| 1 | 1 | Providing services for daily manning and operation of plant and machinery for 11 months concurrently in three shifts per day by deploying 01 Electrician in each shift separately on each intallation as mentioned below, round the clock including Sundays and holidays from the date of commencement of work/handing taking over of installation between contractor and department, all as specified and directed by Engr-in-charge.\n(i) DG set 03 Nos (02 Nos of 250 KVA and 01 No 750 KVA) UPS 05 Nos AMF Panel, LT Panel, APFC Panel, Isolation transformer and other control and switch gear Installed at New MH.\n(ii) Total Nos of units : 01 intallation x 334 days x 03 Shifts = 1002 Shifts | | | |
|---|
| 2 | 1.01 | Basic rate (Per person per Shift) | | 1002 | Per Shift |
|---|
| 3 | 1.02 | Employers contribution towards Employees Provident Fund (Per person per Shift) | | 1002 | Per Shift |
|---|
| 4 | 1.03 | Contribution towards Employees State Insurance Corporation (Per person per Shift) | | 1002 | Per Shift |
|---|
| 5 | 1.04 | Over head and profit Per Shift | | 1002 | Per Shift |
|---|
| 6 | 1.05 | Labour welfare cess ( based on the prevailing rates) Per shift | | 1002 | Per Shift |
|---|
| 7 | 2 | Providing services for daily manning and operation of plant and machinery for 11 months concurrently in three shifts per day by deploying 01 Electrician in each shift separately on each intallation as mentioned below, round the clock including Sundays and holidays from the date of commencement of work/handing taking over of installation between contractor and department, all as specified and directed by Engr-in-charge.\n(i) DG Set 1 No 220 KVA installed at RIMC.\n(ii) Total Nos of units : 01 intallation x 334 days x 03 Shifts = 1002 Shifts | | | |
|---|
| 8 | 2.01 | Basic rate (Per person per Shift) | | 1002 | Per Shift |
|---|
| 9 | 2.02 | Employers contribution towards Employees Provident Fund (Per person per Shift) | | 1002 | Per Shift |
|---|
| 10 | 2.03 | Contribution towards Employees State Insurance Corporation (Per person per Shift) | | 1002 | Per Shift |
|---|
| 11 | 2.04 | Over head and profit Per Shift | | 1002 | Per Shift |
|---|
| 12 | 2.05 | Labour welfare cess ( based on the prevailing rates) Per shift | | 1002 | Per Shift |
|---|
| 13 | 2.06 | Notes for item No 1.00 & 02.00 \n(i) Any quoted rate against the items/ sub-items mentioned above which corresponds to/ works out to lower than the corresponding prevailing minimum rates of wages/ subscription/contribution towards EPF, ESIC, Bonus and LWC shall be treated as non-bonafide and such bid shall not be considered for acceptance. The prevailing rate/wage/contribution shall be as applicable on the bid submission end date. | | | |
|---|
| 14 | 2.07 | (ii) The quoted rate against bonus is to be considered for payment on actual basis. The amount is payable only after submission of valid and authentic documents in support of having paid the requisite amount of bonus to the workmen , e proof of payment. Similarly items/ sub-items of ‘contribution towards EPF’ and ‘contribution towards ESIC’ shall be payable after submission of valid & authentic document in support of proof of payment.\n\n | | | |
|---|
| 15 | 2.08 | (iii) The rate quoted for items of outsourcing shall not be less than minimum wages as notified by Government of India/ concerned State Government /Local Body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective headings/ sub itmes. In case the rate quoted are less than the prevailing rates/ instructions under any heading(s) , the bids will be treated as non bonafide/invalid, shall be disqualified and such bids shall not be considered for acceptance. In such case, the lowest bidder shall be determined from amongst the valid/ bonafide bids only. | | | |
|---|
