Certain Sanctioned Work For Age B / R And Age E / M At Nams-2 Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 3 M&L For Rough Excavation Not Exceeding 1.5 M Deep And Getting Out In Soft / Loose Soil Complete All As Spd And Directed. 4 Excavation In Trenches, Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M Depth For Foundation, Etc., And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 5 Excavating Post Holes Or Similar Holes, Each Not Exceeding 0.5 Cum, Getting Out In Soft / Loose Soil, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25 Cm, Watering, And Removing Surplus Soil To A Distance N.Exc 50M & Making Good Surface 6 M&L For Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Under Floors Or Trenches Complete All As Specified And Directed.Complete All As Spd 7 M&L For Removing Excavated Soil N Exc. 50M And Depositing Where Directed At A Level N Exc. 1.5 M Above The Starting Point Complete All As Specified And Directed. 8 M&L Hardcore Of Gauge Not Exc 63Mm Broken Stone Or Boulders But Not Exc 100Mm, Deposited, Spread And Levelled In Layers Not Exc 15 Cm Thick, Watered And Rolled / Rammed To A True Surface For Levelling The Surfaces 9 M & L Reinforced Cement Concrete Type A1 1:1.5:3 ( Using 20 Mm Graded Stone Aggregate ) In Foundations Including Rafts, Footings And Mass Concrete Complete All As Specified And Directed. 10 M & L For Pcc 1:2:4 Type B-2 ( Using 12.5 Mm Graded Stone Aggregate ) As In Flooring Incl Finishing The Cement Concrete Surface Even And Smooth With Using Extra Cement , Rubbish Off The Primises Complete All As Specified And As Directed By Engg-In-Charge. 11 M&L For Cement Concrete , Type C1 1:3:6 ( Using 40 Mm Graded Aggregate ) As In Foundation Filling And Mass Concrete Complete All As Specified And Directed. 12 M&L For Hard Core Of ( Broken Bricks ) Of Guage N.Exc 63Mm Deposited Spread And Levelled In Layer N.Exc 15Cm Thick Watered And Rolled / Rammed To A True Surface Complete All As Specified And Directed. 13 M & L For Plain Cement Concrete Type D2 1:4:8 ( Using 40 Mm Graded Granite Stone Aggregate ) In Foundations, Filling And Mass Concrete Complete All As Specified And Directed. 14 M&L Pcc 1:2:4 Type B1 ( Using 20 Mm Graded Stonr Aggregete ) As In Coping, Benching Etc Complete All As Specified And Directed. 15 Supply Only Integral Water Proofing Compound. 16 M&L For Brick Work With Subclass ‘B’ Bricks, Straight Or Curved On Plan Exc 6M Mean Radius, Built In Cm 1:6 Complete All As Specified And Directed. 17 M&L For Brick Work With Locally Available Subclass ‘B’ Old Size Bricks, Straight Or Curved On Plan To Any Radius In Half Brick Thick Walls Built In Cm 1:6 Complete All As Specified And Directed By Engg-In-Charge. 18 Material And Labour For 15Mm Thick Cement Plaster In Cm 1:4 On Fair Faces Of Brick Work And Finishing The Surface Even And Smooth ( Without Using Extra Cement ) Etc. Complete All As Specified And Directed. 19 M&L For Newly Plastered Wall Surfaces And Applying Two Coats Of Exterior Weather Proof Emulsion Paint Over One Coat Alkali Resistant Primer Complete All As Specified And Directed. 20 M & L For 15-17Mm Thick Kota Stone Slab As In Treads, Risers And Flooring Etc. Laid Over 15 Mm Thick Screed Bed Or Bedding Layers In Cm 1:6 And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Cutting And Mirror Polished Polishing Types Complete All As Specified And Directed. 21 S & F Mild Steel Rag Or Lewis Bolts Of 20 Mm Dia, Screwed One End, With Hexagonal Or Square Nuts And Washers, The Other End Enlarged And Jagged Or Lewised And Exc. 30 Mm Long Complete All As Specified And Directed. 