| 1 | 1 | Material & Labour for disconnecting and dismantling window type air conditioner of capacity 1.5/2TR from existing position and transporting to local workshop from MES store yard for replacing of major components which is required to make functioning of the AC such as compressor, condenser, condensing coil, evaporator coil, motor and body repair etc including servicing and filling of suitable refrigerant gas up to required pressure after leakage test complete required for make function the AC in all respect and transporting back, re installing at same/different location as shown, connecting, commissioning for complete all as specified & directed. | | 60 | Each Job |
|---|
| 2 | 2 | Ditto all as per Serial item No 1, but for Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 120 | Each Job |
|---|
| 3 | 3 | Ditto all as per Serial item No 1, but for Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 60 | Each Job |
|---|
| 4 | 4 | Ditto all as per Serial item No 1, but for Water Cooler of capacity 40/40, 40/80 or 60/120. | | 20 | Each Job |
|---|
| 5 | 5 | Ditto all as per Serial item No 1, but for 3 phase Tower / Ductable Split type AC of capacity 3/4 TR. | | 3 | Each Job |
|---|
| 6 | 6 | Ditto all as per Serial item No 1, but for Refrigerator of capacity 165Ltrs to 310 Litres. | | 3 | Each Job |
|---|
| 7 | 7 | Material & Labour for disconnecting window type air conditioner of capacity 1.0/1.5/2.0 Ton from position or electric supply, servicing at same location including cleaning of interior parts and body with solvent materials, filter cleaning/water washing and for replacement of unserviceable parts, re connecting, and commissioning complete all as specified & directed. | | 80 | Each Job |
|---|
| 8 | 8 | Ditto all as per Serial item No 7, but for Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 200 | Each Job |
|---|
| 9 | 9 | Ditto all as per Serial item No 7, but for Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 150 | Each Job |
|---|
| 10 | 10 | Ditto all as per Serial item No 7, but for Water Cooler of capacity 40/40, 40/80 or 60/120Ton. | | 30 | Each Job |
|---|
| 11 | 10.1 | NOTES FOR SERIAL ITEM NO 1 TO 10 \n1. Minor Spares costing upto Rs 250/- and minor repairs up to Rs 500/- shall be included in the rate quoted above. \n 2. Major Spares such as compressor, condenser, cooling coil, fan motor etc shall be measured and paid separately.\n | | | |
|---|
| 12 | 11 | Supply in repairs, Hermetically sealed compressor unit suitable for Window/split type ACs of 1.5 Ton capacity in exchange of the existing unserviceable sealed compressor unit including connecting up complete all as specified & directed. | | 30 | Each Job |
|---|
| 13 | 12 | Ditto all as per Serial item No 11, but for 2.0 TR. | | 20 | Each Job |
|---|
| 14 | 13 | Ditto all as per Serial item No 11, but for split AC 2TR Inverter type. | | 2 | Each Job |
|---|
| 15 | 14 | Ditto all as per Serial item No 11, but for split AC 1.5TR Inverter type. | | 2 | Each Job |
|---|
| 16 | 15 | Ditto all as per Serial item No 11, but for suitable for water cooler of capacity 40/40, 40/80 Litres. | | 2 | Each Job |
|---|
| 17 | 16 | Ditto all as per Serial item No 11, but for suitable for Water Cooler of capacity 60/120. | | 2 | Each Job |
|---|
| 18 | 17 | Ditto all as per Serial item No 11, but for suitable for Refrigerator of capacity 165 to 210 Litres. | | 1 | Each Job |
|---|
| 19 | 18 | Ditto all as per Serial item No 11, but for suitable for Refrigerator of capacity 220 to 310 Litres. | | 1 | Each Job |
|---|
| 20 | 19 | Ditto all as per Serial item No 11, but for suitable for Deep Freezer of capacity 420 Liters. | | 1 | Each Job |
|---|
| 21 | 20 | Supply & Fix Condensing coil and aluminium fins suitable for 1.5TR capacity Window type Air conditioner including necessary brazing, gas charging, leak testing, Vacuumnising etc, including taking down old unserviceable condensing coil complete all as specified. | | 2 | Each Job |
