CM (PLAIN) 73 Central Venous Catheter : 24G Radiopaque polyurethane peripherally inserted central venous catheter for premature neonates weighing <1KG 74 Central Venous Catheter : 28G Radiopaque polyurethane peripherally inserted central venous catheter for premature neonates weighing <1KG 75 CLIPS, TOWEL HOLDING, CROSS ACTION 76 Closed Loop Suction Catheter : Closed Loop Suction Catheter Systems, Size: ( 6 Fr, 8Fr, 10Fr, 12Fr): includes protective soft sleeve to completely isolate suction catheter from direct contact to caregivers and usages, life 48-72 hours 77 Closed loop Suction Catheter: Closed loop suction Catheter Systems, Size: (6Fr, 8Fr, 10Fr) includes protective soft sleeve to completely isolate suction catheter from direct contact to caregivers and usage life 48-72 hours 78 CANNULA, Cardiopledigia Cannula (Neontal) : Radiopaque tips attached to clear bodies , left heart venting long tip and standard introducer. Size : 14 ga (7 Fr.), CE / USFDA Certified. 79 CANNULA, Cardiopledigia Cannula (Paediatric) : Radiopaque tips attached to clear bodies with separate vent lines , include aortic root pressure monitoring and left heart venting. Size : 16 ga (5 Fr.), CE / USFDA Certified. 80 COLLAGEN SHEETS 10 X 10CM 81 COMPOSITE LIGHT WEIGHT MESH MADE OF POLYPROPYLENE AND POLYGLACTIN SIZE 9 CM - 11 CM X 14 CM -16 CM 82 COMPOSITE LIGHT WEIGHT MESH MADE OF POLYPROPYLENE AND POLYGLACTIN SIZE 14 CM - 16 CM X 14 CM - 16 CM 83 COMPOSITE LIGHT WEIGHT MESH MADE OF POLYPROPYLENE AND POLYGLACTIN SIZE 28 CM - 32 CM X 28 CM - 32 CM 84 COMPOSITE LIGHT WEIGHT MESH MADE OF POLYPROPYLENE AND POLYGLACTIN SIZE 5 CM - 7 CM X 10 CM - 12 CM 85 CORONARY ANGIOPLASTY GUIDE WIRE 0.014 DIAMETER, HYDROPHILIC WIRE 86 CORONARY ANGIOPLASTY GUIDE WIRE (PTCA WIRE) 87 Corrugated Drainage Sheet, Sterile, Multichannel, with radio opaque line, Single Use - All sizes 88 Cover Glass 0.16 to 0.19 mm thick, rectangular, sizes [25 mm X 50 mm] 89 Cover Glass 0.16 to 0.19 mm thick, square of 5 sizes [7/8 or 4/5 or 3/4 or 11/4 or 1½”] 90 CVC Single Lumen Catheter : 22 G / 24G Polyurethane Single Lumen 8 cm length. 91 Diagnostic Catheter, Amplatz –Left size: 6F,7F • Catheter length should be 100 - 110cm. 92 Diagnostic Catheter, Amplatz -Right size: 6F,7F • Catheter length should be 100 - 110cm. 93 Diagnostic Catheter, size :- 4Fr.,5Fr., & 6Fr. • Shape should be Judkin Left. • Catheter length should be 100 - 110cm. 94 Diagnostic Catheter, size :- 4Fr.,5Fr., & 6Fr. • Shape should be Judkin Right. • Curve 3.0,3.5,4.0,4.5 & 5.0cm. Catheter length should be 100-110 CM 95 Diagnostic Catheter, size :- 6F & 7F . • Shape should be Amplatz Right -1 . • Catheter length should be 90 - 110cm. 96 Diagnostic Catheter, size :- 6F & 7F . • Shape should be Amplatz Right -2 . • Catheter length should be 90 - 110cm. 97 CANNULA, DISPOSABLE THORACIC DRAINAGE WITH BAG 98 Diagnostic Catheter, size: 6Fr. • Shape should be Multipurpose. • Catheter length should be 90 - 110cm. 99 Diagnostic Glide catheter for Abdominal angiographiy Size: 5Fr & 6 Fr. • Should be Hydrophilic polymer coated catheter. • Should be soft tip is installed on distal end. • Should be available Different shape type. 100 Diagnostic Glide catheter for Cerebral angiographiy Size: 5Fr & 6 Fr. • Should be Hydrophilic polymer coated catheter. • Should be soft tip is installed on distal end. • Should be available Different shape type. 101 DISPOSABLE NEEDLES 18G 102 DISPOSABLE NEEDLES 20G 103 DISPOSABLE NEEDLES 22G 104 DISPOSABLE NEEDLES 23G 105 DISPOSABLE NEEDLES 24G 106 DISPOSABLE NEEDLES 26G