22 S & F Steel Work In Tubular Trusses And Tubular Posts Including Special Shaped Washers, Etc., Complete Using But Welded Tubes Confirming To Is 1161- 1979 Graded St 240 Complete All As Specified And Directed. 23 S & F Rolled Mild Steel Plates ( Plain Or Chequered ) Channels, Square Cut Or Notched, Forming Holes, Without Any Attachment Confirming To Fe 410 - W ( Gde E-250 ) Quality-A, Complete All As Specified And Directed. 24 M&L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Over Steel Surfaces Including Preparation Of New Surface Complete All As Specified And Directed. 25 S&F For Pre- Painted Galvaume Aluminum Zinc Coating Gi Based Manglore / Trapezoidal / Semi Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding, Fixed With Self Tapping Screws As Specifiedcomplete All As Specified And Directed. Nnote- Design / Pattern / Colour Of Roofing Sheet Sheet To Decided And Approved By Eic / Ge. 26 M & L For 0.63Mm Thick Plain, Galvanised, Mild Steel Sheeting, In Ridges, Hips, Valley Gutters, Drip And Straight Flashings ( Length And Girth As Fixed ) With Grade Of Zinc Coating 275 Complete All As Specified And Direcyed. 27 Use And Waste Form Work To Sides Of Concrfete Footings And Similar Works For Fair Finished Surface All As Specifed And Directed. 28 Use And Waste Of Form Work To Edges Of Concrfete Flats, Slabs Etc Incl Fair Finished Surface All As Specifed And Directed. 29 Use And Waste Of Form To Staircases With Sloping Or Stepped Soffits Including Risers And Stringers ( Excluding Landing ) Complete As Specified And Directed. 30 M & L For Plain Cement Concrete Type B1 1:2:4 ( Using 20 Mm Graded Granite Stone Aggregate ) In Foundations, Filling And Mass Concrete. 31 M & L For Formwork To Sides And Soffits Of Floor Or Roof Beam, Lintel Beams Flat Surface Etc Incl Supports, Overhangs Etc Complete All As Specified. 32 M&L For Box Type Steel Window 1.25 Mm Thick Made Of Erw Tube P-Section Of Size 60 X 25 Mm Double Rebated Outer Frame Comprise Of Glazed Skeleton Shutter ( Two Gauged Shutters And Two Glazed Shutter ) Of Erw Tube P-Section Size 50 X 20 Mm And 1Mm Thick One / Two Nos Openable Leaf Consisting Of Two Nos Sash Bar Of T-Section 20X3mm Welded To Frame With One No Vertical Mullion Of Erw Box Type T-Section Of Size 60 X 25 Mm And 1.25 Mm Thick And Fi 2 Mm Thick Welded / Screwed To Frame For Fixing Of Glass Including Fittings And Fixture Like Handle, Tower Bolt, Stopper, Cleat, Pintal Hinges, Hold Fast Etc. ( I ) Hold Fast, 150Mm Long Of 120Mm X 3 Mm Made To Shape -04 Nos Per Window. ( Ii ) Handle Of Z Sec 20Mm X 25Mm, 100 Mm Long -1 No Per Leaf ( Iii ) Ms Tower Bolt 150Mm Long - 2 No Per Leaf ( Iv ) Z Sec 20Mm X 25 Mm, 100 Mm Long Stopper - 1 No Per Leaf ( V ) Cleat 55 Mm Long Of Hollow Square 15Mm X 20Mm X.63Mm Welded To Hinge -1 No Per Leaf. ( Vi ) Ms Pintal Hinges Of Size 75Mm X 12Mm - 2 Nos Per Leaf . ( Vii ) 10 Mm Square Guard Bar, 10 Cm Centre To Centre. ( Viii ) 25X4 Mm Flat Iron All Around For Joint Of Both Frame. ( Ix ) Stainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.40 Mm And Fixed With Stainless Steel Wire Staples. ( X ) Two Coat Of Synthetic Enamel Paint To Ms Window And Guard Bar Complete All As Specified And Directed. 33 S & F Mild Steel Box Type Ventilator Fixed Type With Glazing Bar With Mesh & Glass As Per Drg No. Cejz / Td-06 / 07 Dt 07.06.07 Complete All As Specified. 34 S&F Tmt Bars 10Mm Dia And Over, Cut To Length, Bent To Shape Required, Incl Cranking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With The Mild Steel Wire ( Annealed ) Not Less Than 0.9Mm Dia Or Securing With Clips And Complete All As Specified. 