|---|
| 22 | 21 | Ditto all as per Serial item No 20, but for 2.0 TR. | | 1 | Each Job |
|---|
| 23 | 22 | Ditto all as per Serial item No 20, but for Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 6 | Each Job |
|---|
| 24 | 23 | Ditto all as per Serial item No 20, but for cooling coil of Indoor unit of Split type Air Conditioner 1.5/2.0 Ton. | | 2 | Each Job |
|---|
| 25 | 24 | Ditto all as per Serial item No 20, but for condenser coil suitable for Water cooler of capacity 40/40, 40/80. | | 1 | Each Job |
|---|
| 26 | 25 | Ditto all as per Serial item No 20, but for condenser coil suitable for Water cooler of capacity 60/120. | | 1 | Each Job |
|---|
| 27 | 26 | Supply & Fix Condensing coil and metallic fins suitable for 165 to 210 Ltrs capacity Refrigerator including necessary brazing, gas charging, leak testing, Vacuumnising etc including taking down old unserviceable condensing coil complete all as specified. | | 1 | Each |
|---|
| 28 | 27 | Ditto all as per Serial item No 26, but for condenser coil suitable for refrigerator of capacity 220 to 310 Litres. | | 1 | Each |
|---|
| 29 | 28 | Supply & Fix in repair Evaporator coil made out of Copper tube suitable for Refrigerator of capacity 165 to 210 Ltrs complete all as specified and directed. | | 1 | Each |
|---|
| 30 | 29 | Supply & Fix in repair Evaporator coil made out of Copper tube suitable for Refrigerator of capacity 290 to 310 Ltrs complete all as specified and directed. | | 1 | Each |
|---|
| 31 | 30 | Supply & Fix in repair Starting capacitor 120/150 MFD suitable for window/split AC complete complete all as specified and directed. | | 6 | Each |
|---|
| 32 | 31 | Supply & Fix in repair Running capacitor 45/ 50 MFD suitable for Window / Split type AC complete all as specified and directed. | | 170 | Each |
|---|
| 33 | 32 | Supply & Fix in repair Running capacitor 36 MFD suitable for Window/Split type AC complete all as specified and directed. | | 50 | Each |
|---|
| 34 | 33 | Supply & Fix in repair Running capacitor 10 MFD suitable for Window AC/ Split AC/Water Cooler. | | 30 | Each |
|---|
| 35 | 34 | Supply & Fix in repair Running capacitor 8 MFD suitable for Window / Split type AC . | | 20 | Each |
|---|
| 36 | 35 | Supply & Fix in repair Capacitor 6 MFD, 240V suitable for fan motor of Window / Split type AC complete all as specified and directed. | | 60 | Each |
|---|
| 37 | 36 | Supply & Fix in repair Capacitor 4 MFD, 240V suitable for fan motor of Window / Split type AC complete all as specified and directed. | | 60 | Each |
|---|
| 38 | 37 | Supply & Fix in repair Capacitor 2/2.5 MFD, 240V suitable for Split type AC indoor unit complete all as specified and directed. | | 30 | Each |
|---|
| 39 | 38 | Supply & Fix in repair Capacitor 1.5 MFD, 240V suitable for Split type AC indoor unit complete all as specified and directed. | | 30 | Each |
|---|
| 40 | 39 | Supply & Fix in repair Fan motor 1/5 HP, 240V long shaft suitable for Window type AC of any capacity, make or model complete all as specified and directed. | | 25 | Each |
|---|
| 41 | 40 | Supply & Fix in repair Fan motor 1/5 HP 240V suitable for outdoor unit of split type AC of any capacity, make or model complete all as specified and directed. | | 25 | Each |
|---|
| 42 | 41 | Supply & Fix in repair Fan motor 1/35 HP 240V with leaf suitable for water cooler complete all as specified and directed. | | 1 | Each |
|---|
| 43 | 42 | Supply & Fix in repair Fan motor 240V suitable for outdoor unit of inverter type Split AC of any capacity make or model complete all as specified and directed. | | 15 | Each |
|---|
| 44 | 43 | Supply & Fix in repair Fan motor 240V suitable for indoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. | | 2 | Each |
|---|
| 45 | 44 | Supply & Fix in repair Fan blade suitable for Window type AC of any capacity, make or model complete all as specified and directed. | | 10 | Each |
