Repair And Maintenance Of Summer Appliences Repair And Maintenance Of Summer Appliences At Dronachal Bhopal, GE Dronachal-Madhya Pradesh

Statutory Bodies & Commissions/Committees has published Repair And Maintenance Of Summer Appliences Repair And Maintenance Of Summer Appliences At Dronachal Bhopal. Submission Date for this Tender is 20-08-2020. Screws Tenders in GE Dronachal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

25001436
Corrigendum : Repair And Maintenance Of Summer Appliences Repair And Maintenance Of Summer Appliences At Dronachal Bhopal
Open Tender
Indian
Madhya Pradesh
Ge Dronachal
20-08-2020

Tender Details

Repair And Maintenance Of Summer Appliences Repair And Maintenance Of Summer Appliences At Dronachal Bhopal , M&L For Servicing Package Type Ac Plant Of 11 Tr Capacity Of Make Blue Star With Greasing Of Motor Bearings , Replacement Of Belts , Adjustment Of Tension Of Belt , Cleaning Of All Filters , Checking Of Complete Wiring , Topup Of Gas ( Refrigerant ) , Tightening Of Nut Bolts , Oiling And Greasing Of All Movable Parts Comp [ Lete All As Specified And Up The Satisfaction Of Engr-In-Charge . ( Note : Cost Of Belt , Refrigerant Gas And Lubricant Etc Required For Servicing Is Deem To Be Included In Unit Rate And No Extra Cost Will Be Paid For This Separately ) . , M&L For Replacement Of Aluminium Fan Blade For Condensing Fan Motor Of Capacity 11Tr Capacity . , M&L For Replacement Of Alumium Fan Blower For Cooling Fan Motor Of Capacity 11Tr Capacity . , M&L For Foam Type Insulating Flexible Pipe Fitted On Suction / Discharge Copper Tubes . , S&F Condenser Fan Motor Of Ductable Type Ac Of Capacity 11 Tr As Per Existing Make And Model Complete All As Directed By Engineer-In-Charge . , S&F Cooling Fan Motor Of Ductable Split Type As Per Existing Make And Model Of Capacity 11 Tr Complete All As Directed By Engineer-In-Charge . , S & F In Repairs Wiring Kit Of Package Type Ac Plant Of 11 Tr Capacity Complete With Lugs , Thimble And Selector Switch , Complete All As Directed . , S & F In Repairs Starting / Running Capacitor , Suitable For Ductable Type Ac Of Capacity 11 Tr . Complete All As Directed . , Disconnecting Dismentalling And Removing Of U / S Condensor Unit Coil And S / F In Replecement Of Condensor Coil Unit Including Conection Of Copper Tubing For Of Ductable Type Ac 11 Tr Capacity All As Directed . . , Disconnecting Dismentalling And Removing Of U / S Cooling Coil From Indoor Unit Complete And Supplying And Fixing Of New Indoor Cooling Coil Unit Of Ductable Type Ac Of Capacity Of 11 Tr , Including Connection Of Copper Tubing All As Directed . , S&F In Repaired Rotary Type Compressor Of Package Type Ac Plant Of 5 . 5 Tr Capacity With Starting And Running Capacity And Relay Including Connection Of Coppertubing And Topping Up Of Refrigerant Gas For Smooth Functioning , Complete All As Directed . , Supply And Topping Up Of Refrigerant Gas R 22 In Air Conditioner At Different Site As Required Including Brazing And Removal Of Leakage In Equipment , M & L For Wall Mounted Stablizer Of Capacity 2 Kva Including Fuze Assy , Terminal Panels , Indicators , Time Delay Relay And 3 Core Pvc Lead And Re-Assembling And Fixing In Position Complete All As Directed By Engr In Charge . , M & L For Taking Down Wall Mounted Stablizer Of Capacity 5 Kva Including Fuze Assy , Terminal Panels , Indicators , Time Delay Relay And 3 Core Pvc Lead And Re-Assembling And Fixing In Position Complete All As Directed By Engr In Charge . , S & F In Repairs Pcb Senser Unit With Wire Remotre Control Of Ductable Ac Indoor Unit Of Capacity 11 Tr For Removing Old Pcb And Refix With New Pcb Of Same Make & Capacity And Model In The Same Position Complete All As Directed By Engr In Charge . , M & L For Sub Main Wiring Along With Earth Wire Drown Through Pvc Case & Caping For Split Type A / Cs With Frls Pvc Insulated , Unsheathed Multi Stranded Copper Single Core Cable Of Size 2 X 4 . 0 Sqmm And 1 X 2 . 5 Sqmm For Earth Wire Including Taking Down Old Wiring All As Directed . , Supply & Fixing Single Pole And Neutral Enclosure With A Two Pin And Socket Complete With One Single Pole Mcb 240 Volts , 32 Amps , M & L For Servicing Of Window Type Ac Of Capacity 1 . 