| 16 | 2.09 | (iv) Quotation with ‘Nil’ or ‘Zero’ consideration (overhead and profit) shall be considered non bonafide. | | | |
|---|
| 17 | 2.1 | (v) In case of absence of an operator during a shift, payment of that shift shall not be made. | | | |
|---|
| 18 | 2.11 | (vi) In addition to deduction of payment as above a panelty of Rs. 1500/- per shift shall be levied for absent period. | | | |
|---|
| 19 | 2.12 | (vii) The contractor shall employ ITI qualified Electrician (skilled) having 5 yrs experience to operate the above said system round the clock\n(viii) The rates quoted by the contractor shall include employment of a reliever as per labour law and nothing extra shall be paid on this account .\n(ix) The unit rates includes cleaning of sub station, DG sets all panel boards, transformer AMF panel recording the voltage current & operation of APFC panel to maintain power factor 0.99 or unity. \n(x) A printed log sheet shall be maintained for running of DG sets as per performa held with Engr-in-charge..\n | | | |
|---|
| 20 | 3 | Maintenance and servicing of Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functioning all as per manufacturer's instructions and directions. \nNotes: (i) The tenderer shall submit a copy of MOU with M/S Kirloskar/Cummins or its authorized dealer for carrying out servicing/repairs/preventive maintenance of 'B' check after acceptance of contract for claiming of payment.\n | | | |
|---|
| 21 | 3.01 | Item No 3 contd :- (ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set along with connected Alternator and Panel Board including items covered in 'A' Check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge. The Contractor shall carry out periodical inspections during the maintenance period for the smooth functioning of the DG set once in a month and shall also attend all the maintenance works as and when required. List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications. (iii) Spare parts, such as engine oil and radiator coolant oil shall be measured and paid separately but cost of labour for filling of oils shall be deemed to be included in the quoted rate.\n(iv) Cost of all consumables like diesel/oil filter etc or any other items required during the maintenance period shall be deemed to be included in the rate quoted for this item.\n\n | | | |
|---|
| 22 | 3.02 | (a) 750 KVA DG set \nMake:- Cummins with AMF panel | | 1 | Each job |
|---|
| 23 | 3.03 | (b) 500 KVA DG Set\nMake Cummins without AMF | | 1 | Each job |
|---|
| 24 | 3.04 | (c) 250 KVA DG set \nMake:- Kirloskar with AMF Panel | | 2 | Each job |
|---|
| 25 | 3.05 | (d) 200 KVA DG Set\nMake Cummins without AMF | | 1 | Each job |
|---|
| 26 | 3.06 | (e) 82.5 KVA DG Set\nMake Kirloskar with AMF | | 1 | Each job |
|---|
| 27 | 3.07 | (f) 62.5 KVA DG Set\nMake Kirloskar without AMF | | 1 | Each job |
|---|
| 28 | 3.08 | (g) 40 KVA DG Set\nMake Kirloskar without AMF | | 1 | Each job |
|---|
| 29 | 3.09 | (h) 70 HP IC engine pump\nMake Kirloskar | | 1 | Each job |
|---|
| 30 | 4 | Overhauling of following mentioned self starter assembly , suitable up to 750 KVA DG Sets by disconnecting & removing from the engine cleaning all accessories replacing worn out parts such as Brushes / bushes / contact plates, jumping leads & seal & re-varnishing the field coil armature & re-assembling the same & refixing into the engine including testing all as manufactures instruction & all as specified & directed. Make : TVS/Delco / Remi | | | |
|---|
| 31 | 4.01 | (a)Self starter assembly 24V DC. | | 1 | Each job |
|---|
| 32 | 4.02 | (b) Self starter assembly 12V DC. | | 2 | Each job |
|---|
| 33 | 5 | Supply only Engine oil SAE 20W/40W in Red colour. Make : Volvoline / IOC/HP/Castrol | | 600 | Litre |
|---|
| 34 | 6 | Supply only pure coolant (not ready cool) as per Instructions and recommendations of manufacturer. | | 200 | Litre |