|---|
| 46 | 45 | Supply & Fix in repair Fan blade suitable for Outdoor unit of Split type AC of any capacity, make or model complete all as specified and directed. | | 6 | Each |
|---|
| 47 | 46 | Supply & Fix in repair Thermostat switch suitable for window type AC of any capacity, make or model complete all as specified and directed. | | 6 | Each |
|---|
| 48 | 47 | Supply & Fix in repair Starting relay pin type suitable for Window/Split type AC of any capacity, make or model complete all as specified and directed. | | 6 | Each |
|---|
| 49 | 48 | Supply & Fix in repair PVC float valve assembly 15mm bore suitable for water cooler complete all as specified as directed | | 30 | Each |
|---|
| 50 | 49 | Supply & Fix in repair 15 mm bore lift cock tap suitable for water cooler complete all as specified as directed | | 30 | Each |
|---|
| 51 | 50 | Supply & Fix in repair 15 mm PVC connection 1 Metre long suitable for water cooler complete all as specified as directed | | 30 | Each |
|---|
| 52 | 51 | Supply & Fix in repair 1 1/4\" flexible hose suitable for water cooler drain complete all as specified as directed. | | 50 | RM |
|---|
| 53 | 52 | Removing old perished insulations and Supply & Fix nitrile rubber insulation for copper pipe of size 3/8\" & 5/8\" for suction and liquid refrigerant line suitable for 1.5/2 TR AC (for suction and liquid refrigerant line suitable for split type AC) complete all as specified as directed. | | 100 | Each\nJob |
|---|
| 54 | 53 | Supply & Fix in repair Copper tube 3/8\". | | 30 | RM |
|---|
| 55 | 54 | Supply & Fix in repair Copper tube 5/8\". | | 100 | RM |
|---|
| 56 | 55 | Supply & Fix in repair Copper tube 1/4\". | | 100 | RM |
|---|
| 57 | 56 | Supply & Fix in repair Copper tube 1/2\". | | 60 | RM |
|---|
| 58 | 57 | Supply and replacement of Prime Control Remote Board with temperature sensor suitable for split type AC of 1.5/2 TR, of any make or model complete all as per site requirement. | | 35 | Each |
|---|
| 59 | 58 | Supply and replacement Prime Control Remote Board of inner unit and temperature sensor suitable for inverter type split type AC of 1.5/2 TR, of any make or model complete all as per site requirement. | | 5 | Each |
|---|
| 60 | 59 | Supply and replacement of Prime Control Power Supply Board of outer unit suitable for inverter type split type AC of 1.5/2 TR, of any make or model complete all as per site requirement. | | 10 | Each |
|---|
| 61 | 60 | Supply and replacement of Prime Control power supply Board, suitable for 3 phase tower AC of 2.5/3/4TR, of any make or model complete all as per site requirement. | | 3 | Each |
|---|
| 62 | 61 | Supply and replacement of factory made steel bracket or Stand/ steel square frame stand with nuts/bolts fixed on walls/ roof/plat forms duly painted suitable for outdoor unit of split AC of capacity 1.5 /2 TR including necessary drilling work, making good etc, complete all as specified and directed. | | 10 | Each |
|---|
| 63 | 62 | Supply and fill Refrigerant Gas R-22 complete all as specified and directed. | | 360 | Kg |
|---|
| 64 | 63 | Supply and fill Refrigerant Gas-410a (Penta & Di Fluoroethane) complete all as specified and directed. | | 120 | Kg |
|---|
| 65 | 64 | Supply and fill Refrigerant Gas R- 32 complete all as specified and directed. | | 120 | Kg |
|---|
| 66 | 65 | Supply & Fix in replacement of PVC conduit pipes of 20mm dia SDR11 & plain CPVC SDR 11 with fittings on wall / Ceilings or laying in floors complete all as specified. | | 50 | RM |
|---|
| 67 | 66 | Supply & Fix in repair to voltage stabilizer 5 KVA by rewinding the main stabilizing unit and replaceing PCB, sensing unit, power realy, connector piece and testing on completion all as specified and as directed | | 15 | Each\n |
|---|
| 68 | 67 | Ditto all as per Serial item No 66, but for 4 KVA. | | 15 | Each\n |
|---|
