| 1 | 1.001 | Purchase of CONSUMABLE GENERAL SURGICAL ITEMS for CTVS Department on Two Years Rate Contract Basis Part I | | | |
|---|
| 2 | 1.01 | Silicone Tracheostomy tube without cuff (Size 3.0, 3.5,4.0,4.5). \n• Silicone Tracheostomy tube \n• Transparent and flexible flange\n | item1 | 600 | pices |
|---|
| 3 | 2 | Tracheostomy tube with cuff ( Size 3.0, 3.5,4.0,4.5,5.0)\n• Soft seal; low pressure –high volume cuff\n• Inflation cuff showing internal diameter of TT with spring loaded one way valve for inflating and monitoring cuff pressure\n• Transparent and flexible flange\n | item2 | 600 | pices |
|---|
| 4 | 3 | Percutaneous Tracheostomy tube (Size 6.0,7.0,8.0,9.0)\n• Soft seal; low pressure –high volume cuff\n• Inflation cuff showing internal diameter of TT with spring loaded one way valve for inflating and monitoring cuff pressure\n• Transparent and flexible flange\n• The obturator should have hole for guidewire\n | item3 | 400 | pices |
|---|
| 5 | 4 | Percutaneous Tracheostomy Set with Single dilator \n• Should have introducer needle with sheath. \n• Should be with tracheostomy tube.\n• Should have a short dilator and guidewire.\n• The guide wire should have position markings.\n• Should have single dilator (white tusk/ blue rhino) with gradual \n• gradation for dilatation.\n• Guiding catheter over which the dilator is introduced.\n• Should be supplied with essential accessories - scalpel, syringe\n | item4 | 200 | pices |
|---|
| 6 | 5 | Percutaneous Tracheostomy Dilatation set with forceps.\n• Should have introducer needle with sheath. \n• Should be with tracheostomy tube.\n• Should have a short dilator and guidewire.\n• The guide wire should have position markings.\n• Should have a single guidewire dilating forceps for dilatation.\n• Guiding catheter over which the dilator is introduced. \n• Should be supplied with essential accessories - scalpel, syringe\n | item5 | 200 | pices |
|---|
| 7 | 6 | T-piece with APL Valve (Infant) \nShould be good quality, light weight, non-conductive disposable T piece with corrugate tubing 1.8m circuit length, low resistance, 500 ml bag with APL valve with 15F/22F connector, safety cap.\n | item6 | 2400 | pices |
|---|
| 8 | 7 | PVC venturi mask with 6 diluters (Adult)\n• Variable venturi system to ensure accurate concentrations of oxygen with single unit. \n• Transparent air entrainment mask with soft anatomical form with adjustable elastic strap for adult. \n• Rotating type connector for patient’s comfort. \n• Unique spring loaded mechanism locks prescribed concentration in place ensuring safety and correct oxygen concentrations. \n• 210 cm multichannel tube to ensure continuous flow of oxygen. \n• Non-Sterile, individually packed in polybag\n | item7 | 3000 | pices |
|---|
| 9 | 8 | PVC venturi mask with 6 diluters (Pediatric)\n• Variable venturi system to ensure accurate concentrations of oxygen with single unit. \n• Transparent air entrainment mask with soft anatomical form with adjustable elastic strap for adult. \n• Rotating type connector for patient’s comfort. \n• Unique spring loaded mechanism locks prescribed concentration in place ensuring safety and correct oxygen concentrations. \n• 210 cm multichannel tube to ensure continuous flow of oxygen. \n• Non-Sterile, individually packed in polybag.\n | item8 | 2000 | pices |
|---|
| 10 | 9 | Oxygen Recovery Kit\n• It should be specially designed kit with ‘T’ shaped connector for delivering oxygen. \n• It should have 15 mm connector to fit all tracheal tubes. \n• It should have suction port at elbow to facilitate oro-bronchial suctioning without disconnecting the patient from oxygen source. \n• It should have two-meter long star lumen tube to enable to connect the T-connector with oxygen source. \n• Distal end should be open for exhaling the waste gases. \n• Should be sterile and individually packed in peelable pack. \n• Unit should comprise of: ‘T’ shape connector & two meter long tube.\n | item9 | 1000 | pices |
|---|