35 All As Per Item 34 Here In Before But 6 To 8 Mm Dia And Including In Stirrups, Spacers And Binders And Complete All As Specified. 36 Supply And Fixing Mild Steel Roof Truss, Purlins, Rail And Fastenings And Heavy Bracket Framing ( Beam, Tee, Angle, Channel, Flat Section ) Including Distrance Pieces, Welding Work, Cleats, Nutand Bolt Etc ( Fe 410W ) Complete All As Specified And Directed. 37 S&F 1.25Mm Thick Steel Rolling Shutter With Ball Bearing And Gear Operated Type With Bevel Gear Box And Crank Handle As Specified Including To Hood Cover , An-Choring Rod, Stopper, Holdfast, Pulling Hook, Sliding Lock, Handle Hasp And Staple And One Coat Of Primer Erected In Position As Indicated Complete All As Specified And Directed By Engg-In-Charge. 38 S & F Safety Lever Locks Mild Steel With 4 Levers For Rolling Shutters Complete All As Specified And Directed By Engg-In-Charge. 39 S & F Ball Bearing For Rolling Shutters Complete All As Specified And Directed. 40 Supply And Fixing Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, In Ridges, Hips, Vally Gutter, Drip Complete All As Specified And Directed By Engineer-In-Charge. 41 S & F Mild Steel Plates ( Plain Or Chequered ) Channels, Square Cut Or Notched ( Ordinary And Counter Sunk ) Forming Holes, Without Ant Attachment ( Fe 410-W ) Gde-E-250 Quality-A Complete All As Specified And As Directed By Engg-In-Charge. 42 M&L For Providing 75 Mm Thick Cement Concrete ( 1:3:6 ) Type Ci Using 40Mm Graded Stone Aggregate As In Plinth Protection / Pathway Surfaces Even And Smooth Without Using Extra Cement. 43 M&L For Pre Cast Rcc Normal Mix ( 1:2:4 ) Type B1 ( Using 20 Mm Graded Stone Aggregate ) . As In Slabs Supported On Walls, Beams And Coloums In Floors And Roofs, Landing Balconies Chaza, Etc All As Specified And Directed . 44 M&L For 15 Mm Thick Rendering On External Surface With Cement Mortar ( 1:4 ) On Fair Face Of Brick Or Concrete Surface Finished Even And Fair Using Wpc @3% By Weight Of Cement Complete All Specified And Directed ( Wpc Shall Be Mesuredand Paid Saparately ) . 45 M&L For 15 Mm Thick Rendering On Internal Surface With Cement Mortar ( 1:6 ) On Fair Face Of Brick Or Concrete Surface Finished Even And Fair Complete All Specified And Directed . 46 M&L Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Of Shade As Approve Over A Coat Of Cement Primer On Wall Complete All As Specified And Directed. 47 M & L For Preparation Of New Plastered Surface Of Walls And Applying Three Coats Of White Wash As Directed. 48 S&F In 3Mm Glass Thick Ordinary Quality And Glazing With Oil Putty Or Wooden Beading And Securing Pins N.Exc 0.50 Sqm Each Panes Complete All As Specified And Directed. 49 M & For Reinforced Cement Concrete Type B0 1:2:4 ( Using 12.5 Mm Graded Granite Stone Aggregate ) In Lintels Upto 1.5M Clear Span, Cills, Steps; Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60 Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs Not Provided For In Item 159, Water Troughs And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating, As Directed 50 Supply, Lowering, Commissioning & Testing Of Submersible Pump Capacity 1350 Lpm At Head Of 80 Mtr With Out Let Size 100 Mm Dia Bore Including Electric Motor Driven 415 V 50 Hz Complete All As Specified And Directed. 51 Supply, Lowering, Commissioning & Testing Of Submersible Pump Capacity 1650 Lpm At Head Of 80 Mtr With Out Let Size 125 Mm Dia Bore Including Electric Motor Driven 415 V 50 Hz Complete All As Specified And Directed. 