| 1 | 1 | Supply of Power Fence Energizer of standard make conforming to impulse repetition period greater than or equal to 1 second and impulse duration with 500 ohm load of about 5 joules and capable of energizing over a distance of 3 kilometers. | | 1 | No |
|---|
| 2 | 2 | Supply of crystalline silicone terrestrialPhoto Voltaic module conforming to ILC 61215/IS 14286 with peak wattage of l00 watts carrying the name of the manufacture of PV module and manufacturer of solar cells | | 1 | No |
|---|
| 3 | 3 | Supply of storage 12V battery to be charged with solar photo voltaic module with rated capacity of 100AH generally lead-acid tubular battery for energizing the energizer. | | 1 | No |
|---|
| 4 | 4 | Supply of charge controller unit of standard make suitable to control the charging of the tubular battery | | 1 | No |
|---|
| 5 | 5 | Supply of battery charger unit 12V 10 A | | 1 | No |
|---|
| 6 | 6 | Supply of lightning diverter of standard make having capacity to divert up to 20 KV | | 1 | Nos |
|---|
| 7 | 7 | Supply of intermediate posts having size of 25x25x3mm,2.4 meter long, painted holes of 6mm size in the vertical side starting at 2.5feet from the bottom Inter | | 65 | Nos |
|---|
| 8 | 8 | Supply of corner posts made of Gl pipe of B class having 50 NB, 2.4meter long having diametrically. | | 12 | Nos |
|---|
| 9 | 9 | Supply of support post to the corner post made of Gl pipe 25 NB. B-type along with fastening assembly. | | 12 | Nos |
|---|
| 10 | 10 | Supply of HT wire of standard make 2.59 mm size, high tensile wire with minimum 230-300 grams per square meter zinc coating with ultimate tensile strength of 140 kg/sq m for use as conducting wire | | 90 | Kg |
|---|
| 11 | 11 | Supply of 14 gauge wire, high tensile, zinc coated for winding the PP reel insulator etc. | | 7 | Kg |
|---|
| 12 | 12 | Supply of lead out cable-double insulated inner core wire 2 sq.mm of withstanding 15KV voltage for connecting purpose | | 60 | m |
|---|
| 13 | 13 | Supply of super strain insulator made of virgin polymer UV stabilized fire resistant and suitable to withstand 15kv voltag | | 72 | No |
|---|
| 14 | 14 | Supply of intermediate post insulator (PP reel insulator)made of virgin high density poly propylene with break down voltage of 15kv | | 200 | Nos |
|---|
| 15 | 15 | Supply of tension spring made of hot dipped steel of standard make | | 6 | Nos |
|---|
| 16 | 16 | Supply of wire Tightner made of Aluminium-Silicon alloy | | 21 | Nos |
|---|
| 17 | 17 | Supply of joint clamp, zinc coated, 60 micron thick | | 9 | Nos |
|---|
| 18 | 18 | Supply of Clamp for fastening conducting wire around posts hot dipped galvanized | | 12 | Nos |
|---|
| 19 | 19 | Supply of warning signs made of long standing polymer sheet of yellow colour with black lettering | | 3 | nos |
|---|
| 20 | 20 | Supply of Rope gate set consisting of steel rope of 5 meters along with one super strain insulator, insulated handle and hook assembly | | 9 | Nos |
|---|
| 21 | 21 | Supply of Earth kit consisting of 3 feet long SS rod of size 8-10mm packed with earthing mixture consisting of bentonite clay | | 6 | Nos |
|---|
| 22 | 22 | Supply of Base unit box for housing energizer battery, charge control unit etc. Body of which is made of metal plate, painted coated provided with stand of 1 meter height made of four legs of MS pipe of 25mm or MS angle of 25mmx25mmx3mm or single leg of painted MS pipe of 50mm diameter | | 1 | Nos |
|---|
| 23 | 23 | Supply of Digital voltmeter of standard make | | 1 | Nos |
|---|
| 24 | 24 | Supply of Tool kit consisting of wire tighter rod, double headed spanner, high tensile wire cutter and cutting player. | | 1 | Nos |
|---|
| 25 | 25 | Supply of Neon tester for testing line voltage | | 1 | Nos |
|---|
| 26 | 27 | Alienging the fence in the field as per the direction of departmental officers , clearing the fence line of all weeds to a width of 1.5 m, fixing the corner posts at an approximate distance 50 m pits of size 30cmx30 cmx 45 cm in hard soil consolidated by ramming gravel and gungle stone pieces and supported by support posts, fixing intermeediate posts by hammering the same into hard earth to a depth of 45 cm drawing the conducting wire through PP reel insulaters tide to the intermediate post using binding wire and stretching to required strength by connecting the ends to super staring insulators tied to the corner post in 5 strands the bottom mostline at an average height of 15 cm from the ground and the strands at approximate intervels 20 cm , 25 cm , 35 cm and 40 cm. connecting conducting wire in every strand across each corner post by means of jointing clamps fixing wire tightener in every stramps at approximate intervels of 200 m conneccting tension spring in the top most twop conductors at approximate intervels at 200 m providing flood chain set and and flood controll unit at river crossing points conecting super earthn kit to the earth conductor by means of lead out cable and jointing clamp fixing vertical conducting wire in the forest side of the fence supported by semi circular conducting wire loop fixed to the conducting wire stramp by means of joining clamp for protecting the post from wilde animal providing gate assembly at places as decided by the departmental officers by means of rope gate set fixed to corner post acting as gate posts by means of super strain insulators at the fixed end and conducting hooks at the data cable end. providing line connection at the gate point through lead out cable laid underground and energizing the live conductors of the fence by means of energizer fixed at suitable locations at approximate distance of 2Km along the fence connect tho the live wire earth wire by means of lead out cable providing sufficiant no of earth kits in the line to the earth lines connecting the tubular battery to the energizer through the lead out cable and connecting the xolar pannel to the battery by means of 2 core wire through charge controll unit and fixing lighting dirverter in the circuit at approximate location to protect the energizer from lightning voltage providing and fixing stands for the solar pannel and metalic box for safe storage of energiser and battery testing the circuit for required current and voltage and commissioning the fence installation | | 1650 | m |
|---|
| 27 | 28 | Head load | | 1 | LS |
|---|
| 28 | 29 | GST 12% for materials | | 1 | LS |
|---|
| 29 | 30 | Unforeseen if any | | 1 | LS |
|---|