|---|
| 35 | 7 | Supply only of distilled water alongwith coolant as per ratio recommended by OEM incl draining of radiator and removing sludge etc complete all as directed by Engr in charge | | 200 | Litre |
|---|
| 36 | 8 | Supply only lead acid sealed battery suitable for DG set 12 Volts 150 Ah complete Make: Cummins/ Exide/ AMRON | | 4 | Each |
|---|
| 37 | 9 | Disconnecting and taking out defective battery lead and supply, fixing, connecting & testing battery lead PVC insulated with multi stranded copper conductor single core of size 35 sqmm one side fixed soldering with copper thimble & other side with brass battery terminal, lugs of heavy duty 'B' compression glands 1.50 meter length applying petroleum jelly complete all as specified & directed. | | 2 | Set of Two |
|---|
| 38 | 10 | Supply only in replacement of U/S Air filter element for following capacities of DG Sets as per existing make complete all as specified and directed for following:- | | | |
|---|
| 39 | 10.01 | (a) 750 KVA DG set \nMake:- Cummins with AMF panel | | 1 | Each job |
|---|
| 40 | 10.02 | (b) 500 KVA DG Set\nMake Cummins without AMF | | 1 | Each job |
|---|
| 41 | 10.03 | (c) 250 KVA DG set \nMake:- Kirloskar with AMF Panel | | 2 | Each job |
|---|
| 42 | 10.04 | (d) 200 KVA DG Set\nMake Cummins without AMF | | 1 | Each job |
|---|
| 43 | 10.05 | (e) 82.5 KVA DG Set\nMake Kirloskar with AMF | | 1 | Each job |
|---|
| 44 | 10.06 | (d) 62.5 KVA DG Set\nMake Kirloskar without AMF | | 1 | Each job |
|---|
| 45 | 10.07 | (e) 40 KVA DG Set\nMake Kirloskar without AMF | | 1 | Each job |
|---|
| 46 | 10.08 | (e) IC Engine Pump 60 HP\nMake Kirloskar | | 1 | Each Job |
|---|
| 47 | 11 | Supply only multifunction LED three line display meter having feature to measure Volts, Amps, KW, KWH, Active power, reactive power, power factor in repair of existing LT panel board complete incl making connection with CT complete.\nMake:- Schneider Conzerve/L&T/Siemens | | 4 | Each |
|---|
| 48 | 12 | Disconnecting & taking out carefully old unserviceable AVR unit and supply ,fixing connecting & testing AVR unit suitable for DG Set upto 250 KVA complete all as specified and directed as per existing make suitable for any type/make of DG set. | | 1 | Each |
|---|
| 49 | 13 | Disconnecting & taking out carefully old unserviceable AVR unit and supply ,fixing connecting & testing AVR unit suitable for DG Set upto 500/750 KVA complete all as specified and directed as per existing make suitable for any type/make of DG set. | | 1 | Each |
|---|
| 50 | 14 | S&F in replacement of unserviceable parts for the DG Sets of any capacity complete all as specified & directed:- Make:- Kirloskar/Cummins or equivalent make as approved by GE. | | | |
|---|
| 51 | 14.01 | (a) Water separator Cat No. 3231787 | | 1 | Each |
|---|
| 52 | 14.02 | (b) Oil temp gauge Cat No. 500412 | | 1 | Each |
|---|
| 53 | 14.03 | (c) Water temp gauge Cat 500108M | | 3 | Each |
|---|
| 54 | 14.04 | (d) Oil pressure gauge Cat 500109 | | 3 | Each |
|---|
| 55 | 14.05 | (e) Hour meter 501151. | | 3 | Each |
|---|
| 56 | 14.06 | (f) Fault display Annunciation panel | | 4 | Each |
|---|
| 57 | 14.07 | (g) Dust cap 3225660 | | 2 | Each |
|---|
| 58 | 14.08 | (h) Ignition switch 504975 | | 2 | Each |
|---|
| 59 | 14.09 | (j) Switch temp 3408632 | | 1 | Each |
|---|
| 60 | 14.1 | (k) Switch pressure 4984880 | | 2 | Each |
|---|
| 61 | 14.11 | (l) Sump hose. | | 2 | Each |
|---|
| 62 | 14.12 | (m) Coolant box. | | 1 | Each |
|---|
| 63 | 14.13 | (n) Steel braded fuel line with clamp | | 6 | RM |
|---|
| 64 | 14.14 | (o) Belt fan 178527. Make:- Fenner/Dunlop. | | 2 | Each |
|---|
| 65 | 14.15 | (p) Belt WP 200328. Make:- Fenner/Dunlop. | | 2 | Each |
|---|