52 Supply, Lowering And Fixing Ms Heavy Duty Flanged Pipe 5.4Mm Thick 100 Mm Bore ( Length Not Less Thatn 3 Mtr Each ) Ms Flanged Not Less Than 15Mm Thick On Both Side, With Drilled Holes And Welded To Ms Pipe, Including Material And Labour For Jointing, Fixing With Nuts, Bolt, Rubber Packing Complete All As Specified And Directed. 53 Supply, Lowering And Fixing Ms Heavy Duty Flanged Pipe 5.4Mm Thick 150 Mm Bore Or Nearest Higher Size Bore ( Length Not Less Thatn 3 Mtr Each ) Ms Flanged Not Less Than 15Mm Thick On Both Side, With Drilled Holes And Welded To Ms Pipe, Including Material And Labour For Jointing, Fixing With Nuts, Bolt, Rubber Packing Complete All As Specified And Directed. 54 S&F Submersible Cable 25 Sqmm, 3 Core Pvc Copper Cable, 1100 Volts Gradde Conforming Is 694, Complete With All Accessories All As Specified And As Directed. 55 Supply, Laying & Fixing Double Wall Corrugated ( Dwc ) Pipes For Passing The Cable Along Wall / Under Road, Path Etc Made Of High Density Polythyline ( Hdpe ) With All Accessories I.E. All Type Of Joints, Sockets, Elbows, Bends And End Caps Etc.. All As Specified And Directed By Engr In Charge.Of Size 40 Mm Outer Dia And 38 Mm Inner Dia Of Pipe 56 Supply, Install, Testing & Commissioning Factory Made Indoor Type Dust And Vermin Proof Motor Starter Panel Cubical Double Door Hinged Type Compartmentalized Of Suitable Size Fabricated Of Crca Sheet 2.0 Mm Thick Machine Pressed And Angle Iron Frame Powder Coated Inside And Outside, Including 4 Pole 415 Volt, Ac, 50 Hz, Copper Busbar Of Capacity 300 Amps Mounted On Porcelain Insulators And Enclosed In Bus Bar Chamber And Connection From Incoming And Outgoing Electric Cable With Suitable Size Thimbs.Lugs With Openable Shutters And Fixed On Angle Iron Frame Made Out From 40X40x6mm Angle Iron Andgrounted In Pcc 1:2:4, Type B 1 ( Using 20Mm Graded Stone Agregate ) , Including Accomodating & Comprising Of The Following Including Taking Out Old Unserviceable Motor Starter Panel All As Specified And Directed :- ( A ) Mccb 250 Amps Capacity With Adjustable Thermal Release 4 Pole Of 25 Ka Rupturing Capacity - 01 No ( Incomming ) . N ( B ) Mccb 160 Amps 25Ka , Three Pole 415 Volt - 01 No. ( Outgoing ) N ( C ) Mcb 32 Amps 10 Ka Tpn 415 Volt - 02 No. ( Out Going ) ( D ) ( I ) Digital Volt Meter Showing 0-500 Volts Complete With Duly Nprewired With Copper Cable Of Suitable Size - 01 No. ( Ii ) Digital Ampere Meter Showing 0-100 Amps With - 01 No. N ( Iii ) Indication Lamp Ryb Led Type With Protection Fuses- 01 Set ( Iv ) Soft Starter In Steel Enclosure Comprising Of The Following Appliances Of Make L&T Csxi Model Cat Part Csxi-037-41 Or Equivalent In Siemens, Havells Etc:- Na ) In Built Bypass Contractor Nb ) Soft Start / Start Stop / Adjustable Current Limit Nc ) Essential Motor Protection Against ( I ) Overload ( Ii ) Single Phasing ( Iii ) Instantaneous Overcurrent ( Iv ) Phase Sequence Reversal ( V ) Abnormality In Supply ( Vi ) Unbalanced Current Nd ) Thermistor Protection Through Ptc Ne ) Excess Start Time Setting 57 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick Burried Directly In Ground Vertically To A Depth Not Less Than 2.25 Meter Below Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Meter Below Level Connected An Including Gi Strip 32 X 6 Mm As Earth Lead Upto 7.5 Mtr Long By Means Of Bolts, Nuts, Check Nuts And Washers Etc With Gi Protection Pipe Of 40 Mm Bore Medium Grade And Connected To Earthing Test Point All As Shawn In Electrical Plate No 3 Of Sr Part-I And As Specified Or Indicated Including Excavation & Earth Work In Any