5 / 2 Tr Of Any Make Including Cleaning Of Filter On Front Side By Removing Dust , Cleaning The Condenser Including Fins , Blower Fan Motor And Checking And Testing Of All Parts For Its Serviceability , Oiling / Greasing To Condenser Cum Blower Fan Motors , Replacing Worn Out Rubber , Bushes / Rubber Packing , Rectification Of Unusual Noise , Checking Of Refrigerant Standing Pressure , Topping Of Refrigerant Upto The Required Level , Replacement Of Minor Parts Such As Nut / Bolt Washers Etc And Reassembling Of Complete Ac Including Testing For Smooth Functioning . Complete All As Directed By Engineer-In-Charge . , S&F In Repairs Aluminium Fan Blade Suitable For Condenser Of Window Type Ac Of Any Capacity . , S&F In Repairs Pvc Fan Blower Of Cooling Side Of Window Type Ac Of Any Capacity . , S & F In Repairs Wiring Kit Of Window Type Ac Complete With Lugs , Thimble And Selector Switch , Complete All As Directed . , S&F In Motor For Window Type Ac Of 1 . 5 / 2 Tr Capacity , Complete All As Directed By Engineer-In-Charge . , M & L For Servicing Of Split Type Ac Of Capacity 1 . 5 / 2 Tr Of Any By Opening The Condenser Unit Fixed On Roof Top And Cooling Unit Fixed Inside The Building , And Cleaning The Complete Condenser Unit And Cooling Unit Including Fins , Blower Fan Motor And Checking And Testing Of All Parts For Its Serviceability , Oiling / Greasing To Condenser Cum Blower Fan Motors , Remore Replacing Worn Out Rubber , Bushes / Rubber Packing , Rectification Of Unusal Noise , Checking Of Refrigerant Standing Pressure , Topping Of Refrigerant Upto The Required Level , Replacement Of Minor Parts Such As Nut / Bolt Washers Etc And Reassembling Of Complete Ac Including Testing For Smooth Functioning Complete All As Directed By Engineer-In-Charge . , Replacement Of Blade For Condensing Fan Motor Split Type Ac :- , Capacitor 45 Mfd , Capacitor 6 Mfd , Capacitor 2 . 5 Mfd , S & F In Repairs Running Capacitor , 36 Mfd Suitable For Ac Of Capacity 1 . 5 Tr . Complete All As Directed . , S & F In Repairs Starting Capacitor , 100-120 Mfd Suitable For Ac Of Capacity 1 . 5 Tr . Complete All As Directed . , M&L For Removing The Cooling Fan Motor Of Capacity 1 / 30 Or 1 / 35 Hp From Split Type Ac , And S&F The Same Complete All As Directed By Engr-In-Charge . , S&F Of Blower Motor Of Capacity 1 / 30 Or 1 / 20 Hp Split Type Ac 1 . 5 / 2Tr . Complete All As Directed . , M & L For Removing The Unserviciable Compressor Sealed Unit Of Any Make From Water Cooler 40 / 80 Ltr After Cutting Copper Tubing Without Any Damage To Existing Part , Replacing Compressor With Reconditioned Compressor Of Same Make Complete With Erection Of Compressor On Base With Suitable Capillary , Filter Etc , Jointing Of Copper Copper Refrigerent Pipe Line Charging Gas To Required Level , Complete Including Cleaning Of Fins , Leakage Testing Etc Including Testing For Smooth Functioning . Complete All As Directed By Engr In Charge . , All As Per Item No . 32 Above But Compressor Of Water Cooler Of Capacity 60 / 120 Ltrs . , M & L For Removing The Unserviceable Compressor Sealed Unit Of Any Make From Window / Split Type Ac Of Capacity 1 . 5 Tr After Cutting Copper Tubing Without Any Damage To Existing Parts , Replacing Compressor With Reconditioned Compressor Of Same Make Complete With Erection Of Compressor On Base With Suitable Capillary , Filter Etc . Jointing Of Copper Refrigerant Pipe Line , Charging Gas To Required Level , Complete Including Cleaning Of Fins , Leakage Testing Etc Including Testing For Smooth Functioning . Complete All As Directed By Engineer-In-Charge . , All As Per Item No . 34 Above But For Window / Split Type Ac 2 Tr Capacity . , S&F In Repaired Compressor For Deepfrizer Capacity 200 / 400 Ltr With Relay And Thermostat Complete After Desmantalling And Disconnecting Of U / S Compressor And Topping Up Of Refrigerant Gas Upto Required Level All As Directed . , S&F In Repairs Aluminium Fan Blade For Water Cooler , S&F In Repairs Thermostat Suitable For Water Cooler Of Any Capacity . , S&F In Repairs Waste Water Tray , Stainless Steel With Coupling Suitable For Water Cooler Of Capacity 40 / 80 Ltrs . Complete All As Directed , S & F Pvc Drain Out Flexible Pipe Of 20Mm Dia 70 Cms Length With Two Mild Steel Clamps And Necessary Brass Screws Etc For Water Cooler Of Any Size C

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-08-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 20-08-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
INR 10 Lakhs /-