| 66 | 14.16 | (q) Belt alternate 178509. Make:- Fenner/Dunlop. | | 2 | Each |
|---|
| 67 | 14.17 | (u) Digital Volt meter 96mm x 96mm 0-500 V. Make:- Schneider Conzerve /Neptune/L&T. | | 2 | Each |
|---|
| 68 | 14.18 | (v) Digital Ammeter 96mm x 96mm 0-300 A. Make:- Schneider Conzerve /Neptune/L&T. | | 2 | Each |
|---|
| 69 | 15 | M & L for painting of DG set 200 KVA with two coats of DUCO enamel paint of ICI brand of approved colour after scrapping thoroughly the existing corroded paint, dirt/dust, oil and grease from the steel surface complete all as specified and directed. | | 1 | Each job |
|---|
| 70 | 16 | M & L for painting of tank 1000 ltrs with two coats of DUCO enamel paint of ICI brand of approved colour over a coat of red oxide metal primer after scrapping thoroughly the existing corroded paint, dirt/dust, oil and grease from the steel surface complete all as specified and directed. | | 2 | Each job |
|---|
| 71 | 17 | Material and labour for CPRI approved chemical earthing complete with copper pipe electrode 50 mm dia, 2 Mtr long with terminal size 50x6 mm buried directly in ground not less than 2.25 m deep below normal ground level and backfilled with gel type compound, connected with copper strip earth lead by means of nuts bolts check nuts GI washers etc including PVC access well & cover with and incl necessary earth work in soft/loose soil for bore hole upto required depth for earth electrode including testing on completion all as specified and directed. \nMake; SNE/OBO/ENNOVE\n | | 16 | Each |
|---|
| 72 | 18 | Supply only in replacement of unserviceable MCCB 415 Volt, 25 KA, 3 pole 100 Amp thermal magnetic 1CS=100% ICS all as specified and directed. Make-Lexic legrand /GE /Schneider/Siemens | | 2 | Each |
|---|
| 73 | 19 | All as per item No 18.00 here in above but 160 Amp | | 2 | Each |
|---|
| 74 | 20 | Supply only in replacement of u/s MCCB FP 200 Amps 25 KA 4 Pole ICU=100%ICS Make-Lexic Legrand Schneider/GE/Schneider(NSX)/ Siemens (3VL). | | 2 | Each |
|---|
| 75 | 21 | All as per Item No 20.00 here in above but 63 Amps FP 16 KA or nearest higher size. | | 8 | Each |
|---|
| 76 | 22 | Supply & fixing integral flood light fitting LED type 250 W of die-cast IP 66 aluminium housing, 6000K lense type and toughened glass having separate surge protector 10 KV, efficiency of minimum 100 lumens/watt,clamp etc required to fix with existing bracket complete with all accessories all as directed incl taking down existing fitting complete all as specified and directed. \nMake: Havells/Crompton/Philips | | 6 | Each |
|---|
| 77 | 23 | Supply & fixing integral flood light fitting LED type 150 W of die-cast IP 66 aluminium housing, 6000K lense type and toughened glass having separate surge protector 10 KV, efficiency of minimum 100 lumens/watt,clamp etc required to fix with existing bracket complete with all accessories all as directed incl taking down existing fitting complete all as specified and directed. \nMake: Havells/Crompton/Philips | | 8 | Each |
|---|
| 78 | 24 | Supply and fixing of round low bay LED flood lights 80 Watts or nearest higher size. with lumens output 110 Lumens/watt with SPD and IP 66 certified made out of die cast alluminium housing and hook mounted incl provn of hook type anchor fastener etc complete Make Crompton Surround Neo or equalent in Havells/Wipro | | 16 | Each |
|---|
| 79 | 25 | Supply & fixing integral flood light fitting LED type 50/60 W or nearest higher size. of die-cast IP 66 aluminium housing, 6000K lense type and toughened glass having separate surge protector 10 KV, efficiency of minimum 100 lumens/watt,clamp etc required to fix with existing bracket complete with all accessories all as directed incl taking down existing fitting complete. \nMake: Crompton Profile Neo+ or equalent in Havells/Philips/Wipro | | 18 | Each |