Type Of Soilpcc ( 1:2:4 ) Type B1 ( Reinforced With Welded Steel Wire Fabric ( Xpm ) Of Weight Not Less Than 4 Kg ( Sqm ) With Frame Funnel With 20 Mm Bore Gi Pipe Medium Grade Watering Pipe, Wire Mesh And Lugs Test Point Etc And Testing On Completion. Nnot : ( A ) The Unit Rates Includes 32 X 6Mm Gi Pipe Strip And 40Mm Gi Protection Pipe Top Of Earth Plate Upto Test Point ) 58 M&L For Point Wiring With 1.5 Sqmm ( Nominal Area ) 1100 Volt Pvc Insulated , Frls Unsheathed And Multi Stranded Copper Conductor Cable In And Including New Pvc Concealed Conduit Not Less Than 20Mm Dia 1.5Mm Thick For One Light / Fan Point Or Bell Point Controlled By One Switch ( Including Cutting Chases And Making Good The Disturbed Surfaces ) And Fixing New 3Mm Thick Hylem Sheet Top Cover, Sheet Screws And 1.6Mm Thick Gi Sunken Boxes Included 1.5 Sqmm Stranded Copper Conductor With Green Pvc Insulation Earth Contunity Conductor Connected To Common Earth Dolly Etc . Complete All As Specified And Directed. Note : The Cost Of Sunken Boxes And Bakellite Sheet Is Included In The Quoted Rate ) 59 All As Per Item 58 Here In Before But For One Three Pin Socket Outlet 5 Amps Independent Board Complete 60 All As Per Item 58 Here In Before But For One Three Pin 5 Amps Socket Outlet On The Same Board With Other Switches 61 All A Per Item No 58 Here-In-Above But With 2.5 Sq Mm Size Cable Multi Stranded Frls Copper Wire Unsheathed For One 3 Pin Socket Outlet 15 Amps On Independent Board Including Continuous Earth Wire Of Pvc Insulated 1.5 Sq Mm Copper Solid Conductor Connecting To Common Earth Dolly Complete. 62 Supply And Fixing Switch Piano Type 6 Amps One Way 230 Volts Ac Complete All As Specified And As Directed 63 Supply And Fixing Socket Outlet 5 Pin, 6 Amps Flush Type 230 Volts Ac Complete All As Specified And As Directed 64 Supply And Fixing Switch Piano 16 Amps Type One Way 230 Volts Ac Complete All As Specified And As Directed 65 Supply And Fixing Socket Outlet 6 Pin 6 / 16 Amps Multi Purpose Flush Type 230 Volts Ac Complete All As Specified And As Directed 66 Supply And Fixing Ceiling Rose 65X50 Mm Two To Three Terminals Complete All As Specified. 67 Material And Labour Of Lamp Holder Insulated Body With Back Plate Angle Type For Batten Fitting Fixed On Bakelite Sheet 100Mmx100mm With 10 Watt Led Bulb 230V Ac Cool Day Light 6500K Having Maximum Height 1020Mm Heavy Duty Complete All As Specified. 68 M&L For Two Single Core Sub Main Wiring 6 Sqmm Multi-Strand Pvc Insulated Frls Copper Conductor Cable Including Pvc Insulated Copper Conductor Cable Of Size 6 Sqmm As Cotinuous Earth Wire Connecting To Common Earth Including Pvc Conduit , Connections Of Cable With Mcbs Or Bus Bars Complete All As Specified And Directed 69 M & L For Sheet Steel Enclouser Distribution Boards, Double Door Factory Made 3 Phase 415 Volts 4 Way With 200 Amps Rating Copper Bus Bar And Pvc Insulated Copper Jumpers Of Suitable Size From The Mccb To The Out Going Circuits One Incoming Mccb And 12 Outgoing Mcbs Circuits Comprising Of 3 Phase 4 Wire Of Suitable Rating Complete All As Spcd And Directed With The Following Accessories :- ( For Out Going Mcb Measured And Paid For Separately ) ( A ) Mccb 100 Amps, 16 Ka, Tp, 415 Volts, 50 Hz = 01 No. 70 Supply And Fixing Mcb Single Pole 6 To 32 Amps All As Specified And Directed 71 Supplying And Fixing Mcb Dp 40 Amps 240V, 10 Ka, Complete All As Specified And As Directed 72 M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode Of Size 600 Mm X 600 Mm X 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Ground Level, Connected