| 11 | 10 | Bite block size 4: Bite block size 4 for oral fixation of ETT size 6.5-8.0mm, Laryngeal Tube size 2 & 2.5 tube should clip into the bite block for protection against occlusion | item10 | 400 | pices |
|---|
| 12 | 11 | Bite block size 5 :-Bite block size 5 for oral fixation of ETT size > 8.5mm, Laryngeal tube Size 2 & 2.5 LMA 2 & 2.5 tube should clip into the bite block for protection against occlusion. | item11 | 400 | pices |
|---|
| 13 | 12 | Bite block Size 6: Bite block size 6 for oral fixation of laryngeal Tube size 3,4,&5 and LMAs, Tube should clip into the bite block for protection against occlusion.\n | item12 | 600 | pices |
|---|
| 14 | 13 | Disposable ventilator/breathing circuit with heater wire (Adult)\n• Should be light weight and flexible to minimize drag on circuits, \n• Corrugated high quality (Ethylene vinyl acetate )EVA material tubings\n• Color coded heated inspiratory limb, 1.5m (22 mm)\n• Silver impregnated 0.5m humidifier connection tube,\n• Expiratory limb with water trap 1.8 m\n• Autofill humidification chamber\n• Standard Y piece \n• Angle connector with gas sampling port \n• Water trap\n• Free from phthalates and latex | item13 | 1600 | pices |
|---|
| 15 | 14 | Disposable ventilator/breathing circuit with heater wire (Paed)\n• Should be light weight and flexible to minimize drag on circuits, \n• Corrugated high quality EVA ( Ethylene vinyl acetate ) material tubings\n• Color coded heated inspiratory limb, 1.5m (22 mm)\n• Silver impregnated 0.5m humidifier connection tube,\n• Expiratory limb with water trap 1.8 m\n• Autofill humidification chamber\n• Standard Y piece \n• Angle connector with gas sampling port \n• Water trap\n• Free from phthalates and latex\n | item14 | 1000 | pices |
|---|
| 16 | 15 | Disposable chamber for BAL collection with adapter\n• Disposable sterile container for Bronchoscopy application.\n | item15 | 200 | pices |
|---|
| 17 | 16 | Nasojejunal tube 12 Fr, 14Fr, 16 Fr\n• Sterile, Nasojejunal tube, single use only\n• Medical-Grade Silicone Construction\n• Latex and DEHP free\n• High performing Anti-Reflux Valve\n• Radiopaque Striping \n• Length 120 cm\n | item16 | 1600 | pices |
|---|
| 18 | 17 | Patient Warming Blanket (Adult) body full size: (206x87cm)\n• (Adult) body full size: (206x87cm) \n• Should be disposable and two layered; \n• Should consist of non-woven propylene fabric for body warming.\n• Should be usable with forced air warming units.\n• Material should be latex free and should meet flammability standard 16 CPR 1610 for safety.\n• Should be compatible with common machines | item17 | 2000 | pices |
|---|
| 19 | 18 | Patient Warming Blanket (Paediatric) Full Body (100x120cm)\n• (Paediatric) Full Body (100x120cm)\n• Should be disposable and two layered; \n• Should consist of non-woven propylene fabric for body warming.\n• Should be usable with forced air warming units.\n• Material should be latex free and should meet flammability standard 16 CPR 1610 for safety.\n• Should be compatible with common machines\n | item18 | 1600 | pices |
|---|
| 20 | 19 | Enteral feeding bag (DEHP free)\n• Enteral feeding bag intended for gastro-intestinal feeding.1-1.5 litre capacity bag.\n• Ice pouch should be provided on the rear side of the bag for preserving the food for longer intervals of time.\n• Transfer set should be directly connected to the bag.\n• Roller controller should be provided on the transfer set facilitates control on the administered feed.\n• The feeding bag should be graduated to determine precisely the quantity of the administered feed.\n• Feeding bag should be provided with a closure cap and a hanger for safe hanging during and after use.\n• Sterile, individually packed in peelable pouch.\n | item19 | 400 | pices |
|---|
| 21 | 20 | Tenckhoff Soft PD Catheter Adult \n• 15 Fr Tenckhoff Catheter, catheter length 37 cm;\n• Side ports 20\n• Curved tip guide wire \n• Introducer 16 Fr; 17 cm\n• Sheath length 10 cm\n• Distal tip to cuff distance 16.5 cm\n• Scalpel blade | item20 | 200 | pices |
|---|