|---|
| 80 | 26 | Supply & fixing integral type post top lantern made out of die cast aluminium housing, 70 watt LED IP 65 protection lense type and frosted acralic diffuser having separate surge protector 10 KV, efficiency of minimum 90 lumens/watt,clamp etc required to fix with existing bracket complete with all accessories all as directed incl taking down existing fitting complete. \nMake: Crompton Maple or equivalent in Havells/Philips/Wipro | | 6 | Each |
|---|
| 81 | 27 | Supply ,fixing , testing and commissioning of all in one 24 watts LED solar street light consisting of 12 Volt maintenance free battery of min 02 days backup and suitable size mono crystalline SPV module and MPPT charger with visual indication of charging ON and battery low mounted with all the standard fittings on and incl 5 Mtr long tubular galvanized pole made out of 80 mm dia GI pipe incl fixing on and incl grouting in PCC foundation complete all as specified at site Engr in charge.\nMake: Bajaj/Havells/Wipro | | 4 | Each |
|---|
| 82 | 28 | All as per item No 27.00 here and above but 20 watts | | 4 | Each |
|---|
| 83 | 29 | All as per item No 27.00 here and above but 18 watts | | 5 | Each |
|---|
| 84 | 30 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cable/erection of pole and getting out in soft/ loose all complete as specified and as directed. | | 200 | Cum |
|---|
| 85 | 31 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft/ loose soil complete all as specified and as directed. | | 90 | Cum |
|---|
| 86 | 32 | Removing of excavated soil to a distance n exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. | | 110 | Cum |
|---|
| 87 | 33 | M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, all as specified and directed. | | 10 | Cum |
|---|
| 88 | 34 | M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , all as specified and directed. | | 2 | Cum |
|---|
| 89 | 35 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. \nNote :- Only punned down sand shall be measured. | | 76 | Cum |
|---|
| 90 | 36 | M&L sub class B bricks locally available of size 23x11.5x7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete. | | 12.2 | Each |
|---|
| 91 | 37 | M & L for painting to steel pole any type after scrapping and rubbing down with sand paper preparation of old or new surface of poles including pole fittings such as cross arms of any description, anti-climbing devices, nut, bolts etc.and applying two coats of aluminum paint including numbering of poles as per existing complete all as directed and making 5 Nos of alternative strips of black, yellow paint of 30 Cm wide complete all as directed. | | 350 | Each Job |
|---|
| 92 | 38 | Dismantling existing steel poles/ struts, any size carefully for reuse including necessary excavation demolition of concrete shifting cost etc. and removing the old unserviceable rubbish etc | | 32 | Each |
|---|
| 93 | 39 | Fixing only of steel poles of any length and dia retrieved against respective demolition item No 38.00 including loading, shifting unloading errection in true vertical position complete all as directed. | | 12 | Each |
|---|
| 94 | 40 | Supply transportation upto and at site of work and erection of steel tubular swaged pole type 410 SP-22, 8.5 mtr long conforming to IS - 2713 in vertical position, applying two coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti corrosive below ground level and marking with alternate white and black paint strip 30cm wide total 5 Nos with synthetic enameled paint complete with cast Iron base plate , drilling of holes for cable entering and including taper plug all as specified. | | 20 | Each |
|---|
| 95 | 41 | M & L GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed\n(Make TATA/JINDAL/Swastik). | | 100 | Each |
|---|