To Galvanized Earth Lead Wire 4.00 Mm Dia By Means Of Bolts Nuts Check Nuts & Washers Of Galvanized Iron Or Steel , Procteded By Gi Pipe 15 Mm Bore ( Light Grade ) And Watering Pipe 20 Mm Bore Gi Pipe ( Light Grade ) And Chamber Of Pcc 1:4:8 Type D2 Using 40 Mm Graded Stone Aggregate And Coping Shall Be In Pcc 1:3:6 Type C1 Using 20Mm Graded Stone Agg. 50 Mm Thick Cover Of Rcc 1:2:4 Type B1 Using 20 Mm Graded Stone Agg. Reinforced With 8 Mm Dia Ms Tor Bar @ 80 Mm C / C Both Ways Including Excvation And Earth Work And Removal Of Surplus Soil Complete All As Shown In Electrical Plate No 5 Of Ssr Pt 1, 1991 With Charcoal Dust And Salt Complete And Earth Lead Connected To Earthing Test Point ( Up To Main Switche, Dbs ) Complete All As Specified & Testing On Completion. 73 Supply & Fix Of Led Street Light Luminaire 25 Watt 6000K With .High Power Led Cool White, Cri 75, + / - 5% Supply Voltage 220 / 240 / 50 Hz, Light Engine Driver Base.Pole Adapter, Powder Coated Pressure Die Cast Aluminium With Heat Resistant Toughened Glass With Lens.Complete All As Specified And As Directed. 74 Supply & Laying Xlpe Insulated Armoured Heavy Duty Electric Cable With Aluninium Conductor 1100 Volt Grade Cross Section Area 4 Core 25 Sqmm Complete All As Specified And As Directed. 75 Supply, Laying & Fixing Double Wall Corrugated ( Dwc ) Pipes Made Of High Density Polythyline ( Hdpe ) With All Accessories I.E. All Type Of Joints, Sockets, Elbows, Bends And End Caps Etc.. All As Specified And Directed By Engr In Charge.Of Size50 Mm Outer Dia And 38 Mm Inner Dia Complete All As Specified And Directed. 76 Supply And Fixing Of Led T-8 Tube Light Fitting With Single Side Connection Led Tube Rod 18 / 20W 4 Feet 1 X 18 / 20 Watt Ms Crca Box Type Including Rotary Type Bipin Holder And Connection With Pvc Insulalted Twin Core 23 / 0.0076 Twisted Copper Cable From Ceiling Rose To Tube Light Fitting Complete All As Specified And Directed. 77 Supply And Laying Or Fixing 1100 Volts Grade Heavy Duty Cable With Pvc Insulated Aluminium Standard Conductor Served With An Inner Sheathing Of Pvc Tape And Over All Pvc Sheathed In Service Connections One Twin Core 6 Sqmm Cable Standard Conductor Cable Flat Or Circular All As Specified And Directed By Engineer- In- Charge. 78 S &F Sheet Metal Enlosure For Dbs Where Mcbs To Be Used Double Door Factory Made Flush Fixed Complete With 100 Amps Rated Bus-Bar 240 Volts Single Phase 8 Ways Complete All As Specified. 79 S &F Led Bulk Head Light Fittings 10Watt White Including Led Strip As Per Ip65 In Enginnering Plastic Housing Withclear Prismatic Diffuser And Making Necessary Connections Complete All As Specified 80 S & F Bracket Made Out Of Gi Pipe 40Mm Medium Grade 1.2 Mtr Long Made To Shape With Fixing Clamps Of Ms Flat 40X6mm Nuts Bolts Etc For Street Light All As Specified Vand Direceted. 81 Supply & Fixing Flood Light Luminaire 120 Watt With High Power Smd Led Cool White, Supply Voltage 220 / 240 / 50 Hz, Light Engine Driver Base Pole Adapter, Pressure Die Cast, Polycarbonate, Powdre Coated In Ip 66 Incliding Protection Over Temperature Should Be From The Same Manufacturer Product Complete All As Specified And As Directed, 82 Supply And Fixing Ceiling Fan 1200Mm Sweep Copper Winding With Electronic Regulator, Low Power Consumption, High Speed Aluminium Body With Blade, Double Ball Bearing Of Bee Star Rated Including Acessories Connector, Canopy, Hanging Rod And Clamps , Including Electric Connection With Pvc Flexible Twin Core Copper Wire From Ceiling Rose To Ceiling Fan Complete All As Specified And Directed.