| 69 | 68 | Supply & Fix in repair 3 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 2.5Sqmm, complete all as specified and directed. | | 360 | RM |
|---|
| 70 | 69 | Ditto all as per Serial item No 68, but for 4Sqmm. | | 80 | RM |
|---|
| 71 | 70 | Material & Labour Sealed compressor unit suitable for 2.5/3 TR capacity 3 phase suitable for Tower/Split/Caste type AC including first filling of refrigerant gas, compressor oil etc, including taking down of old unserviceable one, testing and commissioning complete all as specified and directed. | | 2 | Each\nJob |
|---|
| 72 | 71 | Supply & Fix in repair Industrial type metallic 3 pin top 20 amps 240 V complete all as specified and directed. | | 30 | Each |
|---|
| 73 | 72 | Material & Labour in replacement of sub main wiring on wall /ceiling with 2 runs of 4 Sqmm single core PVC insulated un sheathed multi stranded copper cunductor FR cable 1100V grade drawn through and including PVC conduit pipe of medium grade not less than 20mm dia including PVC conduit specials and 1 run of 4 Sqmm cable single core 1100 V grade multi stranded copper conductor FR cable as earth continuity conductor and connecting with suitable size thimble including taking down of old one complete all as specified and directed.\nNote: 2 run of sub main wire, 1run of earth wire and PVC conduit with accessories shall be measured as One Unit\n | | 50 | RM |
|---|
| 74 | 73 | Supply & Fix in repair sheet metal enclosure single pole with a two pin and earth plug and socket with and including one single pole MCB 20 AMP, 240V, complete all as specified and directed. | | 6 | Each |
|---|
| 75 | 74 | Supply & Fix in replacement, MCB SP 6 to 32 Amps \"C\" series 240V, complete all as specified and directed. | | 10 | Each |
|---|
| 76 | 75 | Material & Labour for spray painting single coat anti corrosive enamel paint to cover of window AC of any capacity complete all as specified and directed. | | 50 | Each |
|---|
| 77 | 76 | Material & Labour for spray painting single coat anti corrosive enamel paint to outer unit of split AC 1/1.5/2 TR capacity complete all as specified and directed. | | 50 | Each |
|---|
| 78 | 77 | Material & Labour for spray painting single coat anti corrosive enamel paint to water cooler of any capacity complete all as specified and directed. | | 50 | Each |
|---|
| 79 | 78 | Material & Labour for dismantling, taking down after disconnection split A/C of capacity 1.5/ 2.0TR from existing location including indoor/ outdoor units alongwith its pipes, connecting cables, clamps/ stands, water drain pipes etc including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of A/C unit in all respect complete as directed by Engineer-in-charge | | 6 | Each\nJob |
|---|
| 80 | 79 | Material & Labour for servicing of condenser coil of ductable / Tower split ACs of 2.5/3 TR capacity ,cleaning /pressure washing of chocked condensor,fins, tubes etc with water soluble material including leak testing complete all as specified and directed . | | 5 | Each\nJob |
|---|
| 81 | 80 | Wiring letters or figures for permanent marking of MES No with anti corrosive enamel paint not exceeding 3 cm in height as numbers obtained from Engineer in charge in window AC/Split ACs inner and outer unit with thick approved colour paint all as directed | | 600 | Each\nJob |
|---|
| 82 | 81 | Supply & Fix in repair of Stop valves of 15mm, chromium plate, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for CPVC pipe, unions and fixed. | | 25 | Each |
|---|
| 83 | 82 | Material & Labour for disconnecting the unserviceable stabilizer of any capacity 230 volts, any make from site and servicing complete and refixing back with necessary nuts/bolts fixed on walls and connecting up with A/C's drilling as per site requirement complete all as directed by Engineer in Charge. | | 50 | Each |
|---|
| 84 | 83 | Amount of Credit Schedule shall be deducted to arrive the Contract Sum. | | | |
|---|