| 96 | 42 | Supply & Fixing SMC junction box of size 280mm x 170mm x 110mm as per Sintex Cat No GSJB- 2818 or nearest higher size dust proof, water tight, shock proof, fire retardant, with internally embedded gasket fitted with heat treated bakelite terminals block, PVC Glands for cable entry and clamp for fixing with pole of size 32x6 mm GI flat complete all as directed \nMake:- Sintex/HENSEL/ABB/ BCH/Cape | | 60 | Each |
|---|
| 97 | 43 | Taking down and dismantling of street light fittings of any type size and model (FTL, ES, HPSV,MVL,MH, floodlight Fittings etc), and depositing the same to MES store yard for repair if any required or as directed by Engr in Charge complete. | | 126 | Each Job |
|---|
| 98 | 44 | Fixing only of street lights taken down against the item here and above but after repair and replacement of unserviceable spares / accessories for the same including refixing of street light fittings of any size , type and model to existing pole, including necessary electric connection by providing PVC insulated and sheathed aluminium conductor cable of 3 single core of size 2.50 Sqmm (nominal cross sectional area) from junction box to fittings incl testing complete all as specified and as directed. | | 60 | Each Job |
|---|
| 99 | 45 | Supply & fixing Street light fitting LED type 72 W of die-cast IP 66 aluminium housing, 60 watt LED 6000K lense type and toughened glass having separate surge protector 10 KV, efficiency of minimum 100 lumens/watt, incl adaptor (if any) required to fix with existing bracket of min 40 mm dia complete with all accessories all as directed incl taking down existing fitting complete. \nMake:Crompton Nexus Neo or equalent in Wipro/ Havells | | 30 | Each |
|---|
| 100 | 46 | All as per item No 45.00 here and above but 60 watts | | 36 | Each |
|---|
| 101 | 47 | M & L laying or passing through pipe LT UG XLPE insulated, armoured heavy duty 1100 volts grade with aluminum stranded conductor of cross sectional area 16 sq mm 4 core including taking out the old unserviceable cable complete all as directed. \n Make:- HAVELLS/POLYCAB/Grandlay | | 400 | RM |
|---|
| 102 | 48 | M & L laying or passing through pipe LT UG XLPE insulated, armoured heavy duty 1100 volts grade with aluminum solid conductor of cross sectional area 10 sq mm 4 core including taking out the old unserviceable cable complete all as directed. \n Make:- HAVELLS/POLYCAB/Grandlay | | 600 | RM |
|---|
| 103 | 49 | All as per item No 48.00 here and above but 10 sqmm 2 core | | 750 | RM |
|---|
| 104 | 50 | Supply and fixing of twin core unarmoured round PVC cable 10 sq mm aluminium conductor cable suspended with No.8 SWG GI wire and cable tie at distance of 01 mtr duly connected with earthing and clamp etc from Pole to pole complete.\nMake HAVELLS/POLYCAB/Grandlay | | 400 | RM |
|---|
| 105 | 51 | Supply and fixing/laying 40mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed.(Make : TATA/JINDAL/ITC) | | 100 | RM |
|---|
| 106 | 52 | M & L for drawing of 3 core 1.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as directed. | | 350 | RM |
|---|
| 107 | 53 | Supply and fixing of coil for contactor 40 Amps to 80 Amps as per existing sample complete incl taking out existing and necessary connections complete. | | 20 | Each |
|---|
| 108 | 54 | Supply and fixing of timer astronomical digital type in repair incl taking out existing timer and necessary connection complete\nMake:- L&T/Legrand/Havells | | 10 | Each |
|---|
| 109 | 55 | Supply and fixing of LED light fitting driver suitable for 60/72 watts fittings as per sample complete.\nMake:- Havells/Crompton/Philips | | 60 | Each |
|---|
| 110 | 56 | Supply and fixing of surge protection device 10 KV 240 Volts suitable for LED street light fitting complete \nMake:- HPL/Crompton/Philips | | 150 | Each |
|---|